Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Transplant Proc ; 50(10): 3113-3120, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30577176

RESUMO

BACKGROUND: To analyze our initial results of hand-assisted laparoscopic living donor nephrectomy, executed by a skilled gastrointestinal surgeon. METHODS: A total of 22 consecutive patients underwent the hand-assisted laparoscopic living donor nephrectomy between December 2014 and January 2017. We retrospectively analyze the patient's perioperative clinical data, which were collected prospectively. RESULTS: The right kidney was harvested in 12 patients. The mean operative time and intraoperative blood loss was 241.0 ± 43.4 minutes (range, 140-310 min) and 293.2 ± 203.1 mL (range, 50-700 mL), respectively. The mean warm ischemic time was 288.4 ± 103.4 seconds (range, 179-610 s). Postoperative complications included chyle leakage in 2 patients who were left kidney donors and oliguria in 1 patient who was a right kidney donor. All patients recovered with conservative care, and the mean hospital stay was 7.5 ± 1.7 days. The mean creatinine level was 0.7 ± 0.2 mg/dL before surgery, 1.1 ± 0.3 mg/dL at postoperative day (POD) 1, and 1.0 ± 0.2 mg/dL after discharge. The mean glomerular filtration rate was 97.9 ± 18.2 mL/min/1.73 m2 before surgery, 60.7 ± 10.4 at POD 1, and 67.3 ± 11.1 after discharge. Operation time was not associated with patient body mass index and case number. No significant differences, other than postoperative complications, were found in the perioperative data for the side of kidney donation. CONCLUSION: A skilled surgeon with experience in laparoscopic abdominal surgery (such as gastrectomy or colectomy) might safely perform hand-assisted donor nephrectomy. However, we could not identify a clear case number to complete the learning curve.


Assuntos
Cirurgia Geral/educação , Laparoscopia Assistida com a Mão/educação , Transplante de Rim/educação , Nefrectomia/educação , Coleta de Tecidos e Órgãos/educação , Adulto , Perda Sanguínea Cirúrgica , Feminino , Taxa de Filtração Glomerular , Laparoscopia Assistida com a Mão/efeitos adversos , Laparoscopia Assistida com a Mão/métodos , Humanos , Transplante de Rim/efeitos adversos , Transplante de Rim/métodos , Curva de Aprendizado , Tempo de Internação , Doadores Vivos , Masculino , Pessoa de Meia-Idade , Nefrectomia/efeitos adversos , Nefrectomia/métodos , Duração da Cirurgia , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Coleta de Tecidos e Órgãos/métodos , Isquemia Quente
2.
Artigo em Inglês | MEDLINE | ID: mdl-21108095

RESUMO

A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method as an alternative to a gas chromatography-thermal energy analyser (GC-TEA) method recommended by the European Committee on Standardization (CEN) was validated for the simultaneous determination of eight N-nitrosamines released into artificial saliva from rubber or elastomer teats and soothers. N-nitroso-dipropylamine-d14 (NDPA-d14) was used as internal standard for accurate quantification. The method was validated with relatively good analytical results, including sufficiently low limits of detection (0.1-2 µg kg⁻¹) of sample) and good linearity (r²> 0.99) throughout the studied concentration ranges. Intra- and inter-day precisions expressed with the relative standard deviation (RSD, %) were 3.4-8.0% and 4.4-11.3%, which were below the performance criteria based on one-half of the value derived from the Horwitz value. It was also found that the LC-MS/MS method is sufficiently rugged and successfully applicable to its routine analysis for the compliance test of Commission Directive 93/11/EEC.


Assuntos
Alimentação com Mamadeira/instrumentação , Carcinógenos/análise , Elastômeros/química , Nitrosaminas/análise , Chupetas , Borracha/química , Saliva/química , Alimentação com Mamadeira/efeitos adversos , Carcinógenos/química , Cromatografia Líquida de Alta Pressão , Qualidade de Produtos para o Consumidor , Humanos , Lactente , Limite de Detecção , Modelos Biológicos , Nitrosaminas/química , Chupetas/efeitos adversos , Reprodutibilidade dos Testes , República da Coreia , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem
7.
Mem Inst Oswaldo Cruz ; 90(1): 75-9, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-8524089

RESUMO

Wild type and mutant toxins of Bacillus thuringiensis delta-endotoxins were examined for their binding to midgut brush border membrane vesicles (BBMV). CryIAa, CryIAb, and CryIAc were examined for their binding to Gypsy moth (Lymantria dispar) BBMV. The binding of CryIAa and CryIAc was directly correlated with their toxicity, while CryIAb was observed to have lower binding than expected from its toxicity. The latter observation confirms the observation of Wolfersberger (1990). The "rule" of reciprocity of binding and toxicity is apparently obeyed by CryIAa and CryIAc, but broken by CryIAb on L. dispar. Alanine substitutions were made in several positions of the putative loops of CryIAa to test the hypothesis that the loops are intimately involved in binding to the receptor. The mutant toxins showed minor shifts in heterologous binding to Bombyx mori BBMV, but not enough to conclude that the residues chosen play critical roles in receptor binding.


Assuntos
Bacillus thuringiensis , Endotoxinas/metabolismo , Receptores Imunológicos/metabolismo , Sequência de Aminoácidos , Animais , Ligação Competitiva , Dados de Sequência Molecular , Conformação Proteica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...