Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Intervalo de ano de publicação
2.
Braz J Cardiovasc Surg ; 35(1): 65-74, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32270962

RESUMO

OBJECTIVE: The aims of this study were to examine the incidence and in-hospital outcomes of surgical aortic valve replacement (SAVR) and to identify factors associated with in-hospital mortality (IHM) among patients according to the type of implanted valve used in SAVR. METHODS: We performed a retrospective study using the Spanish National Hospital Discharge Database, 2001-2015. We included patients who had SAVR listed as a procedure in their discharge report. RESULTS: We identified 86,578 patients who underwent SAVR (52.78% mechanical and 47.22% bioprosthetic). Incidence of SAVR coding increased significantly from 11.95 cases per 100,000 inhabitants in 2001 to 17.92 in 2015 (P<0.001). Age and comorbidities increased over time (P<0.001). There was a significant increase in the frequency of concomitant coronary artery bypass grafting (CABG) and in the use of pacemaker implantation. The use of mechanical SAVR decreased and the use of bioprosthetic valves increased over time. IHM decreased over time (from 8.13% in 2001-05 to 5.39% in 2011-15). Patients who underwent mechanical SAVR had higher IHM than those who underwent bioprosthetic SAVR (7.44% vs. 6%; P<0.05). Higher IHM rates were associated with advanced age, female sex, comorbidities, concomitant CABG, and the use of mechanical SAVR (OR 1.67; 95% CI 1.57-1.77). CONCLUSION: The number of SAVRs performed in Spain has increased since 2001. The use of mechanical SAVR has decreased and the use of bioprosthetic valves has increased over time. IHM has decreased over time for both types of valves and despite a concomitant increase in age and comorbidities of patients during the same period.


Assuntos
Implante de Prótese de Valva Cardíaca , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica , Estenose da Valva Aórtica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Retrospectivos , Fatores de Risco , Espanha , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
3.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;35(1): 65-74, Jan.-Feb. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1092469

RESUMO

Abstract Objective: The aims of this study were to examine the incidence and in-hospital outcomes of surgical aortic valve replacement (SAVR) and to identify factors associated with in-hospital mortality (IHM) among patients according to the type of implanted valve used in SAVR. Methods: We performed a retrospective study using the Spanish National Hospital Discharge Database, 2001-2015. We included patients who had SAVR listed as a procedure in their discharge report. Results: We identified 86,578 patients who underwent SAVR (52.78% mechanical and 47.22% bioprosthetic). Incidence of SAVR coding increased significantly from 11.95 cases per 100,000 inhabitants in 2001 to 17.92 in 2015 (P<0.001). Age and comorbidities increased over time (P<0.001). There was a significant increase in the frequency of concomitant coronary artery bypass grafting (CABG) and in the use of pacemaker implantation. The use of mechanical SAVR decreased and the use of bioprosthetic valves increased over time. IHM decreased over time (from 8.13% in 2001-05 to 5.39% in 2011-15). Patients who underwent mechanical SAVR had higher IHM than those who underwent bioprosthetic SAVR (7.44% vs. 6%; P<0.05). Higher IHM rates were associated with advanced age, female sex, comorbidities, concomitant CABG, and the use of mechanical SAVR (OR 1.67; 95% CI 1.57-1.77). Conclusion: The number of SAVRs performed in Spain has increased since 2001. The use of mechanical SAVR has decreased and the use of bioprosthetic valves has increased over time. IHM has decreased over time for both types of valves and despite a concomitant increase in age and comorbidities of patients during the same period.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto Jovem , Implante de Prótese de Valva Cardíaca , Valva Aórtica , Estenose da Valva Aórtica , Complicações Pós-Operatórias , Espanha , Fatores de Tempo , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA