Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 40(8): 913-917, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28512774

RESUMO

Medical devices increasingly depend on software. While this expands the ability of devices to perform key therapeutic and diagnostic functions, reliance on software inevitably causes exposure to hazards of security vulnerabilities. This article uses a recent high-profile case example to outline a proactive approach to security awareness that incorporates a scientific, risk-based analysis of security concerns that supports ongoing discussions with patients about their medical devices.


Assuntos
Eletrofisiologia Cardíaca , Segurança Computacional , Desfibriladores Implantáveis , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Marca-Passo Artificial , Humanos , Guias de Prática Clínica como Assunto
2.
JACC Clin Electrophysiol ; 3(6): 623-631, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-29759437

RESUMO

OBJECTIVES: This study sought to develop a validated, reproducible sterilization protocol, which could be used in the reprocessing of cardiac implantable electronic devices (CIEDs). BACKGROUND: Access to cardiac CIED therapy in high-income and in low- and middle-income countries varies greatly. CIED reuse may reduce this disparity. METHODS: A cleaning and sterilization protocol was developed that includes washing CIEDs in an enzymatic detergent, screw cap and set screw replacement, brushing, inspection, and sterilization in ethylene oxide. Validation testing was performed to assure compliance with accepted standards. RESULTS: With cleaning, the total mean bioburden for each of 3 batches of 10 randomly chosen devices was reduced from 754 to 10.1 colony-forming units. After sterilization with ethylene oxide, with 3 half-cycle and 3 full-cycle processes, none of the 90 biological indicator testers exhibited growth after 7 days. Through cleaning and sterilization, protein and hemoglobin concentrations were reduced from 99.2 to 1.42 µg/cm2 and from 21.4 to 1.03 µg/cm2, respectively. Mean total organic carbon residual was 1.44 parts per million (range 0.36 to 2.9 parts per million). Endotoxin concentration was not detectable at the threshold of <0.03 endotoxin units/ml or <3.0 endotoxin units/device. Cytotoxicity and intracutaneous reactivity tests met the standards set by the Association for Advancement of Medical Instrumentation and the International Organization for Standardization. CONCLUSIONS: CIEDs can be cleaned and sterilized according to a standardized protocol achieving a 12-log reduction of inoculated product, resulting in sterility assurance level of 10-6.


Assuntos
Desfibriladores Implantáveis , Reutilização de Equipamento , Esterilização , Detergentes/uso terapêutico , Reutilização de Equipamento/normas , Humanos , Reprodutibilidade dos Testes , Esterilização/métodos , Esterilização/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...