Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Total Environ ; 932: 172658, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38657813

RESUMO

Per- and poly-fluoroalkyl substances (PFAS) are a class of synthetic chemicals known for their widespread presence and environmental persistence. Carbon-fluorine (C-F) bonds are major components among PFAS and among the strongest organic bonds, thus destroying PFAS may present significant challenge. Thermal treatment such as incineration is an effective and approved method for destroying many halogenated organic chemicals. Here, we present the results of existing studies and testing at combustion-based thermal treatment facilities and summarize what is known regarding PFAS destruction and mineralization at such units. Available results suggest the temperature and residence times reached by some thermal treatment systems are generally favorable to the destruction of PFAS, but the possibility for PFAS or fluorinated organic byproducts to escape destruction and adequate mineralization and be released into the air cannot be ruled out. Few studies have been conducted at full-scale operating facilities, and none to date have attempted to characterize possible fluorinated organic products of incomplete combustion (PICs). Further, the ability of existing air pollution control (APC) systems, designed primarily for particulate and acid gas control, to reduce PFAS air emissions has not been determined. These data gaps remain primarily due to the previous lack of available methods to characterize PFAS destruction and PIC concentrations in facility air emissions. However, newly developed stack testing methods offer an improved understanding of the extent to which thermal waste treatment technologies successfully destroy and mineralize PFAS in these waste streams.

2.
Environ Sci Technol ; 58(8): 3942-3952, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38350647

RESUMO

Aqueous film-forming foams (AFFFs) are used in firefighting applications and often contain per- and polyfluoroalkyl substances (PFAS), which can detrimentally impact environmental and biological health. Incineration is a potential disposal method for AFFFs, which may produce secondary PFAS and other air pollutants. We used online chemical ionization mass spectrometry (CIMS) to measure volatile PFAS emissions from incinerating AFFF concentrate solutions. We quantified perfluorinated carboxylic acids (PFCAs) during the incineration of legacy and contemporary AFFFs. These included trifluoroacetic acid, which reached mg m-3 quantities in the incinerator exhaust. These PFCAs likely arose as products of incomplete combustion of AFFF fluorosurfactants with lower peak furnace temperatures yielding higher PFCA concentrations. We also detected other short-chain PFAS, and other novel chemical products in AFFF combustion emissions. The volatile headspace above AFFF solutions contained larger (C ≥ 8), less oxidized PFAS detected by CIMS. We identified neutral PFAS resembling fluorotelomer surfactants (e.g., fluorotelomer sulfonamide alkylbetaines and fluorotelomer thioether amido sulfonates) and fluorotelomer alcohols in contemporary AFFF headspaces. Directly comparing the distinct chemical spaces of AFFF volatile headspace and combustion byproducts as measured by CIMS provides insight toward the chemistry of PFAS during thermal treatment of AFFFs.


Assuntos
Fluorocarbonos , Poluentes Químicos da Água , Poluentes Químicos da Água/análise , Tensoativos/análise , Água , Fluorocarbonos/análise , Ácidos Carboxílicos/análise , Espectrometria de Massas
3.
Sci Total Environ ; 905: 167185, 2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-37734620

RESUMO

Landfills manage materials containing per- and polyfluoroalkyl substances (PFAS) from municipal solid waste (MSW) and other waste streams. This manuscript summarizes state and federal initiatives and critically reviews peer-reviewed literature to define best practices for managing these wastes and identify data gaps to guide future research. The objective is to inform stakeholders about waste-derived PFAS disposed of in landfills, PFAS emissions, and the potential for related environmental impacts. Furthermore, this document highlights data gaps and uncertainties concerning the fate of PFAS during landfill disposal. Most studies on this topic measured PFAS in liquid landfill effluent (leachate); comparatively fewer have attempted to estimate PFAS loading in landfills or other effluent streams such as landfill gas (LFG). In all media, the reported total PFAS heavily depends on waste types and the number of PFAS included in the analytical method. Early studies which only measured a small number of PFAS, predominantly perfluoroalkyl acids (PFAAs), likely report a significant underestimation of total PFAS. Major findings include relationships between PFAS effluent and landfill conditions - biodegradable waste increases PFAS transformation and leaching. Based on the results of multiple studies, it is estimated that 84% of PFAS loading to MSW landfills (7.2 T total) remains in the waste mass, while 5% leaves via LFG and 11% via leachate on an annual basis. The environmental impact of landfill-derived PFAS has been well-documented. Additional research is needed on PFAS in landfilled construction and demolition debris, hazardous, and industrial waste in the US.

4.
J Air Waste Manag Assoc ; 73(7): 533-552, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36947591

RESUMO

During thermal processes utilized in affixing fluoropolymer coatings dispersion to fibers and fabrics, coating components are vaporized. It is suspected that per- and polyfluoroalkyl substances (PFAS) from the dispersions may undergo chemical transformations at the temperatures used, leading to additional emitted PFAS thermal byproducts. It is important to characterize these emissions to support evaluation of the resulting environmental and health impacts. In this study, a bench-scale system was built to simulate this industrial process via thermal application of dispersions to fiberglass utilizing relevant temperatures and residence times in sequential drying, baking, and sintering steps. Experiments were performed with two commercially available dispersions and a simple model mixture containing a single PFAS (6:2 fluorotelomer alcohol [6:2 FTOH]). Vapor-phase emissions were sampled and characterized by several off-line and real-time mass spectrometry techniques for targeted and nontargeted PFAS. Results indicate that multiple PFAS thermal transformation products and multiple nonhalogenated organic species were emitted from the exit of the high temperature third (sintering) furnace when 6:2 FTOH was the only PFAS present in the aqueous mixture. This finding supports the hypothesis that temperatures typical of these industrial furnaces may also induce chemical transformations within the fluorinated air emissions. Experiments using the two commercial fluoropolymer dispersions indicate air emissions of part-per-million by volume (ppmv) concentrations of heptafluoropropyl-1,2,2,2-tetrafluoroethyl ether (Fluoroether E1), as well as other PFAS at operationally relevant temperatures. We suspect that E1 is a direct thermal decomposition product (via decarboxylation) of 2,3,3,3-tetrafluoro-2-(heptafluoropropoxy)propanoic acid (commonly referred to as HFPO-DA) present in the dispersions. Other thermal decomposition products, including the monomer, tetrafluoroethene, may originate from the PFAS used to stabilize the dispersion or from the polymer particles in suspension. This study represents the first researcher-built coating application simulator to report nontargeted PFAS emission characterization, real-time analyses, and the quantification of 30 volatile target PFAS.Implications: Thermal processes used to affix fluoropolymers to fabrics are believed to be a source of PFAS air emissions. These coating operations are used by many large and small manufacturers and typically do not currently require any air emissions control. This research designed and constructed a bench-scale system that simulates these processes and used several off-line and advanced real-time mass spectroscopy techniques to characterize PFAS air emissions from two commercial fluoropolymer dispersions. Further, as the compositions of commercial dispersions are largely unknown, a model three-component solution containing a single PFAS was used to characterize emissions of multiple PFAS thermal transformation products at operationally relevant conditions. This research shows that fluoropolymer fabric coating facilities can be sources of complex mixtures of PFAS air emissions that include volatile and semivolatile PFAS present in the dispersions, as well as PFAS byproducts formed by the thermal transformation of fluorocarbon and hydrocarbon species present in these dispersions.


Assuntos
Polímeros de Fluorcarboneto , Fluorocarbonos , Polímeros de Fluorcarboneto/análise , Fluorocarbonos/análise , Fluorocarbonos/química , Temperatura Alta , Temperatura
5.
J Air Waste Manag Assoc ; 73(4): 295-312, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36716322

RESUMO

Particulate matter (PM) is a major primary pollutant emitted during wildland fires that has the potential to pose significant health risks to individuals/communities who live and work in areas impacted by smoke events. Limiting exposure is the principle measure available to mitigate health impacts of smoke and therefore the accurate determination of ambient PM concentrations during wildland fire events is critical to protecting public health. However, monitoring air pollutants in smoke impacted environments has proven challenging in that measurement interferences or sampling conditions can result in both positive and negative artifacts. The EPA has performed research on methods for the measurement of PM2.5 in a series of laboratory-based studies including evaluation in smoke. This manuscript will summarize the results of the laboratory-based evaluation of federal equivalent method (FEM) monitors for PM2.5 with particular attention being given to the Teledyne-API Model T640 PM Mass monitor, as compared to the filter-based federal reference method (FRM). The T640 is an optical-based PM monitor and has been gaining wide use by state and local agencies in monitoring for PM2.5 U.S. National Ambient Air Quality Standards (NAAQS) attainment. At present, the T640 (includes both T640 and T640×) comprises ~44% of the PM2.5 FEM monitors in U.S. regulatory monitoring networks. In addition, the T640 has increasingly been employed for the higher time resolution comparison/evaluation of low-cost PM sensors including during smoke impacted events. Results from controlled non-smoke laboratory studies using generated ammonium sulfate aerosols demonstrated a generally negative T640 measurement artifact that was significantly related to the PM2.5 concentration and particle size distribution. Results from biomass burning chamber studies demonstrated positive and negative artifacts significantly associated with PM2.5 concentration and optical wavelength-dependent absorption properties of the smoke aerosol.Implications: The results detailed in this paper will provide state and local air monitoring agencies with the tools and knowledge to address PM2.5 measurement challenges in areas frequently impacted by wildland fire smoke. The observed large positive and negative artifacts in the T640 PM mass determination have the potential to result in false exceedances of the PM2.5 NAAQS or in the disqualification of monitoring data through an exceptional event designation. In addition, the observed artifacts in smoke impacted air will have a detrimental effect on providing reliable public information when wildfires occur and also in identifying reference measurements for small sensor evaluation studies. Other PM2.5 FEMs such as the BAM-1022 perform better in smoke and are comparable to the filter-based FRM. Care must be taken in choosing high time resolution FEM monitors that will be operated at smoke impacted sites. Accurate methods, such as the FRM and BAM-1022 will reduce the burden of developing and reviewing exceptional event request packages, data loss/disqualification, and provide states with tools to adequately evaluate public exposure risks and provide accurate public health messaging during wildfire/smoke events.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Humanos , Material Particulado/análise , Fumaça/análise , Sulfato de Amônio , Artefatos , Biomassa , Poluentes Atmosféricos/análise , Poluição do Ar/análise , Aerossóis , Monitoramento Ambiental/métodos
6.
ACS ES T Eng ; 3(9): 1308-1317, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38989445

RESUMO

The destruction of per- and polyfluoroalkyl substances (PFAS) is critical to ensure effective remediation of PFAS contaminated matrices. The destruction of hazardous chemicals within incinerators and other thermal treatment processes has historically been determined by calculating the destruction efficiency (DE) or the destruction and removal efficiency (DRE). While high DEs, >99.99%, are deemed acceptable for most hazardous compounds, many PFAS can be converted to other PFAS at low temperatures resulting in high DEs without full mineralization and the potential release of the remaining fluorocarbon portions to the environment. Many of these products of incomplete combustion (PICs) are greenhouse gases, most have unknown toxicity, and some can react to create new perfluorocarboxylic acids. Experiments using aqueous film forming foam (AFFF) and a pilot-scale research combustor varied the combustion environment to determine if DEs indicate PFAS mineralization. Several operating conditions above 1090 °C resulted in high DEs and few detectable fluorinated PIC emissions. However, several conditions below 1000 °C produced DEs >99.99% for the quantifiable PFAS and mg/m3 emission concentrations of several non-polar PFAS PICs. These results suggest that DE alone may not be the best indication of total PFAS destruction, and additional PIC characterization may be warranted.

7.
Environ Pollut ; 301: 119010, 2022 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-35217136

RESUMO

Nitrophenols (NPs) are hazardous pollutants found in various environmental matrices, including ambient fine particulate matter (PM2.5), agricultural residues, rainwater, wildfires, and industrial wastes. This study showed for the first time the effect of three pure nitrophenols and their mixture on human lung cells to provide basic understanding of the NP influence on cell elements and processes. We identified NPs in ambient PM2.5 and secondary organic aerosol (SOA) particles generated from the photooxidation of monocyclic aromatic hydrocarbons in the U.S. EPA smog chamber. We assessed the toxicity of identified NPs and their equimolar mixture in normal bronchial epithelial (BEAS-2B) and alveolar epithelial cancer (A549) lung cell lines. The inhibitory concentration-50 (IC50) values were highest and lowest in BEAS-2B cells treated with 2-nitrophenol (2NP) and 4-nitrophenol (4NP), respectively, at 24 h of exposure. The lactate dehydrogenase (LDH) assay showed that 4NP, the most abundant NP we identified in PM2.5, was the most cytotoxic NP examined in both cell lines. The annexin-V/fluorescein isothiocyanate (FITC) analysis showed that the populations of late apoptotic/necrotic BEAS-2B and A549 cells exposed to 3NP, 4NP, and NP equimolar mixture increased between 24 and 48 h. Cellular reactive oxygen species (ROS) buildup led to cellular death post exposure to 3NP, 4NP and the NP mixtures, while 2NP induced the lowest ROS buildup. An increased mitochondrial ROS signal following NP exposure occurred only in BEAS-2B cells. The tetramethylrhodamine, methyl ester, perchlorate (TMRM) assay showed that exposed cells exhibited collapse of the mitochondrial membrane potential. TMRM signals decreased significantly only in BEAS-2B cells, and most strongly with 4NP exposures. Our results suggest that acute atmospheric exposures to NPs may be toxic at high concentrations, but not at ambient PM2.5 concentrations. Further chronic studies with NP and NP-containing PM2.5 are warranted to assess their contribution to lung pathologies.


Assuntos
Poluentes Atmosféricos , Células Epiteliais , Poluentes Atmosféricos/análise , Humanos , Pulmão , Nitrofenóis/metabolismo , Estresse Oxidativo , Material Particulado/análise
8.
J Air Waste Manag Assoc ; 72(3): 256-270, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34994684

RESUMO

A combustion model, originally developed to simulate the destruction of chemical warfare agents, was modified to include C1-C3 fluorinated organic reactions and kinetics compiled by the National Institute of Standards and Technology (NIST). A simplified plug flow reactor version of this model was used to predict the destruction efficiency (DE) and formation of products of incomplete combustion (PICs) for three C1 and C2 per- and poly-fluorinated alkyl substances (PFAS) (CF4, CHF3, and C2F6) and compare predicted values to Fourier Transform Infrared spectroscopy (FTIR)-based measurements made from a pilot-scale EPA research combustor (40-64 kW, natural gas-fired, 20% excess air). PFAS were introduced through the flame, and at post-flame locations along a time-temperature profile allowing for simulation of direct flame and non-flame injection, and examination of the sensitivity of PFAS destruction on temperature and free radical flame chemistry. Results indicate that CF4 is particularly difficult to destroy with DEs ranging from ~60 to 95% when introduced through the flame at increasing furnace loads. Due to the presence of lower energy C-H and C-C bonds to initiate molecular dissociation reactions, CHF3 and C2F6 were easier to destroy, exhibiting DEs >99% even when introduced post-flame. However, these lower bond energies may also lead to the formation of CF2 and CF3 radicals at thermal conditions unable to fully de-fluorinate these species and formation of fluorinated PICs. DEs determined by the model agreed well with the measurements for CHF3 and C2F6 but overpredicted DEs at high temperatures and underpredicted DEs at low temperatures for CF4. However, high DEs do not necessarily mean absence of PICs, with both model predictions and limited FTIR measurements indicating the presence of similar fluorinated PICs in the combustion emissions. The FTIR was able to provide real-time emission measurements and additional model development may improve prediction of PFAS destruction and PIC formation.Implications: The widespread use of PFAS for over 70 years has led to their presence in multiple environmental matrixes including human tissues. While the chemical and thermal stability of PFAS are related to their desirable properties, this stability means that PFAS are very slow to degrade naturally and potentially difficult to destroy completely through thermal treatment processes often used for organic waste destruction. In this applied combustion study, model PFAS compounds were introduced to a pilot-scale EPA research furnace. Real-time FTIR measurements were performed of the injected compound and trace products of incomplete combustion (PICs) at operationally relevant conditions, and the results were successfully compared to kinetic model predictions of those same PFAS destruction efficiencies and trace gas-phase PIC constituents. This study represents a significant potential enhancement in available tools to support effective management of PFAS-containing wastes.


Assuntos
Fluorocarbonos , Incineração , Fluorocarbonos/análise , Humanos , Incineração/métodos , Cinética , Temperatura
9.
Atmos Environ (1994) ; 2522021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33897265

RESUMO

This research used data mining approaches to better understand factors affecting the formation of secondary organic aerosol (SOA). Although numerous laboratory and computational studies have been completed on SOA formation, it is still challenging to determine factors that most influence SOA formation. Experimental data were based on previous work described by Offenberg et al. (2017), where volume concentrations of SOA were measured in 139 laboratory experiments involving the oxidation of single hydrocarbons under different operating conditions. Three different data mining methods were used, including nearest neighbor, decision tree, and pattern mining. Both decision tree and pattern mining approaches identified similar chemical and experimental conditions that were important to SOA formation. Among these important factors included the number of methyl groups for the SOA precursor, the number of rings for the SOA precursor, and the presence of dinitrogen pentoxide (N2O5).

10.
Artigo em Inglês | MEDLINE | ID: mdl-33889052

RESUMO

Wildland fires can emit substantial amounts of air pollution that may pose a risk to those in proximity (e.g., first responders, nearby residents) as well as downwind populations. Quickly deploying air pollution measurement capabilities in response to incidents has been limited to date by the cost, complexity of implementation, and measurement accuracy. Emerging technologies including miniaturized direct-reading sensors, compact microprocessors, and wireless data communications provide new opportunities to detect air pollution in real time. The U.S. Environmental Protection Agency (EPA) partnered with other U.S. federal agencies (CDC, NASA, NPS, NOAA, USFS) to sponsor the Wildland Fire Sensor Challenge. EPA and partnering organizations share the desire to advance wildland fire air measurement technology to be easier to deploy, suitable to use for high concentration events, and durable to withstand difficult field conditions, with the ability to report high time resolution data continuously and wirelessly. The Wildland Fire Sensor Challenge encouraged innovation worldwide to develop sensor prototypes capable of measuring fine particulate matter (PM2.5), carbon monoxide (CO), carbon dioxide (CO2), and ozone (O3) during wildfire episodes. The importance of using federal reference method (FRM) versus federal equivalent method (FEM) instruments to evaluate performance in biomass smoke is discussed. Ten solvers from three countries submitted sensor systems for evaluation as part of the challenge. The sensor evaluation results including sensor accuracy, precision, linearity, and operability are presented and discussed, and three challenge winners are announced. Raw solver submitted PM2.5 sensor accuracies of the winners ranged from ~22 to 32%, while smoke specific EPA regression calibrations improved the accuracies to ~75-83% demonstrating the potential of these systems in providing reasonable accuracies over conditions that are typical during wildland fire events.

11.
Atmos Environ (1994) ; 265: 1-8, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35153533

RESUMO

Wildland fire activity and associated emission of particulate matter air pollution is increasing in the United States over the last two decades due primarily to a combination of increased temperature, drought, and historically high forest fuel loading. The regulatory monitoring networks in the Unites States are mostly concentrated in larger population centers where anthropogenic air pollution sources are concentrated. Smaller population centers in areas more likely to be impacted by wildland fire smoke in many instances lack adequate observational air quality data. Several commercially available small form factor filter-based PM2.5 samplers (SFFFS) were evaluated under typical ambient and simulated near-to mid-field wildland fire smoke conditions to evaluate their accuracy for use in temporary deployments during prescribed and wildfire events. The performance of all the SFFFS tested versus the designated federal reference methods (FRM) was acceptable in determining PM2.5 concentration in both ambient (2.7-14.0 µg m-3) and chamber smoke environments (24.6-3044.6 µg m-3) with accuracies ranging from ~92 to 98%. However, only the ARA Instruments model N-FRM Sampler was found to provide PM2.5 mass measurement accuracies that meet FRM guideline performance specifications under both typical ambient (97.3 ± 1.9%) and simulated wildland fire conditions (98.2 ± 1.4%).

12.
Cardiovasc Toxicol ; 18(6): 569-578, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29943085

RESUMO

The health effects of individual criteria air pollutants have been well investigated. However, little is known about the health effects of air pollutant mixtures that more realistically represent environmental exposures. The present study was designed to evaluate the cardiac effects of inhaled simulated smog atmospheres (SA) generated from the photochemistry of either gasoline and isoprene (SA-G) or isoprene (SA-Is) in mice. Four-month-old female mice were exposed for 4 h to filtered air (FA), SA-G, or SA-Is. Immediately and 20 h after exposure, cardiac responses were assessed with a Langendorff preparation using a protocol consisting of 20 min of global ischemia followed by 2 h of reperfusion. Cardiac function was measured by index of left-ventricular developed pressure (LVDP) and cardiac contractility (dP/dt) before ischemia. Pre-ischemic LVDP was lower in mice immediately after SA-Is exposure (52.2 ± 5.7 cm H2O compared to 83.9 ± 7.4 cm H2O after FA exposure; p = 0.008) and 20 h after SA-G exposure (54.0 ± 12.7 cm H2O compared to 79.3 ± 7.4 cm H2O after FA exposure; p = 0.047). Pre-ischemic left ventricular contraction dP/dtmax was lower in mice immediately after SA-Is exposure (2025 ± 169 cm H2O/sec compared to 3044 ± 219 cm H2O/sec after FA exposure; p < 0.05) and 20 h after SA-G exposure (1864 ± 328 cm H2O/sec compared to 2650 ± 258 cm H2O/sec after FA exposure; p = 0.05). In addition, SA-G reduced the coronary artery flow rate 20 h after exposure compared to the FA control. This study demonstrates that acute SA-G and SA-Is exposures decrease LVDP and cardiac contractility in mice, indicating that photochemically-altered atmospheres affect the cardiovascular system.


Assuntos
Poluentes Atmosféricos/efeitos adversos , Butadienos/toxicidade , Gasolina/toxicidade , Hemiterpenos/toxicidade , Exposição por Inalação/efeitos adversos , Contração Miocárdica/efeitos dos fármacos , Smog/efeitos adversos , Disfunção Ventricular Esquerda/induzido quimicamente , Função Ventricular Esquerda/efeitos dos fármacos , Pressão Ventricular/efeitos dos fármacos , Animais , Cardiotoxicidade , Circulação Coronária/efeitos dos fármacos , Feminino , Preparação de Coração Isolado , Camundongos Endogâmicos C57BL , Disfunção Ventricular Esquerda/fisiopatologia
13.
Aerosol Sci Technol ; 52(1): 98-113, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29681677

RESUMO

Several low-volume inlets (flow rates ≤16.7 liters per minute (Lpm)) are commercially available as components of low-cost, portable ambient particulate matter samplers. Because the inlets themselves do not contain internal fractionators, they are often assumed to representatively sample "total" mass concentrations from the ambient air, independent of aerodynamic particle size and wind speed. To date, none of these so-called "TSP" inlets have been rigorously tested under controlled conditions. To determine their actual size-selective performance under conditions of expected use, wind tunnel tests of six commonly used omnidirectional, low-volume inlets were conducted using solid, polydisperse aerosols at wind speeds of 2, 8, and 24 km/hr. With the exception of axially-oriented, isokinetic sharp-edge nozzles operating at 5 and 10 Lpm, all low-volume inlets showed some degree of non-ideal sampling performance as a function of aerodynamic particle size and wind speed. Depending upon wind speed and assumed ambient particle size distribution, total mass concentration measurements were estimated to be negatively biased by as much as 66%. As expected from particle inertial considerations, inlet efficiency tended to degrade with increasing wind speed and particle size, although some exceptions were noted. The implications of each inlet's non-ideal behavior are discussed with regards to expected total mass concentration measurement during ambient sampling and the ability to obtain representative sampling for size ranges of interest, such as PM2.5 and PM10. Overall test results will aid in low-volume inlet selection and with proper interpretation of results obtained with their ambient field use.

14.
Environ Sci Technol ; 52(5): 3071-3080, 2018 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-29388764

RESUMO

This study was conducted to compare the cardiac effects of particulate matter (PM)- (SA-PM) and ozone(O3)-enhanced (SA-O3) smog atmospheres in mice. Based on our previous findings of filtered diesel exhaust we hypothesized that SA-O3 would cause greater cardiac dysfunction than SA-PM. Radiotelemetered mice were exposed to either SA-PM, SA-O3, or filtered air (FA) for 4 h. Heart rate (HR) and electrocardiogram were recorded continuously before, during and after exposure. Both SA-PM and SA-O3 increased heart rate variability (HRV) but only SA-PM increased HR. Normalization of responses to total hydrocarbons, gas-only hydrocarbons and PM concentration were performed to assess the relative contribution of each phase given the compositional variability. Normalization to PM concentration revealed that SA-O3 was more potent in increasing HRV, arrhythmogenesis, and causing ventilatory changes. However, there were no differences when the responses were normalized to total or gas-phase only hydrocarbons. Thus, this study demonstrates that a single exposure to smog causes cardiac effects in mice. Although the responses of SA-PM and SA-O3 are similar, the latter is more potent in causing electrical disturbances and breathing changes potentially due to the effects of irritant gases, which should therefore be accounted for more rigorously in health assessments.


Assuntos
Poluentes Atmosféricos , Ozônio , Animais , Atmosfera , Exposição por Inalação , Camundongos , Material Particulado , Smog
15.
Environ Sci Technol ; 52(5): 3054-3061, 2018 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-29382191

RESUMO

Early life nutritional deficiencies can lead to increased cardiovascular susceptibility to environmental exposures. Thus, the purpose of this study was to examine the effect of early life persistent vitamin D deficiency (VDD) on the cardiopulmonary response to a particulate matter-enhanced photochemical smog. Mice were fed a VDD or normal diet (ND) after weaning. At 17 weeks of age, mice were implanted with radiotelemeters to monitor electrocardiogram, heart rate (HR), and heart rate variability (HRV). Ventilatory function was measured throughout the diet before and after smog exposure using whole-body plethysmography. VDD mice had lower HR, increased HRV, and decreased tidal volume compared with ND. Regardless of diet, HR decreased during air exposure; this response was blunted by smog in ND mice and to a lesser degree in VDD. When compared with ND, VDD increased HRV during air exposure and more so with smog. However, smog only increased cardiac arrhythmias in ND mice. This study demonstrates that VDD alters the cardiopulmonary response to smog, highlighting the possible influence of nutritional factors in determining responses to air pollution. The mechanism of how VDD induces these effects is currently unknown, but modifiable factors should be considered when performing risk assessment of complex air pollution atmospheres.


Assuntos
Poluição do Ar , Deficiência de Vitamina D , Animais , Exposição Ambiental , Camundongos , Material Particulado , Smog
16.
Environ Sci Technol ; 52(5): 3062-3070, 2018 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-29384667

RESUMO

Air pollution is a diverse and dynamic mixture of gaseous and particulate matter, limiting our understanding of associated adverse health outcomes. The biological effects of two simulated smog atmospheres (SA) with different compositions but similar air quality health indexes were compared in a nonobese diabetic rat model (Goto-Kakizaki, GK) and three mouse immune models (house dust mite (HDM) allergy, antibody response to heat-killed pneumococcus, and resistance to influenza A infection). In GK rats, both SA-PM (high particulate matter) and SA-O3 (high ozone) decreased cholesterol levels immediately after a 4-h exposure, whereas only SA-O3 increased airflow limitation. Airway responsiveness to methacholine was increased in HDM-allergic mice compared with nonallergic mice, but exposure to SA-PM or SA-O3 did not significantly alter responsiveness. Exposure to SA-PM did not affect the IgM response to pneumococcus, and SA-O3 did not affect virus titers, although inflammatory cytokine levels were decreased in mice infected at the end of a 7-day exposure. Collectively, acute SA exposures produced limited health effects in animal models of metabolic and immune diseases. Effects of SA-O3 tended to be greater than those of SA-PM, suggesting that gas-phase components in photochemically derived multipollutant mixtures may be of greater concern than secondary organic aerosol PM.


Assuntos
Poluentes Atmosféricos , Ozônio , Animais , Atmosfera , Camundongos , Material Particulado , Ratos , Roedores , Smog
18.
Environ Sci Technol ; 52(5): 3045-3053, 2018 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-29406743

RESUMO

No study has evaluated the mutagenicity of atmospheres with a calculated air quality health index (AQHI). Thus, we generated in a UV-light-containing reaction chamber two simulated atmospheres (SAs) with similar AQHIs but different proportions of criteria pollutants and evaluated them for mutagenicity in three Salmonella strains at the air-agar interface. We continuously injected into the chamber gasoline, nitric oxide, and ammonium sulfate, as well as either α-pinene to produce SA-PM, which had a high concentration of particulate matter (PM): 119 ppb ozone (O3), 321 ppb NO2, and 1007 µg/m3 PM2.5; or isoprene to produce SA-O3, which had a high ozone (O3) concentration: 415 ppb O3, 633 ppb NO2, and 55 µg/m3 PM2.5. Neither PM2.5 extracts, NO2, or O3 alone, nor nonphoto-oxidized mixtures were mutagenic or cytotoxic. Both photo-oxidized atmospheres were largely direct-acting base-substitution mutagens with similar mutagenic potencies in TA100 and TA104. The mutagenic potencies [(revertants/h)/(mgC/m3)] of SA-PM (4.3 ± 0.4) and SA-O3 (9.5 ± 1.3) in TA100 were significantly different ( P < 0.0001), but the mutation spectra were not ( P = 0.16), being ∼54% C → T and ∼46% C → A. Thus, the AQHI may have some predictive value for the mutagenicity of the gas phase of air.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Atmosfera , Testes de Mutagenicidade , Mutagênicos , Material Particulado
19.
Environ Sci Technol ; 52(5): 3037-3044, 2018 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-29381868

RESUMO

The production of photochemical atmospheres under controlled conditions in an irradiation chamber permits the manipulation of parameters that influence the resulting air-pollutant chemistry and potential biological effects. To date, no studies have examined how contrasting atmospheres with a similar Air Quality Health Index (AQHI), but with differing ratios of criteria air pollutants, might differentially affect health end points. Here, we produced two atmospheres with similar AQHIs based on the final concentrations of ozone, nitrogen dioxide, and particulate matter (PM2.5). One simulated atmosphere (SA-PM) generated from irradiation of ∼23 ppmC gasoline, 5 ppmC α-pinene, 529 ppb NO, and 3 µg m-3 (NH4)2SO4 as a seed resulted in an average of 976 µg m-3 PM2.5, 326 ppb NO2, and 141 ppb O3 (AQHI 97.7). The other atmosphere (SA-O3) generated from 8 ppmC gasoline, 5 ppmC isoprene, 874 ppb NO, and 2 µg m-3 (NH4)2SO4 resulted in an average of 55 µg m-3 PM2.5, 643 ppb NO2, and 430 ppb O3 (AQHI of 99.8). Chemical speciation by gas chromatography showed that photo-oxidation degraded the organic precursors and promoted the de novo formation of secondary reaction products such as formaldehyde and acrolein. Further work in accompanying papers describe toxicological outcomes from the two distinct photochemical atmospheres.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Ozônio , Dióxido de Nitrogênio , Material Particulado
20.
Aerosol Sci Technol ; 52: 957-970, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35169350

RESUMO

Accurate development and evaluation of inlets for representatively collecting ambient particulate matter typically involves use of monodisperse particles in aerosol wind tunnels. However, the resource requirements of using monodisperse aerosols for inlet evaluation creates the need for more rapid and less-expensive techniques to enable determination of size-selective performance in aerosol wind tunnels. The goal of recent wind tunnel research at the U.S. EPA was to develop and validate the use of polydisperse aerosols which provide more rapid, less resource-intensive test results which still meet data quality requirements necessary for developing and evaluating ambient aerosol inlets. This goal was successfully achieved through comprehensive efforts regarding polydisperse aerosol generation, dispersion, collection, extraction, and analysis over a wide range of aerodynamic particle sizes. Using proper experimental techniques, a sampler's complete size-selective efficiency curve can be estimated with polydisperse aerosols in a single test, as opposed to the use of monodisperse aerosols which require conducting multiple tests using several different particle sizes. While this polydisperse aerosol technique is not proposed as a regulatory substitute for use of monodisperse aerosols, the use of polydisperse aerosols is advantageous during an inlet's development where variables of sampling flow rate and inlet geometry are often iteratively evaluated before a final inlet design can be successfully achieved. Complete Standard Operating Procedures for the generation, collection, and analysis of polydisperse calibration aerosols are available from EPA as downloadable files. The described experimental methods will be of value to other researchers during development of ambient sampling inlets and size-selective evaluation of the inlets in aerosol wind tunnels.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA