1.
J Environ Monit ; 14(8): 2145-53, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22766850

RESUMO

Monitoring personal exposure to particle matter (PM(2.5)) in ambient air requires performing measurements using portable monitors. In this work, the portable nephelometer SidePak™ AM510 Personal Aerosol Monitor manufactured by TSI Inc. was evaluated against a Tapered Element Oscillating Microbalance (TEOM) equipped with a Filter Dynamics Measurements System (FDMS). Conventionally, the SidePak is calibrated with respect to the Arizona Road Test Dust and then multiplied by an environmental calibration factor to yield mass concentration. To adapt this calibration to specific field conditions, we present an implementation of this calibration by introducing a growing factor correction which takes into account relative humidity and the dry and wet portions of the refractive index estimated from TEOM-FDMS measurements. PM(2.5) sampling with several SidePaks AM510 was carried out in background and rural sites in the Po Valley (Italy). Modeled SidePak data were plotted vs. reference TEOM-FDMS data which show a good agreement.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/instrumentação , Nefelometria e Turbidimetria/instrumentação , Material Particulado/análise , Monitoramento Ambiental/métodos , Humanos , Modelos Químicos , Nefelometria e Turbidimetria/métodos , Tamanho da Partícula
2.
J Environ Monit ; 8(1): 112-9, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16395467

RESUMO

This study presents an evaluation of the extent of differences between measurements performed by O(3) and NO(2) diffusive samplers and by the reference methods for diffusive samplers commercially available. The tests were performed in an exposure chamber under extreme conditions of controlling factors and under field conditions. For NO(2), the results of the laboratory experiments showed that most of the diffusive samplers were affected by extreme exposure conditions. The agreement between the samplers and the reference method was better for the field tests than for the laboratory ones. The estimate of the uptake rate for the exposure conditions using a model equation improved the agreement between the diffusive samplers and the reference methods. The agreement between O(3) measured by the diffusive samplers and by the reference method was satisfactory for 1-week exposure. For 8-hour exposures, the diffusive samplers with high uptake rates quantified better the O(3) concentration than the samplers with low uptake rates. As for NO(2), the results of the O(3) field tests were in better agreement with the reference method than the ones of the laboratory tests. The field tests showed that the majority of diffusive samplers fulfils the 25% uncertainty requirement of the NO(2) European Directive and the 30% uncertainty requirement of the O(3) European Directive for 1-week exposure.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/instrumentação , Dióxido de Nitrogênio/análise , Ozônio/análise , Difusão , Monitoramento Ambiental/métodos , Laboratórios
3.
J Environ Monit ; 8(1): 174-82, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16395476

RESUMO

This paper presents the results of a feasability study for the preparation and certification of reference materials (RMs) for nitrogen dioxide (NO(2)) and sulfur dioxide (SO(2)) in diffusive samplers. RMs for NO(2) were prepared by exposure to gas mixtures in a chamber while the RMs for SO(2) were prepared by liquid spiking. Certification of RMs for NO(2) was found feasible with a certified uncertainty of 5.8% and a proposed shelf life of 5 years. The uncertainty was calculated with contribution from the homogeneity of preparation, stability and transport of the CRMs and from an external verification of the certified value. To reach 5.8% of uncertainty, the contribution of the differences between the results of analysis by ion chromatography and colorimetry must be eliminated. It is proposed to solve this by pre-extracting the samplers with water before analysis. The results of this study indicate that the samplers are stable for at least two years before and after exposure when stored in a refrigerator. By contrast, the certification of RMs for SO(2) was found to not be feasible due to instability problems. This instability was attributed to reaction of sulfate on the walls of the samplers. Alternatively, the preparation of RMs by simultaneous exposure to SO(2) and NO(2) has been tested. Satisfying homogeneities has been reached both for NO(2) and SO(2).


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/normas , Dióxido de Nitrogênio/análise , Dióxido de Enxofre/análise , Certificação , Difusão , Estudos de Viabilidade , Padrões de Referência
SELEÇÃO DE REFERÊNCIAS