1.
Int J Cardiol ; 323: 208-212, 2021 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-32795480

RESUMO

INTRODUCTION: Accurate predictors of good clinical response after MitraClip implant in patients with heart failure (HF) are still lacking. Aim of this study was to investigate the role of regurgitant fraction >50% as a marker of disproportionate functional mitral regurgitation (FMR) in identifying best responders to Mitraclip. METHODS AND RESULTS: Data from 58 advanced HF patients (age 66 ±â€¯8 years, 81% males, 63% NYHA class IV, LV ejection fraction (EF) 25.5 ±â€¯5.5%) with disproportionate and proportionate FMR who underwent successful MitraClip implant were analyzed. After MitraClip all patient achieved mild (≤ 2+/4+) MR. During 12-month follow-up 18 patients (31%) had a major adverse cardiac event (MACE, i.e. cardiac death, urgent LVAD implant or heart transplantation, HF hospitalization). Disproportionate FMR (n = 48, 83%) was associated with a better clinical outcome (p = .003) while regurgitant volume and EROA were not. TAPSE ≤14 mm was associated with worse outcome (p = .018). At multivariable analysis only disproportionate MR and TAPSE ≤14 mm showed a significant association with MACE (p = .017 and p = .02, respectively). A reverse left ventricular remodeling (i.e., reduction on LV end-diastolic diameter and end-diastolic volume) was achieved only in the disproportionate FMR group. CONCLUSIONS: In conclusion, disproportionate FMR assessed by regurgitant fraction and RV dysfunction assessed by TAPSE may help the selection of HF patients candidates for MitraClip therapy.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento , Remodelação Ventricular
3.
Int J Artif Organs ; 40(11): 629-635, 2017 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-28777390

RESUMO

BACKGROUND: Continuous flow left ventricular assistance devices (CF-LVADs) have revolutionized the treatment of advanced heart failure. Pump replacement for thrombosis is a high-risk procedure with a high perioperative mortality rate with possible recurrence. We aim to summarize our experience using a conservative approach with medical therapy. METHODS: We retrospectively reviewed records of patients who experienced pump thrombosis after LVAD implantation with HeartWare HVAD at our institution, from November 2010 to March 2016. Device thrombosis (DT) was divided into suspected (SDT) and confirmed (CDT). A conservative approach using thrombolysis and heparin was used in all patients. RESULTS: A total of 32 HeartWare HVAD pumps were implanted. Mean age was 59 ± 10 years and the mean time on mechanical support was 19.29 months (±14.06). Pump thrombosis occurred in 7 patients (0.14 patients/year) after a mean time of 733 (231-1,606) days after LVAD implantation. Three out of 7 cases had thrombosis recurrence (43%). Overall 19 episodes were recorded (0.38 event per patient/year). Eighteen out of 19 thrombolytic treatments were successful (94.7%). No patient required LVAD replacement or transfusion of blood products. There was no significant difference in terms of survival between patients who experienced thrombotic events and patients who did not. No major complications related to thrombolysis were recorded. CONCLUSIONS: Systemic thrombolysis plus heparin was an excellent therapeutic option. Early intervention in clinically stable patients without signs of heart failure but with indirect signs of device thrombosis has led to better outcomes.


Assuntos
Trombose Coronária/tratamento farmacológico , Fibrinolíticos/uso terapêutico , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Heparina/uso terapêutico , Adulto , Idoso , Transfusão de Sangue , Trombose Coronária/diagnóstico , Trombose Coronária/etiologia , Esquema de Medicação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
4.
Tex Heart Inst J ; 38(1): 42-9, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21423467

RESUMO

Urgent repair (within 48 hr after diagnosis) of posterior ventricular septal defect in the presence of cardiogenic shock, consequent to acute myocardial infarction, is associated with a very high mortality rate. The use of left ventricular mechanical support devices has the potential to impart hemodynamic stability and to delay surgical treatment until such time as scar tissue forms around the defect, sufficient to hold a suture patch.From May 2004 through July 2007, 5 patients who were in cardiogenic shock as a consequence of acute posterior ventricular septal defect underwent early implantation of a transfemoral microaxial Impella® Recover® LP 5.0 Support System as mechanical support (bridge to surgery).The mean duration of support by the left ventricular assist device was 14.4 ± 6 days. No one died during assistance. The device reduced left-to-right shunting, systolic pulmonary artery pressure, central venous pressure, and pulmonary capillary wedge pressure. Liver, kidney, and lung function improved, and the 30-day mortality rate was 40%.Although this is a retrospective study of a very small patient population, without benefit of a control group, it is the first report of its kind. This initial experience using the Impella Recover 5.0 in cases of cardiogenic shock due to posterior ventricular septal defect suggests that this conservative approach is a feasible and safe way to improve hemodynamic conditions and delay surgery. Further clinical experience is needed to confirm these early results.


Assuntos
Coração Auxiliar , Choque Cardiogênico/terapia , Ruptura do Septo Ventricular/terapia , Idoso , Feminino , Coração Auxiliar/efeitos adversos , Hemodinâmica , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade , Choque Cardiogênico/fisiopatologia , Choque Cardiogênico/cirurgia , Fatores de Tempo , Resultado do Tratamento , Ruptura do Septo Ventricular/complicações , Ruptura do Septo Ventricular/mortalidade , Ruptura do Septo Ventricular/fisiopatologia , Ruptura do Septo Ventricular/cirurgia