Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 30(3): 4261-4273, 2022 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-35209666

RESUMO

In this paper, we present a novel study on the impact of lossy data compression on the metrological properties of holographic tomography reconstruction of the refractive index (RI). We use a spatial bandwidth-optimized compression procedure that leverages the properties of image plane off-axis holograms and standardized compression codecs, both widely applied in research and industry. The compression procedure is tested at multiple bitrates, for four different objects and against three reconstruction algorithms. The metrological evaluation is primarily done by comparison to the reconstruction from original data using the root-mean-squared error (RMSE). We show that due to differences between objects and different noise sensitivities of the reconstruction algorithms, the rate-distortion behaviour varies, but in most cases allows for the compression below 1 bit per pixel, while maintaining an RI RMSE less than 10-4.

2.
Opt Express ; 28(19): 27873-27892, 2020 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-32988071

RESUMO

Image plane off-axis holograms (IP-OAH) are the most common data captured in digital holographic microscopy and tomography. Due to increasing storage and data transmission requirements, lossy compression of such holograms has been subject of earlier investigations. However, hologram compression can not be allowed to hinder the metrological capabilities of the measurement technique itself. In this work, we present lossy and lossless IP-OAH compression approaches that are based on conventional compression codecs, but optimized with regard to bandwidth of the signal. Both approaches outperform respective conventional codecs, while the lossy approach is shown to uphold the accuracy of holographic phase measurements.

4.
Appl Opt ; 30(13): 1633-5, 1991 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-20700335

RESUMO

A use of the multichannel phase stepped interferometry approach to automated fringe pattern analysis in moire interferometry is described. Polarization optics is used to implement the appropriate phase shifts in each channel. The channels are created by inserting a diffraction grating at the output of the interferometer. It is possible to work at one frame rate. This system enables studies in unstable environmental conditions and studies of time dependent events.

5.
Appl Opt ; 28(5): 828-9, 1989 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-20548569

RESUMO

This Letter reports some errors associated with misalignment in real-time holographic interferometers using the spatial phase stepping method.

6.
Appl Opt ; 27(2): 312-20, 1988 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-20523592

RESUMO

A modified holographic interferometer is described which enables automatic fringe pattern analysis to be achieved when recording transient events. The introduction of a phase grating enables the method of phasestepping fringe analysis to be applied to a wide range of measurement problems. The theory is developed, and an analysis of the sources of error is presented with the aid of computer simulations. Initial experimental results confirm the utility of the method and its potential application in pulsed laser holography. The method can in principle be applied to electronic speckle pattern interferometry.

7.
Appl Opt ; 26(22): 4712-4, 1987 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-20523432
8.
9.
Appl Opt ; 24(18): 3041, 1985 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-18224000
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...