Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Phys ; 47(4): 1930-1939, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31943221

RESUMO

PURPOSE: For determining small-field profile and output factor during stereotactic radiotherapy quality assurance (QA) procedures, we propose a novel system based on the scintillating fiber (SciFi) detector with output image acquisition and processing to allow real-time monitoring of profile and output factor. MATERIALS AND METHODS: The employed detector is a SciFi detector made of tissue-equivalent scintillating plastic fibers arranged in 6-layer fiber ribbons with a fiber pitch of 275 µm in each layer. The scintillating signal at the detector output is acquired by a sCMOS (scientific complementary metal-oxide-semiconductor) camera and represents the projected field profile along the fibers axis. An iterative reconstruction method of the field from its projected profile based on a priori knowledge of some features of the radiation field defined by the stereotactic cones is suggested. The detector with implemented data processing has been tested in clinical conditions, for determining beam profiles and output factors, using cone collimators of different sizes from 4 to 15 mm diameter. The detector under test was placed at 1.4 cm depth and 98.6 cm source to surface distance (SSD) in a water-equivalent phantom and irradiated by a 6 MV photon beam. RESULTS: The reconstructed field profiles obtained from the detector are coherent with data from EBT3 radiochromic films, with differences within ±0.32 mm for both the FWHM and the penumbra region. For real-time determination of the field output factor, the measured data are also in good agreement with data independently determined by the French Institute for Radiological Protection and Nuclear Safety (IRSN) based on radiochromic films and thermoluminescent 1 × 1 mm2 micro-cubes dosimeters (TLD). The differences are within ±1.6% for all the tested cone sizes. CONCLUSIONS: We propose and have tested a SciFi plastic scintillating detector with an optimized signal processing method to characterize small fields defined by cone collimators. It allows the determination of key field parameters such as full width at half maximum (FWHM) and field output factors. The results are consistent with those independently measured using TLD and radiochromic films. As the SciFi detector does not require a correction factor, it is in line with the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM) TRS-483 recommendations, and can be suitable for online QA of small radiation fields used in photon beam radiotherapy, and is compatible with MRI-LINAC.


Assuntos
Radiocirurgia/métodos , Aceleradores de Partículas , Radiocirurgia/instrumentação , Dosagem Radioterapêutica , Contagem de Cintilação/instrumentação , Fatores de Tempo
2.
Med Phys ; 43(9): 5240, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27587055

RESUMO

PURPOSE: High dose rate brachytherapy (HDR-BT) is widely used to treat gynecologic, anal, prostate, head, neck, and breast cancers. These treatments are typically administered in large dose per fraction (>5 Gy) and with high-gradient-dose-distributions, with serious consequences in case of a treatment delivery error (e.g., on dwell position and dwell time). Thus, quality assurance (QA) or quality control (QC) should be systematically and independently implemented. This paper describes the design and testing of a phantom and an instrumented gynecological applicator for pretreatment QA and in vivo QC, respectively. METHODS: The authors have designed a HDR-BT phantom equipped with four GaN-based dosimeters. The authors have also instrumented a commercial multichannel HDR-BT gynecological applicator by rigid incorporation of four GaN-based dosimeters in four channels. Specific methods based on the four GaN dosimeter responses are proposed for accurate determination of dwell time and dwell position inside phantom or applicator. The phantom and the applicator have been tested for HDR-BT QA in routine over two different periods: 29 and 15 days, respectively. Measurements in dwell position and time are compared to the treatment plan. A modified position-time gamma index is used to monitor the quality of treatment delivery. RESULTS: The HDR-BT phantom and the instrumented applicator have been used to determine more than 900 dwell positions over the different testing periods. The errors between the planned and measured dwell positions are 0.11 ± 0.70 mm (1σ) and 0.01 ± 0.42 mm (1σ), with the phantom and the applicator, respectively. The dwell time errors for these positions do not exhibit significant bias, with a standard deviation of less than 100 ms for both systems. The modified position-time gamma index sets a threshold, determining whether the treatment run passes or fails. The error detectability of their systems has been evaluated through tests on intentionally introduced error protocols. With a detection threshold of 0.7 mm, the error detection rate on dwell position is 22% at 0.5 mm, 96% at 1 mm, and 100% at and beyond 1.5 mm. On dwell time with a dwell time threshold of 0.1 s, it is 90% at 0.2 s and 100% at and beyond 0.3 s. CONCLUSIONS: The proposed HDR-BT phantom and instrumented applicator have been tested and their main characteristics have been evaluated. These systems perform unsupervised measurements and analysis without prior treatment plan information. They allow independent verification of dwell position and time with accuracy of measurements comparable with other similar systems reported in the literature.


Assuntos
Braquiterapia/instrumentação , Gálio , Ginecologia/instrumentação , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde , Doses de Radiação , Radiometria/instrumentação , Braquiterapia/normas , Desenho de Equipamento , Feminino , Humanos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Fatores de Tempo , Incerteza
3.
J Appl Microbiol ; 121(1): 196-206, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27005987

RESUMO

AIMS: To investigate the effects of long-term acid mine drainage (AMD) irrigation on the change in bacterial community and sulphate-reducing bacteria (SRB) in a paddy soil. METHODS AND RESULTS: The bacterial community structures were investigated using 454 pyrosequencing, and 98 931 effective sequences were selected for the bacterial diversity analysis. The known dominant phyla in the paddy soil were Acidobacteria (33·5%), Proteobacteria (19·7%), Nitrospira (2·8%) and Actinobacteria (2·7%). Higher percentage of Acidobacteria than Proteobacteria was detected. The relative abundances of the dominant bacterial lineages were more significantly correlated with the soil pH, the organic matter and the sulphate than the heavy metals. The diversity of the SRB in the surface paddy soil showed that the uncultured SRB groups might play important roles in paddy soils. The other OTUs mainly belonged to six phylogenetic divisions: Desulfobacca, Desulfovibrio, Syntrophobacter, Desulforhopalus, Desulfarculus and Desulfobulbus. The distribution of the absolute abundance and the relative contribution of the SRB along the vertical soil profile were investigated by RT-PCR assays based on the dsrB gene. The abundance of the dsrB gene copy numbers was up to 1·92 × 10(9)  copies g(-1) dry soil, which is slightly higher than the other non-AMD-affected paddy soil. CONCLUSIONS: This study demonstrated that the abundance of SRB is increased by the AMD irrigation while changing the composition and diversity of the bacterial community in the paddy soil. SIGNIFICANCE AND IMPACT OF THE STUDY: This is, to our knowledge, the first attempt to characterize and quantify changes in the diversity and distribution of the microbial community and SRB in the long-term AMD-irrigated paddy soil, which will further increase our understanding of the impact of AMD on sulphur biogeochemical cycling in the paddy soil.


Assuntos
Bactérias/isolamento & purificação , Bactérias/metabolismo , Biodiversidade , Microbiologia do Solo , Sulfatos/metabolismo , Irrigação Agrícola , Bactérias/classificação , Bactérias/genética , Mineração , Oxirredução , Filogenia , RNA Ribossômico 16S/genética , Solo/química , Sulfatos/análise
4.
Phys Med ; 29(5): 487-92, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23317814

RESUMO

For dosimetric measurements using an implantable optical fiber probe with GaN (Gallium Nitride) scintillator as radioluminescence (RL) transducer, a bi-channel method is proposed to reject the background contribution of the irradiated fiber segment. It is based on spectral differences between the narrow-band light emission from GaN and the large-band background from the irradiated optical fiber. Experimental validation of this method using 6 MV photon beam has shown that the remaining background contribution after subtraction is below 1.2% for square field sizes ranging from 3 cm to 20 cm. Furthermore, a compensation method for the over-response of GaN is also proposed, since GaN is not tissue equivalent. The over-response factor of GaN exhibits a linear increase with square field aperture and depends on depth from phantom surface. This behaviour is modelled to allow compensation in specific conditions. The proposed method has been evaluated and has shown a maximum deviation of 3% for a 6 MV photon beam and 1% for an 18 MV photon beam at a depth beyond the build-up region.


Assuntos
Gálio/química , Fibras Ópticas , Radiometria/instrumentação , Artefatos , Calibragem , Reprodutibilidade dos Testes
5.
J Hazard Mater ; 181(1-3): 1158-62, 2010 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-20638971

RESUMO

Four oil component-degrading bacteria and one oil-tolerant microalgae, Scenedesmus obliquus GH2, were used to construct an artificial microalgal-bacterial consortium for crude-oil degradation. The bacterial strains included Sphingomonas GY2B and Burkholderia cepacia GS3C, along with a mixed culture, named GP3, containing Pseudomonas GP3A and Pandoraea pnomenusa GP3B. GY2B could only degrade polycyclic aromatic hydrocarbons, GS3C was able to degrade aliphatic chain hydrocarbons, and GP3 could utilize both saturated and aromatic hydrocarbons. In combination with unialgal or axenic algae, the bacteria showed different effects on oil degradation. Unialgal GH2 was not suitable for the consortium construction, as it could not cooperate well with GS3C and GP3. The axenic GH2 exhibited no oil-degrading ability; however, it significantly promoted the degradation ability of the oil component-degrading bacteria, especially for degrading biorefractory polycyclic aromatic hydrocarbons. Axenic S. obliquus GH2, combined with the four bacteria mentioned above, formed an optimal algal-bacterial consortium. The artificial consortium demonstrated an elevated efficiency in degrading both aliphatic and aromatic hydrocarbons of crude oil.


Assuntos
Bactérias/metabolismo , Biodegradação Ambiental , Eucariotos/metabolismo , Petróleo/metabolismo , Alcanos/metabolismo , Hidrocarbonetos Aromáticos/metabolismo
6.
Cancer Radiother ; 13(3): 182-9, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19272824

RESUMO

The quality insurance in radiotherapy in the frame of highly complex technical process as Intensity modulated radiotherapy (IMRT) needs independent control of the delivered dose to the patient. Actually, up to now, most of the radiotherapy treatments rely only on computed dosimetry through a rather complicated series of linked simulation tool. This dosimetry approach requires also qualified treatment means based on cautious quality insurance procedures. However, erroneous parameters could be difficult to detect and systematical errors could happen leading to radiotherapy accidents. In this context, in vivo dosimetry has a critical role of final control of the delivered dose. As many beam incidences and ports are used for any photontherapy treatment, external control could be very tedious and time consuming. Therefore, innovations are needed for in vivo dosimetry to provide ergonomic and efficient tools for these controls. This paper presents a review of technologies and products that can be used for in vivo dosimetry. It proposes also a reflection on the concepts to develop future devices suitable for this purpose. The technical means with their physical principles are reviewed, the clinical experiences demonstrating the feasibility of new techniques are then summarized and finally, the early clinical use and its impact on clinical practice is review.


Assuntos
Neoplasias/radioterapia , Monitoramento de Radiação/métodos , Radiometria/métodos , Humanos , Garantia da Qualidade dos Cuidados de Saúde , Monitoramento de Radiação/instrumentação , Radiometria/instrumentação , Dosagem Radioterapêutica
7.
Sci China B ; 36(9): 1110-6, 1993 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8274204

RESUMO

The miniature endplate currents (MEPC's) were recorded at the neuromuscular junction of Xenopus laevis embryo neuron-muscle co-cultured cells. These MEPC's were due to the spontaneous release of acetylcholine from the nerve terminal. After perfusion with glutamate (10 mumol/L), both frequency and amplitude of the MEPC's increased. After washing away of glutamate, this effect persisted. We named this phenomena "Long-Term Facilitation". GABA (20 mumol/L) on the other hand had an inhibitory effect on both frequency and amplitude of the MEPC's. After washing away of GABA, the MEPC frequency and amplitude increased. We named this effect "Post-Potentiation". Local perfusion experiments furthermore indicated that the effect of glutamate was restricted to the neuromuscular junction, the effect of GABA was restricted to the soma.


Assuntos
Acetilcolina/metabolismo , Glutamatos/farmacologia , Junção Neuromuscular/metabolismo , Ácido gama-Aminobutírico/farmacologia , Potenciais de Ação/efeitos dos fármacos , Animais , Células Cultivadas , Potenciais da Membrana/efeitos dos fármacos , Placa Motora/fisiologia , Xenopus laevis/embriologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...