Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 13(2)2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38256494

RESUMO

BACKGROUND: This study aimed to evaluate the survival rate and medium-term outcomes of patients after cemented posterior-stabilized (PS) mobile-bearing (MB) total knee arthroplasty (TKA) using a telemedicine platform during the COVID-19 pandemic in Italy. METHODS: A total of 100 consecutive patients (mean age 73.5 ± 13.2 years) who received a cemented PS MB TKA were enrolled. The mean age of patients who did not complete the telemedicine follow-up (58%) was 75.8 ± 9.7 years. A dedicated software that makes it possible to perform video calls, online questionnaires, and acquire X-rays remotely was used. Subjective clinical scores and objective range-of-motion (ROM) measurements were observed at an average follow-up of 54 ± 11.3 months. RESULTS: A total of 42 of 100 enrolled patients (mean age 70.3 ± 8.4 years) completed the telemedicine follow-up. The mean age of patients who did not complete the telemedicine follow-up (58%) was 75.8 ± 9.7 years. Age was found to be a statistically significant difference between the group that completed the telemedicine follow-up and the one that did not (p < 0.004). KOOS scores improved from 56.1 ± 11.3 to 77.4 ± 16.2, VAS scores decreased from 7.2 ± 2.1 to 2.8 ± 1.6, KSSf scores increased from 47.2 ± 13.3 to 77.1 ± 21.1, FJS scores improved from 43.4 ± 12.3 to 76.9 ± 22.9, and OKS scores increased from 31.9 ± 8.8 to 40.4 ± 9.9. All the differences were statistically significant (p < 0.05). The mean flexion improved from 88° ± 8° to 120° ± 12°. A radiographic evaluation showed a mean pre-operative mechanical axis deviation of 5.3 ± 8.0 degrees in varus, which improved to 0.4 ± 3.4 degrees of valgus post-operation. The survivorship at 5 years was 99%. CONCLUSIONS: Subject to small numbers, telemedicine presented as a useful instrument for performing remote monitoring after TKA. The most important factor in telemedicine success remains the patient's skill, which is usually age-related, as older patients have much more difficulty in approaching a technological tool.

2.
Knee Surg Sports Traumatol Arthrosc ; 31(7): 2688-2699, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37004531

RESUMO

PURPOSE: This study aimed to compare the long-term outcomes of arthroscopic versus mini-open repair in patients with isolated subscapularis tendon tears. METHODS: Google Scholar, PubMed, and Embase databases were searched for studies evaluating isolated subscapularis tears subsequently treated by arthroscopic or mini-open repair. The inclusion criteria were clinical studies reporting isolated subscapularis lesions treated by arthroscopic or mini-open repair, a minimum follow-up of 12 months, and clinical and functional outcomes reported in the study results. Articles not reporting functional outcomes or studies that reported results for anterosuperior rotator cuff tears without a separate analysis of subscapularis tendon tears were excluded. Studies older than 20 years and studies with a minimum follow-up of less than 12 months were also excluded. RESULTS: A total of 12 studies met the inclusion criteria; 8 papers were included in the arthroscopic repair group, and 6 were included in the mini-open repair group (2 studies reported results for both techniques). The mean age reported was 49.3 years, and 85.1% of patients were male. The dominant limb was involved in 77.6% of the patients, and a traumatic onset of symptoms was verified in 76.3%. The mean time to surgery was 9.6 months. The Constant-Murley score showed positive results for the arthroscopic and mini-open groups, with mean postoperative values of 84.6 and 82.1, respectively. Promising results were also observed for pain, with a mean of 13.2 (out of 15) points for the arthroscopic group and 11.7 for the mini-open group. The long head of the biceps was involved in 78% of the patients, and LHB tenodesis or tenotomy were the most common concomitant procedures performed. CONCLUSIONS: There was no significant difference in clinical and functional outcomes between open and arthroscopic repair. Moreover, the same complication rates were reported in both treatments, but arthroscopic repair led to less postoperative pain. LEVEL OF EVIDENCE: IV.


Assuntos
Lesões do Manguito Rotador , Traumatismos dos Tendões , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Manguito Rotador/cirurgia , Artroscopia/métodos , Lesões do Manguito Rotador/cirurgia , Traumatismos dos Tendões/cirurgia , Dor Pós-Operatória , Resultado do Tratamento
3.
Int Orthop ; 47(1): 83-87, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36102981

RESUMO

PURPOSE: The purpose is to verify the intra- and inter-operator reliability of an extramedullary (EM) accelerometer-based smart cutting guide for distal femoral resection during primary total knee arthroplasty (TKA). The hypothesis of the present study was that the use of the device would result in a good correlation between different operators with a difference between repeated measurements of less than 1°. METHODS: Twenty-five not consecutive patients with knee osteoarthritis undergone to primary TKA using an EM inertial-based cutting guide to perform distal femoral resection. In order to assess the agreement in femoral axis definition of the device, two operators performed three time each the manoeuvres necessary to define axis. Inter-rater agreement was evaluated with Bland and Altman agreement test. Intra-rater repeatability was evaluated analysing average results distribution of repeated measurements. Accuracy of the device was evaluated comparing differences between intra-operative device data with final implant alignment measured on post-operative longstanding x-rays using Students' t test. RESULTS: Agreement between the two operators was statistically significant (p < 0.05) with a bias of - 0.4° (95% CI - 0.6° to - 0.2°). Average difference between cut orientation measured with device and final implant position, measured on x-rays, was 0.2° (95% CI - 1.5° to 1.7°) with no statistical difference between the two measurements. Final implant alignment, measured on x-ray, was 90.2°, with 95% of cases distributed within range 88.0° to 92.0° for varus-valgus and 2.8° and with 95% of cases distributed within range 2.0° to 4.0° for flexion-extension. CONCLUSIONS: The EM accelerometer-based smart cutting guide used to perform distal femoral resection during primary TKA demonstrated a good intra- and inter-operator reliability in the present in vivo study.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Reprodutibilidade dos Testes , Fêmur/cirurgia , Osteoartrite do Joelho/cirurgia , Acelerometria , Articulação do Joelho/cirurgia
4.
J Clin Med ; 11(21)2022 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-36362808

RESUMO

BACKGROUND: "Windswept" deformity (WSD) consists of a non-frequent condition in which the patient presents a valgus deformity in one knee and a varus deformity in the other. We performed a review of the available literature to aggregate the accessible data on the outcomes of bilateral knee arthroplasty in patients with WSD and to discuss the surgical challenges that this condition might pose. METHODS: A systematic review of the literature following the PRISMA guidelines was conducted. The relevant studies between 1979 and 2021 were identified. Four studies with a total of 68 patients were included for analysis. The mean follow-up for varus knees was 3.3 years, 3.1 years for valgus knees. The quality and rigor of the included studies was assessed using the Methodological index for non-randomized studies (MINORS). RESULTS: All the studies reported improvement in knee function following knee replacement surgery, and a reduction in axial deviation of both knees, with similar results in valgus and varus knees in terms of patient satisfaction. The most relevant data were that unicompartmental knee arthroplasty (UKA) allowed for limited axial correction with slightly inferior functional results. Kinematic alignment (KA) allowed for similar results in both knees. CONCLUSION: The present review shows how satisfactory results can be achieved in both knees in patients with WSD and osteoarthrosis (OA). However, the operating surgeon should be aware of the importance of the implant choice in terms of functional outcomes. In the absence of extra-articular deformities, calipered KA total knee arthroplasty (TKA) can be performed on both knees with good axial correction and functional outcome. LEVEL OF EVIDENCE: II -Systematic review of cohort studies.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA