Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Med Biochem ; 42(3): 536-539, 2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37790211

RESUMO

The pre-analytical phase is the principal source of errors in laboratory medicine and continues to pose a challenge to laboratory professionals. We present the case of a 73-yearold female patient with a very low hemoglobin level (69 g/L) and positive indirect antiglobulin test result that indicates the key role of phlebotomy as an important error-prone process in which mistakes can have serious consequences for the patient's diagnosis and treatment. We conclude that there is still an urgent and continuous need to provide educational activities for healthcare professionals involved in blood collection, improve blood collection guideline adherence, and eliminate the errors which can affect diagnosis and treatment, thus jeopardising patient safety.

2.
Ann Hematol ; 94(10): 1741-8, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26122868

RESUMO

Bone marrow macroscopic examination remains one of the most difficult and subjective laboratory assessments in hematology. Only a few external quality assurance programs in the field are present worldwide. We have developed an external quality assurance program EQAhem that allows assessment of the whole process of bone marrow examination. The program participants assess blood and bone marrow smears from the patient, identify selected cells from photographs provided to them, and interpret the microscopic results. In this article, the results of the EQAhem program in Poland from 6 years are summarized. During this time, 62 labs were assessed in total, and positive results were achieved by 89.25 % labs, taking into account all tests. Correct responses with respect to the percentage of cell count were provided by ca. 77.5 % labs. Slightly worse results were obtained when megakaryocyte count and cell identification from photographs were tested. The worst results were obtained in case of dysplasia assessment and clinical interpretation of microscopic examination (54.1 and 58.6 % correct responses, respectively). EQAhem delivers precise information about the quality of bone marrow examinations performed in Poland and has a substantial educational value. We believe that after 6 years, EQAhem has significantly improved the quality of bone marrow microscopic examinations performed in Poland.


Assuntos
Células da Medula Óssea , Garantia da Qualidade dos Cuidados de Saúde/normas , Manejo de Espécimes/normas , Exame de Medula Óssea/normas , Contagem de Células/normas , Técnicas de Laboratório Clínico/normas , Humanos , Polônia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA