Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 6: 32300, 2016 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-27562634

RESUMO

Artificially designed acoustic meta-surfaces have the ability to manipulate sound energy to an extraordinary extent. Here, we report on a new type of directional reflective surface consisting of an array of sub-wavelength Helmholtz resonators with varying internal coiled path lengths, which induce a reflection phase gradient along a planar acoustic meta-surface. The acoustically reshaped reflective surface created by the gradient-impeding meta-surface yields a distinct focal line similar to a parabolic cylinder antenna, and is used for directive sound beamforming. Focused beam steering can be also obtained by repositioning the source (or receiver) off axis, i.e., displaced from the focal line. Besides flat reflective surfaces, complex surfaces such as convex or conformal shapes may be used for sound beamforming, thus facilitating easy application in sound reinforcement systems. Therefore, directional reflective surfaces have promising applications in fields such as acoustic imaging, sonic weaponry, and underwater communication.


Assuntos
Acústica/instrumentação , Localização de Som , Espectrografia do Som/instrumentação , Som , Estimulação Acústica , Algoritmos , Humanos , Modelos Teóricos , Processamento de Sinais Assistido por Computador , Espectrografia do Som/métodos
2.
Sensors (Basel) ; 15(8): 18851-64, 2015 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-26263995

RESUMO

This paper presents the development of a piezoelectric artificial cochlea (PAC) device capable of analyzing vibratory signal inputs and converting them into electrical signal outputs without an external power source by mimicking the function of human cochlea within an audible frequency range. The PAC consists of an artificial basilar membrane (ABM) part and an implantable packaged part. The packaged part provides a liquid environment through which incoming vibrations are transmitted to the membrane part. The membrane part responds to the transmitted signal, and the local area of the ABM part vibrates differently depending on its local resonant frequency. The membrane was designed to have a logarithmically varying width from 0.97 mm to 8.0 mm along the 28 mm length. By incorporating a micro-actuator in an experimental platform for the package part that mimics the function of a stapes bone in the middle ear, we created a similar experimental environment to cochlea where the human basilar membrane vibrates. The mechanical and electrical responses of fabricated PAC were measured with a laser Doppler vibrometer and a data acquisition system, and were compared with simulation results. Finally, the fabricated PAC in a biocompatible package was developed and its mechanical and electrical characteristics were measured. The experimental results shows successful frequency separation of incoming mechanical signal from micro-actuator into frequency bandwidth within the 0.4 kHz-5 kHz range.


Assuntos
Materiais Biocompatíveis/química , Implantes Cocleares , Eletricidade , Fenômenos Mecânicos , Embalagem de Produtos , Desenho de Prótese , Análise de Elementos Finitos , Humanos , Processamento de Sinais Assistido por Computador , Vibração
3.
Sci Rep ; 4: 7421, 2014 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-25502279

RESUMO

The inherent attenuation of a homogeneous viscous medium limits radiation propagation, thereby restricting the use of many high-frequency acoustic devices to only short-range applications. Here, we design and experimentally demonstrate an acoustic metamaterial localization cavity which is used for sound pressure level (SPL) gain using double coiled up space like structures thereby increasing the range of detection. This unique behavior occurs within a subwavelength cavity that is 1/10(th) of the wavelength of the incident acoustic wave, which provides up to a 13 dB SPL gain. We show that the amplification results from the Fabry-Perot resonance of the cavity, which has a simultaneously high effective refractive index and effective impedance. We also experimentally verify the SPL amplification in an underwater environment at higher frequencies using a sample with an identical unit cell size. The versatile scalability of the design shows promising applications in many areas, especially in acoustic imaging and underwater communication.

4.
Sensors (Basel) ; 14(1): 117-28, 2013 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-24361926

RESUMO

In this research, we have developed a multi-channel piezoelectric acoustic sensor (McPAS) that mimics the function of the natural basilar membrane capable of separating incoming acoustic signals mechanically by their frequency and generating corresponding electrical signals. The McPAS operates without an external energy source and signal processing unit with a vibrating piezoelectric thin film membrane. The shape of the vibrating membrane was chosen to be trapezoidal such that different locations of membrane have different local resonance frequencies. The length of the membrane is 28 mm and the width of the membrane varies from 1 mm to 8 mm. Multiphysics finite element analysis (FEA) was carried out to predict and design the mechanical behaviors and piezoelectric response of the McPAS model. The designed McPAS was fabricated with a MEMS fabrication process based on the simulated results. The fabricated device was tested with a mouth simulator to measure its mechanical and piezoelectrical frequency response with a laser Doppler vibrometer and acoustic signal analyzer. The experimental results show that the as fabricated McPAS can successfully separate incoming acoustic signals within the 2.5 kHz-13.5 kHz range and the maximum electrical signal output upon acoustic signal input of 94 dBSPL was 6.33 mVpp. The performance of the fabricated McPAS coincided well with the designed parameters.


Assuntos
Acústica/instrumentação , Membrana Basilar , Membranas Artificiais , Modelos Teóricos
5.
ACS Nano ; 5(9): 7061-8, 2011 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-21838325

RESUMO

Three-dimensional microelectrodes were fabricated using glassy carbon electrodes combined with vertically aligned carbon nanotubes (VACNTs). VACNTs were grown on various conducting electrode patterns including a carbon electrode fabricated by pyrolysis of a negative photoresist, with plasma-enhanced chemical vapor deposition using a bilayer Fe/Al catalyst. VACNT electrodes grown on the glassy carbon showed excellent electrochemical behavior, whereas VACNT electrodes grown on Pt showed poor electrochemical performance, presumably due to the poor contact between VACNTs and the Pt electrode. Electron microscopy showed that the VACNT layer was strongly bound to the carbon electrode, while that on Pt tended to peel away. The versatility of the all-carbon microelectrodes was also tested by using them for interfacing stem cells. Their superior mechanical properties and the electrical connectivity between the carbon electrode and the VACNTs, along with the simple fabrication process, suggest that glassy carbon may be a good conducting substrate for VACNT electrodes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...