Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cardiothorac Vasc Anesth ; 22(3): 388-93, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18503926

RESUMO

OBJECTIVE: The Vigileo/FloTrac system (software version 1.01; Edwards Lifesciences, Irvine, CA) determines cardiac output, without calibration, by analysis of the arterial pulse wave. To assess the accuracy of the Vigileo/FloTrac system, it was compared with the pulmonary artery catheter bolus thermodilution method as the current standard method. The study design was prospective and observer blinded. SETTING: A single university hospital. PARTICIPANTS: Thirty elective coronary artery bypass graft surgery patients. No special interventions were done to the participants. MEASUREMENTS AND MAIN RESULTS: After approval by the ethics committee and with written informed consent, synchronized measurements using both methods were made at 7 predefined time points, intraoperatively and postoperatively, producing 192 data pairs for evaluation. The statistical evaluation was performed by using the Bland-Altman method of analysis. In addition, a +/-20% and +/-30% deviation from the pulmonary artery catheter were evaluated (20% criteria and 30% criteria). In total, 46% of measurements did not fulfill the 20% criteria; 26% were outside the 30% limits. The Bland-Altman analysis for all time points showed that 95% of all differences between both methods were within a range between -2.2 and +3.1 L/min. Regression analysis revealed low correlation values at all time points. CONCLUSION: The described deviation from the standard must be regarded according to the user's needs. Considering the 30% limits of agreement, the Vigileo system (version 1.01) seems sufficiently accurate; applying the 20% criteria, it is not.


Assuntos
Débito Cardíaco/fisiologia , Monitorização Fisiológica/métodos , Monitorização Fisiológica/normas , Idoso , Idoso de 80 Anos ou mais , Ponte de Artéria Coronária/instrumentação , Ponte de Artéria Coronária/métodos , Ponte de Artéria Coronária/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/instrumentação , Monitorização Intraoperatória/métodos , Monitorização Intraoperatória/normas , Monitorização Fisiológica/instrumentação , Estudos Prospectivos , Sensibilidade e Especificidade , Método Simples-Cego , Termodiluição/instrumentação , Termodiluição/métodos , Termodiluição/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA