Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Kardiol Pol ; 75(1): 48-54, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27391910

RESUMO

BACKGROUND: Bisoprolol is one of the most widely used beta-blockers characterised by cardioselectivity, and it has no intrinsic sympathomimetic activity. It is commonly used in the treatment of coronary heart disease and heart failure. AIM: The aim of study was to assess the bioequivalence of the film-coated tablets containing 2.5 mg of bisoprolol (Bisocard® - the medicinal product) to the original medicinal product (Concor Cor 2.5® - the reference). METHODS: A randomised, open-label, two-period, crossover, single-dose, relative bioavailability study was conducted in fasted healthy Caucasian volunteers. A single 10-mg oral dose (four tablets of 2.5 mg) of the test or reference product was followed by a 14-day wash-out period, after which the subjects received the alternative product. Blood was sampled within a period of 60 h post administration in pre-specified time points. Bisoprolol concentrations were determined by a validated LC-MS/MS method. The products were considered bioequivalent if the 90% confidence interval (CI) of the log-transformed geometric mean ratios (test vs. reference) for AUC(0-t), AUC(0-∞), and Cmax were within 80-125% limits. Adverse events were monitored during the study based on the subject claims and clinical parameters. RESULTS: Twenty-six healthy male and female volunteers (mean age ca. 29 years; body mass index 22.7 kg/m²) were in-cluded in the study, and 24 completed the clinical part. The geometric mean ratios (test/reference) for the log-transformed AUC(0-t), AUC(0-∞), and Cmax were 95.16% (90% CI 92.52-97.87%), 95.08% (90% CI 92.40-97.83%), and 100.00% (90% CI 94.83-105.45%), respectively. There were no significant differences in the pharmacokinetic parameters between the test and reference formulations. No serious adverse events were reported. CONCLUSIONS: The results of this single-dose study in healthy Caucasian volunteers indicate that Bisocard®; 2.5 mg film-coated tablets are bioequivalent to the reference product - Concor Cor 2.5®; 2.5 mg film-coated tablets. Both products had similar safety profile and have been well tolerated.


Assuntos
Bisoprolol/farmacocinética , Comprimidos , Adolescente , Adulto , Disponibilidade Biológica , Bisoprolol/administração & dosagem , Bisoprolol/sangue , Bisoprolol/uso terapêutico , Cromatografia Líquida , Doença das Coronárias/tratamento farmacológico , Estudos Cross-Over , Composição de Medicamentos , Feminino , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Espectrometria de Massas em Tandem , Equivalência Terapêutica , População Branca , Adulto Jovem
2.
J Pharm Biomed Anal ; 100: 184-189, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25168217

RESUMO

A sensitive liquid chromatographic-tandem mass spectrometric method was developed and validated to study the pharmacokinetics of a low dose of azithromycin in human plasma. The sample preparation was based on liquid-liquid extraction with the low volume of methyl t-butyl ether. The chromatographic separation was performed on a Symmetry C18 column (50×2.1mm, 3.5µm). Gradient elution with ammonium acetate-acetonitrile and ammonium acetate-methanol was applied. Positive electrospray ionisation tandem mass spectrometry in the multiple reaction monitoring mode was used for the detection of azithromycin. The influence of a major metabolite, including the possibility of its back-conversion, on the quantification of azithromycin was evaluated. Isotope labelled azithromycin was used as the internal standard. The calibration curve was linear in the range of 0.5-250.0ng/mL. The new validated method was successfully applied to a pharmacokinetic study in humans following a single 100mg oral dose.


Assuntos
Antibacterianos/administração & dosagem , Antibacterianos/sangue , Azitromicina/administração & dosagem , Azitromicina/sangue , Cromatografia Líquida/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Administração Oral , Antibacterianos/farmacocinética , Azitromicina/farmacocinética , Biotransformação , Calibragem , Humanos , Modelos Lineares , Extração Líquido-Líquido , Valor Preditivo dos Testes , Padrões de Referência , Reprodutibilidade dos Testes
3.
Talanta ; 102: 75-8, 2012 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-23182577

RESUMO

New chromatographic method for the enantioseparation of (R,S)-tamsulosin and the determination of (R)- and (S)-tamsulosin was developed with the aid of amylose tris(3,5-dimethylphenylcarbamate) stationary phase. The method was compared to the known procedure for tamsulosin enantioseparation on cellulose tris(3,5-dimethylphenyl carbamate). Careful validation of both methods allowed to prove advantages of the new procedure: significantly better resolution as well as twice better sensitivity. The method was applied to quantification of (R)- and (S)-tamsulosin contents in prolonged release Apo-Tamis 0.4 mg hard capsules (Apotex Europe B.V) and Omnic Ocas 0.4 mg coated tablets (Astellas).


Assuntos
Antagonistas de Receptores Adrenérgicos alfa 1/análise , Amilose/análogos & derivados , Fenilcarbamatos/química , Sulfonamidas/análise , Antagonistas de Receptores Adrenérgicos alfa 1/química , Amilose/química , Cromatografia Líquida de Alta Pressão/métodos , Estereoisomerismo , Sulfonamidas/química , Tansulosina
4.
Int J Clin Pharmacol Ther ; 50(12): 909-19, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23006443

RESUMO

OBJECTIVE: The aim of the study was to investigate the bioavailability of a generic formulation of 10-mg bisoprolol film coated tablets (test) as compared to that of a branded formulation (reference) at the same strength to determine bioequivalence and to apply for regulatory approval. The secondary objective of the study was to evaluate tolerability of both formulations. METHODS: A randomized, crossover, open-label, 2-period, single-dose, comparative study was conducted in healthy white volunteers in fasting conditions. A single oral dose administration of the test or reference formulation was followed by a 14-day wash-out period. Blood samples were collected up to 60 hours after dosing. The bisoprolol concentrations in plasma samples were determined using a validated LC-MS/MS method. The formulations were considered bioequivalent if 90% CI of geometric mean ratios (test/reference) for AUC0-t, AUC0-∞ and Cmax were within the range 80.00 - 25.00%. Adverse events were monitored throughout the study based on the clinical parameters and volunteer reports. RESULTS: Healthy male and female subjects participating in the study had a median (range) age of 23 (20 - 43), weight of 68 kg (52 - 84), height of 172 cm (157 - 184), and BMI of 23.1 kg/m2 (19.3 - 24.9). The 26 consented volunteers have been included and 24 of them completed the clinical part of the study. The geometric mean test/referenceratios (90% CI) for AUC0-t, AUC0-∞ and Cmax were 104.12% (100.52 - 107.85%), 104.05% (100.49 - 107.75%) and 107.91% (103.04 - 112.99%), respectively. All 90% CI were embraced by the 80.00 - 25.00% acceptance interval. No serious adverse events were reported. A total number of 6 non-serious, moderate adverse events were registered, including headache and vomiting in one subject. CONCLUSIONS: The results of the single-dose study in healthy white volunteers indicated that the film-coated tablets of Bisocard® 10 mg manufactured by ICN Polfa Rzeszów S.A. (test formulation) are bioequivalent to those of Concor 10® manufactured by Merck KGaA (reference formulation). Both formulations were well tolerated.


Assuntos
Antagonistas de Receptores Adrenérgicos beta 1/farmacocinética , Bisoprolol/farmacocinética , Adulto , Bisoprolol/efeitos adversos , Química Farmacêutica , Estudos Cross-Over , Jejum , Feminino , Humanos , Masculino , Comprimidos com Revestimento Entérico , Equivalência Terapêutica
5.
Acta Pol Pharm ; 69(6): 1356-63, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23285702

RESUMO

The aim of the study was to investigate the bioavailability of a generic product of 500 mg cefuroxime axetil film-coated tablets (test) as compared to that of a branded product (reference) at the same strength to determine bioequivalence and to apply for regulatory approval. The secondary objective of the study was to evaluate tolerability of both products. A double blinded, randomized, crossover, two-period, single-dose, comparative study was conducted in Caucasian healthy volunteers in fasting conditions. A single oral dose administration of the test or reference product was followed by 7-day wash-out period. The cefuroxime concentration was determined using a validated HPLC-UV method. The results of the single-dose study in healthy volunteers indicated that the film-coated tablets of Tarsime 500 mg manufactured by Tarchominskie Zaklady Farmaceutyczne Polfa S.A. (test product) are bioequivalent to those of Zinnat manufactured by GlaxoSmithKline Export Ltd. (reference product). Both products were well tolerated.


Assuntos
Antibacterianos/farmacocinética , Cefuroxima/análogos & derivados , Adolescente , Adulto , Cefuroxima/efeitos adversos , Cefuroxima/farmacocinética , Estudos Cross-Over , Método Duplo-Cego , Feminino , Humanos , Masculino , Comprimidos , Equivalência Terapêutica
6.
J Chromatogr B Analyt Technol Biomed Life Sci ; 879(21): 1905-10, 2011 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-21641878

RESUMO

Exemestane, irreversible steroidal aromatase inhibitor, acts as a false substrate for aromatase enzyme and significantly lowers circulating estrogen concentrations in postmenopausal women with hormone-sensitive breast cancer. A sensitive bioanalytical method was developed and validated to study pharmacokinetics of exemestane. The method was based on liquid-liquid extraction of exemestane with methyl t-butyl ether followed by reversed-phase liquid chromatography. Positive electrospray ionization tandem mass spectrometry in multiple reaction monitoring mode was applied for detection of exemestane. Anastrozole was used as internal standard. Calibration curve, fitted to 1/x² weighted linear regression model, was linear in the range of 0.1-40.0 ng/mL. Intra-run precision and accuracy were 1.80-3.17% and 103.4-111.5%, respectively. Inter-run precision and accuracy measured within 3 days were 3.37-4.19% and 101.8-109.6%, respectively. Extraction recoveries of exemestane and internal standard were 79.7-86.2% and 82.9-83.6%, respectively. The method was fully validated and may be applied to pharmacokinetic studies in humans after a single dose administration of 25mg exemestane tablets.


Assuntos
Androstadienos/sangue , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Anastrozol , Antineoplásicos/sangue , Humanos , Modelos Lineares , Nitrilas/sangue , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray , Triazóis/sangue
7.
J Pharm Biomed Anal ; 44(2): 356-67, 2007 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-17475434

RESUMO

Gas and liquid chromatography-mass spectrometry (GC-MS, LC-MS) methods for the determination of angiotensin-converting enzyme inhibitors (ACEIs) and their metabolites in biological material have been reviewed. Since 1980s those hyphenated techniques have been applied to quantitate ACE inhibitors and the dynamic increase in the number of relevant publications can be observed in recent years. Although most of the methods available in the literature were analyses of plasma or serum, assays of blood and urine were also included. Additionally, sample pretreatment methods, separation conditions and ionization modes were overviewed. Some information on chemical structures, cis-trans izomerization and stability of compounds in question was also included. Most of the reported methods were successfully applied to the pharmacokinetic studies in humans.


Assuntos
Inibidores da Enzima Conversora de Angiotensina/análise , Animais , Líquidos Corporais/química , Cromatografia , Cromatografia Líquida de Alta Pressão , Estabilidade de Medicamentos , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Espectrometria de Massas , Padrões de Referência , Estereoisomerismo
8.
J Pharm Biomed Anal ; 41(2): 533-9, 2006 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-16406450

RESUMO

A new, sensitive, specific and reproducible method for determination of clopidogrel metabolite (SR26334) in human plasma has been developed. After liquid-liquid extraction on Chem Elut cartridges with dichloromethane, samples were quantified using reversed-phase high performance liquid chromatography with mass detection. The determination was performed on a Luna C18, 3 microm (75 mmx4.6 mm i.d.) column with an acetonitrile-water-formic acid mixture (60:40:0.1, v/v/v) as a mobile phase. The flow rate was set at 0.2 mL/min. Repaglinide was chosen as an internal standard and the time of analysis was 12 min. For SR26334 the limits of detection and quantification were 7.5 ng/mL and 20 ng/mL, respectively, and the calibration curve was linear up to 3000 ng/mL. The extraction recovery of SR26334 from plasma was within the range of 85-90%. The method has been successfully used to study clopidogrel metabolite pharmacokinetics in healthy volunteers.


Assuntos
Inibidores da Agregação Plaquetária/sangue , Ticlopidina/análogos & derivados , Cromatografia Líquida de Alta Pressão/métodos , Estabilidade de Medicamentos , Humanos , Espectrometria de Massas , Inibidores da Agregação Plaquetária/farmacocinética , Reprodutibilidade dos Testes , Temperatura , Ticlopidina/sangue , Ticlopidina/farmacocinética
10.
Artigo em Inglês | MEDLINE | ID: mdl-14670740

RESUMO

Methods for determination of genistein and its four new analogues in culture media have been developed to support studies on their potential anticancer activities. The investigated compounds were extracted from the media using liquid-liquid extraction with appropriate solvent. After evaporation of organic solvents each of the dry extracts was reconstituted in appropriate mobile phase. Reversed-phase HPLC was applied to quantitative determining of tested compounds. The methods are specific, sensitive and technically simple. They were used to evaluate concentration level of investigated compounds in experiments with human promyelocytic leukemia cells (HL-60 cell line).


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Meios de Cultura/química , Genisteína/análise , Calibragem , Células HL-60 , Humanos , Sensibilidade e Especificidade , Solventes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...