Eur J Heart Fail ; 14(4): 351-6, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22308012

RESUMO

Today, continuous-flow left ventricular assist devices (cf-LVADs) are implanted more often in patients with end-stage heart failure. Because of greater durability they can be implanted for an extended period of time. As a result of increased numbers of patients on cf-LVAD support, healthcare professionals should be aware of the potential complications inherent to this therapy. Both bleeding and thrombosis may occur, and also complications related either to the device itself or to the ensuing altered haemodynamics, valvular pathology, and rhythm disturbances such as ventricular tachycardias and fibrillation. Accurate clinical evaluation, together with an electrocardiogram and, if necessary, combined with an echocardiogram, is obligatory in these situations. This review summarizes common complications complemented by a few clinical cases.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Infecções/etiologia , Adulto , Arritmias Cardíacas/etiologia , Progressão da Doença , Insuficiência Cardíaca/patologia , Coração Auxiliar/estatística & dados numéricos , Hemodinâmica , Hemorragia/etiologia , Humanos , Doença Iatrogênica , Masculino , Pessoa de Meia-Idade , Adulto Jovem
3.
Curr Opin Organ Transplant ; 14(5): 554-9, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19667990

RESUMO

PURPOSE OF REVIEW: The first generation of implantable pulsatile ventricular assist devices (VADs) has proven to be successful as bridge to transplantation. Adverse events such as mechanical failure and infections, however, limit their use for long-term support (>1 year) or as alternative for heart transplantation. Newer second generation of nonpulsatile VADs shows less of such limitations. RECENT FINDINGS: As bridge to transplantation, we have seen a switch from pulsatile volume-displacement devices, like the HeartMate XVE LVAS and Novacor left ventricular assist device (LVAD), (first generation) to continuous flow devices like the HeartMate 2 and Berlin Heart Incor (second generation). These devices are smaller, quiet and mechanically more durable. Better long-term survival, lower infection rates, excellent mechanical durability and acceptable quality of life together with shortage of donor organs led also to an increasing usage of these devices as alternative to transplantation. Recent studies show in this respect encouraging results, with actuarial survival rates at 1 and 2 years of 70% or higher. Another result of long-term cardiac support is a bridge to recovery. Initial results of even smaller implantable centrifugal pumps like the HeartWare VAD are promising. SUMMARY: An overview of recent developments in mechanical circulatory support is presented.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Transplante de Coração , Ventrículos do Coração , Humanos , Desenho de Prótese , Implantação de Prótese
4.
Neth Heart J ; 16(3): 79-87, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18345330

RESUMO

Based on the changes in the field of heart transplantation and the treatment and prognosis of patients with heart failure, these updated guidelines were composed by a committee under the supervision of both the Netherlands Society of Cardiology and the Netherlands Association for Cardiothoracic surgery (NVVC and NVT).THE INDICATION FOR HEART TRANSPLANTATION IS DEFINED AS: 'End-stage heart disease not remediable by more conservative measures'.CONTRAINDICATIONS ARE: irreversible pulmonary hypertension/elevated pulmonary vascular resistance; active systemic infection; active malignancy or history of malignancy with probability of recurrence; inability to comply with complex medical regimen; severe peripheral or cerebrovascular disease and irreversible dysfunction of another organ, including diseases that may limit prognosis after heart transplantation.Considering the difficulties in defining end-stage heart failure, estimating prognosis in the individual patient and the continuing evolution of available therapies, the present criteria are broadly defined. The final acceptance is done by the transplant team which has extensive knowledge of the treatment of patients with advanced heart failure on the one hand and thorough experience with heart transplantation and mechanical circulatory support on the other hand. (Neth Heart J 2008;16:79-87.).

5.
Neth Heart J ; 16(2): 41-6, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18335020

RESUMO

BACKGROUND: A growing number of patients with end-stage heart failure undergo implantation of ventricular assist devices as a bridge to heart transplantation. OBJECTIVES: In this study we investigated whether functional and haemodynamic recovery after implantation is sufficient to warrant the use of them as long-term alternative to heart transplantation. METHODS: We compared peak VO(2) of a group of patients three months after implantation of a ventricular assist device and three months after heart transplantation. Furthermore, we analysed the degree of haemodynamic recovery, by comparing plasma levels of BNP and creatinine before and after implantation of the device. RESULTS: After implantation of a ventricular assist device, exercise capacity improved considerably; three months after implantation peak VO(2) was 20.0+/-4.9 ml/kg/min (52% of predicted for age and gender). After heart transplantation exercise capacity improved even further; 24.0+/-3.9 ml/ kg/min (62% of predicted for age and gender) (p<0.001). In the three months after implantation, BNP plasma levels decreased from 570+/-307 pmol/l to 31+/-25 pmol/l and creatinine levels decreased from 191+/-82 mumol/l to 82+/-25 mumol/l, indicating significant unloading of the ventricles and haemodynamic recovery. CONCLUSION: With regard to functional and haemodynamic recovery, the effect of implantation of a ventricular assist device is sufficient to justify its use as an alternative to heart transplantation. (Neth Heart J 2008;16:41-6.).

6.
Neth Heart J ; 15(2): 45-50, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17612659

RESUMO

BACKGROUND.: Due to the shortage of donor hearts, mechanical circulatory support is increasingly being used as a bridge to transplantation. In order to allow for more widespread use of ventricular assist devices it is mandatory that patients are not continuously hospitalised. We present the results of our experience with patients with end-stage heart failure, discharged from hospital after implantation of a ventricular assist device and followed in an outpatient setting. METHODS.: After an intensive training and education programme, focusing on the management of the percutaneous driveline and instructions on how to handle in case of an alarm or malfunction of the device, patients were discharged. They were followed in the outpatient department. All regular and unplanned visits were registered, including readmissions. RESULTS.: Twenty-seven patients treated with a ventricular assist device were discharged from hospital. There were 37 extra visits, of these, 27 were device related resulting in 21 readmissions (0.78/patient). We treated eight infectious episodes in four patients, all device related. Furthermore seven thromboembolic episodes occurred in four patients. One patient died because of multiorgan failure seven weeks after he was readmitted with an urosepsis. In our experience of 11.4 patient years at home while on the device, only 5% of the time was spent in hospital for complications. In comparison with patients on an assist device who stayed in hospital until transplantation, there were no more complications. CONCLUSION.: This study demonstrates that patients with end-stage heart failure, treated with a ventricular assist device, can be safely discharged from hospital, with an acceptable rate of readmissions. It results in a fair quality of life, with a high degree of independence of the patient. (Neth Heart J 2007;15:45-50.).

7.
Anaesthesia ; 62(4): 405-8, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17381580

RESUMO

We describe a patient with type 2N von Willebrand's disease scheduled for elective coronary artery bypass graft for severe three-vessel coronary artery disease with involvement of the left main stem. He was given a pre-operative bolus of 3000 IU factor VIII/Willebrand factor concentrate (approximately 40 IU.kg(-1)), followed by a continuous infusion of 3 IU.h(-1) (228 IU.h(-1)) before undergoing coronary surgery with full heparinisation and cardiopulmonary bypass. There were no intra-operative bleeding complications and only one unit of packed red blood cells was required postoperatively. Thromboprophylaxis with low-molecular weight heparin and aspirin was given and the infusion of factor VIII/von Willebrand factor concentrate continued for 2 days. As a result of haematological monitoring, heparin therapy was changed from prophylactic to therapeutic on day 5-6 and stopped on day 7.


Assuntos
Perda Sanguínea Cirúrgica/prevenção & controle , Ponte de Artéria Coronária/métodos , Assistência Perioperatória/métodos , Doenças de von Willebrand/complicações , Idoso , Anticoagulantes/uso terapêutico , Fator VIII/uso terapêutico , Humanos , Masculino , Doenças de von Willebrand/tratamento farmacológico , Fator de von Willebrand/uso terapêutico
8.
Neth Heart J ; 14(12): 425-430, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25696585

RESUMO

Heart transplantation is limited by the lack of donor organs. Twenty years after the start of the Dutch transplant programmes in Rotterdam and Utrecht the situation has even worsened, despite efforts to increase the donor pool. The Dutch situation seems to be worse than in other surrounding countries, and several factors that may influence donor organ availability and organ utilisation are discussed. The indications and contraindications for heart transplantation are presented, which are rather restrictive in order to select optimal recipients for the scarce donor hearts. Detailed data on donor hearts, rejected for transplantation, are shown to give some insight into the difficult process of dealing with marginal donor organs. It is concluded that with the current low numbers of acceptable quality donor hearts, there is no lack of capacity in the two transplanting centres nor is the waiting list limiting the number of transplants. The influence of our current legal system on organ donation, which requires (prior) permission from donor and relatives, is probably limited. The most important determinants of donor organ availability are: 1. The potential donor pool, consisting of brain dead victims of (traffic) accidents and CVAs and 2. Lack of consent to a request for donation. The potential donor pool is remarkably small in the Netherlands, due to relatively low numbers of (traffic) accidents, with an almost equal number of CVA-related brain dead patients compared with neighbouring countries. Lack of consent can only be pushed back by improved public awareness of the importance of donation and improved skills of professionals in asking permission in case there is no previous consent.

9.
Neth Heart J ; 10(6): 267-271, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25696107

RESUMO

OBJECTIVE: To evaluate the use of left ventricular assist devices (LVAD) as bridge to heart transplantation (HTx) in patients with end-stage heart failure. METHOD: Between March 1993 and December 2001, 38 patients with refractory end-stage heart failure underwent HeartMate LVAD (Thoratec, Pleasanton Calif.) implantation. RESULTS: A total of 33 of the 38 patients (87%) survived the implantation and perioperative period. There were five perioperative deaths (13%), two due to right ventricular failure, two as a result of bleeding and one probably due to septic shock at the time of LVAD implantation. Three patients (9%) died late in the postoperative period due to septic shock, mechanical failure of the device and a cerebral embolus resulting from LVAD endocarditis, initiated by an acute cholecystitis. Twelve patients (32%) had one or more infectious episodes during long-term assist, of which one patient died. Four patients are still on the device, waiting for a heart transplantation. Twenty-six patients (76%) underwent HTx after 206±129 days of support. CONCLUSION: These results show the efficacy of LVAD support as a bridge to heart transplantation in patients with end-stage heart failure. Major long-term complications are infections and mechanical failure of the device.

10.
Neth Heart J ; 10(6): 283-285, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25696110

RESUMO

In trying to assess the benefit of cardiac surgery in AIDS patients, the question arises whether a patient with a deficient immune system can tolerate open heart surgery well enough to make the operation worthwhile. Surgical procedures and cardiopulmonary bypass have been noted to alter immune function (Diettrich et al., Ide et al.). Therefore, the presence of clinical AIDS is often still regarded as a contraindication to cardiac surgery. In this report we describe an AIDS patient who developed endocarditis of the native aortic valve. The endocarditis was successfully treated with antibiotic drugs, but the patient was left with damaged valves. Over the months he developed a massive aortic insufficiency and underwent aortic valve replacement. The patient did well after surgery, and is alive and well 18 months after the operation, suggesting that cardiac surgery might be a good and valuable treatment option in AIDS patients.

11.
J Am Coll Cardiol ; 37(7): 1794-9, 2001 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-11401113

RESUMO

OBJECTIVES: We sought to study exercise capacity at different points in time after left ventricular assist device (LVAD) implantation and subsequent heart transplantation (HTx). BACKGROUND: The lack of donor organs warrants alternatives for transplantation. METHODS: Repeat treadmill testing with respiratory gas analysis was performed in 15 men with a LVAD. Four groups of data are presented. In group A (n = 10), the exercise capacities at 8 weeks and 12 weeks after LVAD implantation were compared. In group B (n = 15), the data at 12 weeks are presented in more detail. In group C (n = 9), sequential analysis of exercise capacity was performed at 12 weeks after LVAD implantation and at 12 weeks and one year after HTx. In group D, exercise performance one year after HTx in patients with (n = 10) and without (n = 20) a previous assist device was compared. RESULTS: In group A, peak oxygen consumption (Vo2) increased from 21.3+/-3.8 to 24.2+/-4.8 ml/kg body weight per min (p < 0.003), accompanied by a decrease in peak minute ventilation/ carbon dioxide production (VE/Vco2) (39.4+/-10.1 to 36.3+/-8.2; p < 0.03). In group B, peak Vo2 12 weeks after LVAD implantation was 23.0+/-4.4 ml/kg per min. In group C, levels of peak Vo2 12 weeks after LVAD implantation and 12 weeks and one year after HTx were comparable (22.8+/-5.3, 24.6+/-3.3 and 26.2+/-3.8 ml/kg per min, respectively; p = NS). In group D, there appeared to be no difference in percent predicted peak Vo2 in patients with or without a previous LVAD (68+/-13% vs. 74+/-15%; p < 0.37), although, because of the small numbers, the power of this comparison is limited (0.45 to detect a difference of 10%). CONCLUSIONS: Exercise capacity in patients with a LVAD increases over time; 12 weeks after LVAD implantation, Vo2 is comparable to that at 12 weeks and one year after HTx. Previous LVAD implantation does not seem to adversely affect exercise capacity after HTx.


Assuntos
Teste de Esforço , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Transplante de Coração , Coração Auxiliar , Adulto , Humanos , Masculino , Cuidados Pós-Operatórios , Fatores de Tempo
13.
Transpl Int ; 13 Suppl 1: S216-24, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11111999

RESUMO

The reduction in the frequency of rejection episodes several months after heart transplantation (HTX) correlates with the development of donor-specific nonresponsiveness. This is reflected in a reduced frequency of donor-specific cytotoxic T cells (CTL) in the peripheral blood. We investigated whether the reduced CTL frequency and the incidence of rejection episodes coincided with a change in the frequency of either IL-2- or IL-4-producing helper T lymphocytes (HTL). We measured the frequency of HTL before and at several time points after HTX in the blood of ten recipients, using limiting dilution analysis for IL-2 and IL-4. In most patients, HTL frequencies dropped immediately after transplantation, but returned to pre-HTX values later after transplantation. No consistent decrease or increase in frequencies was observed long after HTX. In contrast to IL-2, the HTL frequencies for IL-4 before transplantation were significantly higher in patients without post-HTX rejection episodes requiring treatment than in patients with such episodes. This phenomenon was observed for the in vitro responses towards both donor and third-party cells. In conclusion, relatively high frequencies of IL-4-producing T cells may have a beneficial effect on the outcome of human heart transplantation, because they are associated with a reduced incidence of rejection episodes after transplantation.


Assuntos
Rejeição de Enxerto/imunologia , Transplante de Coração/imunologia , Interleucina-4/sangue , Linfócitos T Auxiliares-Indutores/imunologia , Biomarcadores/sangue , Rejeição de Enxerto/epidemiologia , Antígenos HLA-A/imunologia , Antígenos HLA-B/imunologia , Antígenos HLA-DR/imunologia , Teste de Histocompatibilidade , Humanos , Incidência , Interleucina-2/sangue , Linfócitos T Citotóxicos/imunologia , Fatores de Tempo , Doadores de Tecidos , Transplante Homólogo
15.
J Heart Lung Transplant ; 18(11): 1031-40, 1999 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10598726

RESUMO

BACKGROUND: Use of a permanent left ventricular assist device (LVAD) has been proposed as an alternate treatment of patients with end-stage heart failure. The purpose of this study was to compare the functional capacity of patients following implantation of a LVAD vs heart transplant (HTx). METHODS: Eighteen patients from 6 centers who received an intracorporeal LVAD as a bridge to HTx underwent treadmill testing 1 to 3 months post-LVAD and again post-HTx. Baseline and peak measurements, including oxygen consumption, blood pressures, and respiratory rate were made during each treadmill test. RESULTS: Peak oxygen consumption was 14.5+/-3.9 ml/kg/minute post-LVAD and 17.5+/-5.0 ml/kg/minute post-HTx (p < .005). The percentage of the predicted peak oxygen consumption based on gender, weight, and age was 39.5%+/-5.5% post-LVAD and 47.7%+/-10.9% post-HTx (p < .005). Exercise duration was lower post-LVAD than post-HTx (10.3+/-4.2 minute vs 12.5+/-5.4 minute, p < .05). After LVAD implantation, peak total oxygen consumption correlated with peak LVAD rate and output. Eight patients reached an LVAD rate of 120 beats per minute (bpm) before the conclusion of exercise, the maximum rate for the outpatient electric device. The peak respiratory exchange ratio post-LVAD was 1.15+/-0.22 and post-HTx was 1.15+/-0.18, consistent with a good effort in both groups. CONCLUSIONS: Patients demonstrated a lower functional capacity post-LVAD than post-HTx. For some patients functional capacity post-LVAD may be improved by a higher maximum LVAD rate and output.


Assuntos
Exercício Físico/fisiologia , Insuficiência Cardíaca/fisiopatologia , Transplante de Coração , Coração Auxiliar , Adulto , Idoso , Pressão Sanguínea , Teste de Esforço , Feminino , Insuficiência Cardíaca/metabolismo , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio , Estudos Prospectivos , Implantação de Prótese/instrumentação , Respiração , Resultado do Tratamento
16.
Ned Tijdschr Geneeskd ; 143(32): 1664-8, 1999 Aug 07.
Artigo em Holandês | MEDLINE | ID: mdl-10494303

RESUMO

A 32-year-old woman underwent heart transplantation after having suffered two myocardial infarctions, the first when parturition was pharmacologically induced, the second during diagnostic catheterization. Three years after the heart transplantation she became pregnant three times. In the first two pregnancies therapeutic abortion was performed because of trisomy-21. The third pregnancy was uneventful until week 36. At that time labour was induced because of signs of pre-ecclampsia. A healthy boy was born with normal physical and psychological development after four years. In pregnancy after heart transplantation teratogenic effects of the medication have not been described. The main problems are hypertension and pre-eclampsia in the mother and prematurity and low birth weight in the newborn. A major problem is the limited life expectancy after heart transplantation due to which a patient will only rarely see his or her child grow up into adulthood.


Assuntos
Transplante de Coração/efeitos adversos , Imunossupressores/efeitos adversos , Complicações Cardiovasculares na Gravidez/etiologia , Gravidez de Alto Risco/efeitos dos fármacos , Adulto , Feminino , Humanos , Hipertensão/etiologia , Recém-Nascido de Baixo Peso , Recém-Nascido , Trabalho de Parto Induzido , Masculino , Pré-Eclâmpsia/etiologia , Gravidez , Resultado da Gravidez
17.
J Cardiothorac Vasc Anesth ; 13(2): 123-9, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10230942

RESUMO

OBJECTIVE: To describe hemodynamic alterations during coronary artery bypass grafting (CABG) without extracorporeal circulation using the Octopus Tissue Stabilizer, and to describe the two anesthetic management protocols based on either general anesthesia with opioids (34 patients) or general anesthesia with high thoracic epidural anesthesia (TEA; 66 patients). DESIGN: A prospective observational report. SETTING: An academic university heart center. PARTICIPANTS: First 100 patients undergoing CABG using the Octopus Tissue Stabilizer. INTERVENTIONS: None. MAIN RESULTS: Current management provided satisfactory results in preventing hypoperfusion of the heart and inadequate systemic circulation without the use of major pharmacologic interventions. Movement of the heart to reach the target site of anastomosis caused hemodynamic alterations. These could easily be corrected by anesthetic interventions, such as fluid load and low doses of inotropes. High TEA allows earlier extubation compared with the opioid anesthesia technique (0.9 v 4.5 hours). Perioperative management and the incidence of postoperative complications did not differ between anesthetic techniques. Major complications, such as death, intraoperative myocardial infarction, and stroke, did not occur. CONCLUSION: Both anesthetic protocols are safe and effective in handling these patients. Off-pump CABG surgery requires anesthetic interventions because hemodynamic alterations are caused by the presentation of the heart to the surgeon. The complication rate is low but needs to be evaluated, compared with conventional CABG, in a prospective randomized study. High thoracic epidural anesthesia allows early recovery, but improved outcome could not be proved in this patient group.


Assuntos
Ponte de Artéria Coronária/instrumentação , Sucção/instrumentação , Adjuvantes Anestésicos/administração & dosagem , Anastomose Cirúrgica , Anestesia Epidural/métodos , Anestesia Geral/métodos , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/métodos , Circulação Coronária/fisiologia , Desenho de Equipamento , Feminino , Hidratação , Hemodinâmica/fisiologia , Humanos , Incidência , Intubação Intratraqueal , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Contração Miocárdica/efeitos dos fármacos , Contração Miocárdica/fisiologia , Entorpecentes/administração & dosagem , Estudos Prospectivos , Segurança , Resultado do Tratamento
18.
NMR Biomed ; 12(8): 515-24, 1999 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-10668044

RESUMO

A reliable, sensitive, non-invasive alternative for transvenous endomyocardial biopsy in detecting cardiac allograft rejection is desirable for optimal management of heart transplant patients. To establish whether (31)P magnetic resonance spectroscopy can become a non-invasive tool for detecting cardiac allograft rejection, the cardiac high-energy phosphate metabolism of human heart transplants was serially examined in 13 patients by means of (31)P MRS from post-operative day 13 to day 294, and compared with histologic evaluation of endomyocardial biopsies. Biopsy scores of 2 or higher, according to the Working Formulation criteria of Billingham et al., were considered to indicate rejection. Logistic regression, which was corrected for differences between the individual patients and the time after transplantation, showed no significant correlation between the occurrence of histologically detected rejection and the PCr:ATP ratio. However, using an analysis of variance, the PCr:ATP ratios of non-rejecting cases obtained within 50 days after transplantation (mean: 27 +/- 11 days) appeared to be significantly different from those obtained after post-operative day 50 [0.95 +/- 0.17 (n = 25) vs 1.17 +/- 0.17 (n = 32), mean +/- SD; p < 0.01]. No significant difference was observed between the PCr:ATP ratios obtained 100 days after transplantation (mean: 162 +/- 52 days) and the PCr:ATP ratios in the hearts of healthy volunteers [1.18 +/- 0. 18 (n = 19) and 1.23 +/- 0.17 (n = 6), mean +/- SD, respectively; p = 0.55]. The PCr:ATP ratio in transplanted human hearts is not a sensitive indicator for the detection of early acute human cardiac allograft rejection. This may be due to a temporarily altered high-energy phosphate metabolism early after transplantation irrespective of rejection.


Assuntos
Metabolismo Energético , Rejeição de Enxerto , Transplante de Coração , Miocárdio/metabolismo , Trifosfato de Adenosina/metabolismo , Adolescente , Adulto , Feminino , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Fosfocreatina/metabolismo , Transplante Homólogo
19.
Ann Thorac Surg ; 66(2): 576-9, 1998 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-9725417

RESUMO

Off-pump coronary artery bypass grafting requires immobilization of the coronary artery. A suction device (Octopus Tissue Stabilizer), attached to the epicardium and connected rigidly to the operating table rail, was used through limited and full surgical access for single-vessel and multivessel arterial revascularization, respectively. An outline for its application, as used by us to construct 122 anastomoses in 70 patients, including posterior wall grafting (in 9 patients) and sequential grafting on the anterior wall (in 17 patients), is presented.


Assuntos
Ponte de Artéria Coronária/instrumentação , Anastomose Cirúrgica/instrumentação , Humanos , Esterno/cirurgia , Toracotomia/instrumentação
20.
J Thorac Cardiovasc Surg ; 116(1): 60-7, 1998 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9671898

RESUMO

OBJECTIVE: Cardiopulmonary bypass and global cardiac arrest enable safe coronary artery bypass grafting but have adverse effects. In off-pump coronary bypass grafting, invasiveness is reduced, but anastomosis suturing is jeopardized by cardiac motion. Therefore the key to successful off-pump coronary bypass grafting is effective local cardiac wall stabilization. METHODS: We prospectively assessed the safety and efficacy of the Octopus tissue stabilizer (Medtronic, Inc., Minneapolis, Minn.) in the first 100 patients selected for off-pump coronary bypass via full or limited surgical access. To immobilize and expose the coronary artery, two suction paddles (-400 mm Hg), fixed to the operating table-rail by an articulating arm, stabilized the anastomosis site. RESULTS: One hundred forty-one grafts (96% arterial) were used to create 172 anastomoses (17% side-to-side), up to 4 per patient, on average 23 in the full access group (46 patients) and 1.2 in the limited access group (54 patients). Complications included conversion to cardiopulmonary bypass (2%), conversion from limited to full access (3%), myocardial infarction (4%), predischarge coronary reintervention (2%), and late coronary reintervention (1%). Median postoperative length of hospital stay was 4 days (limited access) or 5 days (full access). Rapid recovery allowed 96% of patients to resume social activities within 1 month. At the 6-month angiographic follow-up, 95% of anastomoses was patent. At the 2- to 22-month follow-up (mean, 13 months), 98 patients were in Canadian Cardiovascular Society class I and 2 patients were in class II. CONCLUSION: These results suggest that off-pump coronary artery bypass grafting with the Octopus tissue stabilizer is safe. Early clinical outcome and patency rates warrant a randomized study comparing this methods with conventional coronary bypass grafting.


Assuntos
Ponte Cardiopulmonar , Ponte de Artéria Coronária/métodos , Doença das Coronárias/cirurgia , Contraindicações , Angiografia Coronária , Doença das Coronárias/complicações , Doença das Coronárias/diagnóstico por imagem , Eletrocardiografia , Desenho de Equipamento , Teste de Esforço , Feminino , Seguimentos , Humanos , Masculino , Complicações Pós-Operatórias , Estudos Prospectivos , Segurança , Técnicas de Sutura , Resultado do Tratamento , Disfunção Ventricular Esquerda/complicações