Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Epidemiol Infect ; 145(6): 1276-1284, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28091335

RESUMO

Cervical cancer is the second most frequent cancer in women in French Guiana. Studies have shown that populations living in the remote areas of the interior have early sexual debut and that multiple sexual partnerships are common. The objective of the present study was thus to determine the prevalence of human papillomavirus (HPV) infection in these areas. A study was conducted in women aged 20-65 years with previous sexual activity. Women were included on a voluntary basis after using local media and leaders to inform them of the visit of the team. HPV infection was defined by the detection of HPV DNA using the Greiner Bio-One kit. In addition to HPV testing cytology was performed. The overall age-standardized prevalence rate was 35%. There was a U-shaped evolution of HPV prevalence by age with women aged >50 years at highest risk for HPV, followed by the 20-29 years group. Twenty-seven percent of women with a positive HPV test had normal cytology. Given the high incidence of cervical cancer in French Guiana and the high prevalence of HPV infections the present results re-emphasize the need for screening for cervical cancer in these remote areas. Vaccination against HPV, preferably with a nonavalent vaccine, also seems an important prevention measure. However, in this region where a large portion of the population has no health insurance, this still represents a challenge.


Assuntos
DNA Viral/análise , Papillomaviridae/isolamento & purificação , Infecções por Papillomavirus/epidemiologia , Adulto , Idoso , Técnicas Citológicas , DNA Viral/genética , Estudos Epidemiológicos , Feminino , Guiana Francesa/epidemiologia , Genótipo , Técnicas de Genotipagem , Humanos , Pessoa de Meia-Idade , Papillomaviridae/classificação , Papillomaviridae/genética , Infecções por Papillomavirus/virologia , Prevalência , Esfregaço Vaginal , Adulto Jovem
2.
Phys Med Biol ; 59(11): 2747-65, 2014 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-24800943

RESUMO

Monte Carlo calculations are increasingly used to assess stray radiation dose to healthy organs of proton therapy patients and estimate the risk of secondary cancer. Among the secondary particles, neutrons are of primary concern due to their high relative biological effectiveness. The validation of Monte Carlo simulations for out-of-field neutron doses remains however a major challenge to the community. Therefore this work focused on developing a global experimental approach to test the reliability of the MCNPX models of two proton therapy installations operating at 75 and 178 MeV for ocular and intracranial tumor treatments, respectively. The method consists of comparing Monte Carlo calculations against experimental measurements of: (a) neutron spectrometry inside the treatment room, (b) neutron ambient dose equivalent at several points within the treatment room, (c) secondary organ-specific neutron doses inside the Rando-Alderson anthropomorphic phantom. Results have proven that Monte Carlo models correctly reproduce secondary neutrons within the two proton therapy treatment rooms. Sensitive differences between experimental measurements and simulations were nonetheless observed especially with the highest beam energy. The study demonstrated the need for improved measurement tools, especially at the high neutron energy range, and more accurate physical models and cross sections within the Monte Carlo code to correctly assess secondary neutron doses in proton therapy applications.


Assuntos
Método de Monte Carlo , Nêutrons , Terapia com Prótons/métodos , Doses de Radiação , Humanos , Imagens de Fantasmas , Terapia com Prótons/instrumentação , Dosagem Radioterapêutica
3.
Radiat Prot Dosimetry ; 161(1-4): 290-4, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24500239

RESUMO

Particles originating from primary cosmic radiation, which hit the Earth's atmosphere give rise to a complex field of secondary particles. These particles include neutrons, protons, muons, pions, etc. Since the 1980s it has been known that terrestrial cosmic rays can penetrate the natural shielding of buildings, equipment and circuit package and induce soft errors in integrated circuits. Recently, research has shown that commercial static random access memories are now so small and sufficiently sensitive that single event upsets (SEUs) may be induced from the electronic stopping of a proton. With continued advancements in process size, this downward trend in sensitivity is expected to continue. Then, muon soft errors have been predicted for nano-electronics. This paper describes the effects in the specific cases such as neutron-, proton- and muon-induced SEU observed in complementary metal-oxide semiconductor. The results will allow investigating the technology node sensitivity along the scaling trend.


Assuntos
Radiação Cósmica , Mésons , Nêutrons , Astronave/instrumentação , Algoritmos , Altitude , Atmosfera , Eletrônica , Desenho de Equipamento , Transferência Linear de Energia , Metais/química , Modelos Teóricos , Óxidos/química , Prótons , Reprodutibilidade dos Testes , Medição de Risco , Semicondutores , Silício/química , Atividade Solar
4.
Radiat Prot Dosimetry ; 161(1-4): 363-7, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24222710

RESUMO

Monte Carlo simulations were used to assess secondary neutron doses received by patients treated with proton therapy for ocular melanoma and craniopharyngioma. MCNPX calculations of out-of-field doses were done for ∼20 different organs considering realistic treatment plans and using computational phantoms representative of an adult male individual. Simulations showed higher secondary neutron doses for intracranial treatments, ∼14 mGy to the salivary glands, when compared with ocular treatments, ∼0.6 mGy to the non-treated eye. This secondary dose increase is mainly due to the higher proton beam energy (178 vs. 75 MeV) as well as to the impact of the different beam parameters (modulation, collimation, field size etc.). Moreover, when compared with published data, the assessed secondary neutron doses showed similar trends, but sometimes with sensitive differences. This confirms secondary neutrons to be directly dependent on beam energy, modulation technique, treatment configuration and methodology.


Assuntos
Craniofaringioma/radioterapia , Neoplasias Oculares/radioterapia , Melanoma/radioterapia , Nêutrons , Terapia com Prótons/efeitos adversos , Terapia com Prótons/métodos , Adulto , Simulação por Computador , Olho/efeitos da radiação , Humanos , Masculino , Modelos Teóricos , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação , Radiometria , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Glândulas Salivares/efeitos da radiação
5.
Radiat Prot Dosimetry ; 161(1-4): 284-9, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24345464

RESUMO

In this paper, a Bonner Sphere Spectrometer extended to high energies (HERMEIS) was employed to measure continuously the cosmic-ray-induced neutron spectra over a long-term period (2 y) at mountain altitude and medium geomagnetic latitude (Pic du Midi de Bigorre in the French Pyrenees, +2885 m, 5.6 GV). The results showed 1-y sinusoidal oscillations in the integrated fluence rates. The amplitude of these oscillations depends on the neutron energetic domain. The fluence rate of thermal neutrons was 53 % higher in August than that in February. Those of epithermal neutrons with energies between 0.4 eV and 0.1 MeV and evaporation neutrons (from 0.1 to 20 MeV) were ∼25 % higher in the summer than those in the winter. Finally, the cascade neutron fluence rate (>20 MeV) remained quite the same (<10 % variation). To understand the effects of local and seasonal changes in the measurement environment, GEANT4 simulations were performed. The nature of rock and thickness of the snow cover during the winter period (given by meteorological data) were investigated. A reasonable agreement between experiments and calculations was found.


Assuntos
Radiação Cósmica , Nêutrons , Radiometria/instrumentação , Radiometria/métodos , Algoritmos , Simulação por Computador , Meio Ambiente , Desenho de Equipamento , França , Método de Monte Carlo , Oscilometria , Doses de Radiação , Proteção Radiológica/métodos , Estações do Ano , Neve , Software , Temperatura , Água
6.
Med Trop (Mars) ; 69(4): 345-50, 2009 Aug.
Artigo em Francês | MEDLINE | ID: mdl-19725384

RESUMO

The arboviral disease with the highest human incidence in South America is dengue fever. In French Guiana, where all four dengue serotypes, i.e., DENV-1, DENV-2, DENV-3 and DENV-4, are present, the disease is endemic with epidemic outbreaks. Though previous serological studies have suggested a sylvatic cycle, involvement of wild mammals in the dengue cycle in the neotropics has never been confirmed. The purpose of this study was to search for the presence of DENV in wild animals captured at two different sites between 2001 and 2007. About 10,000 trap/nights were performed leading to the capture of 464 non-flying mammals (rodents and marsupials). In addition, mistnests placed in the same zone yielded 152 bats. Reverse transcription-polymerase chain reaction amplification to detect infection by any of the four dengue serotypes demonstrated viral RNA in the livers and/or sera of 92 captured animals. Sequence analysis of amplification products revealed that the DENV-1, DENV-3 and DENV-4 serotypes were distinct from those circulating in humans at the same periods. Analysis for DENV-2 showed that some strains were divergent from concurrent human strains but that others were identical. The latter finding suggests that wild neotropical mammals living in periurban area can be infected by dengue virus strains circulating in humans. However, further investigation will be needed to determine if neotropical mammals are incidental hosts or potential reservoirs of dengue virus.


Assuntos
Dengue/transmissão , Vetores de Doenças , Mamíferos/virologia , Clima Tropical , Animais , Dengue/classificação , Dengue/genética , Humanos , RNA Viral/isolamento & purificação , Reação em Cadeia da Polimerase Via Transcriptase Reversa
7.
Radiat Prot Dosimetry ; 131(1): 7-14, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18782783

RESUMO

Within the scope of CONRAD (A Coordinated Action for Radiation Dosimetry) Work Package 4 on Computational Dosimetry jointly collaborated with the other research actions on internal dosimetry, complex mixed radiation fields at workplaces and medical staff dosimetry. Besides these collaborative actions, WP4 promoted an international comparison on eight problems with their associated experimental data. A first set of three problems, the results of which are herewith summarised, dealt only with the expression of the stochastic uncertainties of the results: the analysis of the response function of a proton recoil telescope detector, the study of a Bonner sphere neutron spectrometer and the analysis of the neutron spectrum and dosimetric quantity H(p)(10) in a thermal neutron facility operated by IRSN Cadarache (the SIGMA facility). A second paper will summarise the results of the other five problems which dealt with the full uncertainty budget estimate. A third paper will present the results of a comparison on in vivo measurements of the (241)Am bone-seeker nuclide distributed in the knee. All the detailed papers will be presented in the WP4 Final Workshop Proceedings.


Assuntos
Radiometria , Radioterapia Assistida por Computador , Humanos , Modelos Teóricos , Nêutrons , Prótons , Radiometria/instrumentação , Radioterapia Assistida por Computador/instrumentação , Processos Estocásticos
8.
Radiat Prot Dosimetry ; 126(1-4): 471-6, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17823130

RESUMO

The availability of active neutron personal dosemeters has made real time monitoring of neutron doses possible. This has obvious benefits, but is only of any real assistance if the dose assessments made are of sufficient accuracy and reliability. Preliminary assessments of the performance of active neutron dosemeters can be made in calibration facilities, but these can never replicate the conditions under which the dosemeter is used in the workplace. Consequently, it is necessary to assess their performance in the workplace, which requires the field in the workplace to be fully characterised in terms of the energy and direction dependence of the fluence. This paper presents an overview of developments in workplace neutron dosimetry but concentrates on the outcomes of the EVIDOS project, which has made significant advances in the characterisation of workplace fields and the analysis of dosemeter responses in those fields.


Assuntos
Ciclotrons , Modelos Biológicos , Nêutrons , Exposição Ocupacional/análise , Radiometria/métodos , Radiometria/tendências , Carga Corporal (Radioterapia) , Simulação por Computador , Humanos , Masculino , Modelos Estatísticos , Doses de Radiação , Espanha
9.
Radiat Prot Dosimetry ; 124(3): 219-29, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17890781

RESUMO

Within the EC project EVIDOS, 17 different mixed neutron-photon workplace fields at nuclear facilities (boiling water reactor, pressurised water reactor, research reactor, fuel processing, storage of spent fuel) were characterised using conventional Bonner sphere spectrometry and newly developed direction spectrometers. The results of the analysis, using Bayesian parameter estimation methods and different unfolding codes, some of them especially adapted to simultaneously unfold energy and direction distributions of the neutron fluence, showed that neutron spectra differed strongly at the different places, both in energy and direction distribution. The implication of the results for the determination of reference values for radiation protection quantities (ambient dose equivalent, personal dose equivalent and effective dose) and the related uncertainties are discussed.


Assuntos
Nêutrons , Reatores Nucleares , Exposição Ocupacional/análise , Fótons , Monitoramento de Radiação/métodos , Análise Espectral/instrumentação , União Europeia , Humanos , Análise Espectral/métodos , Local de Trabalho
10.
Radiat Prot Dosimetry ; 124(3): 213-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17893081

RESUMO

Ratios of H(p)(10) and H*(10) were determined with reference instruments in a number of workplace fields within the nuclear industry and used to derive workplace-specific correction factors. When commercial survey meter results together with these factors were applied to the results of the locally used personal dosemeters their results improved and became within 0.7 and 1.7 of the reference values or better depending on the response of the survey meter. A similar result was obtained when a correction was determined with a prototype reference instrument for H(p)(10) after adjustment of its response. Commercially available survey instruments both for photon and neutron H*(10) measurements agreed with the reference instruments in most cases to within 0.5-1.5. Those conclusions are derived from results reported within the EC supported EVIDOS contract.


Assuntos
Nêutrons , Reatores Nucleares , Exposição Ocupacional/análise , Fótons , Doses de Radiação , Monitoramento de Radiação/métodos , União Europeia , Humanos , Proteção Radiológica/métodos , Medição de Risco , Local de Trabalho
11.
Radiat Prot Dosimetry ; 125(1-4): 300-3, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17846030

RESUMO

Neutron survey instruments have been exposed at all the measurement locations used in the EVIDOS project. These results have an important impact in the interpretation of the results from the project, since operationally the survey instrument will be used for an initial assessment of and routine monitoring of the ambient dose equivalent dose rate. Additionally, since the response of these instruments is in some cases very well characterised, their systematic deviations from the reference quantities provide an important verification of the determination of those quantities.


Assuntos
Exposição Ambiental/análise , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Internacionalidade , Nêutrons , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Radiat Prot Dosimetry ; 125(1-4): 185-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17578872

RESUMO

The Institute for Radiological Protection and Nuclear Safety owns two facilities producing realistic mixed neutron-photon radiation fields, CANEL, an accelerator driven moderator modular device, and SIGMA, a graphite moderated americium-beryllium assembly. These fields are representative of some of those encountered at nuclear workplaces, and the corresponding facilities are designed and used for calibration of various instruments, such as survey meters, personal dosimeters or spectrometric devices. In the framework of the European project EVIDOS, irradiations of personal dosimeters were performed at CANEL and SIGMA. Monte Carlo calculations were performed to estimate the reference values of the personal dose equivalent at both facilities. The Hp(10) values were calculated for three different angular positions, 0 degrees, 45 degrees and 75 degrees, of an ICRU phantom located at the position of irradiation.


Assuntos
Análise de Falha de Equipamento , Modelos Estatísticos , Método de Monte Carlo , Exposição Ocupacional/análise , Aceleradores de Partículas/instrumentação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Algoritmos , Carga Corporal (Radioterapia) , Simulação por Computador , Desenho de Equipamento , Internacionalidade , Nêutrons , Exposição Ocupacional/prevenção & controle , Fótons , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Medição de Risco/métodos , Sensibilidade e Especificidade
13.
Radiat Prot Dosimetry ; 126(1-4): 58-63, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17578877

RESUMO

The Institute for Radiological Protection and Nuclear Safety owns a graphite-moderated AmBe neutron field facility, SIGMA, that has to be reconstructed. Monte-Carlo simulations were performed to study the design of a new thermal facility based on IRSN existing facilities. Studies related to an update version of SIGMA concerned the enhancement of the thermal neutrons contribution to the dose equivalent. Calculations were mainly performed for a (252)Cf neutron source distribution located at the centre of a graphite moderator block. A quasi-pure thermal neutron field was obtained with a 2.4 x 2.4 x 2.4-m(3) block of graphite. A second acceptable neutron field was obtained with 3.3-MeV mono-energetic neutrons created by a 400-kV accelerator coupled to a graphite assembly of 1.5 x 1.5 x 1.5 m(3). The characteristics of the studied thermal fields with the requirement for a reference calibration field are compared, and the advantages and drawbacks of the different producing methods are discussed.


Assuntos
Desenho Assistido por Computador , Modelos Estatísticos , Método de Monte Carlo , Nêutrons , Aceleradores de Partículas/instrumentação , Radiometria/métodos , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Temperatura Alta , Doses de Radiação , Espalhamento de Radiação
14.
Radiat Prot Dosimetry ; 125(1-4): 170-4, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17573369

RESUMO

This paper presents the assessment of the neutron field near the VENUS reactor, particularly in areas near the reactor shielding where operators are frequently present during a reactor run. To obtain reference spectra in the area of interest, MCNPX simulations were performed. Reference spectrometry was also performed using a Bonner spheres system. The outcome of both calculations and measurements is compared.


Assuntos
Análise de Falha de Equipamento , Reatores Nucleares , Exposição Ocupacional/análise , Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Carga Corporal (Radioterapia) , Simulação por Computador , Desenho de Equipamento , Internacionalidade , Modelos Estatísticos , Método de Monte Carlo , Nêutrons , Exposição Ocupacional/prevenção & controle , Proteção Radiológica/instrumentação , Reprodutibilidade dos Testes , Medição de Risco/métodos , Sensibilidade e Especificidade , Análise Espectral/instrumentação , Análise Espectral/métodos
15.
Radiat Prot Dosimetry ; 126(1-4): 491-6, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17496292

RESUMO

The European Commission is funding within its Sixth Framework Programme a three-year project (2005-2007) called CONRAD, COordinated Network for RAdiation Dosimetry. The organisational framework for this project is provided by the European Radiation Dosimetry Group EURADOS. One task within the CONRAD project, Work Package 6 (WP6), was to provide a report outlining research needs and research activities within Europe to develop new and improved methods and techniques for the characterisation of complex radiation fields at workplaces around high-energy accelerators, but also at the next generation of thermonuclear fusion facilities. The paper provides an overview of the report, which will be available as CERN Yellow Report.


Assuntos
Nêutrons , Fusão Nuclear , Reatores Nucleares , Exposição Ocupacional/análise , Aceleradores de Partículas/instrumentação , Proteção Radiológica/instrumentação , Radiometria/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Europa (Continente) , Doses de Radiação , Proteção Radiológica/métodos , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Radiat Prot Dosimetry ; 126(1-4): 145-50, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17526481

RESUMO

The photon contribution to ambient dose equivalent in several wide-spectrum reference neutrons fields of the Institute for Radiological Protection and Nuclear Safety were measured using a Geiger-Müller counter. For the investigated fields, the ratio of photon to neutron ambient dose equivalent ranged between 0.03 and 0.20. The results show that the Geiger-Müller tube is a versatile instrument for dosimetry in mixed photon-neutron fields if sufficient information for the calculation of corrections is available.


Assuntos
Algoritmos , Artefatos , Nêutrons , Radiometria/métodos , Radiometria/normas , Análise Espectral/normas , Europa (Continente) , Fótons , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Radiat Prot Dosimetry ; 125(1-4): 275-80, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17522043

RESUMO

Supported by the European Commission, the EVIDOS project started in November 2001 with the broad goal of evaluating state of the art dosimetry techniques in representative workplaces of the nuclear industry. Seven European institutes joined efforts with end users at nuclear power plants, at fuel processing and reprocessing plants, and at transport and storage facilities. A comprehensive programme was devised to evaluate capabilities and limitations of standard and innovative personal dosemeters in relation to the mixed neutron-photon fields of concern to the nuclear industry. This paper describes the criteria behind the selection of dosimetry techniques and workplaces that were analysed, as well as the organisation of the measurement campaigns. Particular emphasis was placed on the evaluation of a variety of electronic personal dosemeters, either commercially available or previously developed by the partners. The estimates provided by these personal dosemeters were compared to reference values of dose equivalent quantities derived from spectrometry and fluence-to-dose equivalent conversion coefficients. Spectrometry was performed both with conventional multisphere and with some original instrumentation providing energy and direction resolution, based on silicon detectors and superheated drop detectors mounted on or in spherical moderators. The results were collected in a large, searchable database and are intended to be used in the harmonisation of dosimetric procedures for mixed radiation fields and for the approval of dosimetry services in Europe.


Assuntos
Exposição Ambiental/análise , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , União Europeia , Internacionalidade , Nêutrons , Fótons , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Radiat Prot Dosimetry ; 126(1-4): 366-70, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17513852

RESUMO

The Grup de Física de les Radiacions (GFR) of the Universitat Autònoma de Barcelona (UAB), in collaboration with the Institute for Radiological Protection and Nuclear Safety (IRSN), has developed a passive Bonner sphere system (UAB-BSS), with gold foils as thermal neutron detectors, for application in pulsed neutron fields or in mixed neutron-photon fields with high photon intensities. In such fields, active devices suffer from saturation and dead-time effects. The MCNPX Monte-Carlo code has been used to determine the response to neutrons of different energies of each polyethylene sphere belonging to the BSS. The passive UAB-BSS system was characterised with the ISO (252)Cf reference source at the IRSN facilities. The energy distribution of the reference source neutron fluence was folded with the response functions for comparison with the experimental data. A good agreement between the experimental and calculated count rates was found.


Assuntos
Ouro/química , Ouro/efeitos da radiação , Modelos Teóricos , Nêutrons , Exposição Ocupacional/análise , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Método de Monte Carlo , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Radiat Prot Dosimetry ; 126(1-4): 337-41, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17513860

RESUMO

A passive Bonner sphere system (BSS), based on thermal neutron activation detectors, was developed to perform neutron spectrometry in pulsed and very intense (n-gamma) fields with predominant photon component, as those produced by high energy (>10 MV) medical linear electron accelerators. In this paper, a description of the new system is presented together with an experimental characterisation of a portable Sodium Iodide (NaI) detector and a fixed high-purity Germanium one, both used to measure the induced gamma-activity of the activated materials, respectively, in situ and in the laboratory. The choice of the activated materials is justified according to pre-established practical considerations and physical criteria. The response functions of the entire passive BSS were calculated using the MCNPX code. A preliminary experimental validation with a bare (252)Cf source is given as well.


Assuntos
Nêutrons , Fótons , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Análise Espectral/instrumentação , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Radiat Prot Dosimetry ; 126(1-4): 151-4, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17519241

RESUMO

Workplace neutron spectra from nuclear facilities obtained within the European project EVIDOS are compared with those of the simulated workplace fields CANEL and SIGMA and fields set-up with radionuclide sources at the PTB. Contributions of neutrons to ambient dose equivalent and personal dose equivalent are given in three energy intervals (for thermal, intermediate and fast neutrons) together with the corresponding direction distribution, characterised by three different types of distributions (isotropic, weakly directed and directed). The comparison shows that none of the simulated workplace fields investigated here can model all the characteristics of the fields observed at power reactors.


Assuntos
Exposição Ambiental/análise , Modelos Teóricos , Nêutrons , Reatores Nucleares , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Simulação por Computador , Europa (Continente) , Programas Governamentais , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...