Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Perinatol ; 2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37714181

RESUMO

OBJECTIVE: Comprehensive assessment of hemodynamic significance of a patent ductus arteriosus (PDA) is a common indication to perform targeted neonatal echocardiography (TNE). Impact of implementation of such an assessment on PDA management decisions remains to be reported. The objective of this study is to compare PDA-related hemodynamic information and PDA treatment decisions before and after introduction of TNE service. STUDY DESIGN: This was a retrospective cohort study at a tertiary level neonatal intensive care unit in Southwestern Ontario. We investigated two time periods: Epoch-1 (non-TNE 2013-2016) versus Epoch-2 (TNE 2018-2021). We included neonates < 32 weeks with PDA. Data on baseline clinical characteristics, PDA-related echocardiographic parameters, PDA treatment details, and relevant long-term outcomes were collected. Primary outcome was defined as PDA treatment rates and need for multiple courses. Secondary outcomes included availability of PDA hemodynamic data and neonatal mortality/morbidity (PDA-related) RESULTS: A total of 275 neonates were included. A total of 162 were assessed by conventional echocardiography in Epoch-1, whereas 113 were assessed by TNE in Epoch-2. Baseline clinical characteristics were similar. Epoch-2 had more echocardiographic assessments per patient of 2.7 (±1.8) versus 1.9 (± 1.3), p < 0.001 in Epoch1. The mean postnatal age at first echocardiographic assessment was higher in Epoch-2 (12.7 days [ ± 14.6]) than in Epoch-1 (7.9 days [ ± 10.4]), p < 0.001. Comprehensive hemodynamic assessment of PDA-related echocardiographic parameters such as PDA size, shunt pattern, effect on systemic circulation, and pulmonary circulation were higher in Epoch-2. Overall, PDA treatment rates were comparable in the two time periods. The use of multiple courses of treatment was higher in Epoch-1 than in Epoch-2 (47.8 vs. 31.7%, p = 0.047). In Epoch-1, neonates received PDA treatment earlier than in Epoch-2. CONCLUSION: With the implementation of the TNE service, increased echocardiographic evaluations per patient were completed with availability of more comprehensive hemodynamic information about PDA. PDA treatment rates were similar in the two epochs, but need for multiple courses were less in TNE era. KEY POINTS: · TNE allows comprehensive hemodynamic assessment of PDA.. · Implementation of dedicated TNE service led to increased use of echocardiography to assess PDA.. · Standardized hemodynamic assessment of PDA may allow improved individualization of treatment need..

3.
Neoreviews ; 23(7): e486-e496, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35773505

RESUMO

The assessment of systemic blood flow is a complex and comprehensive process with clinical, laboratory, and technological components. Despite recent advancements in technology, there is no perfect bedside tool to quantify systemic blood flow in infants that can be used for clinical decision making. Each option has its own merits and limitations, and evidence on the reliability of these physiology-based assessment processes is evolving. This article provides an extensive review of the interpretation and limitations of methods to assess systemic blood flow in infants, highlighting the importance of a comprehensive and multimodal approach in this population.


Assuntos
Circulação Sanguínea , Humanos , Lactente , Recém-Nascido
4.
J Clin Ultrasound ; 50(3): 385-392, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35218035

RESUMO

OBJECTIVE: The early abnormal pulmonary vasoreactivity observed in babies at risk of Bronchopulmonary dysplasia (BPD) increases the pulmonary vascular resistance. This can be assessed non-invasively using Time to Peak Velocity:Right Ventricular Ejection Time ratio (TPV:RVET) measured from pulmonary artery Doppler waveform obtained using echocardiogram. We postulate that screening for this early can predict BPD in this cohort. The objective of the study was to determine the utility of TPV:RVET in early prediction of BPD in Extremely Low Birth Weight (ELBW) babies born less than 1250grams Birth Weight. METHODS: This was a single-center retrospective cohort study of ELBW babies born<29 weeks over 4 year period who had echocardiogram between 7-21 days of life. TPV:RVET ratio was measured from pulmonary artery Doppler waveform obtained using echocardiogram. The main outcome was BPD at 36 weeks corrected gestation. The predictive ability of TPV:RVET (cut off 0.34) for subsequent development of BPD was analyzed using ROC. RESULTS: Of 589 ELBW<29 weeks, 207 babies were eligible. BPD was found in 60.4%. The TPV:RVET at 0.34 had sensitivity 76.8% (95%CI 68.4-83.9), specificity 85.4% (95%CI 75.8-92.2), positive predictive value 88.9% (95%CI 81.4-94.1), negative predictive value 70.7% (95%CI 60.7-79), and ROC area 0.811 (95%CI 0.757-0.864). Odds ratio of having BPD for TPV:RVET at 0.34 was 19.9 (95%CI 8.19-48.34) and increased by 1.07 (95%CI 1.05-1.09) with every additional days of mechanical ventilation. TPV:RVET ratio had 92.75% inter-observer agreement with kappa 0.83. CONCLUSION: TPV:RVET ratio is a good and reliable early screening tool for subsequent development of BPD in ELBW babies with substantial inter-observer agreement.


Assuntos
Displasia Broncopulmonar , Displasia Broncopulmonar/diagnóstico por imagem , Displasia Broncopulmonar/prevenção & controle , Humanos , Lactente , Recém-Nascido de Peso Extremamente Baixo ao Nascer , Recém-Nascido , Artéria Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Resistência Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...