1.
J Vac Sci Technol A ; 38(6): 063208, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33281279

RESUMO

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ∼3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ∼5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ∼4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. We also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

2.
Chemosphere ; 80(8): 881-7, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20570315

RESUMO

The chemical states of boron in coal fly ash, which may control its leaching into the environment, were investigated by focused-ion-beam time-of-flight secondary ion mass spectrometry (FIB-TOF-SIMS) and satellite-transition magic angle spinning nuclear magnetic resonance (STMAS NMR) spectroscopy. The distribution of boron on the surface and in the interior of micron-sized fly ash particles was directly observed by FIB-TOF-SIMS. Coordination numbers of boron and its bonding with different atoms from particles of bulk samples were investigated by STMAS NMR. Boron in coal fly ash with relatively poor leaching characteristics appears as trigonal BO(3) and coexists with Ca and Fe at the outer layer of every particle and inside CaO-MgO particles. In contrast, boron in coal fly ash with better leaching characteristics appears as CaO- or MgO-trigonal BO(3) and tetragonal BO(4), and it is distributed only on the outer surface of each ash particle without showing any correlation with a particular element.


Assuntos
Boro/química , Carbono/química , Espectroscopia de Ressonância Magnética , Material Particulado/química , Espectrometria de Massa de Íon Secundário , Boro/análise , Cinza de Carvão , Resíduos Perigosos/análise , Tamanho da Partícula
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...