Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Schizophr Bull ; 44(3): 505-514, 2018 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-29897597

RESUMO

INTRODUCTION: Despite extensive testing, the efficacy of low-frequency (1 Hz) repetitive transcranial magnetic stimulation (rTMS) of temporo-parietal targets for the treatment of auditory verbal hallucinations (AVH) in patients with schizophrenia is still controversial, but promising results have been reported with both high-frequency and neuronavigated rTMS. Here, we report a double-blind sham-controlled study to assess the efficacy of high-frequency (20 Hz) rTMS applied over a precise anatomical site in the left temporal region using neuronavigation. METHODS: Fifty-nine of 74 randomized patients with schizophrenia or schizoaffective disorders (DSM-IV R) were treated with rTMS or sham treatment and fully evaluated over 4 weeks. The rTMS target was determined by morphological MRI at the crossing between the projection of the ascending branch of the left lateral sulcus and the superior temporal sulcus (STS). RESULTS: The primary outcome was response to treatment, defined as a 30% decrease of the Auditory Hallucinations Rating Scale (AHRS) frequency item, observed at 2 successive evaluations. While there was no difference in primary outcome between the treatment groups, the percentages of patients showing a decrease of more than 30% of AHRS score (secondary outcome) did differ between the active (34.6%) and sham groups (9.1%) (P = .016) at day 14. DISCUSSION: This controlled study reports negative results on the primary outcome but demonstrates a transient effect of 20 Hz rTMS guided by neuronavigation and targeted on an accurate anatomical site for the treatment of AVHs in schizophrenia patients.


Assuntos
Alucinações/terapia , Avaliação de Resultados em Cuidados de Saúde , Transtornos Psicóticos/terapia , Esquizofrenia/terapia , Lobo Temporal/fisiopatologia , Estimulação Magnética Transcraniana/métodos , Adulto , Método Duplo-Cego , Feminino , Alucinações/etiologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Neuronavegação/métodos , Transtornos Psicóticos/complicações , Esquizofrenia/complicações
2.
Neurosurgery ; 71(3): E757-62; discussion E763, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22653388

RESUMO

BACKGROUND AND IMPORTANCE: There is large variation in the success of decompressive surgery for pudendal neuralgia (PN), the most chronic, disabling form of perineal pain. We attempt to determine whether spinal cord stimulation using new-generation multicolumn leads could form part of the treatment algorithm for refractory PN. CLINICAL PRESENTATION: A man with PN that was unresponsive to conventional treatment demonstrated a neuropathic component and had a negative response to nerve infiltrations (so he was not indicated for decompressive surgery) and a positive response to perianal transcutaneous electrical nerve stimulation and was implanted with a 16-contact surgical lead at the level of conus medullaris, allowing multicolumn stimulation. Using transverse combinations, it was possible to obtain 100% paresthesia over the perineal area without unwanted dorsal root stimulation. Perineal and radicular pain was successfully relieved for up to 12 months (80% and 60% reduction in the visual analogue scale scores, respectively), with an improvement in all quality of life domains and a reduction in drug consumption. CONCLUSION: Spinal cord stimulation using a 16-contact lead may be a viable therapeutic option for patients with refractory PN for whom decompressive surgery is contraindicated.


Assuntos
Neuralgia do Pudendo/terapia , Estimulação da Medula Espinal/métodos , Eletrodos Implantados , Humanos , Masculino , Pessoa de Meia-Idade
3.
Pacing Clin Electrophysiol ; 32(3): 399-402, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19272073

RESUMO

Twiddler's or twist syndrome is the twisting of pulse generators around themselves. It may result from mechanical manipulation that can induce the malfunction of the device. In this case, twiddler's syndrome resulted from compulsive checking of the device. The implantable cardioverter-defibrillator (ICD) triggered the development of an obsessive compulsive disorder (OCD). Two invasive procedures were required to replace the ICD. Psychiatric intervention prevented the recurrence of twiddler's syndrome in this patient for more than 2 years. We believe that preimplant psychiatric assessment should be the rule.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Falha de Equipamento , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/cirurgia , Transtorno Obsessivo-Compulsivo/complicações , Transtorno Obsessivo-Compulsivo/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Transtorno Obsessivo-Compulsivo/diagnóstico , Transtorno Obsessivo-Compulsivo/psicologia , Síndrome , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...