Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 411(16): 3533-3542, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31025182

RESUMO

Choosing an appropriate ion source is a crucial step in liquid chromatography mass spectrometry (LC/MS) method development. In this paper, we compare four ion sources for LC/MS analysis of 40 pesticides in tomato and garlic matrices. We compare electrospray ionisation (ESI) source, thermally focused/heated electrospray (HESI), atmospheric pressure photoionisation (APPI) source with and without dopant, and multimode source in ESI mode, atmospheric pressure chemical ionisation (APCI) mode, and combined mode using both ESI and APCI, i.e. altogether seven different ionisation modes. The lowest limits of detection (LoDs) were obtained by ESI and HESI. Widest linear ranges were observed with the conventional ESI source without heated nebuliser gas. In comparison to HESI, ESI source was significantly less affected by matrix effect. APPI ranked second (after ESI) by not being influenced by matrix effect; therefore, it would be a good alternative to ESI if low LoDs are not required. Graphical abstract.

2.
J Am Soc Mass Spectrom ; 28(3): 461-469, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27966175

RESUMO

Electrospray ionization efficiency is known to be affected by mobile phase composition. In this paper, a detailed study of analyte ionization efficiency dependence on mobile phase pH is presented. The pH effect was studied on 28 compounds with different chemical properties. Neither pK a nor solution phase ionization degree by itself was observed to be sufficient at describing how aqueous phase pH affects the ionization efficiency of the analyte. Therefore, the analyte behavior was related to various physicochemical properties via linear discriminant analyses. Distinction between pH-dependent and pH-independent compounds was achieved using two parameters: number of potential charge centers and hydrogen bonding acceptor capacity (in the case of 80% acetonitrile) or polarity of neutral form of analyte and pK a (in the case of 20% acetonitrile). It was also observed that decreasing pH may increase ionization efficiency of a compound by more than two orders of magnitude. Graphical Abstract ᅟ.

3.
J Environ Sci Health B ; 51(7): 455-64, 2016 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-27050772

RESUMO

The aim of the study was to provide a comprehensive overview of neonicotinoid pesticide residues in honey samples for a single country and compare the results with the import data for neonicotinoid pesticides. The levels of four neonicotinoid pesticides, namely thiamethoxam, imidacloprid, acetamiprid, and thiacloprid, were determined in 294 honey samples harvested from 2005 to 2013 from more than 200 locations in Estonia. For the analyzed honey samples, 27% contained thiacloprid, and its levels in all cases were below the maximum residue level set by the European Union. The other neonicotinoids were not detected. The proportion of thiacloprid-positive samples for different years correlates well with the data on thiacloprid imports into Estonia, indicating that honey contamination with neonicotinoids can be estimated based on the import data.


Assuntos
Mel/análise , Inseticidas/análise , Resíduos de Praguicidas/análise , Cromatografia Líquida/métodos , Estônia , Imidazóis/análise , Neonicotinoides , Nitrocompostos/análise , Oxazinas/análise , Piridinas/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Tiametoxam , Tiazinas/análise , Tiazóis/análise
4.
J Am Soc Mass Spectrom ; 26(11): 1923-30, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26246121

RESUMO

For the first time, quantitative electrospray (ESI) ionization efficiencies (IE), expressed as logIE values, obtained on different mass-spectrometric setups (four mass analyzers and four ESI sources) are compared for 15 compounds of diverse properties. The general trends of change of IE with molecular structure are the same with all experimental setups. The obtained IE scales could be applied on different setups: there were no statistically significant changes in the order of ionization efficiency and the root mean of squared differences of the logIE values of compounds between the scales compiled on different instruments were found to be between 0.21 and 0.55 log units. The results show that orthogonal ESI source geometry gives better differentiating power and additional pneumatic assistance improves it even more. It is also shown that the ionization efficiency values are transferable between different mass-spectrometric setups by three anchoring points and a linear model. The root mean square error of logIE prediction ranged from 0.24 to 0.72 depending on the instrument. This work demonstrates for the first time the inter-instrument transferability of quantitative electrospray ionization efficiency data. Graphical Abstract ᅟ.

5.
J Sep Sci ; 36(15): 2458-63, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23712960

RESUMO

Two different methods to reinforce the poly(glycidyl methacrylate-co-ethylene dimethacrylate) HPLC monolithic columns of 3 mm id in a glass column reservoir were studied: composite columns with polymeric particles in the monolith and surface treatment of the reservoir wall. Of the two methods used to counter the mechanical instability and formation of flow channels (composite columns and column wall surface treatment), we demonstrated that proper column wall surface treatment was sufficient to solve both problems. Our study also indicated that no surface treatment is efficient, and of the methods studied silanization in acidified ethanol solution and constant renewal of the reaction mixture (dynamic mode) proved to be the most effective. As a result of this study, we have been able to prepare repeatable and durable methacrylate HPLC columns with good efficiencies.


Assuntos
Metilmetacrilatos/química , Cromatografia Líquida de Alta Pressão/instrumentação , Metilmetacrilatos/síntese química , Polimerização , Polímeros/química
6.
J Am Soc Mass Spectrom ; 23(12): 2051-4, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23001970

RESUMO

A novel electrospray nebulizer has been designed, which includes an additional nebulization gas capillary inside the liquid capillary. This design offers significantly enhanced ionization efficiency compared with the classic nebulizer design and leads to improved sensitivity (by three to 10 times) and decreases the detection limit, on an average 10 times. We see these results as the first step in the design of ESI nebulizers offering improved sensitivity and higher robustness. Possible future developments would include optimization of the dimensions of the capillaries as well as testing the nebulizer for other matrices and analytes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA