Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38818790

RESUMO

BACKGROUND: Recent studies have reported that using a stylet does not provide any advantages during intubation within a diverse infant population. Our research focuses on the issue, specifically in premature infants who undergo elective or rescue intubation (EI or RI) in the delivery room (DR). METHODS: We conducted a single-center retrospective observational study comparing the number of intubation attempts, the duration of intubation procedure until successful, and the rate of associated desaturations exceeding 20%. We derived outcomes from video recordings and performed statistical analyses. RESULTS: We have analyzed 104 intubation attempts in 70 infants with a mean gestational age and birth weight of 25±1.9 weeks and 736±221 grams, respectively; 39 of these attempts involved stylet use, and 65 did not. 75% of infants requiring intubation were less than 26 weeks of gestational age. The use of a stylet increased the rate of successful initial attempts [OR (95% CI) 4.3 (1.3-14.8), P=0.019], reduced the duration of the intubation procedure [median (IQR) seconds: 43 (30-72) vs 140 (62-296), P<0.001], and decreased the occurrences of desaturation exceeding 20% (13% vs 50%, P=0.003). CONCLUSION: The benefits of using a stylet during rescue and elective intubations of premature infants in the delivery room outweigh the potential harms. Its use may be advantageous in settings where proactive approaches are implemented for periviable infants.

2.
Biosensors (Basel) ; 14(5)2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38785708

RESUMO

Polluted air and the presence of numerous airborne pathogens affect our daily lives. The sensitive and fast detection of pollutants and pathogens is crucial for environmental monitoring and effective medical diagnostics. Compared to conventional detection methods (PCR, ELISA, metabolic tests, etc.), biosensors bring a very attractive possibility to detect chemicals and organic particles with the mentioned reliability and sensitivity in real time. Moreover, by integrating nanomaterials into the biosensor structure, it is possible to increase the sensitivity and specificity of the device significantly. However, air quality monitoring could be more problematic even with such devices. The greatest challenge with conservative and sensing methods for detecting organic matter such as bacteria is the need to use liquid samples, which slows down the detection procedure and makes it more difficult. In this work, we present the development of a polyacrylonitrile nanofiber bioreceptor functionalized with antibodies against bacterial antigens for the specific interception of bacterial cells directly from the air. We tested the presented novel nanofiber bioreceptor using a unique air filtration system we had previously created. The prepared antibody-functionalized nanofiber membranes for air filtration and pathogen detection (with model organisms E. coli and S. aureus) show a statistically significant increase in bacterial interception compared to unmodified nanofibers. Creating such a bioreceptor could lead to the development of an inexpensive, fast, sensitive, and incredibly selective bionanosensor for detecting bacterial polluted air in commercial premises or medical facilities.


Assuntos
Técnicas Biossensoriais , Escherichia coli , Nanofibras , Staphylococcus aureus , Staphylococcus aureus/isolamento & purificação , Escherichia coli/isolamento & purificação , Monitoramento Ambiental/métodos , Microbiologia do Ar , Resinas Acrílicas
3.
Comput Biol Med ; 169: 107781, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38103481

RESUMO

This article presents an overview of existing approaches to perform vectorcardiographic (VCG) diagnostics of ischemic heart disease (IHD). Individual methodologies are divided into categories to create a comprehensive and clear overview of electrical cardiac activity measurement, signal pre-processing, features extraction and classification procedures. An emphasis is placed on methods describing the electrical heart space (EHS) by several features extraction techniques based on spatiotemporal characteristics or signal modelling and signal transformations. Performance of individual methodologies are compared depending on classification of extent of ischemia, acute forms - myocardial infarction (MI) and myocardial scars localization. Based on a comparison of imaging methods, the advantages of VCG over the standard 12-leads ECG such as providing a 3D orthogonal leads imaging, better performance, and appropriate computer processing are highlighted. The issues of electrical cardiac activity measurements on body surface, the lack of VKG databases supported by a more accurate imaging method, possibility of comparison with the physiology of individual cases are outlined as potential reserves for future research.


Assuntos
Infarto do Miocárdio , Vetorcardiografia , Humanos , Vetorcardiografia/métodos , Coração/fisiologia , Miocárdio , Processamento de Sinais Assistido por Computador , Eletrocardiografia/métodos
4.
Front Pediatr ; 11: 1141432, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37152305

RESUMO

Background: Premature newborns often require oxygen support as part of their therapy. Systems for oxygen administration are developed to assure adequate oxygenation of newborns. Several factors were identified in the systems that contribute to the time delay between the change in the set inspiratory oxygen fraction and its actual delivery to tissues. In this study, we aimed to reduce the physical delay in oxygen delivery to newborns. Methods: We developed an O2 Flush System (O2-FS) that brings the source of oxygen as close to a patient as possible to make oxygen available for rapid delivery that compensates for the physical delay in the ventilator circuit. The O2-FS system is built around an electromechanical on/off valve. We validated the O2-FS concept in experiments with non-invasive Continuous Positive Airways Pressure (CPAP) ventilators. Results: The O2-FS accelerated oxygen delivery with all the tested systems and arrangements, typically by 5-15 s. We also observed that the application of supplemental oxygen increased the pressure in the ventilator circuit by 3-4 cmH2O which may mitigate the apneic pauses that are common in premature newborns. Conclusions: The O2-FS system may work as a universal accessory of the CPAP lung ventilator and shorten the distribution of oxygen to the patient during oxygen desaturation events, possibly eliminating or interrupting apneic pauses in neonates, for whom oxygen therapy is an essential treatment. In clinical practice, the O2-FS could help maintain normoxemic saturation values through adequate oxygen dosing in preterm neonates, thus reducing morbidity and mortality.

5.
Biosens Bioelectron ; 211: 114348, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35605546

RESUMO

the work has been aimed to create an overview of available and used methods and ways to determine the concentration of glucose in body fluids, especially from a technical point of view. It also provides an overview of the clinical features of these methods. The survey found that today's market offers a large number of options and approaches to the issue. There are accurate reference laboratory methods, self-monitoring methods for measuring glucose levels using glucometers, or continuous methods for daily monitoring of blood glucose trends and for insulin pump control. However, it must not be forgotten that the development of full closure of feedback is still not complete today. Individual methods cannot always be compared with each other, precisely because of the focus and the use of these methods. Choosing the right method of blood glucose levels in the body measuring can help patients to manage their diabetes mellitus. The methods listed in the overview are divided in terms of measurement continuity and further according to the invasiveness of the method. Finally, the issues of accuracy in the detection of glycaemia variability and the possibility of further development of these methods are discussed, as it is clear from the survey that the development is focused mainly on continuous methods improving that get to the forefront and also on developing a biosensor that is purely non-invasive and continuous.


Assuntos
Técnicas Biossensoriais , Líquidos Corporais , Diabetes Mellitus Tipo 1 , Glicemia , Automonitorização da Glicemia/métodos , Glucose , Humanos , Hipoglicemiantes , Insulina
6.
Biomed Eng Online ; 21(1): 14, 2022 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-35152895

RESUMO

BACKGROUND: The role of high-frequency oscillatory ventilation (HFOV) has long been debated. Numerous studies documented its benefits, whereas several more recent studies did not prove superiority of HFOV over protective conventional mechanical ventilation (CV). One of the accepted explanations is that CV and HFOV act differently, including gas exchange. METHODS: To investigate a different level of coupling or decoupling between oxygenation and carbon dioxide elimination during CV and HFOV, we conducted a prospective crossover animal study in 11 healthy pigs. In each animal, we found a normocapnic tidal volume (VT) after the lung recruitment maneuver. Then, VT was repeatedly changed over a wide range while keeping constant the levels of PEEP during CV and mean airway pressure during HFOV. Arterial partial pressures of oxygen (PaO2) and carbon dioxide (PaCO2) were recorded. The same procedure was repeated for CV and HFOV in random order. RESULTS: Changes in PaCO2 intentionally induced by adjustment of VT affected oxygenation more significantly during HFOV than during CV. Increasing VT above its normocapnic value during HFOV caused a significant improvement in oxygenation, whereas improvement in oxygenation during CV hyperventilation was limited. Any decrease in VT during HFOV caused a rapid worsening of oxygenation compared to CV. CONCLUSION: A change in PaCO2 induced by the manipulation of tidal volume inevitably brings with it a change in oxygenation, while this effect on oxygenation is significantly greater in HFOV compared to CV.


Assuntos
Ventilação de Alta Frequência , Troca Gasosa Pulmonar , Animais , Pulmão , Estudos Prospectivos , Suínos , Volume de Ventilação Pulmonar
7.
Sensors (Basel) ; 20(15)2020 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-32722397

RESUMO

In this paper, a new approach for the periodical testing and the functionality evaluation of a fetal heart rate monitor device based on ultrasound principle is proposed. The design and realization of the device are presented, together with the description of its features and functioning tests. In the designed device, a relay element, driven by an electric signal that allows switching at two specific frequencies, is used to simulate the fetus and the mother's heartbeat. The simulator was designed to be compliant with the standard requirements for accurate assessment and measurement of medical devices. The accuracy of the simulated signals was evaluated, and it resulted to be stable and reliable. The generated frequencies show an error of about 0.5% with respect to the nominal one while the accuracy of the test equipment was within ±3% of the test signal set frequency. This value complies with the technical standard for the accuracy of fetal heart rate monitor devices. Moreover, the performed tests and measurements show the correct functionality of the developed simulator. The proposed equipment and testing respect the technical requirements for medical devices. The features of the proposed device make it simple and quick in testing a fetal heart rate monitor, thus providing an efficient way to evaluate and test the correlation capabilities of commercial apparatuses.


Assuntos
Feto , Frequência Cardíaca Fetal , Feminino , Frequência Cardíaca , Humanos , Monitorização Fisiológica , Gravidez , Ultrassonografia
8.
Sensors (Basel) ; 20(1)2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-31906383

RESUMO

This paper presents a newly-designed and realized Invasive Blood Pressure (IBP) device for the simulation on patient's monitors. This device shows improvements and presents extended features with respect to a first prototype presented by the authors and similar systems available in the state-of-the-art. A peculiarity of the presented device is that all implemented features can be customized from the developer and from the point of view of the end user. The realized device has been tested, and its performances in terms of accuracy and of the back-loop measurement of the output for the blood pressure regulation utilization have been described. In particular, an accuracy of ±1 mmHg at 25 °C, on a range from -30 to 300 mmHg, was evaluated under different test conditions. The designed device is an ideal tool for testing IBP modules, for zero setting, and for calibrations. The implemented extended features, like the generation of custom waveforms and the Universal Serial Bus (USB) connectivity, allow use of this device in a wide range of applications, from research to equipment maintenance in clinical environments to educational purposes. Moreover, the presented device represents an innovation, both in terms of technology and methodologies: It allows quick and efficient tests to verify the proper functioning of IBP module of patients' monitors. With this innovative device, tests can be performed directly in the field and faster procedures can be implemented by the clinical maintenance personnel. This device is an open source project and all materials, hardware, and software are fully available for interested developers or researchers.


Assuntos
Determinação da Pressão Arterial/instrumentação , Monitores de Pressão Arterial , Pressão Sanguínea/fisiologia , Monitorização Fisiológica/instrumentação , Determinação da Pressão Arterial/métodos , Calibragem , Desenho de Equipamento , Humanos , Monitorização Fisiológica/métodos , Software
9.
Biomed Tech (Berl) ; 63(6): 647-655, 2018 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-28802098

RESUMO

Noninvasive techniques are routinely used for assessment of tissue effects of lung ventilation. However, comprehensive studies of the response time of the methods are scarce. The aim of this study was to compare the response time of noninvasive methods for monitoring of gas exchange to sudden changes in the composition of the inspired gas. A prospective experimental study with 16 healthy volunteers was conducted. A ventilation circuit was designed that enabled a fast change in the composition of the inspiratory gas mixture while allowing spontaneous breathing. The volunteers inhaled a hypoxic mixture, then a hypercapnic mixture, a hyperoxic mixture and finally a 0.3% CO mixture. The parameters with the fastest response to the sudden change of O2 in inhaled gas were peripheral capillary oxygen saturation (SpO2) and regional tissue oxygenation (rSO2). Transcutaneous oxygen partial pressure (tcpO2) had almost the same time of reaction, but its time of relaxation was 2-3 times longer. End-tidal carbon dioxide (EtCO2) response time to change of CO2 concentration in inhaled gas was less than half in comparison with transcutaneous carbon dioxide partial pressure (tcpCO2). All the examined parameters and devices reacted adequately to changes in gas concentration in the inspiratory gas mixture.


Assuntos
Monitorização Transcutânea dos Gases Sanguíneos/métodos , Dióxido de Carbono/química , Respiração Artificial/métodos , Humanos , Oximetria , Tempo de Reação
10.
Exp Lung Res ; 42(2): 87-94, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27070486

RESUMO

UNLABELLED: Purpose/Aim : High-frequency oscillatory ventilation (HFOV) is a method of ventilation that theoretically achieves the goals of lung protective ventilation in acute respiratory distress syndrome (ARDS) patients. It is characterized by a rapid delivery of small tidal volumes at high frequencies oscillating around a continuous distending pressure (CDP). Optimization of CDP is not an easy task and it is titrated empirically in the clinical practice. The aim of this study is to investigate whether the level of CDP consistently affects the shape of the partial pressure of oxygen (PaO2) response to stepwise changes in CDP during HFOV of healthy and ARDS-induced pigs. MATERIALS AND METHODS: We performed two stepwise maneuvers of CDP in 14 pigs: one before and one after the lung lavage, inducing ARDS. For each CDP step performed, we fitted a segment of PaO2 curve with a one-term power model. RESULTS: PaO2 course follows shapes modeled by root, linear, quadratic, and cubic functions for values of PaO2 ≤ 110 mmHg and PaO2 ≤ 200 mmHg, before and after the lung lavage, respectively. PaO2 course follows a shape modeled exclusively by a root function for values of PaO2 > 110 mmHg and PaO2 > 200 mmHg, before and after the lung lavage, respectively. It is not possible to describe a relationship between the shape of the PaO2 course and the values of CDP. CONCLUSIONS: The PaO2 curve may give information about the level of recruitment of alveoli, but cannot be used for optimization of CDP level during HFOV in healthy and ARDS lung model pigs.


Assuntos
Oxigênio/metabolismo , Troca Gasosa Pulmonar/fisiologia , Síndrome do Desconforto Respiratório/fisiopatologia , Animais , Gasometria/métodos , Lavagem Broncoalveolar/métodos , Modelos Animais de Doenças , Feminino , Ventilação de Alta Frequência/métodos , Pressão , Respiração Artificial/métodos , Síndrome do Desconforto Respiratório/metabolismo , Suínos , Volume de Ventilação Pulmonar/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...