Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 641
Filtrar
1.
Eur Heart J Digit Health ; 5(3): 356-362, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38774365

RESUMO

Aims: Electroanatomical mapping (EAM) systems are essential for the treatment of cardiac arrhythmias. The EAM system is usually operated by qualified staff or field technical engineers from the control room. Novel remote support technology allows for remote access of EAM via online services. Remote access increases the flexibility of the electrophysiological lab, reduces travel time, and overcomes hospital access limitations especially during the COVID-19 pandemic. Here, we report on the feasibility and safety of EAM remote access for cardiac ablation procedures. Methods and results: Mapping and ablation were achieved by combining the EnsiteX™ EAM system and the integrated Ensite™ Connect Remote Support software, together with an integrated audiovisual solution system for remote support (Medinbox). Communication between the operator and the remote support was achieved using an incorporated internet-based common communication platform (Zoom™), headphones, and high-resolution cameras. We investigated 50 remote access-assisted consecutive electrophysiological procedures from September 2022 to February 2023 (remote group). The data were compared with matched patients (n = 50) with onsite support from the control room (control group). The median procedure time was 100 min (76, 120; remote) vs. 86 min (60, 110; control), P = 0.090. The procedural success (both groups 100%, P = 0.999) and complication rate (remote: 2%, control: 0%, P = 0.553) were comparable between the groups. Travel burden could be reduced by 11 280 km. Conclusion: Remote access for EAM was feasible and safe in this single-centre study. Procedural data were comparable to procedures with onsite support. In the future, this new solution might have a great impact on facilitating electrophysiological procedures.

2.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38647070

RESUMO

AIMS: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients' comfort, and to reduce vascular access-related complications. The aim of the present study is to compare the safety and efficacy of using a VCS to achieve haemostasis following single-shot PVI to the actual standard of care [figure-of-eight suture and manual compression (MC)]. METHODS AND RESULTS: This is a prospective, multicentre, randomized, controlled, open-label trial performed at three German centres. Patients were randomized 1:1 to undergo haemostasis either by means of VCS (VCS group) or of a figure-of-eight suture and MC (F8 group). The primary efficacy endpoint was the time to ambulation, while the primary safety endpoint was the incidence of major periprocedural adverse events until hospital discharge. A total of 125 patients were randomized. The baseline characteristics were similar between the groups. The VCS group showed a shorter time to ambulation [109.0 (82.0, 160.0) vs. 269.0 (243.8, 340.5) min; P < 0.001], shorter time to haemostasis [1 (1, 2) vs. 5 (2, 10) min; P < 0.001], and shorter time to discharge eligibility [270 (270, 270) vs. 340 (300, 458) min; P < 0.001]. No major vascular access-related complication was reported in either group. A trend towards a lower incidence of minor vascular access-related complications on the day of procedure was observed in the VCS group [7 (11.1%) vs. 15 (24.2%); P = 0.063] as compared to the control group. CONCLUSION: Following AF ablation, the use of a VCS results in a significantly shorter time to ambulation, time to haemostasis, and time to discharge eligibility. No major vascular access-related complications were identified. The use of MC and a figure-of-eight suture showed a trend towards a higher incidence of minor vascular access-related complications.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Técnicas de Sutura , Humanos , Fibrilação Atrial/cirurgia , Feminino , Masculino , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Técnicas de Sutura/efeitos adversos , Idoso , Resultado do Tratamento , Alemanha , Fatores de Tempo , Dispositivos de Oclusão Vascular , Deambulação Precoce , Técnicas Hemostáticas/instrumentação
3.
Thromb Haemost ; 2024 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-38555641

RESUMO

OBJECTIVE AND BACKGROUND: Data on incidence of in-hospital pulmonary embolisms (PE) after catheter ablation (CA) are scarce. To gain further insights, we sought to provide new findings through case-based analyses of administrative data. METHODS: Incidences of PE after CA of supraventricular tachycardias (SVT), atrial fibrillation (AF), atrial flutter (AFlu), and ventricular tachycardias (VT) in three German tertiary centers between 2005 and 2020 were determined and coded by the G-DRG (German Diagnosis Related Groups System) and OPS (German Operation and Procedure Classification) systems. An administrative search was performed with a consecutive case-based analysis. RESULTS: Overall, 47,344 ablations were analyzed (10,037 SVT; 28,048 AF; 6,252 AFlu; 3,007 VT). PE occurred in 14 (0.03%) predominantly female (n = 9; 64.3%) patients with a mean age of 55.3 ± 16.9 years, body mass index 26.2 ± 5.1 kg/m2, and left ventricular ejection fraction of 56 ± 13.6%. PE incidences were 0.05% (n = 5) for SVT, 0.02% (n = 5) for AF, and 0.13% (n = 4) for VT ablations. No patient suffered PE after AFlu ablation. Five patients (35.7%) with PE after CA had no prior indication for oral anticoagulation (OAC). Preprocedural international normalized ratio in PE patients was 1.2 ± 0.5. Most patients with PE following CA presented with symptoms the day after the procedure (n = 9) after intraprocedural heparin application of 12,943.2 ± 5,415.5 IU. PE treatment included anticoagulation with either phenprocoumon (n = 5) or non-vitamin K-dependent OAC (n = 9). Two patients with PE died after VT/AF ablation, respectively. The remaining patients were discharged without sequels. CONCLUSION: Over a 15-year period, incidence of PE after ablation is low, particularly low in patients with ablation for AF/AFlu. This is most likely due to stricter anticoagulation management in these patients compared with those receiving SVT/VT ablation procedures and could argue for continuation of OAC prior to ablation. Optimizing periprocedural anticoagulation management should be subject of further prospective trials.

4.
Heart ; 110(11): 800-807, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38388469

RESUMO

OBJECTIVES: The association of pulmonary hypertension (PH) with the outcome after mitral transcatheter edge-to-edge repair (M-TEER) focusing on the new ESC/ERS guidelines definition for PH. BACKGROUND: PH is frequently found in patients with mitral regurgitation and is associated with lower survival rates. Recent studies were based on echocardiographic parameters, but results based on invasive haemodynamics differentiating distinct types of PH using the new definition for PH are missing. METHODS: 449 consecutive M-TEER-treated patients from December 2009 to February 2015 were included in this retrospective analysis. All patients were stratified by the distinct types of PH (no PH, precapillary PH, isolated postcapillary PH, combined post-PH and precapillary PH) according to the definitions of the ESC/ERS guidelines for the diagnosis of PH from 2015 (meanPA cut-off <25 mm Hg, pulmonary capillary wedge pressure (PCWP) cut-off ≤15 mm Hg, diastolic pulmonary gradient cut-off ≥7 mm Hg or pulmonary vascular resistance (PVR) >3 WU) and 2022 (meanPA cut-off ≤20 mm Hg, PCWP cut-off ≤15 mm Hg, PVR cut-off ≥3 WU). RESULTS: Patients with any type of PH (2015: meanPA cut-off 25 mm Hg; 2022: meanPA cut-off >20 mm Hg) showed a higher risk of death after M-TEER compared with patients with no PH (2015: HR 1.61 (95% CI 1.25 to 2.07); p<0.001 and 2022: HR 2.09 (95% CI 1.54 to 2.83); p<0.001). Based on the new PH definition, each PH subgroup showed a lower survival after M-TEER compared with patients with no PH. Echocardiographic estimated systolic PAP showed a correlation with invasively measured mean pulmonary artery pressure (mPAP) (r=0.29, p<0.001) and systolic pulmonary arterial pressure (r=0.34,p<0.001). Cox-regression analysis showed higher invasive diastolic, systolic and mean pulmonary pressures were associated with higher all-cause mortality (p<0.001). In addition, invasive measured higher right atrial pressure, lower pulmonary arterial compliance, higher PVR and higher wedge pressure were identified as predictors of all-cause mortality after M-TEER. CONCLUSIONS: The new PH definition discriminates PH groups and mortality better than the old definition. The lower threshold of mPAP of 20mmHg improved prognostication in this cohort of patients.


Assuntos
Cateterismo Cardíaco , Hipertensão Pulmonar , Insuficiência da Valva Mitral , Humanos , Hipertensão Pulmonar/fisiopatologia , Hipertensão Pulmonar/mortalidade , Hipertensão Pulmonar/diagnóstico , Feminino , Masculino , Estudos Retrospectivos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/complicações , Idoso , Cateterismo Cardíaco/métodos , Resultado do Tratamento , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Pressão Propulsora Pulmonar/fisiologia , Pessoa de Meia-Idade , Fatores de Risco , Hemodinâmica/fisiologia
5.
Int J Cardiol Heart Vasc ; 50: 101325, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38419611

RESUMO

Background: Very high-power short-duration (vHP-SD) radiofrequency (RF) ablation of atrial fibrillation (AF) treatment by pulmonary vein isolation (PVI) aims for safer, more effective and faster procedures. Although acute efficacy and safety for PVI was recently shown data on chronic PVI durability is limited. Here chronic PVI durability was evaluated during repeat electrophysiological procedures in patients after initial vHP-SD and conventional RF based PVI. Methods: A total of 25 consecutive patients with repeat left atrial procedures after initial vHP-SD based PVI were included in this study. Twenty-five patients with previous conventional RF based PVI and repeat left atrial procedures served as control (control group). Results: For index procedures the median RF time was 328 (277, 392) seconds (vHP-SD) and 1470 (1310, 1742) seconds (control); p < 0.001, the median procedure time was 55 (53, 68) minutes (vHP-SD) and 110 (94, 119) (control); p < 0.001). First pass isolation rate was 84 % (vHP-SD) and 88 % (control, p = 0.888). No differences for severe adverse events (vHP-SD: 1/25, 4 % vs. control: 0/25, 0 %; p = 0.676 were detected.Chronic durability of all PVs was assessed in vHP-SD: 16/25 (64 %) and control: 8/25 (32 %) patients (p = 0.023) and vHP-SD: 81 % and control: 62 % of PVs were found to be isolated (p = 0.003). For right PVs vHP-SD: 84 % vs. control: 60 % of PVs (p < 0.001) and for left PVs vHP-SD: 78 % vs. control: 64 % (p = 0.123) were found to be isolated. Conclusions: PVI solely utilizing vHP-SD via a very close-protocol provides fast, safe and effective acute PVI. High rates of chronically isolated pulmonary veins have been detected.

6.
J Cardiovasc Electrophysiol ; 35(1): 78-85, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37942843

RESUMO

INTRODUCTION: Atrio-esophageal fistula after esophageal thermal injury (ETI) is one of the most devastating complications of available energy sources for atrial fibrillation (AF) ablation. Pulsed field ablation (PFA) uses electroporation as a new energy source for catheter ablation with promising periprocedural safety advantages over existing methods due to its unique myocardial tissue sensitivity. In preclinical animal studies, a dose-dependent esophageal temperature rise has been reported. In the TESO-PFA registry intraluminal esophageal temperature (TESO) changes in a clinical setting are evaluated. METHODS: Consecutive symptomatic AF patients (62 years, 67% male, 61% paroxysmal AF, CHA2 DS2 Vasc Score 2) underwent first-time PFA and were prospectively enrolled into our registry. Eight pulse trains (2 kV/2.5 s, bipolar, biphasic, x4 basket/flower configuration each) were delivered to each pulmonary vein (PV). Two extra pulse trains per PV in flower configuration were added for wide antral circumferential ablation. Continuous intraluminal esophageal temperature (TESO) was monitored with a 12-pole temperature probe. RESULTS: Median TESO change was statistically significant and increased by 0.8 ± 0.6°C, p < .001. A TESO increase ≥ 1°C was observed in 10/43 (23%) patients. The highest TESO measured was 40.3°C. The largest TESO difference (∆TESO) was 3.7°C. All patients remained asymptomatic considering possible ETI. No atrio-esophageal fistula was reported on follow-up. CONCLUSION: A small but significant intraluminal esophageal temperature rise can be observed in most patients during PFA. TESO rise over 40°C is rare. The clinical implications of the observed findings need to be further evaluated.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fístula Esofágica , Veias Pulmonares , Animais , Humanos , Masculino , Feminino , Temperatura , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Frequência Cardíaca , Fístula Esofágica/diagnóstico , Fístula Esofágica/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 35(3): 547-556, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37855621

RESUMO

The QDOT MICRO™ Catheter is a novel open-irrigated contact force-sensing radiofrequency ablation catheter. It offers very high-power short-duration (vHPSD) ablation with 90 W for 4 s to improve safety and efficacy of catheter ablation procedures. Although the QDOT MICRO™ Catheter was mainly designed for pulmonary vein isolation (PVI) its versatility to treat atrial fibrillation (AF) and other types of arrhythmias was recently evaluated by the FAST and FURIOUS study series and other studies and will be presented in this article. Available study and registry data as well as case reports concerning utilization of the QDOT MICRO™ Catheter for the treatment of cardiac arrhythmias including AF, focal and macroreentry atrial tachycardia, typical atrial flutter by cavotricuspid isthmus block, premature ventricular contractions, and accessory pathways were reviewed and summarized. In summary, the QDOT MICRO™ Catheter showed safety and efficacy for PVI and is able to treat also other types of arrhythmias as is was recently evaluated by case reports and the FAST and FURIOUS studies.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Humanos , Resultado do Tratamento , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia
8.
Europace ; 26(1)2023 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-38102318

RESUMO

AIMS: In-hospital complications of catheter ablation for atrial fibrillation (AF), atrial flutter (AFL), and ventricular tachycardia (VT) may be overestimated by analyses of administrative data. METHODS AND RESULTS: We determined the incidences of in-hospital mortality, major bleeding, and stroke around AF, AFL, and VT ablations in four German tertiary centres between 2005 and 2020. All cases were coded by the G-DRG- and OPS-systems. Uniform code search terms were applied defining both the types of ablations for AF, AFL, and VT and the occurrence of major adverse events including femoral vascular complications, iatrogenic tamponade, stroke, and in-hospital death. Importantly, all complications were individually reviewed based on patient-level source records. Overall, 43 031 ablations were analysed (30 361 AF; 9364 AFL; 3306 VT). The number of ablations/year more than doubled from 2005 (n = 1569) to 2020 (n = 3317) with 3 times and 2.5 times more AF and VT ablations in 2020 (n = 2404 and n = 301, respectively) as compared to 2005 (n = 817 and n = 120, respectively), but a rather stable number of AFL ablations (n = 554 vs. n = 612). Major peri-procedural complications occurred in 594 (1.4%) patients. Complication rates were 1.1% (n = 325) for AF, 1.0% (n = 95) for AFL, and 5.3% (n = 175) for VT. With an increase in complex AF/VT procedures, the overall complication rate significantly increased (0.76% in 2005 vs. 1.81% in 2020; P = 0.004); but remained low over time. Following patient-adjudication, all in-hospital cardiac tamponades (0.7%) and strokes (0.2%) were related to ablation. Major femoral vascular complications requiring surgical intervention occurred in 0.4% of all patients. The in-hospital mortality rate adjudicated to be ablation-related was lower than the coded mortality rate: AF: 0.03% vs. 0.04%; AFL: 0.04% vs. 0.14%; VT: 0.42% vs. 1.48%. CONCLUSION: Major adverse events are low and comparable after catheter ablation for AFL and AF (∼1.0%), whereas they are five times higher for VT ablations. In the presence of an increase in complex ablation procedures, a moderate but significant increase in overall complications from 2005-20 was observed. Individual case analysis demonstrated a lower than coded ablation-related in-hospital mortality. This highlights the importance of individual case adjudication when analysing administrative data.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Taquicardia Ventricular , Humanos , Mortalidade Hospitalar , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Flutter Atrial/etiologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/cirurgia , Hospitais , Acidente Vascular Cerebral/epidemiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 34(10): 2029-2039, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37681996

RESUMO

INTRODUCTION: Cryoballoon ablation (CBA) aiming at pulmonary vein isolation (PVI) became a standardized atrial fibrillation (AF) ablation procedure. Life-threatening complications like cardiac tamponade exist. Intracardiac echocardiography (ICE) usage is associated with superior safety in radiofrequency ablation. It is unclear if ICE has an impact on safety of CBA. METHODS: The FREEZE Cohort (NCT01360008) subanalysis included patients undergoing "PVI only" CBA. Patients with intraprocedural transesophageal echocardiography were excluded. Group A comprises conventional, group B ICE-guided CBA. Periprocedural results were compared. RESULTS: From 2011 to 2016, a total of 4189 patients were enrolled, and 1906 (45.5%) were included in this subanalysis, split up in two groups (A: 1066 [55.9%], B: 840 [44.1%]). Group A was younger (60.6 ± 10.8 vs. 62.4 ± 10.5 years, p < .001), with smaller left atria (41 vs. 43 mm, p < .001), and less persistent AF (23.1 vs. 38.1%, p < .001). Procedure, left atrial, and fluoroscopy times were shorter in group A as compared to group B. Dose area product was significantly higher in group A (2911 vs. 2072 cGyxcm2 , p < .001). In-hospital major adverse cerebrovascular and cardiac event rates including two deaths in group A were not different between groups (0.5% vs. 0.1%, p = .18). The rate of total procedural (10.4% vs. 5.1%, p < .001) and major complications (3.2% vs. 1.3%, p < .001) was significantly higher in group A. Cardiac tamponade occurred significantly more frequently in group A (8 [0.8%] vs. 1 [0.1%], p = .046). Independent predictors for major complications were female sex (odds ratio [OR] 2.03, p = .03) and non-ICE usage (OR 2.38, p = .02). No differences were observed for persistent phrenic nerve palsy, nor for groin complications. CONCLUSION: CBA was significantly safer and required less radiation if ICE was used, although the procedures were more complex. The risk of groin complications was not increased with ICE usage. Non-ICE usage was the only modifiable independent predictor of major complications.


Assuntos
Fibrilação Atrial , Tamponamento Cardíaco , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Feminino , Humanos , Masculino , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Tamponamento Cardíaco/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estudos de Coortes , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Ecocardiografia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento , Estudos Prospectivos
10.
Circ J ; 87(12): 1722-1726, 2023 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-37532529

RESUMO

BACKGROUND: Pulsed field ablation (PFA) is a non-thermal energy source with promising safety and efficacy advantages. We aimed to develop a convenient, safe, effective and fast method of pulmonary vein isolation (PVI) utilizing a penta-spline PFA catheter via a single femoral vein and a venous closure system.Methods and Results: Consecutive patients (n=50; mean age: 63.6±10.7 years, 38% female) presenting with AF (paroxysmal AF: 56%) underwent first-time PVI via PFA. A single ultrasound-guided femoral vein puncture and a single transseptal puncture were used. After PVI using the penta-spline PFA catheter, extra pulse trains were added to the posterior wall for wide antral circumferential ablation. A venous closure system was used and a Donati suture was performed. The pressure bandage was removed after 1 h. A total of 196 PVs were identified and isolated with PFA only. The mean procedural time was 27.4±6.6 min, and the mean dwelling time was 14.4±5.5 min. Time to ambulation was 3.3±3.1 h. No severe complications occurred. During a mean follow-up of 6.5±2.1 months, 41/50 patients (82%) remained in sinus rhythm. CONCLUSIONS: The combination of a single venous puncture, single transseptal puncture approach using PFA and vascular closure device resulted in a 100% rate of acute PVI and an extraordinarily fast procedure and time to ambulation. The rate of periprocedural complications was low.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Veias Pulmonares/cirurgia , Resultado do Tratamento , Ablação por Cateter/métodos , Fibrilação Atrial/cirurgia , Catéteres
11.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37589146

RESUMO

AIMS: Catheter ablation with a cryoballoon (CB) provides effective and durable pulmonary vein (PV) isolation (PVI) associated with encouraging clinical outcome data. The novel POLARx CB incorporates unique features, which may translate into improved safety, efficacy, and outcomes. The ICE-AGE-1 study aimed to assess the efficacy, safety, and 1-year clinical follow-up of the POLARx CB in comparison to the Arctic Front Advance Pro CB (AF-CB4). METHODS AND RESULTS: A total of 103 consecutive patients with paroxysmal or persistent atrial fibrillation (AF) who underwent POLARx-based PVI (POLARx group) were prospectively enrolled and were compared to 102 consecutive patients previously treated with the AF-CB4 (AF-CB4 group). The mean age was 68.7 ± 10.2 (POLARx) and 65.7 ± 12 (AF-CB4, P = 0.0551) years. A total of 412 (POLARx) and 404 (AF-CB4) PVs were identified. All PVs, except for one PV in the POLARx group, were successfully isolated. A significant difference regarding the mean minimal CB temperature reached using the POLARx CB (-56.1 ± 8.3°C) and AF-CB4 (-46.9 ± 10.1°C) was observed (P < 0.0001). Real-time PVI was visualized in 71% of PVs in the POLARx group and 46% of them in the AF-CB4 group (P < 0.001). The mean procedure time was comparable: 54.5 ± 17.1 min for POLARx and 59.4 ± 18.6 min for AF-CB4 (P = 0.0509). No differences were observed in terms of periprocedural complications. There were comparable rates in freedom of AF or atrial tachycardia recurrence after 12 months, beyond a 90-day long blanking period: 78.9% in the POLARx group vs. 77.2% in the AF-CB4 group (P = 0.804). CONCLUSION: The novel POLARx CB showed similar safety, efficacy, and 1-year recurrence-free survival rates compared to the AF-CB4. A higher rate of real-time electrical PV recordings and significantly lower balloon temperatures were observed using the POLARx as compared to AF-CB4.


Assuntos
Ablação por Cateter , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Lactente , Veias Pulmonares/cirurgia , Estudos Prospectivos , Ablação por Cateter/efeitos adversos , Temperatura
12.
Front Cardiovasc Med ; 10: 1217745, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37435050

RESUMO

Background: Wide antral circumferential ablation (WACA) in comparison to ostial pulmonary vein (PV) isolation (PVI) has been attributed with improved rhythm outcome. We investigated the feasibility, lesion formation, and rhythm outcome of WACA-PVI in comparison to ostial-PVI using pulsed field ablation (PFA). Methods: Symptomatic atrial fibrillation (AF) patients (69 years, 67% male; 67% paroxysmal AF) were prospectively enrolled into our single-center registry and underwent first-time ostial-PFA or WACA-PFA, N = 15 each. In all patients, eight pulse trains (2 kV/2.5 s, bipolar, biphasic, 4× basket/flower configuration each) were delivered to each PV. In WACA-PFA, two extra pulse trains in a flower configuration were added to the anterior and posterior antrum of the PVs. For comparison of PFA lesion size, pre- and post-ablation left atrial (LA) voltage maps were acquired using a multipolar spiral catheter together with a three-dimensional electroanatomic mapping system. Results: WACA-PFA resulted in a significant larger lesion formation than ostial-PFA (45.5 vs. 35.1 cm2, p = 0.001) with bilateral overlapping butterfly shape-like lesions and concomitant posterior LA wall isolation in 73% of patients. This was not associated with increased procedure time, sedation dosage, or exposure to radiation. One-year freedom from AF recurrence was numerically higher after WACA-PFA than ostial-PFA (94% vs. 87%) but not statistically significant (p = 0.68). No organized atrial tachycardias (ATs) were observed. Ostial-PFA patients more often underwent re-ablation due to recurrent AF episodes. Conclusion: WACA-PFA is feasible and resulted in significantly wider lesion sets than ostial-PFA. Concomitant posterior LA wall isolation occurred as an epiphenomenon in the majority of patients. The WACA approach was associated with neither increased procedure and fluoroscopy times nor statistically significant differences in 1-year rhythm outcome. ATs were absent.

13.
Herz ; 48(3): 212-217, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37277617

RESUMO

Arrhythmic manifestations of COVID-19 include atrial arrhythmias such as atrial fibrillation or atrial flutter, sinus node dysfunction, atrioventricular conduction abnormalities, ventricular tachyarrhythmias, sudden cardiac arrest, and cardiovascular dysautonomias including the so-called long COVID syndrome. Various pathophysiological mechanisms have been implicated, such as direct viral invasion, hypoxemia, local and systemic inflammation, changes in ion channel physiology, immune activation, and autonomic dysregulation. The development of atrial or ventricular arrhythmias in hospitalized COVID-19 patients has been shown to portend a higher risk of in-hospital death. Management of these arrhythmias should be based on published evidence-based guidelines, with special consideration of the acuity of COVID-19 infection, concomitant use of antimicrobial and anti-inflammatory drugs, and the transient nature of some rhythm disorders. In view of new SARS-CoV­2 variants that may evolve, the development and use of newer antiviral and immunomodulator drugs, and the increasing adoption of vaccination, clinicians must remain vigilant for other arrhythmic manifestations that may occur in association with this novel but potentially deadly disease.


Assuntos
Fibrilação Atrial , COVID-19 , Humanos , Incidência , Síndrome de COVID-19 Pós-Aguda , Mortalidade Hospitalar , SARS-CoV-2 , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle
14.
Heart Rhythm ; 20(9): 1238-1245, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37211146

RESUMO

BACKGROUND: Freedom from atrial arrhythmia (AA) recurrence ≥30 seconds after pulsed field ablation (PFA) in patients with atrial fibrillation (AF) was reported in PULSED AF (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF; ClinialTrials.gov Identifier: NCT04198701). AA burden may be a more clinically meaningful endpoint. OBJECTIVE: The purpose of this study was to determine the influence of monitoring strategies on AA detection and AA burden association with quality of life (QoL) and health care utilization (HCU) after PFA. METHODS: Patients underwent 24-hour Holter monitoring at 6 and 12 months and weekly, and symptomatic transtelephonic monitoring (TTM). AA burden post-blanking was calculated as the greater of (1) percentage of AA on total Holter time; or (2) percentage of weeks with ≥1 TTM with AA out of all weeks with ≥1 TTM. RESULTS: Freedom from all AAs varied by >20% when differing monitoring strategies were used. PFA resulted in zero burden in 69.4% of paroxysmal atrial fibrillation (PAF) and 62.2% of persistent atrial fibrillation (PsAF) patients. Median burden was low (<9%). Most PAF and PsAF patients had ≤1 week of AA detection on TTM (82.6% and 75.4%) and <30 minutes of AA per day of Holter monitoring (96.5% and 89.6%), respectively. Only PAF patients with <10% AA burden averaged a clinically meaningful (>19 point) QoL improvement. PsAF patients experienced clinically meaningful QoL improvements irrespective of burden. Repeat ablations and cardioversions significantly increased with higher AA burden (P <.01). CONCLUSION: The ≥30-second AA endpoint is dependent on the monitoring protocol used. PFA resulted in low AA burden for most patients, which was associated with clinically relevant improvement in QoL and reduced AA-related HCU.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Qualidade de Vida , Resultado do Tratamento , Ablação por Cateter/métodos , Aceitação pelo Paciente de Cuidados de Saúde , Recidiva , Veias Pulmonares/cirurgia
15.
Circulation ; 147(19): 1422-1432, 2023 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-36877118

RESUMO

BACKGROUND: Pulsed field ablation uses electrical pulses to cause nonthermal irreversible electroporation and induce cardiac cell death. Pulsed field ablation may have effectiveness comparable to traditional catheter ablation while preventing thermally mediated complications. METHODS: The PULSED AF pivotal study (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF) was a prospective, global, multicenter, nonrandomized, paired single-arm study in which patients with paroxysmal (n=150) or persistent (n=150) symptomatic atrial fibrillation (AF) refractory to class I or III antiarrhythmic drugs were treated with pulsed field ablation. All patients were monitored for 1 year using weekly and symptomatic transtelephonic monitoring; 3-, 6-, and 12-month ECGs; and 6- and 12-month 24-hour Holter monitoring. The primary effectiveness end point was freedom from a composite of acute procedural failure, arrhythmia recurrence, or antiarrhythmic escalation through 12 months, excluding a 3-month blanking period to allow recovery from the procedure. The primary safety end point was freedom from a composite of serious procedure- and device-related adverse events. Kaplan-Meier methods were used to evaluate the primary end points. RESULTS: Pulsed field ablation was shown to be effective at 1 year in 66.2% (95% CI, 57.9 to 73.2) of patients with paroxysmal AF and 55.1% (95% CI, 46.7 to 62.7) of patients with persistent AF. The primary safety end point occurred in 1 patient (0.7%; 95% CI, 0.1 to 4.6) in both the paroxysmal and persistent AF cohorts. CONCLUSIONS: PULSED AF demonstrated a low rate of primary safety adverse events (0.7%) and provided effectiveness consistent with established ablation technologies using a novel irreversible electroporation energy to treat patients with AF. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04198701.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Estudos Prospectivos , Resultado do Tratamento , Antiarrítmicos/uso terapêutico , Eletrocardiografia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
18.
Circ Arrhythm Electrophysiol ; 16(4): e011237, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36891899

RESUMO

BACKGROUND: Radiofrequency catheter ablation (RFCA) is an established treatment for atrial fibrillation (AF) refractory to antiarrhythmic drugs. The economic value of RFCA in delaying disease progression has not been quantified. METHODS: An individual-level, state-transition health economic model estimated the impact of delayed AF progression using RFCA versus antiarrhythmic drug treatment for a hypothetical sample of patients with paroxysmal AF. The model incorporated the lifetime risk of progression from paroxysmal AF to persistent AF, informed by data from the ATTEST (Atrial Fibrillation Progression Trial). The incremental effect of RFCA on disease progression was modeled over a 5-year duration. Annual crossover rates were also included for patients in the antiarrhythmic drug group to mirror clinical practice. Estimates of discounted costs and quality-adjusted life years asssociated with health care utilization, clinical outcomes, and complications were projected over patients' lifetimes. RESULTS: From the payer's perspective, RFCA was superior to antiarrhythmic drug treatment with an estimated mean net monetary benefit per patient of $8516 ($148-$16 681), driven by reduced health care utilization, cost, and improved quality-adjusted life years. RFCA reduced mean (95% CI) per-patient costs by $73 (-$2700 to $2200), increased mean quality-adjusted life years by 0.084 (0.0-0.17) and decreased the mean number of cardiovascular-related health care encounters by 24%. CONCLUSIONS: RFCA is a dominant (less costly and more effective) treatment strategy for patients with AF, especially those with early AF for whom RFCA could delay progression to advanced AF. Increased utilization of RFCA-particularly among patients earlier in their disease progression-may provide clinical and economic benefits.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Antiarrítmicos/uso terapêutico , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Progressão da Doença , Recidiva
19.
Catheter Cardiovasc Interv ; 101(3): 610-619, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36682074

RESUMO

BACKGROUND: Left atrial appendage closure (LAAC) has emerged as an alternative to oral anticoagulation (OAC) for stroke prevention in patients with atrial fibrillation (AF). OAC treatment has been proven feasible in mild-to-moderate chronic kidney disease (CKD). In contrast, the optimal antithrombotic management of AF patients with end-stage renal disease (ESRD) is unknown and LAAC has not been proven in these patients in prospective randomized clinical trials. OBJECTIVES: The objective of this study is to evaluate safety and efficacy of LAAC in patients with ESRD. METHODS: Patients undergoing LAAC were collected in a German multicenter real-world observational registry. A composite endpoint consisting of the occurrence of ischemic stroke/transient ischemic attack, systemic embolism, and/or major clinical bleeding was assessed. Patients with ESRD were compared with propensity score-matched patients without severe CKD. ESRD was defined as a glomerular filtration rate < 15 ml/min/1.73 m2 or chronic hemodialysis treatment. RESULTS: A total of 604 patients were analyzed, including 57 with ESRD and 57 propensity-matched patients. Overall, 596 endocardial and 8 epicardial LAAC procedures were performed. Frequency of major complications was 7.0% (42/604 patients) in the overall cohort, 8.8% (5/57 patients) in patients with ESRD, and 10.5% (6/57 patients) in matched controls (p = 0.75). The estimated event-free survival of the combined endpoint after 500 days was 90.7 ± 4.5% in patients with ESRD and 90.2 ± 5.5% in matched controls (p = 0.33). CONCLUSIONS: LAAC had comparable procedural safety and clinical efficacy in patients with ESRD and patients without severe CKD.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Falência Renal Crônica , Insuficiência Renal Crônica , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento , Apêndice Atrial/diagnóstico por imagem , Estudos Prospectivos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Falência Renal Crônica/complicações , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/terapia , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/terapia , Diálise Renal/efeitos adversos , Sistema de Registros , Anticoagulantes/efeitos adversos
20.
BMC Cardiovasc Disord ; 23(1): 8, 2023 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-36624380

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) is recommended to treat paroxysmal and persistent atrial fibrillation (AF). This analysis aimed to assess the hospital efficiency of single-shot cryoballoon ablation (CBA) and point-by-point radiofrequency ablation (RFA). METHODS: The discrete event simulation used PVI procedure times from the FREEZE Cohort study to establish the electrophysiology (EP) lab occupancy time. 1000 EP lab days were simulated according to an illustrative German hospital, including 3 PVI cases per day using CBA at one site and RFA at the other. RESULTS: The analysis included 1560 CBA patients and 1344 RFA patients from the FREEZE Cohort. Some baseline patients' characteristics were different between groups (age, AF type, and some concomitant diseases), without being statistically associated to ablation procedure time. Mean procedure time was 122.2 ± 39.4 min for CBA and 160.3 ± 53.5 min for RFA (p < 0.0001). RFA was associated with a more than five-fold increase of cumulative overtime compared to CBA over the simulated period (1285 h with RFA and 253 h with CBA). 70.7% of RFA lab days included overtime versus 25.7% for CBA. CBA was associated with more days with an additional hour at the end of the EP lab shift compared to RFA (47.8% vs 11.5% days with one hour left, respectively). CONCLUSION: CBA is faster and more predictable than point-by-point RFA, and enables improvements in EP lab efficiency, including: fewer cumulative overtime hours, more days where overtime is avoided and more days with remaining time for the staff or for any EP lab usage. Clinical trial registration NCT01360008 (first registration 25/05/2011).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Estudos de Coortes , Criocirurgia/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Eletrofisiologia , Resultado do Tratamento , Recidiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...