Environ Sci Pollut Res Int ; 22(24): 20295-305, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26304813

RESUMO

Analysis of diurnal patterns of surface ozone (O3) at multiple urban sites in the UK shows the occurrence of prominent nocturnal enhancements during the winter months (November-March). Whilst nocturnal surface ozone (NSO) enhancement events have been observed at other locations, this is the first time that such features have been demonstrated to occur in the UK and the second location globally. The observed NSO enhancement events in the UK were found to be so prevalent that they are clearly discernible in monthly diurnal cycles averaged over several years of data. Long-term (2000-2010) analysis of hourly surface ozone data from 18 urban background stations shows a bimodal diurnal variation during the winter months with a secondary nighttime peak around 0300 hours along with the primary daytime peak. For all but one site, the daily maxima NSO concentrations during the winter months exceeded 60 µg/m(3) on >20 % of the nights. The highest NSO value recorded was 118 µg/m(3). During the months of November, December, and January, the monthly averaged O3 concentrations observed at night (0300 h) even exceeded those observed in the daytime (1300 h). The analysis also shows that these NSO enhancements can last for several hours and were regional in scale, extending across several stations simultaneously. Interestingly, the urban sites in the north of the UK exhibited higher NSO than the sites in the south of the UK, despite their daily maxima being similar. In part, this seems to be related to the sites in the north typically having lower concentrations of nitrogen oxides.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/métodos , Óxidos de Nitrogênio/análise , Ozônio/análise , Urbanização , Estações do Ano , Reino Unido
2.
Environ Sci Pollut Res Int ; 18(8): 1442-55, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21494819

RESUMO

BACKGROUND, AIM, AND SCOPE: The present study is an attempt to examine some of the probable causes of the unusually low tropospheric column ozone observed over eastern India during the exceptional drought event in July 2002. METHOD: We examined horizontal wind and omega (vertical velocity) anomalies over the Indian region to understand the large-scale dynamical processes which prevailed in July 2002. We also examined anomalies in tropospheric carbon monoxide (CO), an important ozone precursor, and observed low CO mixing ratio in the free troposphere in 2002 over eastern India. RESULTS AND DISCUSSION: It was found that instead of a normal large-scale ascent, the air was descending in the middle and lower troposphere over a vast part of India. This configuration was apparently responsible for the less convective upwelling of precursors and likely caused less photochemical ozone formation in the free troposphere over eastern India in July 2002. CONCLUSION: The insight gained from this case study will hopefully provide a better understanding of the process controlling the distribution of the tropospheric ozone over the Indian region.


Assuntos
Movimentos do Ar , Poluentes Atmosféricos/análise , Atmosfera/química , Secas , Monitoramento Ambiental , Ozônio/análise , Geografia , Índia
3.
Rev Sci Instrum ; 80(5): 053111, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19485496

RESUMO

The conventional dual polarization micropulse lidar uses two separate photomultiplier tubes (PMT) to detect both the copolarized and cross-polarized beam. The prominent sources of error in the depolarization ratio measurement are mismatch in PMT, improper selection of discriminator threshold and unequal PMT high voltage. In the present work a technique for the measurement of lidar depolarization ratio using only one PMT sensor has been developed. The same PMT detects both copolarized and cross-polarized lidar backscatter. A stepper motor is used along with the mirrors to bring both the received polarization signals over the PMT window. Application of the same PMT minimizes the error caused in the depolarization ratio measurement due to error in photon counting of an individual channel. The design description of this technique along with the preliminary results depicting its functionality has been mentioned in this article.