1.
Rofo ; 190(3): 265-272, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28950384

RESUMO

PURPOSE: Parallel imaging allows for a considerable shortening of examination times. Limited data is available about the diagnostic accuracy of an accelerated knee MRI protocol based on parallel imaging evaluating all knee joint compartments in a large patient population compared to arthroscopy. MATERIALS AND METHODS: 162 consecutive patients with a knee MRI (1.5 T, Siemens Aera) and arthroscopy were included. The total MRI scan time was less than 9 minutes. Meniscus and cartilage injuries, cruciate ligament lesions, loose joint bodies and medial patellar plicae were evaluated. Sensitivity (SE), specificity (SP), positive predictive value (PPV), and negative predictive value (NPV), as well as diagnostic accuracy were determined. RESULTS: For the medial meniscus, the values were: SE 97 %, SP 88 %, PPV 94 %, and NPV 94 %. For the lateral meniscus the values were: SE 77 %, SP 99 %, PPV 98 %, and NPV 89 %. For cartilage injuries the values were: SE 72 %, SP 80 %, PPV 86 %, and NPV 61 %. For the anterior cruciate ligament the values were: SE 90 %, SP 94 %, PPV 77 %, and NPV 98 %, while all values were 100 % for the posterior cruciate ligament. For loose bodies the values were: SE 48 %, SP 96 %, PPV 62 %, and NPV 93 %, and for the medial patellar plicae the values were: SE 57 %, SP 88 %, PPV 18 %, and NPV 98 %. CONCLUSION: A knee MRI examination with parallel imaging and a scan time of less than 9 minutes delivers reliable results with high diagnostic accuracy. KEY POINTS: · An accelerated knee MRI protocol with parallel imaging allows for high diagnostic accuracy.. · Especially meniscal and cruciate ligament injuries are well depicted.. · Cartilage injuries seem to be overestimated.. CITATION FORMAT: · Schnaiter JW, Roemer F, McKenna-Kuettner A et al. Diagnostic Accuracy of an MRI Protocol of the Knee Accelerated Through Parallel Imaging in Correlation to Arthroscopy. Fortschr Röntgenstr 2018; 190: 265 - 272.


Assuntos
Algoritmos , Artroscopia/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Adolescente , Adulto , Idoso , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/cirurgia , Feminino , Humanos , Corpos Livres Articulares/diagnóstico por imagem , Corpos Livres Articulares/cirurgia , Traumatismos do Joelho/diagnóstico por imagem , Traumatismos do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Patela/diagnóstico por imagem , Patela/cirurgia , Ligamento Cruzado Posterior/diagnóstico por imagem , Ligamento Cruzado Posterior/lesões , Ligamento Cruzado Posterior/cirurgia , Estudos Retrospectivos , Estatística como Assunto , Lesões do Menisco Tibial/diagnóstico por imagem , Lesões do Menisco Tibial/cirurgia , Adulto Jovem
2.
Eur Radiol ; 22(3): 569-78, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21984448

RESUMO

OBJECTIVES: To evaluate radiation dose levels in patients undergoing spiral coronary computed tomography angiography (CTA) on a dual-source system in clinical routine. METHODS: Coronary CTA was performed for 56 patients with electrocardiogram-triggered tube current modulation (TCM) and heart-rate (HR) dependent pitch adaptation. Individual Monte Carlo (MC) simulations were performed for dose assessment. Retrospective simulations with constant tube current (CTC) served as reference. Lung tissue was segmented and used for organ and effective dose (ED) calculation. RESULTS: Estimates for mean relative ED was 7.1 ± 2.1 mSv/100 mAs for TCM and 12.5 ± 5.3 mSv/100 mAs for CTC (P < 0.001). Relative dose reduction at low HR (≤60 bpm) was highest (49 ± 5%) compared to intermediate (60-70 bpm, 33 ± 12%) and high HR (>70 bpm, 29 ± 12%). However lowest ED is achieved at high HR (5.2 ± 1.5 mSv/100 mAs), compared with intermediate (6.7 ± 1.6 mSv/100 mAs) and low (8.3 ± 2.1 mSv/100 mAs) HR when automated pitch adaptation is applied. CONCLUSIONS: Radiation dose savings up to 52% are achievable by TCM at low and regular HR. However lowest ED is attained at high HR by pitch adaptation despite inferior radiation dose reduction by TCM. KEY POINTS: • Monte Carlo simulations allow for individual radiation dose calculations. • ECG-triggered tube current modulation (TCM) can effectively reduce radiation dose. • Slow and regular heart rates allow for highest dose reductions by TCM. • Adaptive pitch accounts for lowest radiation dose at high heart rates. • Women receive higher effective dose than men undergoing spiral coronary CT-angiography.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Método de Monte Carlo , Doses de Radiação , Radiometria/métodos , Tomografia Computadorizada Espiral/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Eletrocardiografia , Feminino , Humanos , Iopamidol/análogos & derivados , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores Sexuais
3.
Eur J Radiol ; 81(4): e461-6, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21640535

RESUMO

PURPOSE: An extensive number of protocols have been suggested to allow for functional diagnostics; however, no data is available about the minimal amount of contrast medium to achieve reliable imaging properties. None of the plethora of existing studies report a rational why the specific concentration was chosen. MATERIALS AND METHODS: A total of 40 patients were included in this prospective, controlled study. They were divided up into four equal groups getting a different concentration (10%, 20%, 30% or 40%) of a second contrast medium bolus. Corresponding septal and right ventricular ROIs were compared. A visual score was established. Coronary attenuation was measured in the right and left coronary artery. Streak artifacts in the right atrium/ventricle were assessed. RESULTS: In the 10% contrast medium (CM) group only in 5/10 (50%) patients full septal delineation was reached. In all other groups full septal visualization was obtained. No group showed a relevant difference of mean density measured in HU units of the left ventricle or the coronary arteries. All study groups except of group 1 (10% CM) showed streak artifacts in the right atrium. CONCLUSION: The dual flow protocol with a minimum concentration of 20% improves septal visualization as basis for left ventricular functional assessment, however, does not allow for reliable right ventricular or atrial visualization. There is no significant difference between the different concentration protocols in terms of coronary attenuation.


Assuntos
Algoritmos , Meios de Contraste/administração & dosagem , Imagem de Perfusão do Miocárdio/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Relação Dose-Resposta a Droga , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Invest Radiol ; 46(2): 116-23, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20856124

RESUMO

OBJECTIVES: computed tomography (CT) is considered the method of choice in thoracic imaging for a variety of indications. Sedation is usually necessary to enable CT and to avoid deterioration of image quality because of patient movement in small children. We evaluated a new, subsecond high-pitch scan mode (HPM), which obviates the need of sedation and to hold the breath. MATERIAL AND METHODS: a total of 60 patients were included in this study. 30 patients (mean age, 14 ± 17 month; range, 0-55 month) were examined with a dual source CT system in an HPM. Scan parameters were as follows: pitch = 3.0, 128 × 0.6 mm slice acquisition, 0.28 seconds gantry rotation time, ref. mAs adapted to the body weight (50-100 mAs) at 80 kV. Images were reconstructed with a slice thickness of 0.75 mm. None of the children was sedated for the CT examination and no breathing instructions were given. Image quality was assessed focusing on motion artifacts and delineation of the vascular structures and lung parenchyma. Thirty patients (mean age, 15 ± 17 month; range, 0-55 month) were examined under sedation on 2 different CT systems (10-slice CT, n = 18; 64-slice CT, n = 13 patients) in conventional pitch mode (CPM). Dose values were calculated from the dose length product provided in the patient protocol/dose reports, Monte Carlo simulations were performed to assess dose distribution for CPM and HPM. RESULTS: all scans were performed without complications. Image quality was superior with HPM, because of a significant reduction in motion artifacts, as compared to CPM with 10- and 64-slice CT. In the control group, artifacts were encountered at the level of the diaphragm (n = 30; 100%), the borders of the heart (n = 30; 100%), and the ribs (n = 20; 67%) and spine (n = 6; 20%), whereas motion artifacts were detected in the HPM-group only in 6 patients in the lung parenchyma next to the diaphragm or the heart (P < 0,001). Dose values were within the same range in the patient examinations (CPM, 1.9 ± 0.6 mSv; HPM, 1.9 ± 0.5 mSv; P = 0.95), although z-overscanning increased with the increase of detector width and pitch-value. CONCLUSION: high-pitch chest CT is a robust method to provide highest image quality making sedation or controlled ventilation for the examination of infants, small or uncooperative children unnecessary, whereas maintaining low radiation dose values.


Assuntos
Pediatria/métodos , Intensificação de Imagem Radiográfica/instrumentação , Radiografia Torácica/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Fatores Etários , Proteção da Criança , Pré-Escolar , Relação Dose-Resposta à Radiação , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Intensificação de Imagem Radiográfica/métodos , Radiografia Torácica/métodos , Estatísticas não Paramétricas , Tomografia Computadorizada por Raios X/métodos
5.
Eur J Radiol ; 80(1): 89-95, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20619991

RESUMO

OBJECTIVE: To evaluate, whether semi-automated vessel extraction and curved planar reformations ("automated vessel extraction") increases diagnostic accuracy in the detection of relevant coronary artery lesions compared to manual, interactive multiplanar interpretation ("manual approach"). MATERIALS AND METHODS: 50 coronary CT angiography datasets were evaluated by four independent readers (two experienced, two novice) for the presence of stenoses exceeding 50% diameter reduction. One experienced and one novice reader each used the "manual approach" for cases 1-25 and "automated vessel extraction" for cases 26-50, while the other two readers used the complementary method. Results were compared to those of invasive coronary angiography. RESULTS: Using the "manual approach", 37 of 42 stenoses were correctly detected by experienced as well as novice readers. 14 vs. 17 lesions were false positive (sensitivity 88%, specificity 91% vs. 89%, PPV 73% vs. 69%, NPV 97%, n.s.). Using "automated vessel extraction", experienced readers detected 35/42 stenoses compared to 31/42 for novice readers. 7 vs. 11 lesions were missed and 17 vs. 15 false-positive lesions reported (sensitivity 83% vs. 74%, specificity 89% vs. 90%, PPV 67%, NPV 95% vs. 93%, n.s.).In patient-based analysis, for novice readers sensitivity was higher using the "manual approach" (97%, 29/30 pts. vs. 80%, 24/30 pts., p=0.069). CONCLUSIONS: Semi-automated vessel extraction and curved multiplanar reconstructions do not improve the diagnostic accuracy of coronary CT angiography compared to the use of interactive multiplanar reformations. Especially for less experienced readers, the use of automatically rendered curved multiplanar reconstructions alone cannot be recommended.


Assuntos
Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Humanos , Valor Preditivo dos Testes , Sensibilidade e Especificidade
6.
J Cardiovasc Comput Tomogr ; 4(2): 110-5, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20430341

RESUMO

BACKGROUND: The computed tomographic (CT) attenuation of coronary atherosclerotic plaque has been proposed as a marker for tissue characterization and may thus potentially contribute to the assessment of plaque instability. OBJECTIVE: We analyzed the influence of reconstruction parameters on CT attenuation measured within noncalcified coronary atherosclerotic lesions. METHODS: Seventy-two patients were studied by contrast-enhanced dual-source CT coronary angiography (330 millisecond rotation time, 2 x 64 x 0.6 mm collimation, 120 kV, 400 mAs, 80 mL contrast agent intravenously at 6 mL/s), and a total of 100 distinct noncalcified coronary atherosclerotic plaques were identified. Image data sets were reconstructed with a soft (B20f), medium soft (B26f), and sharp (B46f) reconstruction kernel. With the medium soft kernel, image data sets were reconstructed with a slice thickness/increment of 0.6/0.3 mm, 0.75/0.4 mm, and 1.0/0.5mm. Within each plaque, CT attenuation was measured. RESULTS: Mean CT attenuation using the medium soft kernel was 109 +/- 58 HU (range, -16 to 168 HU). Using the soft kernel, mean density was 113 +/- 57 HU (range, -13 to 169 HU), and using a sharp kernel, mean density was 97 +/- 49 HU (range, -23 to 131 HU). Similarly, reconstructed slice thickness had a significant influence on the measured CT attenuation (mean values for medium soft kernel: 102 +/- 52 HU versus 109 +/- 58 HU versus 113 +/- 57 HU for 0.6-mm, 0.75-mm, and 1.0-mm slice thickness). The differences between 0.75-mm and 0.6-mm slice thickness (P = 0.05) and between medium sharp and sharp kernels (P = 0.02) were statistically significant. CONCLUSIONS: Image reconstruction significantly influences CT attenuation of noncalcified coronary atherosclerotic plaque. With decreasing spatial resolution (softer kernel or thicker slices), CT attenuation increases significantly. Using absolute CT attenuation values for plaque characterization may therefore be problematic.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Calcinose , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
8.
Eur Radiol ; 20(5): 1197-206, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-19890639

RESUMO

OBJECTIVE: To evaluate staged low-dose approaches for coronary CT angiography (CTA) in which a standard sequence was added if the low-dose sequence did not allow reliable rule-out of coronary stenosis. PATIENTS AND METHODS: A total of 176 consecutive patients referred for dual-source CTA were randomized to three protocols: group 1 using prospective ECG-triggering (100 kV, 330 mAs), group 2 a retrospectively gated "MinDose" sequence (100 kV, 330 mAs) and group 3 a standard spiral sequence (120 kV, 400 mAs). If image quality in low-dose groups 1 or 2 was non-diagnostic, an additional standard CT examination (as in group 3) was performed. RESULTS: Non-diagnostic image quality was found in 11/56, 4/55, and 2/65 patients (46/896, 4/880 and 3/1,040 coronary segments) in groups 1, 2 and 3, respectively. Median (interquartile ranges) volumes of contrast material, CTDI(vol), DLP and effective dose for low-dose groups 1 and 2 and for standard group 3 were 92.5 (11.3), 75.0 (2.5) and 75.0 (9.0) ml; 8.0 (1.4), 16.8 (4.8) and 48.1 (14.2) mGy; 108.0 (27.3), 246.0 (93.0) and 701.0 (207.8) mGy cm; and 1.5 (0.4), 3.4 (1.3) and 9.8 (2.9) mSv, respectively. CONCLUSION: A staged coronary CTA protocol with an initial low-dose approach and addition of a standard sequence--should image quality be too low--can lead to a substantial reduction in radiation exposure.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Doença das Coronárias/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Idoso , Meios de Contraste , Feminino , Humanos , Imageamento Tridimensional , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estatísticas não Paramétricas
9.
Eur Radiol ; 19(11): 2576-83, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19760421

RESUMO

OBJECTIVE: We evaluated radiation exposure and image quality of a new coronary CT angiography protocol, high-pitch spiral acquisition, using dual source CT (DSCT). MATERIAL AND METHODS: Coronary CTAwas performed in 25 consecutive patients with a stable heart rate of 60 bpm or less after premedication, using 2 x 128 0.6-mm sections, 38.4-mm collimation width and 0.28-s rotation time. Tube settings were 100 kV/320 mAs and 120 kV/400 mAs for patients below and above 100-kg weight, respectively. Data acquisition was prospectively ECG-triggered at 60% of the R-R interval using a pitch of 3.2 (3.4 for the last 10 patients). Images were reconstructed with 75-ms temporal resolution, 0.6-mm slice thickness and 0.3-mm increment. Image quality was evaluated using a four-point scale (1 = excellent, 4 = unevaluable). RESULTS: Mean range of data acquisition was 113 +/- 22 mm, mean duration was 268 +/- 23 ms. Of 363 coronary artery segments, 327 had an image quality score of 1, and only 2 segments were rated as "unevaluable". Mean dose-length product (DLP) was 71 +/- 23 mGy cm, mean effective dose was 1.0 +/- 0.3 mSv (range 0.78-2.1 mSv). For 21 patients with a body weight below 100 kg, mean DLP was 63 +/- 5 mGy cm (0.88 +/- 0.07 mSv; range 0.78-0.97 mSv). CONCLUSION: Prospectively ECGtriggered high-pitch spiral CT acquisition provides high and stable image quality at very low radiation dose.


Assuntos
Angiografia Coronária/métodos , Eletrocardiografia/métodos , Tomografia Computadorizada por Raios X/métodos , Peso Corporal , Feminino , Coração/diagnóstico por imagem , Frequência Cardíaca , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Modelos Anatômicos , Estudos Prospectivos , Doses de Radiação , Tomografia Computadorizada Espiral/métodos
10.
J Cardiovasc Comput Tomogr ; 3(2): 117-21, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19332343

RESUMO

Coronary CT angiography allows high-quality imaging of the coronary arteries when state-of-the-art CT systems are used. However, radiation exposure has been a concern. We describe a new scan mode that uses a very high-pitch spiral acquisition, "Flash Spiral," which has been developed specifically for low-dose imaging with dual-source CT. The scan mode uses a pitch of 3.2 to acquire a spiral CT data set, while covering the entire volume of the heart in one cardiac cycle. Data acquisition is prospectively triggered by the electrocardiogram and starts in late systole to be completed within one cardiac cycle. Images are reconstructed with a temporal resolution that corresponds to one-quarter of the gantry rotation time. Throughout the data set, subsequent images are reconstructed at later time instants in the cardiac cycle. In a patient with a heart rate of 49 beats/min, the Flash Spiral scan mode was used with a first-generation dual-source CT system and allowed artifact-free visualization of the coronary arteries with a radiation exposure of 1.7 mSv for a 12-cm scan range at 120 kVp tube voltage.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada Espiral , Angiografia Coronária/efeitos adversos , Eletrocardiografia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Doses de Radiação , Lesões por Radiação/etiologia , Lesões por Radiação/prevenção & controle , Interpretação de Imagem Radiográfica Assistida por Computador
11.
Am J Cardiol ; 103(6): 812-7, 2009 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-19268737

RESUMO

Assessment of coronary artery stents using computed tomographic angiography has been challenging. The technology of dual-source computed tomography (DSCT) provides higher temporal resolution that may allow more accurate evaluation of coronary stents. This study evaluated the accuracy of DSCT for the assessment of coronary artery in-stent restenosis. A total of 112 patients with 150 previously implanted coronary stents (diameter > or = 3.0 mm) were examined using DSCT (Definition; Siemens Medical Solutions, Forchheim, Germany) before conventional coronary angiography. Each stent was classified as assessable or not assessable. All assessable stents were further classified for the absence or presence of in-stent restenosis (>50% diameter reduction) using DSCT, and results were compared with those using quantitative coronary angiography. Mean stent diameter was 3.27 +/- 0.35 mm. Fifteen of 80 stents (19%) with a diameter of 3.0 mm were not assessable, and all 70 stents >3.0 mm were assessable. DSCT correctly identified 16 of 19 in-stent restenoses in 135 assessable stents, as well as the absence of in-stent restenosis in 110 of 116 stents (sensitivity 84%, specificity 95%, positive predictive value 73%, and negative predictive value 97% in assessable stents). In conclusion, DSCT may be useful to noninvasively detect in-stent restenosis, especially in stents with a relatively large diameter.


Assuntos
Reestenose Coronária/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sensibilidade e Especificidade
13.
Eur J Radiol ; 68(3): 392-7, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19008063

RESUMO

PURPOSE: Evaluation of a new protocol for Dual-source CT contrast-enhanced cardiac imaging for better visualization of right ventricle structures. METHODS: A total of 106 patients were included in this prospective, controlled study. The control group (n=53) underwent our clinic's standard procedure for contrast-enhanced imaging of coronary arteries. The study group (n=53) was imaged using a protocol with the dual flow injection protocol in which the saline chaser bolus contained 20% contrast media. The images were analyzed for mean density values using defined ROIs in the septum and both ventricles. In addition the data sets were semi-quantitatively evaluated for visual delineation between right ventricle and septum. To investigate whether this new protocol influenced the visualization of coronary arteries, mean density was also measured in the right and left coronary artery. RESULTS: The dual flow concept allows for a statistically significant better delineation of the septum in Dual-source cardiac computed tomography for both the quantitative and semi-quantitative analyses. Also, the dual flow concept allows for statistically relevant higher coronary attenuation. CONCLUSION: Using a saline chaser containing 20% contrast medium improves septal delineation for functional ventricular analysis as well as unimpaired coronary visualization.


Assuntos
Meios de Contraste/administração & dosagem , Ventrículos do Coração/diagnóstico por imagem , Iopamidol/análogos & derivados , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Disfunção Ventricular Direita/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Iopamidol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Congenit Heart Dis ; 3(4): 288-90, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18715464

RESUMO

Complex pulmonary vascular blood supply is common in patients with tetralogy of Fallot with pulmonary atresia, major systemic to pulmonary collateral arteries and hypoplastic or deficient central pulmonary arteries. An extralobar lung sequestration, which has not been described previously in these patients, was imaged in a 6-week-old infant with multidetector computed tomography with sub-millimeter resolution. Arterial and venous vessels were analyzed using three-dimensional vascular exploration tools and results were confirmed with cardiac catheterization.


Assuntos
Anormalidades Múltiplas/diagnóstico por imagem , Sequestro Broncopulmonar/diagnóstico por imagem , Sequestro Broncopulmonar/epidemiologia , Comunicação Interventricular/epidemiologia , Atresia Pulmonar/diagnóstico por imagem , Atresia Pulmonar/epidemiologia , Tetralogia de Fallot/epidemiologia , Tomografia Computadorizada por Raios X/métodos , Anormalidades Múltiplas/fisiopatologia , Sequestro Broncopulmonar/patologia , Circulação Colateral , Comorbidade , Humanos , Lactente , Masculino , Artéria Pulmonar/diagnóstico por imagem , Tetralogia de Fallot/fisiopatologia
15.
JACC Cardiovasc Imaging ; 1(2): 177-86, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19356426

RESUMO

OBJECTIVES: The purpose of this study was to analyze the influence of a systematic approach to lower heart rate for coronary computed tomography (CT) angiography on diagnostic accuracy of 64-slice single- and dual-source CT. BACKGROUND: Coronary CT angiography is often impaired by motion artifacts, so that routine lowering of heart rate is usually recommended. This is often conceived as a major limitation of the technique. It is expected that higher temporal resolution, such as with dual-source 64-slice CT, would allow diagnostic imaging even without systematic pre-treatment for lowering the heart rate. METHODS: Two hundred patients with suspected coronary artery disease were first randomized to either 64-slice single-source CT (n = 100) or dual-source CT (n = 100) for contrast-enhanced coronary artery evaluation. In each group, patients were further randomized to either receive systematic heart rate control (oral and intravenous beta-blockade for a target heart rate < or =60 beats/min) or receive no premedication. Evaluability of datasets and diagnostic accuracy were compared between groups against the results obtained from invasive angiography. RESULTS: Systematic pre-treatment lowered heart rate during CT coronary angiography by 10 beats/min. Heart rate control significantly improved evaluability in single-source CT (93% vs. 69% on a per-patient basis, p = 0.005), whereas it did not in dual-source CT (96% vs. 98%). In evaluable patients, sensitivity to detect the presence of at least 1 coronary stenosis by single-source CT was 86% and 79%, respectively, with and without heart rate control (p = NS). For dual-source CT, it was 100% and 95%, respectively (p = NS). The rate of correctly classified patients, defined as evaluable and correct classification as to the presence or absence of at least 1 coronary artery stenosis, was significantly improved by heart rate control in single-source CT (78% vs. 57%, p = 0.04), whereas there was no such influence in dual-source CT (87% vs. 93%). CONCLUSIONS: Systematic heart rate control significantly improves image quality for coronary visualization by 64-slice single-source CT, whereas image quality and diagnostic accuracy remain unaffected in dual-source CT angiography. Improved temporal resolution obviates the need for heart rate control.


Assuntos
Antagonistas Adrenérgicos beta/administração & dosagem , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Frequência Cardíaca/efeitos dos fármacos , Tomografia Computadorizada por Raios X , Administração Oral , Idoso , Angiografia Coronária/instrumentação , Estenose Coronária/fisiopatologia , Desenho de Equipamento , Feminino , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Intensificação de Imagem Radiográfica , Interpretação de Imagem Radiográfica Assistida por Computador , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X/instrumentação
16.
Eur J Radiol ; 66(1): 127-33, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17851011

RESUMO

AIMS: Detecting stenoses of coronary arteries with multidetector row computer tomography (MDCT) is a well feasible non-invasive method. However, there is still the problem of deciding whether a stenosis is hemodynamically relevant or not. Objective of the present study was to validate the feasibility of a low dose protocol for MDCT using 80 kV for detecting late enhancement. METHODS AND RESULTS: Using a Alderson-Rando Phantom evaluation of the effective dose of this LE protocol was performed. Ten patients (six male, four female, mean age 61) with known coronary artery disease and scheduled for a conventional coronary angiogram in our facility were subsequently recruited. All patients underwent CT-angiography (CTA) 1 day prior to magnetic resonance imaging. Five minutes after the application of 100ml contrast agent for the CTA scan, a low dose late enhancement scan (80 kV, 400 mA s maximum, ECG pulsed scan, 64 mm x 0.6mm collimation, 0.33 s tube rotation) was performed. Phantom dose measurements showed an effective dose for this protocol of 1.19 mSv (male) and 1.61 mSv (female). Fifty-six percent (5/9) of the patients showed a late enhancement on the MRI scan. Three transmural late enhancements and all four negative findings were correctly identified by CT. This represents a sensitivity of 78% (3/5), specificity of 100% (3/3), NPV of 100% (4/4) and a PPV of 97%. CONCLUSION: We were able to show that the low dose protocol is feasible and, furthermore, preliminary results look promising.


Assuntos
Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Meios de Contraste , Angiografia Coronária , Estudos de Viabilidade , Feminino , Gadolínio DTPA , Humanos , Iopamidol/análogos & derivados , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Valor Preditivo dos Testes , Sensibilidade e Especificidade
17.
J Am Coll Cardiol ; 50(25): 2393-8, 2007 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-18154964

RESUMO

OBJECTIVES: We evaluated the influence of heart rate on image quality and diagnostic accuracy of dual-source computed tomography (DSCT) coronary angiography. BACKGROUND: Multidetector computed tomography (MDCT) coronary angiography has demonstrated an inverse relationship between heart rate and image quality. Dual-source CT provides a higher temporal resolution. METHODS: One hundred patients were studied by DSCT (DEFINITION, Siemens Medical Solutions, Forchheim, Germany). A contrast-enhanced volume dataset was acquired (two tubes, 120 kV, 400 mAs/rot, collimation 64 x 0.6 mm). Datasets were evaluated concerning the presence of significant coronary stenoses and validated against invasive coronary angiography. RESULTS: In 44 patients with a heart rate > or =65 beats/min, 566 of 616 coronary segments were evaluable (92%), whereas in 56 patients with a heart rate <65 beats/min, 777 of 778 coronary segments were evaluable (100%, p < 0.001). On a per-patient basis, 93% of patients (> or =65 beats/min) and 100% of patients (<65 beats/min) were considered evaluable. By classifying unevaluable segments as positive for stenosis, per-patient sensitivity was 95% (19 of 20) for heart rates > or =65 beats/min and 100% (22 of 22) for heart rates <65 beats/min. Specificity was 87% (21 of 24) versus 76% (26 of 34), and overall diagnostic accuracy was 91% (40 of 44) versus 86% (48 of 56). None of these differences were statistically significant. Similarly, no difference in diagnostic accuracy was found in per-vessel and -segment analyses. CONCLUSIONS: In 100 patients studied without beta-blocker pre-medication, DSCT demonstrated slightly lower per-segment evaluability for high heart rates but no decrease in diagnostic accuracy for the detection of coronary artery stenoses.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Frequência Cardíaca/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Meios de Contraste/administração & dosagem , Eletrocardiografia/métodos , Feminino , Humanos , Iohexol , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
18.
J Comput Assist Tomogr ; 31(3): 444-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17538294

RESUMO

A waxed piglet heart was scanned with a flat panel volume computed tomography scanner (voxel size, 0.25 mm). Virtual and real laser-sintered models showed excellent visual concordance with the original. Using an iterative-closest-point algorithm, a very low mean surface distance was found between the original and laser-sintered model (0.26 +/- 0.34 mm). These techniques allow submillimeter 3-dimensional virtual and real reconstructions without destroying the original and might be useful for teaching, research, and planning of cardiac interventions.


Assuntos
Coração/diagnóstico por imagem , Imageamento Tridimensional , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Animais , Coração/anatomia & histologia , Técnicas In Vitro , Suínos
19.
J Diabetes Complications ; 21(2): 69-74, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17331854

RESUMO

BACKGROUND: Diabetes mellitus is an important risk factor for coronary artery disease. Cardiac multislice computed tomography (MSCT) permits visualization of the coronary arteries with good sensitivity and specificity. However, at present, there are no data whether MSCT allows an accurate assessment of coronary arteries of diabetic patients, in comparison to nondiabetic patients. Thus, we compared the catheter-controlled MSCT results from diabetic and nondiabetic patients in a cohort of 116 patients with regard to sensitivity, specificity, positive predictive value, and negative predictive value, as well as image quality. METHODS AND MATERIALS: Twenty-two diabetic patients (age, 64.6+/-8.5 years; number of risk factors, 3.4+/-1.1) and 94 nondiabetic patients (age, 64.2+/-9.2 years; number of risk factors, 2.4+/-1.0) were examined by MSCT (Sensation 16 Speed 4 D, Siemens, Forchheim, Germany; gantry rotation time, 375 ms) and invasive coronary angiography. MSCT results were compared, blinded to the results of the coronary angiography with regard to the presence or absence of a significant stenosis (>50%) in a modified American Heart Association 13-segment model. Image quality was assessed on a qualitative scale between 1 (very good) and 5 (invisible) for each segment. RESULTS: Sensitivity, specificity, positive predictive value, and negative predictive value were statistically not different in diabetic and nondiabetic patients (0.85/0.98/0.92/0.96 vs. 0.84/0.97/0.91/0.95). One diabetic and three nondiabetic patients had to be excluded from analysis. Diabetic patients had relevantly more risk factors (P < .05), but calcium scoring was not different in both groups (Agatston score 1090+/-1278 vs. 798+/-1033). The image quality in both cohorts was comparable. CONCLUSIONS: MSCT allows the assessment of the coronary arteries noninvasively in diabetic patients with a good sensitivity and specificity, and diabetes does not have an impact on the number of evaluable segments. Thus, MSCT is a noninvasive tool in the care of these patients.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Angiopatias Diabéticas/diagnóstico , Tomografia Computadorizada Espiral/métodos , Idoso , Calcinose/diagnóstico , Estudos de Coortes , Estenose Coronária/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Tomografia Computadorizada Espiral/instrumentação
20.
Invest Radiol ; 42(3): 189-95, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17287649

RESUMO

PURPOSE: Multislice detector computed tomography (MSCT) is an accurate noninvasive modality to detect and classify different stages of atherosclerosis. The aim of the New Age II Study was to detect coronary lesions in men without established coronary artery disease (CAD) but with a distinct cardiovascular risk profile. We also sought to assess the effect after 1 year of a lipid-lowering therapy (LLT) using 20 mg of atorvastatin. METHODS: Forty-sixe male patients (mean, 61 +/- 10 years) with an elevated risk for CAD (PROCAM score >3 quintile) without LLT were included. Native and contrast-enhanced scans were performed in all patients. A total of 27 of 46 patients received a follow-up scan (after 488 +/- 138 days). Coronary plaque burden (CPB) was assessed volumetrically. RESULTS: The prevalence of CAD was 83% (38/46 patients), and 11% (5/46) without coronary calcifications still had noncalcified plaques. Total cholesterol and low-density lipoprotein cholesterol levels decreased significantly under LLT (225 +/- 41 mg/dL vs. 162 +/- 37 mg/dL, P < 0.0001 and 148 +/- 7 mg/dL vs. 88 +/- 5 mg/dL, P < 0.001, respectively). On follow-up, calcium score and CPB remained unchanged (Agatston score: 261 +/- 301 vs. 282 +/- 360; CPB: 0.149 +/- 0.108 vs. 0.128 +/- 0.075 mL, P > 0.05), whereas mean plaque volume of noncalcified plaques decreased significantly from 0.042 +/- 0.029 mL versus 0.030 +/- 0.014 mL (P < 0.05, mean reduction 0.012 +/- 0.017 mL or 24 +/- 13%). CONCLUSIONS: Statin therapy led to a significant reduction of noncalcified plaque burden that was not reflected in calcium scoring or total plaque burden. This finding might explain the risk reduction after the initiation of statin therapy. Using multislice detector computed tomography, physicians have the potential to monitor medical treatment in patients with coronary atherosclerosis.


Assuntos
Calcinose/tratamento farmacológico , Doença da Artéria Coronariana/tratamento farmacológico , Vasos Coronários/patologia , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Hipolipemiantes/uso terapêutico , Adulto , Idoso , Doença da Artéria Coronariana/patologia , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/farmacologia , Hipolipemiantes/farmacologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Tomografia Computadorizada por Raios X