Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Curr Oncol ; 27(3): e259-e264, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32669931

RESUMO

Background: Gastric stump ("remnant") cancer is the development of a malignancy related to previous gastric surgery. Prognosis in gastric stump cancer, compared with that in primary gastric cancer, is still controversial. Methods: From January 1988 to December 2012 at a single medical centre in Taiwan, 105 patients with gastric stump cancer, including 85 with previous peptic ulcer disease and 20 with previous gastric cancer, were analyzed for clinicopathologic characteristics and overall survival (os). Results: The 5-year os rates for patients with gastric stump cancer and with primary gastric cancer were 51.2% and 54.5% respectively (p = 0.035). Analysis of clinicopathologic characteristics indicated that, compared with patients having primary gastric cancer, those with gastric stump cancer had more lymph node metastasis (p < 0.001) and had been diagnosed at a more advanced stage (p = 0.047). Multivariate analysis with os as an endpoint showed that age [p = 0.015; hazard ratio (hr): 2.300; 95% confidence interval (ci): 1.173 to 4.509], tumour size (p = 0.037; hr: 1.700; 95% ci: 1.031 to 2.801), stromal reaction (p = 0.021; hr: 1.802; 95% ci: 1.094 to 2.969), and pathologic N category (p = 0.001; hr: 1.449; 95% ci: 1.161 to 1.807) were independent predictors in gastric stump cancer. The os rates for patients with gastric stump cancer who previously had gastric cancer or peptic ulcer disease were 72.9% and 50.0% respectively (p = 0.019). The Borrmann classification was more superficial (p = 0.005), lymph node metastases were fewer (p = 0.004), and staging was less advanced (p = 0.025) in patients with gastric stump cancer who previously had gastric cancer than in their counterparts who previously had peptic ulcer disease. Conclusions: Survival is poorer in patients with gastric stump cancer who previously had peptic ulcer disease than in those who previously had primary gastric cancer. Patients with gastric stump cancer who previously had gastric cancer and could receive curative gastrectomy tended to have a better prognosis because of a more superficial Borrmann classification. Regular follow-up in patients who have undergone gastric surgery is recommended for the early detection of gastric stump cancer.


Assuntos
Coto Gástrico/fisiopatologia , Neoplasias Gástricas/complicações , Neoplasias Gástricas/cirurgia , Idoso , Feminino , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Neoplasias Gástricas/mortalidade , Análise de Sobrevida
2.
Nanotechnology ; 24(11): 115709, 2013 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-23455619

RESUMO

Various seed layers were prepared on a Si substrate using the sol-gel (SG) or hydrothermal (HT) method and then ZnO nanocrystal was grown on the seed layer by an HT process. Au/ZnO nanocrystal Schottky diodes (SDs) were fabricated to study the effects of various seed layers on the electrical properties of Au/ZnO SDs. The observations showed that large numbers of Zn vacancies were present near the interface of Au/ZnO with an HT seed layer. The Zn vacancy plays an acceptor-like role, which raises the barrier height of the Au/ZnO SDs to 0.79 eV with a rectifying ratio of more than 8000. Hence, a non-surface-treated Au/ZnO SD was achieved as compared to those of other reported oxygen-plasma treated surfaces. In contrast, oxygen vacancies appear near the interface of Au/ZnO with an SG seed layer. The O vacancy plays a donor-like role, which reduces the barrier height of Au/ZnO, leading to an Ohmic behavior in the I-V characteristics. Zn out-diffusion is found during Au evaporation by of x-ray photoelectron spectroscopy measurements.

3.
Cytometry ; 36(3): 169-75, 1999 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-10404964

RESUMO

We report on far-field fluorescence imaging of single molecules in spherical polymer microparticles produced from solution by using microdroplet techniques. The fluorescence photobleaching quantum yields of rhodamine 6G in a common water-soluble polymer (polyvinyl alcohol) are at least five times smaller, corresponding to proportionally larger average fluorescence signals, than those in ethanolic solvents. This allows for acquisition of multiple images from a single molecule on a time scale of several minutes. We also show that fluorescent images of single molecules in microspheres can be calculated from semiclassic electrodynamics, which may ultimately be useful in retrieving dynamical information from experimental images.


Assuntos
Corantes Fluorescentes , Microscopia de Fluorescência/métodos , Polímeros , Rodaminas , Fluorescência , Microesferas , Álcool de Polivinil
4.
Opt Lett ; 24(3): 121-3, 1999 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-18071427

RESUMO

We show that homogeneous polymer blend microparticles can be prepared in situ from droplets of dilute solution of codissolved polymers. Provided that the droplet of solution is small enough (<10 mum), solvent evaporation is rapid enough to inhibit phase separation. Thus the polymers that are being mixed need not be miscible, which greatly enhances the applicability of the technique. From analysis of two-dimensional Fraunhofer diffraction (angular scattering) patterns, we show that both the real and the imaginary parts of the refractive index can be tuned by adjustment of the relative weight fractions of polymers in solution.

5.
Appl Opt ; 38(9): 1481-7, 1999 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-18305770

RESUMO

We describe instrumentation for real-time detection of single-molecule fluorescence in guided streams of 1-microm (nominal) water droplets. In this technique, target molecules were confined to droplets whose volumes were comparable with illumination volumes in diffraction-limited fluorescence microscopy and guided to the waist of a cw probe laser with an electrostatic potential. Concentration detection limits for Rhodamine 6G in water were determined to be approximately 1 fM, roughly 3 orders of magnitude lower than corresponding limits determined recently with diffraction-limited microscopy techniques for a chemical separation of similar dyes. In addition to its utility as a vehicle for probing single molecules, instrumentation for producing and focusing stable streams of 1-2-microm-diameter droplets may have other important analytical applications as well.

6.
Opt Lett ; 23(12): 951-3, 1998 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-18087394

RESUMO

We show that ultrasensitive microdroplet-stream fluorescence techniques combined with surfactant forms of Rhodamine dyes can be used to probe single molecules on the surfaces of spherical microcavities. Individual octadecyl Rhodamine B molecules, shown previously by ensemble measurements to be localized and oriented at the surfaces of liquid microspheres, were spatially photoselected primarily along great circles lying perpendicular or parallel to the detection axis by use of polarized laser excitation. A polarization dependence is observed in the distribution of single-molecule fluorescence amplitudes that can be interpreted qualitatively in terms of position-dependent fluorescence-collection efficiencies.

7.
Anal Chem ; 70(3): 658-61, 1998 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-21644763

RESUMO

We report observation of fluorescence from individual rhodamine 6G molecules in streams of charged 1-µm-diameter water droplets. With this approach, illumination volumes comparable to diffraction-limited fluorescence microscopy techniques (≤500 aL) are achieved, resulting in similarly high contrast between single-molecule fluorescence signals and nonfluorescent background. However, since the fluorescent molecules are confined to electrically charged droplets, in situ electrodynamic manipulation (e.g., focusing, switching, or merging) can be accomplished in a straightforward manner, allowing experimental control over both the delivery of molecules of interest to the observation region and the laser-molecule interaction time. As illustrated by photocount statistics that are independent of molecular diffusion and spatial characteristics of the excitation field, individual rhodamine 6G molecules in 1-µm droplets are reproducibly delivered to a target a few micrometers in diameter at a rate of between 10 and 100 Hz, with laser beam transit times more than 1 order of magnitude longer than diffusion-limited laser-molecule interaction times in equivalent volumes of free solution.

8.
Opt Lett ; 22(16): 1265-7, 1997 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-18185815

RESUMO

We report real-time observation of fluorescence bursts from individual Rhodamine 6G molecules in streams of microdroplets (peak signal-to-noise ratios, approximately 30) whose trajectories are constrained with a linear electric quadrupole. This approach offers a reasonable dynamic range in droplet size (3- 12-microm diameter) with <1% shot-to-shot size fluctuations and sensitivity comparable with that of droplet levitation techniques with at least 10(3) higher analysis rates. Applications to the study of single-molecule microcavity effects and stimulated emission are discussed.

9.
Anal Chem ; 69(11): 2115-21, 1997 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-21639255

RESUMO

We report fluorescence detection of individual rhodamine 6G molecules using a linear quadrupole to focus streams of microdroplets through the waist of a counterpropagating cw Ar(+) laser. Since the terminal velocity scales as the square of the droplet diameter, the droplet-laser interaction time was "tunable" between 5 and 200 ms by using water samples spiked with a small, variable (2-5% v/v) amount of glycerol. Fluorescence bursts from droplets containing single molecules were clearly distinguished from the blanks in real time with an average signal-to-noise ratio of about 10, limited primarily by photobleaching and droplet size fluctuations (<1%). The volume throughput rates associated with this approach (∼10 pL/s) are roughly 10(3) higher than those associated with particle levitation techniques, with minimal sacrifice in sensitivity. Total molecular detection efficiencies of about 80% (at >99% confidence) were obtained for 100 and 15 fM rhodamine 6G solutions, in good agreement with detailed theoretical calculations and statistical limitations.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...