Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Int Dent J ; 72(5): 691-697, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35810011

RESUMO

OBJECTIVE: Since the outbreak of SARS-CoV-2, aerosol control in the operatory has become a key safety issue in dentistry. The utilisation of extraoral scavenger devices (EOSs) is one of the various approaches to in-treatment aerosol reduction in dentistry. The use and efficacy of EOSs in dental settings, however, are still a matter of debate in the literature and there are still open questions about their proper use. Thus, research into this area is essential to inform dental practice. The objective of this study was to examine the aerosol reduction efficacy of two different EOS in vitro. METHODS: Two commercially available EOSs were tested during modeled dental treatment in a setup that previously proved to generate high aerosol load. Measurements were done in two particle size ranges: 5.6-560 nm (the full range of the spectrometer) and 60.4-392.4 nm (a range that is especially relevant to the spread of SARS-CoV-2 with aerosol). RESULTS: Both devices managed to reduce the aerosol load to a statistically significant extent as compared to the scenario when only a high-volume evacuator and a saliva ejector (and no EOS) were used. CONCLUSIONS: Within the limitations of the study, the results support the assumption that EOSs for aerosol reduction increase in-treatment safety in the dental operatory.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/prevenção & controle , Humanos , Aerossóis e Gotículas Respiratórios
3.
Nanomaterials (Basel) ; 11(4)2021 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-33924560

RESUMO

In pharmaceutical development, more and more drugs are classified as poorly water-soluble or insoluble. Particle size reduction is a common way to fight this trend by improving dissolution rate, transport characteristics and bioavailability. Pulsed laser ablation is a ground-breaking technique of drug particle generation in the nano- and micrometer size range. Meloxicam, a commonly used nonsteroidal anti-inflammatory drug with poor water solubility, was chosen as the model drug. The pastille pressed meloxicam targets were irradiated by a Ti:sapphire laser (τ = 135 fs, λc = 800 nm) in air and in distilled water. Fourier transform infrared and Raman spectroscopies were used for chemical characterization and scanning electron microscopy to determine morphology and size. Additional particle size studies were performed using a scanning mobility particle sizer. Our experiments demonstrated that significant particle size reduction can be achieved with laser ablation both in air and in distilled water without any chemical change of meloxicam. The size of the ablated particles (~50 nm to a few microns) is approximately at least one-tenth of the size (~10-50 micron) of commercially available meloxicam crystals. Furthermore, nanoaggregate formation was described during pulsed laser ablation in air, which was scarcely studied for drug/organic molecules before.

4.
PLoS One ; 16(2): e0246543, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33539439

RESUMO

Dental turbines and scalers, used every day in dental operatories, feature built-in water spray that generates considerable amounts of water aerosol. The problem is that it is not exactly known how much. Since the outbreak of COVID-19, several aerosol safety recommendations have been issued-based on little empirical evidence, as almost no data are available on the exact aerosol concentrations generated during dental treatment. Similarly, little is known about the differences in the efficacy of different commercially available aerosol control systems to reduce in-treatment aerosol load. In this in vitro study, we used spectrometry to explore these questions. The time-dependent effect of conventional airing on aerosol concentrations was also studied. Everyday patient treatment situations were modeled. The test setups were defined by the applied instrument and its spray direction (high-speed turbine with direct/indirect airspray or ultrasonic scaler with indirect airspray) and the applied aerosol control system (the conventional high-volume evacuator or a lately introduced aerosol exhaustor). Two parameters were analyzed: total number concentration in the entire measurement range of the spectrometer and total number concentration within the 60 to 384 nm range. The results suggest that instrument type and spray direction significantly influence the resulting aerosol concentrations. Aerosol generation by the ultrasonic scaler is easily controlled. As for the high-speed turbine, the efficiency of control might depend on how exactly the instrument is used during a treatment. The results suggest that scenarios where the airspray is frequently directed toward the air of the operatory are the most difficult to control. The tested control systems did not differ in their efficiency, but the study could not provide conclusive results in this respect. With conventional airing through windows with a standard fan, a safety airing period of at least 15 minutes between treatments is recommended.


Assuntos
Aerossóis/efeitos adversos , Instrumentos Odontológicos/virologia , Odontologia/métodos , Aerossóis/administração & dosagem , Aerossóis/análise , COVID-19/etiologia , Desenho de Equipamento , Humanos , Tamanho da Partícula , SARS-CoV-2/isolamento & purificação
5.
Sci Rep ; 10(1): 15806, 2020 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-32978489

RESUMO

We studied the application of pulsed laser ablation (PLA) for particle size reduction in non-steroidal anti-inflammatory drugs (NSAIDs). Grinding of the poorly water-soluble NSAID crystallites can considerably increase their solubility and bioavailability, thereby the necessary doses can be reduced significantly. We used tablets of ibuprofen, niflumic acid and meloxicam as targets. Nanosecond laser pulses were applied at various wavelengths (KrF excimer laser, λ = 248 nm, FWHM = 18 ns and Nd:YAG laser, λ1 = 532 nm/λ2 = 1064 nm, FWHM = 6 ns) and at various fluences. FTIR and Raman spectra showed that the chemical compositions of the drugs had not changed during ablation at 532 nm and 1064 nm laser wavelengths. The size distribution of the ablated products was established using two types of particle size analyzers (SMPS and OPC) having complementary measuring ranges. The mean size of the drug crystallites decreased from the initial 30-80 µm to the submicron to nanometer range. For a better understanding of the ablation mechanism we made several investigations (SEM, Ellipsometry, Fast photography) and some model calculations. We have established that PLA offers a chemical-free and simple method for the size reduction of poorly water-soluble drugs and a possible new way for pharmaceutical drug preformulation for nasal administration.


Assuntos
Anti-Inflamatórios não Esteroides/química , Ibuprofeno/química , Terapia a Laser/métodos , Meloxicam/química , Ácido Niflúmico/química , Anti-Inflamatórios não Esteroides/efeitos da radiação , Ibuprofeno/efeitos da radiação , Lasers de Estado Sólido , Meloxicam/efeitos da radiação , Ácido Niflúmico/efeitos da radiação , Tamanho da Partícula
6.
Respir Res ; 17: 26, 2016 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-26966003

RESUMO

BACKGROUND: Several epidemiological and laboratory studies have evidenced the fact that atmospheric particulate matter (PM) increases the risk of respiratory morbidity. It is well known that the smallest fraction of PM (PM1 - particulate matter having a diameter below 1 µm) penetrates the deepest into the airways. The ratio of the different size fractions in PM is highly variable, but in industrial areas PM1 can be significant. Despite these facts, the health effects of PM1 have been poorly investigated and air quality standards are based on PM10 and PM2.5 (PM having diameters below 10 µm and 2.5 µm, respectively) concentrations. Therefore, this study aimed at determining whether exposure to ambient PM1 at a near alert threshold level for PM10 has respiratory consequences in rats. METHODS: Rats were either exposed for 6 weeks to 100 µg/m(3) (alert threshold level for PM10 in Hungary) urban submicron aerosol, or were kept in room air. End-expiratory lung volume, airway resistance (Raw) and respiratory tissue mechanics were measured. Respiratory mechanics were measured under baseline conditions and following intravenous methacholine challenges to characterize the development of airway hyperresponsiveness (AH). Bronchoalveolar lavage fluid (BALF) was analyzed and lung histology was performed. RESULTS: No significant differences were detected in lung volume and mechanical parameters at baseline. However, the exposed rats exhibited significantly greater MCh-induced responses in Raw, demonstrating the progression of AH. The associated bronchial inflammation was evidenced by the accumulation of inflammatory cells in BALF and by lung histology. CONCLUSIONS: Our findings suggest that exposure to concentrated ambient PM1 (mass concentration at the threshold level for PM10) leads to the development of mild respiratory symptoms in healthy adult rats, which may suggest a need for the reconsideration of threshold limits for airborne PM1.


Assuntos
Hiper-Reatividade Brônquica/induzido quimicamente , Hiper-Reatividade Brônquica/fisiopatologia , Bronquite/induzido quimicamente , Bronquite/fisiopatologia , Exposição Ambiental/efeitos adversos , Material Particulado/efeitos adversos , Animais , Hiper-Reatividade Brônquica/patologia , Bronquite/patologia , Cidades , Hungria , Masculino , Tamanho da Partícula , Ratos , Ratos Wistar , Mecânica Respiratória/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...