Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cureus ; 16(2): e54239, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38362036

RESUMO

PURPOSE: To assess how intraoperative macroscopical anterior cruciate ligament (ACL) findings affect perioperative procedures, biomarkers, and postoperative anterior-posterior (AP) laxity and range of motion (ROM) after cruciate-retaining (CR) total knee arthroplasty (TKA) and to determine how chronic ACL deficiency may affect postoperative inflammatory biomarker, AP laxity, and ROM. METHODS: A total of 121 patients with varus knee osteoarthritis without a history of ACL injury who underwent ATTUNE® (DePuy Synthes, Warsaw, IN) CR TKA were analyzed. Intraoperative ACL findings were stratified into intact, damaged, and diminished, according to the tension by probing, synovial coverage, and vascularity. C-reactive protein (CRP) levels were examined at one, seven, and 14 days after surgery. Knee AP laxity measurements using Kneelax 3 (Monitored Rehab Systems, Haarlem, The Netherlands) and postoperative knee ROM were also compared. RESULTS: One-way ANOVA showed significant differences in CRP levels examined one day after surgery observed between the three groups (8.4 (3.8), 9.8 (4.3), and 13.2 (7.7) mg/dL, respectively; P = 0.018), with post hoc analysis showing that CRP levels one day after surgery were significantly greater in the diminished group than in the intact and damaged groups (P = 0.012 and 0.023, respectively). AP laxity in 30° of knee flexion was observed between the three groups (5.4 (2.3), 5.8 (2.5), and 7.1 (2.8) mm, respectively; P = 0.039), with post hoc analysis showing that AP laxity in 30° of knee flexion was significantly greater in the diminished group than in the intact group (P = 0.038). Knee ROM showed no significant differences. CONCLUSION: Intraoperative ACL diminishment was associated with higher CRP one day after surgery and midrange AP laxity one year after surgery.

2.
Clin Biomech (Bristol, Avon) ; 109: 106076, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37634465

RESUMO

BACKGROUND: Medial open wedge high tibial osteotomy is currently the most common osteotomy, but its complication is an increased posterior tibial slope over time. However, no study has clarified whether the plate position of medial open wedge high tibial osteotomy could reduce the increase in posterior tibial slope after cyclic loading. METHODS: Fourteen porcine bones were biomechanically evaluated by performing medial open wedge high tibial osteotomy and placing TOMOFIX medially and anteromedially. Cyclic testing was performed to investigate the posterior tibial slope over time for medial open wedge high tibial osteotomy with medial or anteromedial plate. The displacement along the mechanical axis during cyclic testing from 10 to 100th, 100-500th, 500-1000th, 1000-1500th, and 1500-2000th cycles, and changes in anterior and posterior gaps after 2000 cycles were compared between plate position. FINDINGS: There were no significant differences in displacement. A significant difference was found in posterior gap changes (-0.20 ± 0.84 mm in group of using medial plate, 1.07 ± 0.82 mm in group of using anteromedial plate) (P = 0.014), but none was found in anterior gap changes. INTERPRETATION: Medial plate placement in medial open wedge high tibial osteotomy resulted in significantly less increased posterior tibial slope than anteromedial plate placement after cyclic loading.


Assuntos
Osteoartrite do Joelho , Tíbia , Suínos , Animais , Tíbia/cirurgia , Osteotomia/métodos , Placas Ósseas , Osteoartrite do Joelho/cirurgia
3.
Arthrosc Sports Med Rehabil ; 5(3): e629-e635, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37388876

RESUMO

Purpose: To investigate whether the biomechanical properties of the healed superficial medial collateral ligament (sMCL) repaired by augmentation vary depending on the material properties of the suture augmentation. Methods: In 8 of 10 porcines (16 hindlimbs), the sMCL was detached from the femoral attachment using a scalpel under intubated general anesthesia. sMCL repair was performed using an ultra-high-molecular-weight polyethylene (UHMWPE) tape for the right hindlimbs and polyester tape (PE) for the left hindlimbs. They were sacrificed at 4 weeks postoperatively. The remaining 2 animals were assigned to the native control group (left and right hindlimb; n = 4). All connective tissues and suture augmentation, except for the repaired sMCL, were removed, and their biomechanical properties were evaluated. Results: No significant differences were observed in the upper yield load (PE group, 247.4 ± 116.0 N; UHMWPE group, 279.9 ± 95.7 N; and sham group, 231.6 ± 50.6 N; P = .70), maximum yield load (PE group, 310.1 ± 166.1 N; UHMWPE group, 334.6 ± 95.2 N; and sham group, 290.9 ± 42.3 N; P = .84), linear stiffness (PE group, 43.3 ± 16.5 N/mm; UHMWPE group, 52.0 ± 28.2 N/mm; and sham group, 44.7 ± 7.2 N/mm; P = .66), and elongation at failure (PE group, 9.4 ± 4.3 mm; UHMWPE group, 9.1 ± 2.7 mm; and sham group, 10.1 ± 2.1 mm; P = .89). Statistical analysis of failure modes showed no significant difference between the groups (P = .21). Conclusions: The material properties of suture augmentation used for sMCL repair did not significantly influence length changes during cyclic loading, postoperative structural properties, or failure modes. Clinical Relevance: The results of this study provide valuable information regarding the efficacy of suture augmentation repair regardless of the materials used.

4.
Trauma Case Rep ; 42: 100716, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36281423

RESUMO

Two elderly female patients with Kellgren-Lawrence grade 4 knee osteoarthritis (KOA) having varus knee deformity and retained hardware for internal fixation in either femur or tibia underwent total knee arthroplasty (TKA) using 3D templating and patient-specific instrumentation (PSI). TKA was performed to treat KOA by minimally removing or without removing the retained hardware for the internal fixation of distal femoral or tibial diaphyseal fractures. Throughout a 2-year follow-up period, no superficial or deep infection was observed. In additions, no radiological symptoms of suspected component loosening were observed. Furthermore, both patients can currently walk without using crutches. 3D templating and PSI in primary TKA for patients with retained hardware for internal fixation of femoral or tibial fractures are considered suitable treatment options for reducing surgical invasion.

5.
Telemed Rep ; 3(1): 49-54, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35720445

RESUMO

Background: Hospital-related coronavirus disease 2019 (COVID-19) infection is of utmost concern among patients and health care workers. Expanding the use of telemedicine may be required in daily outpatient practice; however, the acceptance of telemedicine use is still low, especially among older patients. In an orthopedic practice, no studies have investigated potential factors that can contribute to changes in the acceptance of using telemedicine. Focusing on older outpatients with knee osteoarthritis (KOA), we hypothesized that a drastic surge in the number of patients with COVID-19 could trigger changes in attitudes regarding the acceptance of telemedicine use. Methods: A baseline survey was conducted after the first wave of the COVID-19 pandemic in Japan to obtain information on the willingness to use telemedicine among patients aged ≥70 years who regularly consulted an orthopedic surgeon for KOA. A follow-up survey was subsequently conducted during the third wave of the pandemic period to assess changes in the acceptance of telemedicine use in response to the rapidly increasing number of patients with COVID-19. We compared the difference in acceptance of telemedicine use and knee pain status between the baseline and follow-up surveys. Results: In the baseline survey, 11 of 43 patients (25.6%) responded that they would be willing to use telemedicine. In the follow-up survey, patients' acceptance of telemedicine did not change, with the exact same number and percentage of patients who were willing to use telemedicine as in the baseline survey, despite that ∼20% of patients reported improvement in their knee pain status. Discussion: Our findings indicate that older outpatients with KOA did not change their willingness to accept use of telemedicine, even with a drastically increased risk of hospital-related transmission of a potentially fatal infectious disease when visiting a hospital. The acceptance of telemedicine use among older patients might not be less sensitive to external environmental factors but instead might be more sensitive to patients' personal factors, such as anxiety for information technology and resistance to changes in their lifestyle.

6.
Technol Health Care ; 30(5): 1147-1154, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35599511

RESUMO

BACKGROUND: Total knee arthroplasty (TKA) is a widely performed procedure to alleviate pain and restore function of patients with end-stage knee osteoarthritis. OBJECTIVE: The study aim was to determine if tibia-first (TF) total knee arthroplasty (TKA) using a novel computer-assisted surgery (CAS) system can yield better anterior and posterior (AP) knee stability. METHODS: Patients with knee osteoarthritis with obvious varus knee who met the indication for and underwent TKA from May 2019 to November 2020 were included. Forty-one measured resection (MR)-TKAs and 32 TF-TKAs were compared. The varus-valgus ligament balance and joint tension at a joint center-gap setting equal to the tibial-baseplate thickness were measured, and appropriate polyethylene inserts with 0∘, 30∘, 45∘, 60∘, 90∘, and 120∘ of knee flexion were placed. A Kneelax 3 arthrometer was used to measure knee AP laxity in the postoperative anesthetized patients with 30∘ and 90∘ of knee flexion. RESULTS: The horizontal gap balance was significantly closer in the TF-TKA group than the MR-TKA group for 0∘, 30∘, 45∘, and 60∘ of knee flexion. In contrast, no significant differences were observed for 90∘ and 120∘ of knee flexion. No significant differences in joint-gap tensions among all knee-flexion angles were observed. Translation was significantly smaller in the TF-TKA group than the MR-TKA group for AP laxity with 30∘ of knee flexion (8.8 ± 2.9 mm vs. 10.7 ± 3.1 mm, P= 0.0079). In contrast, no significant AP laxity was observed with 90∘ of knee flexion (7.2 ± 2.8 mm vs. 7.2 ± 3.5 mm). CONCLUSION: TF-TKA using a novel CAS system provided better AP knee stability with close to horizontal gap balances.


Assuntos
Artroplastia do Joelho , Instabilidade Articular , Osteoartrite do Joelho , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Computadores , Humanos , Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Polietilenos , Amplitude de Movimento Articular , Tíbia/cirurgia
7.
J Orthop Sci ; 27(4): 876-880, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34090779

RESUMO

BACKGROUND: Femoral neck system (FNS) is an implant for patients with femoral neck fracture. It has superior angular and rotatory stability; it is less invasive because of its established locking plate system. To the best of our knowledge, there are no studies yet concerning the clinical outcomes of elderly patients with femoral neck fracture who have been treated using the FNS. METHODS: Data of patients with femoral neck fracture aged >65 years and who had undergone internal fixation with the FNS and other implants were retrospectively analyzed in this study. The follow-up period was a minimum of six months between January 2006 and November 2020. In total, 52 patients were included in the clinical evaluations, using the FNS (group F) was 25 and using other implants (group O) was 27. Outcome measurements were surgical time, the amount of blood loss, union rate and the cases that underwent reoperation. RESULTS: The average surgical time in the group F was 42 ± 13 min (range: 26-83 min) and was shorter than that in the group O (53 ± 21 min, range: 13-111 min, P = 0.032). The average blood loss in the group F was calculated to 36 ± 25 g (range: 0-91 g), while it was 41 ± 40 g (range: 0-169 g) in group O. No significant difference among the groups. The union rate of the group F was 100%, and the reoperation rate of the group F was significantly less than that of the group O (0% vs 22%, P = 0.023). CONCLUSION: Internal fixation using the FNS can be an alternative option with shorter surgical time and lower reoperation rate for elderly patients with femoral neck fracture.


Assuntos
Fraturas do Colo Femoral , Idoso , Placas Ósseas , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/etiologia , Fraturas do Colo Femoral/cirurgia , Colo do Fêmur , Fixação Interna de Fraturas/efeitos adversos , Humanos , Estudos Retrospectivos , Resultado do Tratamento
8.
J Knee Surg ; 35(11): 1199-1203, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33482672

RESUMO

A wide variety of fixation methods have been reported to fix anterior cruciate ligament (ACL) tibial avulsion fractures, but there have been no studies into the fixation of these fractures with ultra-high molecular weight polyethylene (UHMWPE) suture tape as an alternative to conventional thread. Type III ACL tibial avulsion fractures were created in 20 skeletally immature porcine knees. All specimens were randomized into two treatment groups: (1) pullout repair using no. 2 suture fixation and (2) pullout repair using UHMWPE suture tape fixation. The specimens were tested cyclically (20 cycles, 0-40 N, 100 mm/min) in the direction of the native ACL and loaded to failure (100 mm/min) on a tensile tester. Statistically significant differences between the structural properties (displacement, upper yield load, maximum load, linear stiffness, and elongation at failure) under cyclic loading and single-cycle loading were analyzed. Displacement during cyclic testing was 1.56 ± 1.03 mm in the UltraBraid group and 0.99 ± 0.48 mm in the SUTURETAPE group, with no significant differences found between the groups (p = 0.13). There were no significant differences in upper yield load (161.9 ± 68.9 N in the UltraBraid group, 210.4 ± 60.1 N in the SUTURETAPE group, p = 0.11), linear stiffness (14.7 ± 4.7N/mm in the UltraBraid group, 18.1 ± 7.9 N/mm in the SUTURETAPE group, p = 0.27), or elongation at failure (20.1 ± 8.0 mm in the UltraBraid group, 21.5 ± 7.2 mm in the SUTURETAPE group, p = 0.69). On the other hand, significant differences were observed in maximum load in the SUTURETAPE group (219.7 ± 89.2 N in the UltraBraid group, 319.3 ± 92.6 N in the SUTURETAPE group, p = 0.025).


Assuntos
Fratura Avulsão , Fraturas da Tíbia , Animais , Ligamento Cruzado Anterior/cirurgia , Fenômenos Biomecânicos , Fratura Avulsão/cirurgia , Polietilenos , Técnicas de Sutura , Suturas , Suínos , Fraturas da Tíbia/cirurgia
9.
J Knee Surg ; 35(10): 1132-1137, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33482675

RESUMO

Few studies have determined whether a femoral bone tunnel could be created behind the resident's ridge by using a transtibial (TT) technique-single bundle (SB)-anterior cruciate ligament (ACL) reconstruction. The aim of this study was to clarify (1) whether it is possible to create a femoral bone tunnel behind the resident's ridge by using the TT technique with SB ACL reconstruction, (2) to define the mean tibial and femoral tunnel angles during anatomic SB ACL reconstruction, and (3) to clarify the tibial tunnel inlet location when the femoral tunnel is created behind resident's ridge. Arthroscopic TT-SB ACL reconstruction was performed on 36 patients with ACL injuries. The point where 2.4-mm guide pin was inserted was confirmed, via anteromedial portal, to consider a location behind the resident's ridge. Then, an 8-mm diameter femoral tunnel with a 4.5-mm socket was created. Tunnel positions were evaluated by using three-dimensional computed tomography (3D-CT) 1 week postoperatively. Quadrant method and the resident's ridge on 3D-CT were evaluated to determine whether femoral tunnel position was anatomical. Radiological evaluations of tunnel positions yielded mean ( ± standard deviation) X- and Y-axis values for the tunnel centers: femoral tunnel, 25.2% ± 5.1% and 41.6% ± 10.2%; tibial tunnel, 49.2% ± 3.5%, and 31.5% ± 7.7%. The bone tunnels were anatomically positioned in all cases. The femoral tunnel angle relative to femoral axis was 29.4 ± 5.5 degrees in the coronal view and 43.5 ± 8.0 degrees in the sagittal view. The tibial tunnel angle relative to tibial axis was 25.5 ± 5.3 degrees in the coronal view and 52.3 ± 4.6 degrees in the sagittal view. The created tibial bone tunnel inlet had an average distance of 13.4 ± 2.7 mm from the medial tibial joint line and 9.7 ± 1.7 mm medial from the axis of the tibia. Femoral bone tunnel could be created behind the resident's ridge with TT-SB ACL reconstruction. The tibial bone tunnel inlet averaged 13.4 mm from the medial tibial joint line and 9.7 mm medial from the tibia axis.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Fêmur/cirurgia , Humanos , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Tomografia Computadorizada por Raios X
10.
Cureus ; 13(3): e14013, 2021 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-33889458

RESUMO

Transtibial pull-out repair is routinely performed to treat medial meniscal posterior root tear (MMPRT). However, data on the postoperative histological evaluation of the repaired medial meniscus posterior attachment after the procedure is scarce. In this report, we present a histological evaluation of the harvested specimen of a patient who underwent unicompartmental knee arthroplasty (UKA) approximately two years and six months after MMPRT transtibial pull-out repair. The patient was a 75-year-old female. Her X-ray showed Kellgren-Lawrence classification grade II and her MRI revealed MMPRT. Arthroscopic transtibial pull-out repair was performed two months after the onset, and her condition was fine two years after the operation. However, her knee pain gradually worsened, and UKA was performed two years and six months after the initial surgery. The medial meniscus posterior root was continuous from the resected tibia. Tissue specimens were prepared and evaluated. There were Sharpey's fiber-like tissues in the tibial bone tunnel. The medial meniscus posterior attachment showed a four-layer structure of ligaments, uncalcified fibrocartilage, calcified fibrocartilage, and subchondral bone zone. The structures were observed 2,000 ㎛ medially from the bone tunnel. The results revealed that the reconstructed graft after a transtibial pull-out repair for the medial meniscus posterior root showed different histological findings compared with the native posterior root and similar to the anterior root of the medial meniscus.

11.
Arthrosc Sports Med Rehabil ; 3(6): e1967-e1973, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34977655

RESUMO

PURPOSE: To investigate the biomechanical efficacy of medial meniscal ramp lesion (MMRL) repair in anterior cruciate ligament (ACL) reconstruction regarding the graft protection effect after cyclic loading. METHODS: Specimens were randomized into 2 groups: (1) ACL reconstruction with unaddressed MMRL (Group U; n = 10), and (2) ACL reconstruction with repaired MMRL (Group R; n = 12). The specimens were tested cyclically (2,000 cycles, 0-40 N, 100 mm/min) in the direction of the native ACL and loaded to failure (100 mm/min) on a tensile tester. Statistically significant differences between the structural properties (length changes and anterior translations at the 100th, 500th, 1,000th, 1,500th, and 2,000th cycles, upper yield load, maximum load, linear stiffness, and elongation at failure) under cyclic loading and single-cycle loading were analyzed. RESULTS: There were no significant differences in length changes and anterior translations at the 100th, 500th, 1,000th, 1,500th, and 2,000th cycles. There were no significant differences in upper yield load (82.4 ± 31.2 N in Group U, 90.0 ± 38.5 N in Group R, P = .62), maximum load (109.9 ± 28.6 N in Group U, 124.0 ± 56.4 N in Group R, P = .48), linear stiffness (12.1 ± 4.7N/mm in Group U, 12.5 ± 4.3 N/mm in Group R, P = .84), or elongation at failure (13.5 ± 7.3 mm in Group U, 16.6 ± 7.5 mm in Group R, P = .30). CONCLUSIONS: Simultaneous MMRL repair at the time of ACL reconstruction did not decrease length changes and anterior translations during cyclic loading. In addition, simultaneous MMRL repair at the time of ACL reconstruction did not contribute to better postoperative structural properties. CLINICAL RELEVANCE: Simultaneous MMRL repair at the time of ACL reconstruction does not show a graft protective effect after cyclic loading. Graft elongation may occur during early rehabilitation.

12.
J Orthop Sci ; 26(5): 915-918, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32948405

RESUMO

BACKGROUND: Superficial medial collateral ligament (sMCL) injury is common, but there are no in vivo studies describing the biomechanical efficacy of anatomic repair with internal bracing for grade 3 injuries. METHODS: We used a porcine model to evaluate the efficacy of internal bracing using an artificial ligament for the early repair of acute, grade 3 sMCL injuries. Sixteen male castrated pigs were randomly assigned to a repair group: (1) anatomic repair using two suture anchors (Group R; n = 9) or (2) anatomic repair with internal bracing augmentation (Group IB; n = 7). The left knees were allocated to a sham surgery group (Group S; n = 16). All animals were sacrificed 4 weeks after surgery. The right and left femur-sMCL-tibia complexes were mounted on a tensile tester and stretched to failure using the same conditions as preconditioning at a cross-head speed of 50 mm/min. The internal bracing in Group IB was removed prior to the biomechanical testing. The failure mode and structural properties (upper yield load, maximum load, linear stiffness, and elongation at failure) were determined. RESULTS: Significant differences in failure mode were observed among the three groups. All sMCLs repaired with just the suture anchors (Group R) were avulsed from the femoral attachment, while most of the sMCLs repaired with internal bracing augmentation (Group IB) exhibited mid-substance tears (Group R vs Group IB, P = 0.0023). In Group S, 14 sMCLs were avulsed from the femoral attachment and two were avulsed from the tibial attachment (Group IB vs Group S, P < 0.001). No significant difference was observed between Group R and Group S. There were no significant differences in the upper yield load, maximum load, linear stiffness, or elongation at failure among the groups. CONCLUSIONS: Loading of an artificial ligament for internal bracing did not result in better structural properties of the repaired sMCL itself.


Assuntos
Braquetes , Ligamentos Colaterais , Animais , Masculino , Fenômenos Biomecânicos , Cadáver , Fêmur , Suínos , Tíbia
13.
Geriatr Orthop Surg Rehabil ; 11: 2151459320979974, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33335789

RESUMO

BACKGROUND: There is no report yet on the application of telemedicine in orthopedic practice in Japan. With a focus on patients with KOA, we investigated the willingness of patients to use telemedicine by assessing factors such as the patient's age, smartphone possession, hospital visiting time, and severity of KOA. METHODS: Data of patients who regularly consulted orthopedic surgeons at our institutions from April 2020 to June 2020 were retrospectively analyzed using an electronic medical database. The patients were diagnosed with KOA according to clinical and radiological findings, according to the Kellgren-Lawrence (KL) classification. included were patients with KOA with KL classification above grade 2. All patients were asked: 1) whether they were willing to use telemedicine (Yes or No), 2) the reason why they answered Yes, 3) the reason why they answered No, 4) if they possessed a smartphone, 5) their numeric rating scale for pain at their last outpatient visit after the Sars-CoV-2 epidemic emerged, and 6) the time required for visiting hospital from their house. Patients were stratified into 2 groups depending on whether they answered Yes (Group Y) or No (group N). Comparisons between the groups concerning smartphone possession, NRS pain, hospital visiting times, and distribution of KL grade were made. RESULTS: Only 36.7% of the patients with KOA said they were willing to use telemedicine. The average age of group Y was significantly younger than that of group N (67.9 ± 9.1 vs 73.1 ± 8.0, P = 0.0026) and the cutoff age was 70.0 years. In addition, the rate of smartphone possession was significantly higher in group Y than in group N (82.5% vs 34.5%, P < 0.001). Hospital visit times and the severity of KOA did not differ between the groups. CONCLUSION: Age is a barrier to the adoption of telemedicine.

14.
Pediatr Int ; 59(5): 627-632, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28402006

RESUMO

Herein we describe the case of a 1-month-old boy with acute viral myocarditis, who presented with two kinds of paroxysmal supraventricular tachycardia, and who was cured after medical treatment. He was brought to the emergency room with poor feeding due to fever. On the third day of hospitalization, a narrow QRS tachycardia (180-200 beats/min) was detected. Echocardiography showed a high echoic area at the atrial septum around the atrioventricular node. The patient was clinically diagnosed with acute myocarditis. The narrow QRS tachycardia was diagnosed as incessant junctional ectopic tachycardia. The patient was treated with propranolol and landiolol. The frequency of the tachycardia decreased, but a different narrow QRS tachycardia was detected on the 15th day of hospitalization on electrocardiogram (220 beats/min), which was ascribed to atrioventricular nodal re-entrant tachycardia. Atenolol was effective for the tachycardia. At 2 years follow up, cardiac function was normal and tachycardia had not recurred.


Assuntos
Infecções por Coxsackievirus/diagnóstico , Enterovirus Humano B/isolamento & purificação , Miocardite/diagnóstico , Taquicardia Supraventricular/etiologia , Infecções por Coxsackievirus/complicações , Humanos , Lactente , Masculino , Miocardite/complicações , Miocardite/virologia , Taquicardia Ectópica de Junção/diagnóstico , Taquicardia Ectópica de Junção/etiologia , Taquicardia Supraventricular/diagnóstico
18.
Virus Res ; 165(1): 34-45, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22248643

RESUMO

Street rabies viruses are field isolates known to be highly neurotropic. However, the viral elements related to their pathogenicity have yet to be identified at the nucleotide or amino acid level. Here, through 30 passages in mouse neuroblastoma NA cells, we have established an attenuated variant of street rabies virus strain 1088, originating from a rabid woodchuck followed by 2 passages in the brains of suckling mice. The variant, 1088-N30, was well adapted to NA cells and highly attenuated in adult mice after intramuscular (i.m.) but not intracerebral (i.c.) inoculations. 1088-N30 had seven nucleotide substitutions, and the R196S mutation of the G protein led to an additional N-glycosylation. Street viruses usually possess one or two N-glycosylation sites on the G protein, 1088 has two, while an additional N-glycosylation site is observed in laboratory-adapted strains. We also established a cloned variant 1088-N4#14 by limiting dilution. Apart from the R196S mutation, 1088-N4#14 possessed only one amino acid substitution in the P protein, which is found in several field isolates. 1088-N4#14 also efficiently replicated in NA cells and was attenuated in adult mice after i.m. inoculations, although it was more pathogenic than 1088-N30. The spread of 1088-N30 in the brain was highly restricted after i.m. inoculations, although the pattern of 1088-N4#14's spread was intermediate between that of the parental 1088 and 1088-N30. Meanwhile, both variants strongly induced humoral immune responses in mice compared to 1088. Our results indicate that the additional N-glycosylation is likely related to the reduced pathogenicity. Taken together, we propose that the number of N-glycosylation sites in the G protein is one of the determinants of the pathogenicity of street rabies viruses.


Assuntos
Glicoproteínas/metabolismo , Vírus da Raiva/metabolismo , Vírus da Raiva/patogenicidade , Raiva/virologia , Proteínas Virais/metabolismo , Motivos de Aminoácidos , Sequência de Aminoácidos , Animais , Sequência de Bases , Linhagem Celular Tumoral , Regulação para Baixo , Feminino , Glicoproteínas/química , Glicoproteínas/genética , Glicosilação , Humanos , Marmota/virologia , Camundongos , Dados de Sequência Molecular , Vírus da Raiva/genética , Inoculações Seriadas , Proteínas Virais/química , Proteínas Virais/genética , Virulência , Cultura de Vírus
19.
Chem Commun (Camb) ; 47(30): 8632-4, 2011 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-21720623

RESUMO

Electron transfer behavior of 1,2-diphenyl-o-carborane was investigated by cyclic voltammetry (CV). In the presence of 1,2-dibromo-1,2-diphenylethane, a significant catalytic current was observed. The macroscale electrocatalytic reduction of the dibromide using a catalytic amount (1 mol%) of the carborane mediator afforded the desired trans-stilbene in excellent yield.


Assuntos
Compostos de Boro/química , Catálise , Técnicas Eletroquímicas , Transporte de Elétrons , Oxirredução , Estilbenos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...