Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
Bone Joint J ; 101-B(7_Supple_C): 33-39, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31256647

RESUMO

AIMS: There is insufficient evidence to recommend the use of alternative polyethylene bearings in modular, fixed-bearing total knee arthroplasty (TKA). The purpose of this study was to compare standard polyethylene (SP) and highly crosslinked polyethylene (XLP) tibial liners in posterior-stabilized TKA, with osteolysis as the primary outcome and clinical results and the rate of re-operation as the secondary outcomes. PATIENTS AND METHODS: This is a single-surgeon, prospective randomized study involving one design of modular posterior-stabilized TKA. An analysis of 122 TKAs with an SP compression moulded liner and 123 with an XLP liner was performed, with a mean follow-up of six years (2 to 11). Patients were evaluated clinically using the Knee Society score, Lower Extremity Activity Score (LEAS), and the presence of an effusion, and standard radiographs were assessed for radiolucent lines and osteolytic lesions. RESULTS: Osteolysis was present in four TKAs (3.3%) in the SP group, and no knees in the XLP group (p = 0.06). There were no significant differences between the Knee Society total score, change in total score, knee function score, change in function score, LEAS, and change in LEAS in the two groups. There was a significant difference in the presence of an effusion (10/122 with SP liners, 1/123 with XLP liners; p = 0.02). There was no significant difference in the rate of re-operation between the two groups (p = 0.36). There were no complications related to the XLP liner. CONCLUSION: At this length of follow-up, there were no advantages and no complications related to the use of this XLP tibial liner. The presence of effusion and small osteolytic lesions was more frequent with SP than XLP liners, but of unknown clinical significance. Cite this article: Bone Joint J 2019;101-B(7 Supple C):33-39.


Assuntos
Artroplastia do Joelho/métodos , Reagentes de Ligações Cruzadas , Previsões , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Polietileno , Tíbia/cirurgia , Idoso , Fenômenos Biomecânicos , Feminino , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiopatologia , Masculino , Osteoartrite do Joelho/diagnóstico , Osteoartrite do Joelho/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Radiografia , Fatores de Risco , Resultado do Tratamento
2.
Bone Joint J ; 101-B(6_Supple_B): 37-44, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31146559

RESUMO

AIMS: Patients may present with concurrent symptomatic osteoarthritis (OA) of the hip and degenerative disorders of the lumbar spine, with surgical treatment being indicated for both. Whether arthroplasty of the hip or spinal surgery should be performed first remains uncertain. MATERIALS AND METHODS: Clinical scenarios were devised for a survey asking the preferred order of surgery and the rationale for this decision for five fictional patients with both OA of the hip and degenerative lumbar disorders. These were symptomatic OA of the hip and: 1) lumbar spinal stenosis with neurological claudication; 2) lumbar degenerative spondylolisthesis with leg pain; 3) lumbar disc herniation with leg weakness; 4) lumbar scoliosis with back pain; and 5) thoracolumbar disc herniation with myelopathy. This survey was sent to 110 members of The Hip Society and 101 members of the Scoliosis Research Society. The choices of the surgeons were compared among scenarios and between surgical specialties using the chi-squared test. The free-text comments were analyzed using text-mining. RESULTS: Responses were received from 51 hip surgeons (46%) and 37 spine surgeons (37%). The percentages of hip surgeons recommending 'hip first' differed significantly among scenarios: 59% for scenario 1; 73% for scenario 2; 47% for scenario 3; 47% for scenario 4; and 10% for scenario 5 (p < 0.001). The percentages of spine surgeons recommending 'hip first' were 49% for scenario 1; 70% for scenario 2; 19% for scenario 3; 78% for scenario 4; and 0% for scenario 5. There were significant differences between the groups for scenarios 3 (more hip surgeons recommended 'hip first'; p = 0.012) and 4 (more hip surgeons recommended 'spine first'; p = 0.006). CONCLUSION: In patients with coexistent OA of the hip and degenerative disorders of the spine, the question of 'hip or spinal surgery first' elicits relatively consistent answers in some clinical scenarios, but remains controversial in others, even for experienced surgeons. The nature of neurological symptoms can influence surgeons' decision-making. Cite this article: Bone Joint J 2019;101-B(6 Supple B):37-44.


Assuntos
Vértebras Lombares/cirurgia , Osteoartrite do Quadril/cirurgia , Doenças da Coluna Vertebral/cirurgia , Competência Clínica/normas , Tomada de Decisão Clínica , Humanos , Cirurgiões Ortopédicos/normas , Cirurgiões Ortopédicos/estatística & dados numéricos , Osteoartrite do Quadril/complicações , Padrões de Prática Médica/estatística & dados numéricos , Características de Residência , Doenças da Coluna Vertebral/complicações , Estados Unidos
3.
Bone Joint J ; 100-B(7): 898-902, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29954198

RESUMO

Aims: To report our experience with trunnion corrosion following metal-on-polyethylene total hip arthroplasty, in particular to report the spectrum of presentation and determine the mean time to presentation. Patients and Methods: We report the presenting symptoms and signs, intraoperative findings, and early results and complications of operative treatment in nine patients with a mean age of 74 years (60 to 86). The onset of symptoms was at a mean of seven years (3 to 18) after index surgery. Results: Patients presented with a variety of symptoms including pain, limp and rash. The preoperative mean serum cobalt level was 7.1 ppb (2.2 to 12.8) and mean serum chromium level was 2.2 ppb (0.5 to 5.2). Metal artifact reduction sequence (MARS) MRI showed fluid collection and possible pseudotumour formation in five hips, fluid collection in two hips, and synovitis/debris in one hip, with no MRI in one patient. Acetabular revision was performed in three patients, six patients underwent liner and head exchange only. The postoperative metal levels decreased in all patients: mean cobalt 0.5 ppb (0 to 1.8) and mean chromium 0.9 ppb (0 to 2.6) at a mean of five months (3 to 8) postoperatively. Seven patients had good pain relief and no complications at one year. There were two major complications requiring reoperation: acute infection at six weeks, for which the patient required two-stage reimplantation; and recurrent dislocation, for which the patient was revised to a dual mobility component. Conclusion: Trunnion corrosion in metal-on-polyethylene THA has a range of presenting symptoms, and may present later than previously described. A high index of suspicion is warranted, and serum cobalt and chromium levels are recommended for diagnosis. Patients should be counselled about possible postoperative complications. Cite this article: Bone Joint J 2018;100-B:898-902.


Assuntos
Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Falha de Prótese/etiologia , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Corrosão , Feminino , Articulação do Quadril/cirurgia , Humanos , Imageamento por Ressonância Magnética , Masculino , Metais/efeitos adversos , Pessoa de Meia-Idade , Polietileno/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Desenho de Prótese/efeitos adversos , Estudos Retrospectivos
4.
Bone Joint J ; 98-B(1 Suppl A): 64-7, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26733644

RESUMO

The 'jumbo' acetabular component is now commonly used in acetabular revision surgery where there is extensive bone loss. It offers high surface contact, permits weight bearing over a large area of the pelvis, the need for bone grafting is reduced and it is usually possible to restore centre of rotation of the hip. Disadvantages of its use include a technique in which bone structure may not be restored, a risk of excessive posterior bone loss during reaming, an obligation to employ screw fixation, limited bone ingrowth with late failure and high hip centre, leading to increased risk of dislocation. Contraindications include unaddressed pelvic dissociation, inability to implant the component with a rim fit, and an inability to achieve screw fixation. Use in acetabulae with < 50% bone stock has also been questioned. Published results have been encouraging in the first decade, with late failures predominantly because of polyethylene wear and aseptic loosening. Dislocation is the most common complication of jumbo acetabular revisions, with an incidence of approximately 10%, and often mandates revision. Based on published results, a hemispherical component with an enhanced porous coating, highly cross-linked polyethylene, and a large femoral head appears to represent the optimum tribology for jumbo acetabular revisions.


Assuntos
Acetábulo , Artroplastia de Quadril/métodos , Prótese de Quadril , Desenho de Prótese , Parafusos Ósseos , Humanos , Polietileno , Reoperação
5.
Bone Joint J ; 96-B(11 Supple A): 118-21, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25381423

RESUMO

Metaphyseal bone loss is common with revision total knee replacement (RTKR). Using the Anderson Orthopaedic Research Institute (AORI) classification, type 2-B and type 3 defects usually require large metal blocks, bulk structural allograft or highly porous metal cones. Tibial and femoral trabecular metal metaphyseal cones are a unique solution for large bone defects. These cones substitute for bone loss, improve metaphyseal fixation, help correct malalignment, restore the joint line and may permit use of a shorter stem. The technique for insertion involves sculpturing of the remaining bone with a high speed burr and rasp, followed by press-fit of the cone into the metaphysis. The fixation and osteoconductive properties of the porous cone outer surface allow ingrowth and encourage long-term biological fixation. The revision knee component is then cemented into the porous cone inner surface, which provides superior fixation compared with cementing into native but deficient metaphyseal bone. The advantages of the cone compared with allograft include: technical ease, biological fixation, no resorption, and possibly a lower risk of infection. The disadvantages include: difficult extraction and relatively short-term follow-up. Several studies using cones report promising short-term results for the reconstruction of large bone defects in RTKR.


Assuntos
Artroplastia do Joelho/métodos , Reabsorção Óssea/cirurgia , Articulação do Joelho/cirurgia , Prótese do Joelho , Humanos , Articulação do Joelho/fisiopatologia , Desenho de Prótese , Falha de Prótese , Amplitude de Movimento Articular
6.
J Bone Joint Surg Br ; 94(2): 145-51, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22323676

RESUMO

Persistent groin pain after seemingly successful total hip replacement (THR) appears to have become more common. Recent studies have indicated a high incidence after metal-on-polyethylene and metal-on-metal conventional THR and it has been documented in up to 18% of patients after metal-on-metal resurfacing. There are many causes, including acetabular loosening, stress fracture, and iliopsoas tendonitis and impingement. The evaluation of this problem requires a careful history and examination, plain radiographs and an algorithmic approach to special diagnostic imaging and tests. Non-operative treatment is not usually successful. Specific operative treatment depending on the cause of the pain usually involves revision of the acetabular component, iliopsoas tenotomy or other procedures, and is usually successful. Here, an appropriate algorithm is described.


Assuntos
Artroplastia de Quadril/efeitos adversos , Virilha , Dor Pós-Operatória/etiologia , Algoritmos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Humanos , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/epidemiologia , Dor Pós-Operatória/terapia , Prevalência , Falha de Prótese , Infecções Relacionadas à Prótese/complicações , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/terapia , Reoperação
8.
J Bone Joint Surg Br ; 86(8): 1137-41, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15568526

RESUMO

The optimal characteristics of pneumatic compression for mechanical prophylaxis of thromboembolism after total knee arthroplasty (TKA) are not known. Our study compared two methods of calf compression, with the hypothesis that the device which provided a larger increase in peak venous velocity would produce a lower rate of thromboembolism. We performed a prospective, randomised study on 423 patients (472 knees). Duplex ultrasonography was carried out by experienced technicians who were blinded to the device used. Overall, 206 patients (232 knees) used a rapid inflation, asymmetrical compression (RIAC) device and 217 (240 knees) a sequential circumferential compression device (SCD). The rate of venous thromboembolism was 6.9% with the RIAC device compared with 15% for the SCD device (p = 0.007). The incidence of thrombi with unilateral primary TKA was 8.4% for the RIAC compared with 16.8% for the SCD device (p = 0.03). In 47 patients with a bilateral TKA, the incidence of thrombi was 4% for the RIAC compared with 22.7% for the SCD device (p = 0.05 per knee). There was a low rate of mortality and pulmonary embolism when using mechanical prophylaxis for thromboembolism after TKA. Our findings show that the use of rapid inflation, asymmetrical calf compression gave a significantly lower rate of thromboembolism.


Assuntos
Artroplastia do Joelho/instrumentação , Bandagens , Tromboembolia/prevenção & controle , Trombose Venosa/prevenção & controle , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
9.
Clin Orthop Relat Res ; (392): 94-100, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11716430

RESUMO

In many designs of total knee arthroplasty, the patella with one central peg has been replaced by a patella with three small pegs for cement fixation. There have been recent reports of failure of this design. This is a prospective, consecutive study of two types of patella component fixation in 228 posterior-stabilized knee arthroplasties done by one surgeon. A central peg all-polyethylene component was used for 84 consecutive knees in 63 patients (Group A) and a three-peg patella was used for the next 144 consecutive knees in 99 patients (Group B). The mean followup was 6.7 years (range, 2-10 years) for Group A and 3.5 years (range, 2-6 years) for Group B. Except for the patellar component fixation, all knees had the same posterior-stabilized prosthesis using a specific protocol for patellar resurfacing. No patient required reoperation for a patellofemoral complication. The prevalence of patella fracture was higher in Group A, 4.7% (four knees), compared with 2.1% (three knees) in Group B, but this difference was not statistically significant. The presence of anterior knee pain referable to the patella was 7.1% (five patients, six knees) in Group A (one patient with two knees had severe anterior knee pain) and 9% (13 knees in 13 patients) in Group B. There was no patella clunk syndrome, subluxation, or fracture of a fixation peg in either group. With this specific protocol for patella resurfacing, there was a higher rate of complications with the one central peg patella (4.7%) than with the three-peg patella (2.1%), but this did not reach statistical significance. The results do not support an increased risk of component failure with this three-peg patella design, but do not, at this length of followup, show any significant advantage of three-peg fixation.


Assuntos
Artroplastia do Joelho/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Cimentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Falha de Prótese
10.
J Bone Joint Surg Am ; 83(10): 1490-4, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11679598

RESUMO

BACKGROUND: Younger patients are having total hip arthroplasty now, and a woman who has had such a procedure may want to become pregnant. The purposes of this study were to report on a series of women who had completed a pregnancy after a total hip arthroplasty and to determine if pregnancy affects the function and longevity of the prosthesis. METHODS: Five women, with a total of seven uncemented total hip replacements, had six successful pregnancies. The mean age at the arthroplasty was twenty-nine years (range, twenty-two to thirty-eight years), and the mean time from the hip arthroplasty to the pregnancy was 2.5 years (range, one to seven years). These patients (Group A) were compared with a matched group of five women with a total of eight uncemented total hip prostheses (Group B) who had not completed a pregnancy. The mean follow-up time was eight years (range, two to thirteen years) for Group A and seven years (range, two to twelve years) for Group B. Patients were clinically evaluated with the Harris hip score. Radiographs were evaluated for component fixation and osteolysis. RESULTS: The five women completed a total of six successful pregnancies. One patient, with a bilateral total hip arthroplasty, had two successful pregnancies, 2.5 years apart. Three children were delivered vaginally (with the mother in the lithotomy position) and three, by cesarean section. There were no complications related to the total hip arthroplasty after delivery. The mean weight gain during the pregnancy was 13 kg (range, 8 to 14.2 kg). In Group A, the mean Harris hip score was 94 points prior to the pregnancy and 97 points at the time of the most recent follow-up. In group B, the mean Harris hip score was 91 points at one to two years after the arthroplasty and it was unchanged at the time of the most recent follow-up. There were six excellent results and one good result of the hip arthroplasty in Group A and five excellent and three good results in Group B. The mean total arc of hip motion was 217 degrees in Group A before the pregnancy and 241 degrees at the time of the most recent follow-up. The mean total arc of hip motion was 193 degrees in Group B at one to two years postoperatively and 190 degrees at the time of the most recent follow-up. The difference in the total arc of hip motion between the two groups at the latest follow-up evaluation was significant (p = 0.025). There were no reoperations in either group. Radiographs showed osteolysis of the femur in three hips in Group A and three hips in Group B. CONCLUSIONS: It appears that successful pregnancy and normal vaginal delivery can occur safely after total hip arthroplasty. The overall result, function, and radiographic appearance after the total hip arthroplasty was not adversely affected by pregnancy in this small group of patients.


Assuntos
Prótese de Quadril , Resultado da Gravidez , Adulto , Feminino , Articulação do Quadril/diagnóstico por imagem , Humanos , Gravidez , Complicações na Gravidez/epidemiologia , Radiografia
11.
J Arthroplasty ; 16(5): 628-34, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11503123

RESUMO

This is a prospective, consecutive study of 98 total hip arthroplasties implanted by 1 surgeon in 66 patients with rheumatoid arthritis. The mean follow-up time was 7.4 years (range, 2-13 years). All 98 acetabular components were uncemented titanium fiber metal-coated components fixed with multiple screws. Sixty-five hips had bulk or cancellous allograft for protrusio acetabuli. Following a prospective protocol based on patient age, 51 hips had an uncemented femoral component, and 47 hips had a cemented femoral component. Using the Harris Hip Score, 30 hips were rated as excellent; 44, good; 15, fair; and 9, poor. There were no early deep infections. One hybrid hip was removed for late metastatic infection at 7 years. Radiographic evaluation of 98 acetabular components showed 1 case of septic loosening, 2 cases of aseptic loosening (1 patient asymptomatic), and 1 case with severe wear and ischial osteolysis. None of the 47 cemented femoral components subsided, and osteolysis was seen in only 3 femora (7%). Of the 51 uncemented femoral components, subsidence occurred in 7 hips (14%), and osteolysis occurred in 15 hips (30%). Uncemented acetabular components have a high rate of success in patients with rheumatoid arthritis who have a total hip arthroplasty. There is a high rate of subsidence and osteolysis, however, with first-generation cementless femoral components.


Assuntos
Artrite Reumatoide/cirurgia , Artroplastia de Quadril/métodos , Prótese de Quadril , Acetábulo , Adulto , Idoso , Artrite Reumatoide/diagnóstico por imagem , Avaliação da Deficiência , Feminino , Fêmur , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Falha de Prótese , Radiografia , Reoperação , Resultado do Tratamento
12.
J South Orthop Assoc ; 10(3): 155-63; discussion 163, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-12132827

RESUMO

This is a study of two consecutive antithromboembolism regimens after total knee arthroplasty. In group 1, 131 patients were given aspirin prophylaxis alone (650 mg by mouth twice a day). In group 2, 123 patients were treated with aspirin, knee-high compression stockings, and intermittent knee-high pneumatic compression devices, which were started intraoperatively. The prevalence of deep vein thrombosis in group 1 was 15.9% (21 of 131 patients). One patient had a possible symptomatic nonfatal pulmonary embolism, and one patient had a symptomatic calf thrombus. Asymptomatic thrombi were detected in calf veins in 9 patients, popliteal vein in 6 patients, and femoral vein in 5 patients. In Group 2, the prevalence was 7.4% (9 of 123 patients). Asymptomatic thrombi were located in calf veins in 6 patients, popliteal vein in 1 patient, and femoral vein in 2 patients. There was a significant difference in the prevalence of deep vein thrombosis between the two groups. A history of previous thromboembolism was a significant risk factor for a new thrombus. The prevalence after bilateral one-stage knee arthroplasty was 24.3% for group 1 and 12.5% for group 2. Aspirin and knee-high intermittent pneumatic compression together are more effective than aspirin alone for prevention of deep vein thrombosis after primary and revision knee arthroplasty.


Assuntos
Anti-Inflamatórios não Esteroides/uso terapêutico , Artroplastia do Joelho , Aspirina/uso terapêutico , Bandagens , Complicações Pós-Operatórias/prevenção & controle , Tromboembolia/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pressão , Estudos Prospectivos
13.
Clin Orthop Relat Res ; (380): 144-50, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11064984

RESUMO

The usefulness of continuous passive motion after total knee arthroplasty remains controversial. The reported benefits include decreased rates of knee manipulation, deep vein thrombosis, and postoperative use of analgesics, and a greater range of motion. Other studies have reported increased wound complications, bleeding, and pain. Lack of consensus on the use of continuous passive motion exists because reported studies include many confounding variables. Several studies have shown that continuous passive motion in the hospital decreased the rate of knee manipulation from as high as 21% to as low as 0%. Although many studies show that range of motion may improve more rapidly with continuous passive motion, the ultimate range of motion at followup is unchanged. At the author's institution, continuous passive motion is used three times per day (1 hour sessions), beginning on the first postoperative day, within a 4 to 5 day inpatient hospital pathway. Of 132 knees that had a primary posterior-stabilized total knee arthroplasty, seven knees (5%) had a manipulation for failure to obtain greater than 70 degrees flexion. No patients had major wound complications that required reoperation. There is no specific charge to the patient for the continuous passive motion because it is included in the hospital per diem charge. The literature and the author's data support the use of continuous passive motion to decrease the rate of manipulation (and its costs) for poor range of motion after total knee arthroplasty. If patients follow fixed inpatient hospital pathways, the length (and possibly cost) of hospital stay is not changed by use of continuous passive motion. The data on the effect of continuous passive motion on overall analgesic use and prevalence of deep vein thrombosis are not clear.


Assuntos
Artroplastia do Joelho/reabilitação , Terapia Passiva Contínua de Movimento , Perda Sanguínea Cirúrgica , Humanos , Tempo de Internação , Manipulação Ortopédica , Dor Pós-Operatória , Amplitude de Movimento Articular , Resultado do Tratamento , Trombose Venosa/prevenção & controle , Cicatrização
14.
J Arthroplasty ; 15(6): 718-29, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11021447

RESUMO

This is a retrospective analysis of 2 methods of fixation of the femoral component in 86 consecutive revision arthroplasties, for which all clinical and radiographic data were recorded prospectively. There were 56 cemented revisions using precoated femoral components followed for 2 to 8 years (mean, 4 years) and 30 uncemented, proximally porous-coated femoral revisions followed for 2 to 6 years (mean, 4 years). Of the 56 cemented hips, 31 (55%) had a good or excellent clinical result. Rerevision has been performed in 10 hips, and revision of 3 loose femoral components is pending (23%). Radiographic review of 56 femoral components showed that 16 (29%) had probable or definite loosening. Of 30 cementless hips, 24 (80%) had a good or excellent clinical result. There was radiographic bone ingrowth in 22 of 30 hips (73%). Seven hips (23%) had nonprogressive subsidence, and 3 hips (10%) had progressive subsidence or loosening. Rerevision has been performed in only 2 hips (7%). The high rate of loosening (29%) and rerevision (23%) at a mean follow-up of only 4 years suggests that a precoated femoral component may place increased stress at the already damaged bone-cement interface.


Assuntos
Artroplastia de Quadril/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Cimentos Ósseos , Feminino , Fêmur , Articulação do Quadril/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Desenho de Prótese , Radiografia , Estudos Retrospectivos
15.
J Arthroplasty ; 15(2): 234-7, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10708093

RESUMO

A 65-year-old woman had a posterior cruciate-retaining cemented Press-Fit Condylar (PFC; Johnson & Johnson Professional, Inc., Raynham, MA) knee replacement with resurfacing of the patella using a cemented all-polyethylene, 3-peg component. Five years postoperatively, the patient developed anterior knee pain. The patella tracked normally, but radiographs showed a shift of the patellar component. At revision, there was shear failure of all 3 fixation pegs and loosening of the component. Revision with a cemented Press-Fit Condylar Sigma patellar 3-peg component (Johnson & Johnson Professional, Inc., Raynham, MA) was performed.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Idoso , Cimentos Ósseos , Feminino , Humanos , Osteoartrite do Joelho/cirurgia , Polietilenos , Desenho de Prótese , Falha de Prótese
16.
Clin Orthop Relat Res ; (364): 153-9, 1999 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10416404

RESUMO

One hundred nineteen consecutive primary hybrid total hip arthroplasties with a precoated femoral component were performed by one surgeon in 100 patients and followed up prospectively. Ninety-eight hips in 82 patients (mean age, 67 years) were evaluated clinically and radiographically at a mean of 6.5 years (range, 5-9 years). The hips were evaluated clinically using the Harris hip score, and radiographs were evaluated for femoral cement grade, loosening, and osteolysis. Ninety-five hips remained in place at the most recent followup. Two femoral components were revised for definite loosening, and one well fixed femoral component was removed because of late hematogenous infection. Excluding the three hips that were revised, the clinical result was excellent or good in 79 hips (83%), fair in 12 hips (13%), and poor in four hips (4%). All other femoral components were well fixed. There were defects of the cement mantles (C1 and C2) in 90 hips. No femoral component had a stem and cement radiolucent line. Focal femoral osteolysis was seen in only two hips. One acetabular component was removed at 5 years because of late hematogenous infection. One acetabular component had asymptomatic migration. The remaining 96 acetabular components were well fixed. Focal acetabular osteolysis was present in four hips. The mean linear polyethylene wear rate was 0.06 (+/- 0.05) mm per year. In contrast to other reports of early failure and osteolysis, the use of a precoated femoral component in this study did not adversely affect the fixation of hybrid total hip arthroplasty, with definite failure of only 2% (two of 98) of the femoral components.


Assuntos
Artroplastia de Quadril/instrumentação , Materiais Revestidos Biocompatíveis/uso terapêutico , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Materiais Revestidos Biocompatíveis/efeitos adversos , Feminino , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/classificação , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/etiologia , Osteólise/etiologia , Falha de Prótese , Radiografia , Reoperação/estatística & dados numéricos , Índice de Gravidade de Doença , Resultado do Tratamento
17.
J Bone Joint Surg Am ; 81(5): 690-6, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-10360697

RESUMO

BACKGROUND: Thromboembolism is a common and important complication after total hip arthroplasty. A variety of pharmacological and mechanical measures have been proposed for prophylaxis. The purpose of the present study was to evaluate the efficacy of intermittent pneumatic compression as prophylaxis against thromboembolism following total hip arthroplasty. METHODS: The prospective study involved a consecutive series of 425 patients in whom a total of 502 (324 primary and 178 revision) total hip arthroplasties had been performed by two surgeons. The patients were managed intraoperatively and postoperatively with use of thigh-high elastic compression stockings and thigh-high intermittent pneumatic compression sleeves. Experienced vascular technologists performed venous duplex ultrasonography on both lower extremities of all patients at a mean of six days (range, two to fifteen days) postoperatively. All patients were followed for at least one year in order to detect late thromboembolism. RESULTS: An asymptomatic deep-vein thrombosis was noted on the scans made after twenty-three (4.6 percent) of the 502 procedures. Nineteen (3.8 percent) of the arthroplasties were followed by the development of a proximal thrombosis and four (0.8 percent), a distal thrombosis. Nineteen of the thromboses were ipsilateral (eighteen were proximal and one, distal), and four were contralateral (one was proximal and three, distal). No symptomatic deep-vein thrombosis developed in the hospital. In addition, three (two proximal and one distal) symptomatic ipsilateral deep-vein thromboses (a prevalence of 0.6 percent) developed three to twenty-three weeks after postoperative scans revealed negative findings and the patients were discharged from the hospital. Three symptomatic pulmonary embolisms (a prevalence of 0.6 percent) were confirmed by ventilation-perfusion scanning while the patients were in the hospital. There were no symptomatic pulmonary embolisms after discharge, and there were no fatal pulmonary embolisms. With the numbers available, we were unable to detect an association between deep-vein thrombosis and age (p = 0.76), gender (p = 0.13), body-mass index (p = 0.12), type of arthroplasty (primary or revision) (p = 0.12), operative approach (p = 0.37), duration of the operation (p = 0.21), type of anesthesia (general or regional) (p = 0.51), units of blood transfused (autologous, p = 0.79; homologous, p = 0.57), blood type (p = 0.18), or the presence of a so-called classic risk factor for the development of thrombosis (p = 0.22). Five arthroplasties (1.0 percent) were followed by the development of a wound hematoma, but only one hematoma necessitated operative drainage. CONCLUSIONS: The use of intraoperative and postoperative thigh-high intermittent pneumatic compression, combined with duplex ultrasonography performed by experienced vascular technologists, is effective for prophylaxis against thromboembolism after both primary and revision total hip arthroplasties. The low prevalence of deep-vein thrombosis (4.6 percent) and symptomatic pulmonary embolism (0.6 percent) is comparable with that associated with pharmacological prophylaxis.


Assuntos
Artroplastia de Quadril , Trajes Gravitacionais , Complicações Pós-Operatórias/prevenção & controle , Embolia Pulmonar/prevenção & controle , Trombose Venosa/prevenção & controle , Bandagens , Estudos de Casos e Controles , Contrapulsação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Estudos Prospectivos , Reoperação , Ultrassonografia Doppler Dupla , Trombose Venosa/diagnóstico por imagem
18.
J Arthroplasty ; 14(3): 288-92, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10220181

RESUMO

The Insall-Burstein and Insall-Burstein II posterior-stabilized (I-B II PS) prostheses have been reported to have a high prevalence of patellar complications. This is a prospective, consecutive study of 118 primary total knee arthroplasties in 82 patients with the I-B II PS prosthesis implanted by 1 surgeon, using a specific technique for patellar resurfacing. The mean follow-up time was 4.0 years (range, 2-8 years). Clinical evaluation was performed using a standard knee score system with specific additional evaluation of the patellofemoral joint. Radiographs were evaluated for fracture, loosening, and subluxation. Ninety-four knees (80%) were rated excellent, 21 knees (17%) good, and 3 knees (3%) fair. The mean flexion was 112 degrees postoperative. No knee required reoperation for the patellofemoral joint. There were 2 nondisplaced and 1 minimally displaced patellar fractures treated nonoperatively, no patellar clunk syndrome, and no subluxations. Using the patellar evaluation system, 109 knees had no anterior knee pain, 7 knees had mild pain, and 2 knees (1 patient) had moderate-to-severe pain only with rising from a chair. Patellofemoral crepitus with active flexion-extension in the seated position was noted in 16 knees (14%) but was painful in only 2 knees (1 patient). With this technique for patellar resurfacing with this prosthesis, patellofemoral complications were only 4.2%, and no knee required reoperation for the patella or for loosening. With attention to operative technique, patellofemoral resurfacing with this posterior-stabilized total knee arthroplasty can be highly successful.


Assuntos
Artroplastia do Joelho/efeitos adversos , Prótese do Joelho/efeitos adversos , Idoso , Artralgia/epidemiologia , Artroplastia do Joelho/métodos , Feminino , Seguimentos , Humanos , Articulação do Joelho/fisiopatologia , Masculino , Patela , Estudos Prospectivos , Desenho de Prótese , Amplitude de Movimento Articular , Fatores de Tempo , Resultado do Tratamento
19.
Clin Orthop Relat Res ; (360): 169-73, 1999 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10101322

RESUMO

Twenty-three total knee arthroplasties in 15 patients with severe hemophilia were performed between February 1974 and September 1988. Thirteen patients had Factor VIII deficiency and two had Factor IX deficiency. The mean followup period was 7.5 years, with a minimum of 4 years for patients who were alive (eight) at the time of this review. Seven patients had died before this report, and all were seropositive for the human immunodeficiency virus. Using the Hospital for Special Surgery knee scoring system, the result was excellent in one knee, good in three, fair in two, and poor in 17. One patient was seropositive for the human immunodeficiency virus at the time of the index procedure, and 12 were seropositive at the most recent followup; the human immunodeficiency status of three patients was unknown. There were two early and two late deep infections, all in patients who were seropositive for the human immunodeficiency virus. The most recent postoperative radiographs for all knees were reviewed using the Knee Society radiographic scoring system. Ten femoral components were well fixed, 11 were possibly loose, and two were probably loose. Eight tibial components were well fixed, 10 possibly loose, three probably loose, and two definitely loose. One knee had been revised for aseptic loosening. There are few published studies of the long term results of total knee arthroplasties in patients with hemophilia. In this series of 23 knees, there was a high rate of loosening and infection. Total knee arthroplasty may be a useful treatment for the relief of pain attributable to end stage hemophilic arthropathy, but there is a high rate of complications, especially in patients who are seropositive for the human immunodeficiency virus.


Assuntos
Artroplastia do Joelho , Hemofilia A/complicações , Articulação do Joelho , Adolescente , Adulto , Feminino , Humanos , Artropatias/complicações , Artropatias/cirurgia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA