Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
CVIR Endovasc ; 7(1): 23, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38416319

RESUMO

BACKGROUND: The Viabahn stent graft has emerged as an integral tool for managing vascular diseases, but there is limited long-term data on its performance in emergency endovascular treatment. This study aimed to assess safety, technical success, and long-term efficacy of the Viabahn stent graft in emergency treatment of arterial injury. METHODS: We conducted a retrospective single tertiary centre analysis of patients who underwent Viabahn emergency arterial injury treatment between 2015 and 2020. Indication, intraoperative complications, technical and clinical success, and major adverse events at 30 days were evaluated. Secondary efficacy endpoints were the primary and secondary patency rates assessed by Kaplan-Meier analysis. RESULTS: Forty patients (71 ± 13 years, 19 women) were analyzed. Indications for Viabahn emergency treatment were extravasation (65.0%), arterio-venous fistula (22.5%), pseudoaneurysm (10.0%), and arterio-ureteral fistula (2.5%). No intraoperative adverse events occurred, technical and clinical success rates were 100%. One acute stent graft occlusion occurred in the popliteal artery on day 9, resulting in a 30-day device-related major-adverse-event rate of 2.5%. Median follow-up was 402 days [IQR, 43-1093]. Primary patency rate was 97% (95% CI: 94-100) in year 1, and 92% (95% CI: 86-98) from years 2 to 6. One stent graft occlusion occurred in the external iliac artery at 18 months; successful revascularization resulted in secondary patency rates of 97% (95% CI: 94-100) from years 1 to 6. CONCLUSION: Using Viabahn stent graft in emergency arterial injury treatment had 100% technical and clinical success rates, a low 30-day major-adverse-event rate of 2.5%, and excellent long-term patency rates.

2.
Diagn Interv Imaging ; 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38368176

RESUMO

PURPOSE: The purpose of this study was to evaluate the capabilities of photon-counting (PC) CT combined with artificial intelligence-derived coronary computed tomography angiography (PC-CCTA) stenosis quantification and fractional flow reserve prediction (FFRai) for the assessment of coronary artery disease (CAD) in transcatheter aortic valve replacement (TAVR) work-up. MATERIALS AND METHODS: Consecutive patients with severe symptomatic aortic valve stenosis referred for pre-TAVR work-up between October 2021 and June 2023 were included in this retrospective tertiary single-center study. All patients underwent both PC-CCTA and ICA within three months for reference standard diagnosis. PC-CCTA stenosis quantification (at 50% level) and FFRai (at 0.8 level) were predicted using two deep learning models (CorEx, Spimed-AI). Diagnostic performance for global CAD evaluation (at least one significant stenosis ≥ 50% or FFRai ≤ 0.8) was assessed. RESULTS: A total of 260 patients (138 men, 122 women) with a mean age of 78.7 ± 8.1 (standard deviation) years (age range: 51-93 years) were evaluated. Significant CAD on ICA was present in 126/260 patients (48.5%). Per-patient sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 96.0% (95% confidence interval [CI]: 91.0-98.7), 68.7% (95% CI: 60.1-76.4), 74.3 % (95% CI: 69.1-78.8), 94.8% (95% CI: 88.5-97.8), and 81.9% (95% CI: 76.7-86.4) for PC-CCTA, and 96.8% (95% CI: 92.1-99.1), 87.3% (95% CI: 80.5-92.4), 87.8% (95% CI: 82.2-91.8), 96.7% (95% CI: 91.7-98.7), and 91.9% (95% CI: 87.9-94.9) for FFRai. Area under the curve of FFRai was 0.92 (95% CI: 0.88-0.95) compared to 0.82 for PC-CCTA (95% CI: 0.77-0.87) (P < 0.001). FFRai-guidance could have prevented the need for ICA in 121 out of 260 patients (46.5%) vs. 97 out of 260 (37.3%) using PC-CCTA alone (P < 0.001). CONCLUSION: Deep learning-based photon-counting FFRai evaluation improves the accuracy of PC-CCTA ≥ 50% stenosis detection, reduces the need for ICA, and may be incorporated into the clinical TAVR work-up for the assessment of CAD.

3.
Rofo ; 196(1): 25-35, 2024 Jan.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-37793417

RESUMO

BACKGROUND: Photon-counting detector computed tomography (PCD-CT) is a promising new technology with the potential to fundamentally change workflows in the daily routine and provide new quantitative imaging information to improve clinical decision-making and patient management. METHOD: The contents of this review are based on an unrestricted literature search of PubMed and Google Scholar using the search terms "photon-counting CT", "photon-counting detector", "spectral CT", "computed tomography" as well as on the authors' own experience. RESULTS: The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCD-CT allows for the counting of every single photon at the detector level. Based on the identified literature, PCD-CT phantom measurements and initial clinical studies have demonstrated that the new technology allows for improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. CONCLUSION: For clinical practice, the potential benefits include fewer beam hardening artifacts, a radiation dose reduction, and the use of new or combinations of contrast agents. In particular, critical patient groups such as oncological, cardiovascular, lung, and head & neck as well as pediatric patient collectives benefit from the clinical advantages. KEY POINTS: · Photon-counting computed tomography (PCD-CT) is being used for the first time in routine clinical practice, enabling a significant dose reduction in critical patient populations such as oncology, cardiology, and pediatrics.. · Compared to conventional CT, PCD-CT enables a reduction in electronic image noise.. · Due to the spectral data sets, PCD-CT enables fully comprehensive post-processing applications.. CITATION FORMAT: · Hagen F, Soschynski M, Weis M et al. Photon-counting computed tomography - clinical application in oncological, cardiovascular, and pediatric radiology. Fortschr Röntgenstr 2024; 196: 25 - 34.


Assuntos
Radiologia , Tomografia Computadorizada por Raios X , Humanos , Criança , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Tórax , Imagens de Fantasmas , Pulmão
4.
Front Oncol ; 13: 1218517, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37655107

RESUMO

Thymic carcinomas are exceedingly rare and very aggressive malignancies of the anterior mediastinum. While thymomas exhibit a high association with paraneoplastic syndromes, these phenomena are a rarity in thymic carcinomas. In general, acanthotic syndromes such as acroceratosis neoplastica and acanthosis nigricans maligna are commonly observed as paraneoplastic phenomena in patients with carcinomas. In contrast, psoriasis vulgaris, another acanthotic disease, rarely occurs as a paraneoplasia. We report the case of a 36-year-old patient with progressive thymic carcinoma (undifferentiated carcinoma, T3N2M1a) and paraneoplastic psoriasis occurring ten months before the initial diagnosis of the carcinoma. Over the course of the disease, new psoriatic flares heralded relapse or progression of the carcinoma. To our knowledge, this is the first reported case of paraneoplastic psoriasis in thymic carcinoma.

5.
Diagn Interv Imaging ; 2023 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-37550171

RESUMO

PURPOSE: The purpose of this study was to assess the diagnostic capabilities of cardiac magnetic resonance (CMR) T2* mapping in detecting incidental hepatic and cardiac iron overload. MATERIALS AND METHODS: Patients with various clinical indications for CMR examination were consecutively included at a single center from January 2019 to April 2023. All patients underwent T2* mapping at 1.5 T in a single mid-ventricular short-axis as part of a comprehensive routine CMR protocol. T2* measurements were performed of the heart (using a region-of-interest in the interventricular septum) and the liver, categorized according to the severity of iron overload. The degree of cardiac iron overload was categorized as mild (15 ms < T2* < 20 ms), moderate (10 ms < T2* < 15 ms) and severe (T2* < 10 ms). The degree of hepatic iron overload was categorized as mild (4 ms < T2* < 8 ms), moderate (2 ms < T2* < 4 ms), severe (T2* < 2 ms). Image quality and inter-reader agreement were assessed using intraclass correlation coefficient (ICC). RESULTS: CMR examinations from 614 patients (374 men, 240 women) with a mean age of 50 ± 18 (standard deviation) years were fully evaluable. A total of 24/614 patients (3.9%) demonstrated incidental hepatic iron overload; of these, 22/614 patients (3.6%) had mild hepatic iron overload, and 2/614 patients (0.3%) had moderate hepatic iron overload. Seven out of 614 patients (1.1%) had incidental cardiac iron overload; of these, 5/614 patients (0.8%) had mild iron overload, 1/614 patients (0.2%) had moderate iron overload, and 1/614 patients (0.2%) had severe iron overload. Good to excellent inter-reader agreement was observed for the assessment of T2* values (ICC, 0.90 for heart [95% confidence interval: 0.88-0.91]; ICC, 0.91 for liver [95% confidence interval: 0.89-0.92]). CONCLUSION: Analysis of standard CMR T2* maps detects incidental cardiac and hepatic iron overload in 1.1% and 3.9% of patients, respectively, which may have implications for further patient management. Therefore, despite an overall low number of incidental abnormal findings, T2* imaging may be included in a standardized comprehensive CMR protocol.

6.
Diagnostics (Basel) ; 13(9)2023 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-37175026

RESUMO

(1) Background and Objectives: Dark-blood late gadolinium enhancement has been shown to be a reliable cardiac magnetic resonance (CMR) method for assessing viability and depicting myocardial scarring in ischemic cardiomyopathy. The aim of this study was to evaluate dark-blood LGE imaging compared with conventional bright-blood LGE for the detection of myocardial scarring in non-ischemic cardiomyopathies. (2) Materials and Methods: Patients with suspected non-ischemic cardiomyopathy were prospectively enrolled in this single-centre study from January 2020 to March 2023. All patients underwent 1.5 T CMR with both dark-blood and conventional bright-blood LGE imaging. Corresponding short-axis stacks of both techniques were analysed for the presence, distribution, pattern, and localisation of LGE, as well as the quantitative scar size (%). (3) Results: 343 patients (age 44 ± 17 years; 124 women) with suspected non-ischemic cardiomyopathy were examined. LGE was detected in 123 of 343 cases (36%) with excellent inter-reader agreement (κ 0.97-0.99) for both LGE techniques. Dark-blood LGE showed a sensitivity of 99% (CI 98-100), specificity of 99% (CI 98-100), and an accuracy of 99% (CI 99-100) for the detection of non-ischemic scarring. No significant difference in total scar size (%) was observed. Dark-blood imaging with mean 5.35 ± 4.32% enhanced volume of total myocardial volume, bright-blood with 5.24 ± 4.28%, p = 0.84. (4) Conclusions: Dark-blood LGE imaging is non-inferior to conventional bright-blood LGE imaging in detecting non-ischemic scarring. Therefore, dark-blood LGE imaging may become an equivalent method for the detection of both ischemic and non-ischemic scars.

7.
J Cancer Res Clin Oncol ; 149(9): 6753-6757, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36749424

RESUMO

PURPOSE: Epithelioid hemangioendothelioma (EHE) as a very rare malignant vascular tumor belongs to the heterogenous group of soft-tissue sarcomas. Depending on the clinical course of the disease, interdisciplinary treatment concepts are required, including surgery, radiotherapy and systemic cancer therapy. However, due to its uncommonness, standard treatment options are lacking so far, especially in advanced disease with distant metastases. METHODS AND RESULTS: Here we report on an unusual case of a patient with metastasized EHE showing long-term response to second line treatment with gemcitabine over almost 2 decades. Cancer genome sequencing of the patient's tumor tissue detected a NOTCH3 missense mutation which could provide an explanation for these clinical findings. NOTCH3 is known to be a mediator of resistance towards gemcitabine-based cancer treatment, at least in pancreatic cancer and non-small cell lung cancer. CONCLUSION: The observation that this missense mutation of NOTCH3 is associated with an increased response to treatment with gemcitabine in EHE can be used prospectively to assess NOTCH3 as potential biomarker for predicting therapy response to gemcitabine.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Hemangioendotelioma Epitelioide , Neoplasias Pulmonares , Humanos , Hemangioendotelioma Epitelioide/tratamento farmacológico , Hemangioendotelioma Epitelioide/genética , Hemangioendotelioma Epitelioide/patologia , Gencitabina , Mutação de Sentido Incorreto , Receptor Notch3/genética
9.
JACC Case Rep ; 6: 101694, 2023 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-36704065

RESUMO

We discuss the rare case of a myocardial abscess of the left ventricle in a 42-year-old man on immunosuppressive therapy after fulminant myocarditis. Multimodal imaging detected the myocardial abscess along with other septic emboli caused by infection with aspergillus fumigatus, which could be treated effectively with antimycotic strategies. (Level of Difficulty: Intermediate.).

10.
Arch Gynecol Obstet ; 307(3): 827-840, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36342536

RESUMO

PURPOSE: To limit the burden of long-term immunosuppression (IS) after uterus transplantation (UTx), removal of the uterine allograft is indicated after maximum two pregnancies. Hitherto this has required graft hysterectomy by laparotomy. Our objective was to demonstrate, as a proof of concept, the feasibility of less traumatic transplantectomy by total laparoscopic hysterectomy (TLH). PATIENT: A 37-year-old woman with uterovaginal agenesis due to Mayer-Rokitansky-Küster-Hauser syndrome (MRKHS) who had undergone neovaginoplasty at age 19 years prior to living-donor (LD) UTx in 10/2019 at age 35 years gave birth to a healthy boy by primary cesarean section in 06/2021. During pregnancy, she developed impaired renal function, with bilateral hydronephrosis, necessitating early allograft removal in 09/2021 to prevent chronic kidney disease, particularly during a potential second pregnancy. METHODS: Transplantectomy by TLH essentially followed standard TLH procedures. We paid meticulous attention to removing as much donor tissue as possible to prevent postoperative complications from residual donor tissue after stopping IS, as well as long-term vascular damage. RESULTS: TLH was performed successfully without the need to convert to open surgery. Surgical time was 90 min with minimal blood loss. No major complications occurred intra- or postoperatively and during the subsequent 9-month follow-up period. Kidney function normalized. CONCLUSIONS: To our knowledge, we report the first successful TLH-based removal of a uterine allograft in a primipara after LD UTx, thus demonstrating the feasibility of TLH in uterus recipients with MRKHS.


Assuntos
Cesárea , Laparoscopia , Masculino , Humanos , Feminino , Gravidez , Adulto Jovem , Adulto , Doadores Vivos , Útero/anormalidades , Histerectomia , Laparoscopia/métodos , Aloenxertos
12.
Diagnostics (Basel) ; 12(11)2022 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-36359572

RESUMO

Objectives: To systematically compare two modified Look-Locker inversion recovery (MOLLI) T1 mapping sequences and their impact on (1) myocardial T1 values native, (2) post-contrast and (3) extracellular volume (ECV). Methods: 200 patients were prospectively included for 1.5 T CMR for work-up of ischemic or non-ischemic cardiomyopathies. To determine native and post-contrast T1 for ECV calculation, two different T1 mapping MOLLI acquisition schemes, 5(3)3 (designed for native scans with long T1) and 4(1)3(1)2 (designed for post-contrast scans with short T1), were acquired in identical mid-ventricular short-axis slices. Both schemes were acquired in native and post-contrast scans. Results: Datasets from 163 patients were evaluated (age 55 ± 17 years; 38% female). Myocardial T1 native for 5(3)3 was 1017 ± 42 ms vs. 956 ± 40 ms for 4(1)3(1)2, with mean intraindividual difference −61 ms (p < 0.0001). Post-contrast myocardial T1 in patients was similar for both acquisition schemes, with 494 ± 48 ms for 5(3)3 and 490 ± 45 ms for 4(1)3(1)2 and mean intraindividual difference −4 ms. Myocardial ECV for 5(3)3 was 27.6 ± 4% vs. 27 ± 4% for 4(1)3(1)2, with mean difference −0.6 percentage points (p < 0.0001). Conclusions: The T1 MOLLI 5(3)3 acquisition scheme provides a reliable estimation of myocardial T1 for the clinically relevant range of long and short T1 values native and post-contrast. In contrast, the T1 MOLLI 4(1)3(1)2 acquisition scheme may only be used for post-contrast scans according to its designed purpose.

13.
J Clin Med ; 11(20)2022 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-36294324

RESUMO

The aim of this paper is to evaluate the diagnostic image quality of spectral dual-source photon-counting detector coronary computed tomography angiography (PCD-CCTA) for coronary artery disease in a multicenter study. The image quality (IQ), assessability, contrast-to-noise ratio (CNR), Agatston score, and radiation exposure were measured. Stenoses were quantified and compared with invasive coronary angiography, if available. A total of 92 subjects (65% male, age 58 ± 14 years) were analyzed. The prevalence of significant coronary artery disease (CAD) (stenosis ≥ 50%) was 17% of all patients, the range of the Agatston score was 0−2965 (interquartile range (IQR) 0−135). The IQ was very good (one, IQR one−two), the CNR was very high (20 ± 10), and 5% of the segments were rated non-diagnostic. The IQ and assessability were higher in proximal coronary segments (p < 0.001). Agatston scores up to 600 did not significantly affect the assessability of the coronary segments (p = 0.3). Heart rate influenced assessability only at a high-pitch mode (p = 0.009). For the invasive coronary angiography (ICA) subgroup (n = nine), the diagnostic performance for CAD per segment was high (sensitivity 92%, specificity 96%), although the limited number of patients who underwent both diagnostic modalities limits the generalization of this finding at this stage. PCD-CCTA provides good image quality for low and moderate levels of coronary calcifications.

14.
Front Cardiovasc Med ; 9: 989376, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36247463

RESUMO

Aims: Increased high-sensitive cardiac troponin I (hs-cTnI) levels are common in patients with acute ischemic stroke. However, only a minority demonstrates culprit lesions on coronary angiography, suggesting other mechanisms, e.g., inflammation, as underlying cause of myocardial damage. Late Gadolinium Enhancement (LGE)-cardiac magnetic resonance (CMR) with mapping techniques [T1, T2, extracellular volume (ECV)] allow the detection of both focal and diffuse myocardial abnormalities. We investigated the prevalence of culprit lesions by coronary angiography and myocardial tissue abnormalities by a comprehensive CMR protocol in troponin-positive stroke patients. Methods and results: Patients with troponin-positive acute ischemic stroke and no history of coronary artery disease were prospectively enrolled. Coronary angiography and CMR (LGE, T1 + T2 mapping, ECV) were performed within the first days of the acute stroke. Twenty-five troponin-positive patients (mean age 62 years, 44% females) were included. 2 patients (8%) had culprit lesions on coronary angiography and underwent percutaneous coronary intervention. 13 patients (52%) demonstrated LGE: (i) n = 4 ischemic, (ii) n = 4 non-ischemic, and (iii) n = 5 ischemic AND non-ischemic. In the 12 LGE-negative patients, mapping revealed diffuse myocardial damage in additional 9 (75%) patients, with a high prevalence of increased T2 values. Conclusions: Our data show a low prevalence of culprit lesions in troponin-positive stroke patients. However, > 50% of the patients demonstrated myocardial scars (ischemic + non-ischemic) by LGE-CMR. Mapping revealed additional myocardial abnormalities (mostly inflammatory) in the majority of LGE-negative patients. Therefore, a comprehensive CMR protocol gives important insights in the etiology of troponin which might have implications for the further work-up of troponin-positive stroke patients.

15.
Radiologie (Heidelb) ; 62(11): 954-959, 2022 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-36056155

RESUMO

BACKGROUND: Diagnostic work-up for myocarditis and inflammatory cardiomyopathy is challenging for its different aetiologies, phenotypes and stages. METHODICAL INNOVATIONS AND CHALLENGES: Cardiac PET/MRI is an excellent tool for myocardial tissue characterization with MRI as well as for diagnosis of active myocardial inflammation with PET. The combination of MRI and PET is rather synergistic than only summative: myocardial changes detected by MRI can be differentiated with PET to (potentially still reversible) active inflammation vs. chronic and inactive (irreversible) scars. The strengths of a hybrid PET/MRI can show to advantage in cardiac sarcoidosis with potentially coexistent active and chronic involvement. Good dietary preparation with a low-carb diet is essential to warrant sufficient suppression of myocardial glucose uptake for robust cardiac PET in context of inflammatory cardiomyopathy. RECOMMENDATIONS: Hybrid cardiac PET/MRI to diagnose inflammatory cardiomyopathy and further differentiation in acute vs. chronic processes is feasible. This could be demonstrated in cardiac involvement of sarcoidosis.


Assuntos
Miocardite , Sarcoidose , Humanos , Miocardite/diagnóstico por imagem , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons , Imageamento por Ressonância Magnética , Sarcoidose/diagnóstico por imagem , Inflamação/diagnóstico por imagem
16.
J Clin Med ; 11(17)2022 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-36078976

RESUMO

(1) Objectives: To discriminate biopsy-proven myocarditis (chronic vs. healed myocarditis) and to differentiate from dilated cardiomyopathy (DCM) using cardiac magnetic resonance (CMR). (2) Methods: A total of 259 consecutive patients (age 51 ± 15 years; 28% female) who underwent both endomyocardial biopsy (EMB) and CMR in the years 2008−2021 were evaluated. According to right-ventricular EMB results, patients were divided into either chronic (n = 130, 50%) or healed lymphocytic myocarditis (n = 60, 23%) or DCM (n = 69, 27%). The CMR protocol included functional, strain, and late gadolinium enhancement (LGE) imaging, T2w imaging, and T2 mapping. (3) Results: Left-ventricular ejection fraction (LV-EF) was higher, and the indexed end-diastolic volume (EDV) was lower in myocarditis patients (chronic: 42%, median 96 mL/m²; healed: 49%, 86 mL/m²) compared to the DCM patients (31%, 120 mL/m²), p < 0.0001. Strain analysis demonstrated lower contractility in DCM patients vs. myocarditis patients, p < 0.0001. Myocarditis patients demonstrated a higher LGE prevalence (68% chronic; 59% healed) than the DCM patients (45%), p = 0.01. Chronic myocarditis patients showed a higher myocardial edema prevalence and ratio (59%, median 1.3) than healed myocarditis (23%, 1.3) and DCM patients (13%, 1.0), p < 0.0001. T2 mapping revealed elevated values more frequently in chronic (90%) than in healed (21%) myocarditis and DCM (23%), p < 0.0001. T2 mapping yielded an AUC of 0.89 (sensitivity 90%, specificity 76%) in the discrimination of chronic from healed myocarditis and an AUC of 0.92 (sensitivity 86%, specificity 91%) in the discrimination of chronic myocarditis from DCM, both p < 0.0001. (4) Conclusions: Multiparametric CMR imaging, including functional parameters, LGE and T2 mapping, may allow differentiation of chronic from healed myocarditis and DCM and therefore help to optimize patient management in this clinical setting.

17.
J Clin Med ; 11(17)2022 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-36079039

RESUMO

(1) Background: Compared to acute myocarditis in the initial phase, detection of subacute myocarditis with cardiac magnetic resonance (CMR) parameters can be challenging due to a lower degree of myocardial inflammation compared to the acute phase. (2) Objectives: To systematically evaluate non-invasive CMR imaging parameters in acute and subacute myocarditis. (3) Methods: 48 patients (age 37 (IQR 28−55) years; 52% female) with clinically suspected myocarditis were consecutively included. Patients with onset of symptoms ≤2 weeks prior to 1.5T CMR were assigned to the acute group (n = 25, 52%), patients with symptom duration >2 to 6 weeks were assigned to the subacute group (n = 23, 48%). CMR protocol comprised morphology, function, 3D-strain, late gadolinium enhancement (LGE) imaging and mapping (T1, ECV, T2). (4) Results: Highest diagnostic performance in the detection of subacute myocarditis was achieved by ECV evaluation either as single parameter or in combination with T1 mapping (applying a segmental or global increase of native T1 > 1015 ms and ECV > 28%), sensitivity 96% and accuracy 91%. Compared to subacute myocarditis, acute myocarditis demonstrated higher prevalence and extent of LGE (AUC 0.76) and increased T2 (AUC 0.66). (5) Conclusions: A comprehensive CMR approach allows reliable diagnosis of clinically suspected subacute myocarditis. Thereby, ECV alone or in combination with native T1 mapping indicated the best performance for diagnosing subacute myocarditis. Acute vs. subacute myocarditis is difficult to discriminate by CMR alone, due to chronological connection and overlap of pathologic findings.

18.
Rofo ; 194(7): 763-770, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35081651

RESUMO

PURPOSE: Evaluation of machine learning-based fully automated artery-specific coronary artery calcium (CAC) scoring software, using semi-automated software as a reference. METHODS: A total of 505 patients underwent non-contrast-enhanced calcium scoring computed tomography (CSCT). Automated, machine learning-based software quantified the Agatston score (AS), volume score (VS), and mass score (MS) of each coronary artery [right coronary artery (RCA), left main (LM), circumflex (CX) and left anterior descending (LAD)]. Identified CAC of readers who annotated the data with semi-automated software served as a reference standard. Statistics included comparisons of evaluation time, agreement of identified CAC, and comparisons of the AS, VS, and MS of the reference standard and the fully automated algorithm. RESULTS: The machine learning-based software correlated strongly with the reference standard for the AS, VS, and MS (Spearman's rho > 0.969) (p < 0.001), with excellent agreement (ICC > 0.919) (p < 0.001). The mean assessment time of the reference standard was 59 seconds (IQR 39-140) and that of the automated algorithm was 5.9 seconds (IQR 3.9-16) (p < 0.001). The Bland-Altman plots mean difference and 1.96 upper and lower limits of agreement for all arteries combined were: AS 0.996 (1.33 to 0.74), VS 0.995 (1.40 to 0.71), and MS 0.995 (1.35 to 0.74). The mean bias was minimal: 0.964-1.0429. Risk class assignment showed high accuracy for the AS in total (weighed κ = 0.99) and for each individual artery (κ = 0.96-0.99) with corresponding correct risk group assignment in 497 of 505 patients (98.4 %). CONCLUSION: The fully automated artery-specific coronary calcium scoring algorithm is a time-saving procedure and shows excellent correlation and agreement compared with the clinically established semi-automated approach. KEY POINTS: · Very high correlation and agreement between fully automatic and semi-automatic calcium scoring software.. · Less time-consuming than conventional semi-automatic methods.. · Excellent tool for artery-specific calcium scoring in a clinical setting.. CITATION FORMAT: · Winkelmann MT, Jacoby J, Schwemmer C et al. Fully Automated Artery-Specific Calcium Scoring Based on Machine Learning in Low-Dose Computed Tomography Screening. Fortschr Röntgenstr 2022; 194: 763 - 770.


Assuntos
Cálcio , Doença da Artéria Coronariana , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Aprendizado de Máquina , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
20.
JACC Cardiovasc Imaging ; 15(3): 445-456, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34656480

RESUMO

OBJECTIVES: The purpose of this study was to investigate the diagnostic value of simultaneous hybrid cardiac magnetic resonance (CMR) and 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) for detection and differentiation of active (aCS) from chronic (cCS) cardiac sarcoidosis. BACKGROUND: Late gadolinium enhancement (LGE) CMR and FDG-PET are both established imaging techniques for the detection of CS. However, there are limited data regarding the value of a comprehensive simultaneous hybrid CMR/FDG-PET imaging approach that includes CMR mapping techniques. METHODS: Forty-three patients with biopsy-proven extracardiac sarcoidosis (median age: 48 years, interquartile range: 37-57 years, 65% male) were prospectively enrolled for evaluation of suspected CS. After dietary preparation for suppression of myocardial glucose metabolism, patients were evaluated on a 3-T hybrid PET/MR scanner. The CMR protocol included T1 and T2 mapping, myocardial function, and LGE imaging. We assumed aCS if PET and CMR (ie, LGE or T1/T2 mapping) were both positive (PET+/CMR+), cCS if PET was negative but CMR was positive (PET-/CMR+), and no CS if patients were CMR negative regardless of PET findings. RESULTS: Among the 43 patients, myocardial glucose uptake was suppressed successfully in 36 (84%). Hybrid CMR/FDG-PET revealed aCS in 13 patients (36%), cCS in 5 (14%), and no CS in 18 (50%). LGE was present in 14 patients (39%); T1 mapping was abnormal in 10 (27%) and T2 mapping abnormal in 2 (6%). CS was diagnosed based on abnormal T1 mapping in 4 out of 18 CS patients (22%) who were LGE negative. PET FDG uptake was present in 17 (47%) patients. CONCLUSIONS: Comprehensive simultaneous hybrid CMR/FDG-PET imaging is useful for the detection of CS and provides additional value for identifying active disease. Our results may have implications for enhanced diagnosis as well as improved identification of patients with aCS in whom anti-inflammatory therapy may be most beneficial.


Assuntos
Cardiomiopatias , Miocardite , Sarcoidose , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/patologia , Meios de Contraste , Feminino , Fluordesoxiglucose F18 , Gadolínio , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons/métodos , Valor Preditivo dos Testes , Compostos Radiofarmacêuticos , Sarcoidose/diagnóstico por imagem , Sarcoidose/patologia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...