Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 12(4)2023 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-36835785

RESUMO

(1) The use of high-flow nasal cannula (HFNC) combined with frequent respiratory monitoring in patients with acute hypoxic respiratory failure due to COVID-19 has been shown to reduce intubation and mechanical ventilation. (2) This prospective, single-center, observational study included consecutive adult patients with COVID-19 pneumonia treated with a high-flow nasal cannula. Hemodynamic parameters, respiratory rate, inspiratory fraction of oxygen (FiO2), saturation of oxygen (SpO2), and the ratio of oxygen saturation to respiratory rate (ROX) were recorded prior to treatment initiation and every 2 h for 24 h. A 6-month follow-up questionnaire was also conducted. (3) Over the study period, 153 of 187 patients were eligible for HFNC. Of these patients, 80% required intubation and 37% of the intubated patients died in hospital. Male sex (OR = 4.65; 95% CI [1.28; 20.6], p = 0.03) and higher BMI (OR = 2.63; 95% CI [1.14; 6.76], p = 0.03) were associated with an increased risk for new limitations at 6-months after hospital discharge. (4) 20% of patients who received HFNC did not require intubation and were discharged alive from the hospital. Male sex and higher BMI were associated with poor long-term functional outcomes.

4.
Respir Care ; 66(5): 758-768, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33298622

RESUMO

BACKGROUND: Dual-patient, single-ventilator protocols (ie, protocols to ventilate 2 patients with a single conventional ventilator) may be required in times of crisis. This study demonstrates a means to titrate peak inspiratory pressure (PIP), PEEP, and [Formula: see text] for test lungs ventilated via a dual-patient, single-ventilator circuit. METHODS: This prospective observational study was conducted using a ventilator connected to 2 test lungs. Changes in PIP, PEEP, and [Formula: see text] were made to the experimental lung, while no changes were made to the control lung. Measurements were obtained simultaneously from each test lung. PIP was titrated using 3D-printed resistors added to the inspiratory circuit. PEEP was titrated using expiratory circuit tubing with an attached manual PEEP valve. [Formula: see text] was titrated by using a splitter added to the ventilator tubing. RESULTS: PIP, PEEP, and [Formula: see text] were reliably and incrementally titratable in the experimental lung, with some notable but manageable changes in pressure and [Formula: see text] documented in the control lung during these titrations. Similar results were measured in lungs with identical and different compliances. CONCLUSIONS: Pressures and [Formula: see text] can be reliably adjusted when utilizing a dual-patient, single-ventilator circuit with simple, low-cost modifications to the circuit. This innovation could potentially be lifesaving in a resource-limited or crisis setting. Understanding the interactions of these circuits is imperative for making their use safer.


Assuntos
Respiração com Pressão Positiva , Ventiladores Mecânicos , Humanos , Pulmão , Respiração , Respiração Artificial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA