1.
Sensors (Basel) ; 12(12): 16390-403, 2012 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-23443384

RESUMO

There are two critical parameters for microbolometers: the temperature coefficient of resistance (TCR) of the sensing material, and the thermal conductance of the insulation structure. Cytochrome c protein, having a high TCR, is a good candidate for infrared detection. We can use SU-8 photoresist for the thermal insulation structure, given its low thermal conductance. In this study, we designed a platform structure based on a SU-8 photoresist. We fabricated an infrared sensing pixel and recorded a high TCR for this new structure. The SU-8 photoresist insulation structure was fabricated using the exposure dose method. We experimentally demonstrated high values of TCR from 22%/K to 25.7%/K, and the measured noise was 1.2 × 10(-8) V2/Hz at 60 Hz. When the bias current was 2 µA, the calculated voltage responsivity was 1.16 × 10(5) V/W. This study presents a new kind of microbolometer based on cytochrome c protein on top of an SU-8 photoresist platform that does not require expensive vacuum deposition equipment.


Assuntos
Citocromos c/química , Compostos de Epóxi/química , Polímeros/química , Propriedades de Superfície , Raios Infravermelhos