Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 10(10)2021 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-34063464

RESUMO

OBJECTIVES: Our aim was to assess blood utilization after implementation of a patient blood management (PBM) program in a Greek tertiary hospital. METHODS: An electronic transfusion request form and a prospective audit of transfusion practice were implemented. After the one-year implementation period, a retrospective review was performed to assess transfusion practice in medical patients. RESULTS: Pre-PBM, a total of 9478 RBC units were transfused (mean: 1.75 units per patient) compared with 9289 transfused units (mean: 1.57 units per patient) post-PBM. Regarding the post-PBM period, the mean hemoglobin (Hb) level of the 3099 medical patients without comorbidities transfused was 7.19 ± 0.79 gr/dL. Among them, 2065 (66.6%) had Hb levels >7.0 gr/dL, while 167 (5.3%) had Hb levels >8.0 gr/dL. In addition, 331 (25.3%) of the transfused patients with comorbidities had Hb >8.0 gr/dL. The Hb transfusion thresholds significantly differed across the clinics (p < 0.001), while 21.8% of all medical non-bleeding patients received more than one RBC unit transfusion. CONCLUSION: A poor adherence with the restrictive transfusion threshold of 7.0 gr/dL was observed. The adoption of a less strict threshold might be a temporary step to allow physicians to become familiar with the program and be informed on the safety and advantages of the restrictive transfusion strategy.

2.
Food Chem Toxicol ; 141: 111389, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32343994

RESUMO

We examined the effects of electronic cigarette on platelet and vascular function after 4 months of use compared to tobacco smoking. Forty smokers without cardiovascular disease were randomized to smoke either conventional cigarettes or an electronic cigarette (nicotine concentration of 12 mg/ml). At baseline and after four months, we measured a) platelet function by Platelet Function Analyzer PFA-100 and Light Transmission Aggregometry, b) pulse wave velocity, c) plasma malondialdehyde levels as oxidative stress index and d) the exhaled CO level. After 4 months, continuation of conventional cigarette smoking further impaired platelet function compared to vaping as assessed by PFA (mean increase 27.1 vs 11.6 s, p for interaction = 0.048) and by LTA (decline 24.1 vs 9.4%, p for interaction = 0.045). Conversely, compared to smoking, vaping resulted in greater reduction of exhaled CO (6.9 ppm vs 2.6, p for interaction < 0.001), improvement of PWV (decrease of 0.8 m/s vs increase of 0.8 m/s, p for interaction = 0.020) and reduction of MDA (reduction 0.13 vs increase 0.19 nmol/L, p for interaction = 0.035). Switching to electronic cigarette for 4 months has a neutral effect on platelet function while it reduces arterial stiffness and oxidative stress compared to tobacco smoking.


Assuntos
Plaquetas/efeitos dos fármacos , Sistemas Eletrônicos de Liberação de Nicotina , Endotélio Vascular/efeitos dos fármacos , Nicotina/farmacologia , Endotélio Vascular/fisiologia , Humanos
3.
Thromb Res ; 180: 47-54, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31202191

RESUMO

AIM: Limited data are available regarding the clinical relevance of platelet function measurements in stable patients with coronary artery disease (CAD). Our aim is to evaluate the agreement between multiple electrode aggregometry (MEA) and light transmittance aggregometry (LTA) in detecting clopidogrel low responders and their prognostic value in CAD patients with type 2 diabetes mellitus (T2DM) on dual platelet inhibition. METHODS: LTA and MEA were performed in 122 stable cardiovascular patients with T2DM. The upper quartile of patients according to maximum LTA (LTAmax) and MEA measurements were defined as clopidogrel low responders. Agreement between the two methods was evaluated by kappa statistics. We assessed the potential correlation between antiplatelet response and clinical outcome and the optimal cutoff value according to ROC analysis to predict the occurrence of major adverse cardiovascular events (MACE), during 1-year follow-up period. RESULTS: Cohen's kappa coefficients (0.214) indicated fair agreement (70.2%) between LTA and MEA. A total of 25 MACE occurred in 108 patients (23.1%). Patients with MACE had higher LTAmax than those without (57.1 ±â€¯16.5 vs 49.3 ±â€¯18.3, respectively, p = 0.023). MEA measurements were similar between patients with and without MACE (30.1 ±â€¯15.4 vs 30.6 ±â€¯20.8, respectively; p = 0.84). Multiple logistic regression showed LTAmax response as an independent predictor of death from cardiovascular causes (Odds Ratio, adjusted:0.2;0.05-0.81). ROC analysis indicated that LTAmax cutoff of 62.5% best predicted death (AUC = 0.67, sensitivity = 78%, specificity = 61.5%). CONCLUSIONS: The assessment of platelet responsiveness remains highly test-specific. Our results support the prognostic role of LTA, but not MEA testing, for death risk evaluation in stable cardiovascular T2DM patients.


Assuntos
Doença da Artéria Coronariana/sangue , Diabetes Mellitus Tipo 2/sangue , Agregação Plaquetária , Idoso , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes de Função Plaquetária/instrumentação , Prognóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...