Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Bone Joint Surg Br ; 92(12): 1700-2, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21119178

RESUMO

Systemic capillary leak syndrome, or the Clarkson syndrome, is an extremely rare condition in which increased capillary permeability results in a massive shift of fluid into the extravascular space. This is followed rapidly by hypotensive shock, haemoconcentration, and, potentially, substantial oedema of the limbs resulting in an acute compartment syndrome. It is important for orthopaedic surgeons to be aware of this syndrome as our medical colleagues, who initially care for these patients, are less familiar with the diagnosis and the need for emergency management of the associated compartment syndrome should it develop. There have been fewer than 100 cases of this entity reported. This case report is the first to describe the subsequent development of a compartment syndrome in all four limbs. Clinical vigilance and continuous monitoring of intracompartmental pressure is necessary in these patients in order to help reduce limb-threatening complications.


Assuntos
Síndrome de Vazamento Capilar/complicações , Síndromes Compartimentais/etiologia , Biomarcadores/sangue , Síndrome de Vazamento Capilar/diagnóstico , Diagnóstico Diferencial , Humanos , Masculino , Pessoa de Meia-Idade
2.
Artigo em Inglês | MEDLINE | ID: mdl-19680968

RESUMO

Human exposure to bisphenol A (BPA) has recently received special attention. It has been shown that exposure to BPA may occur through the consumption of beverages or foods that have been in contact with polycarbonate (PC) plastic containers or epoxy resins in food packaging. A BPA migration study was conducted using a variety of plastic containers, including polycarbonate baby bottles, non-PC baby bottles, baby bottle liners, and reusable PC drinking bottles. Water was used to simulate migration into aqueous and acidic foods; 10% ethanol solution to simulate migration to low- and high-alcoholic foods; and 50% ethanol solution to simulate migration to fatty foods. By combining solid-phase extraction, BPA derivatization and analysis by GC-EI/MS/MS, a very low detection limit at the ng l(-1) level was obtained. Migration of BPA at 40 degrees C ranged from 0.11 microg l(-1) in water incubated for 8 h to 2.39 microg l(-1) in 50% ethanol incubated for 240 h. Residual BPA leaching from PC bottles increased with temperature and incubation time. In comparison with the migration observed from PC bottles, non-PC baby bottles and baby bottle liners showed only trace levels of BPA. Tests for leachable lead and cadmium were also conducted on glass baby bottles since these represent a potential alternative to plastic bottles. No detectable lead or cadmium was found to leach from the glass. This study indicated that non-PC plastic baby bottles, baby bottle liners and glass baby bottles might be good alternatives for polycarbonate bottles.


Assuntos
Estrogênios não Esteroides/análise , Contaminação de Alimentos/análise , Embalagem de Alimentos , Fenóis/análise , Cimento de Policarboxilato/análise , Compostos Benzidrílicos , Alimentação com Mamadeira , Utensílios de Alimentação e Culinária , Humanos , Lactente , Recém-Nascido , Limite de Detecção , Fenóis/química , Cimento de Policarboxilato/química , Esterilização/métodos , Temperatura , Água/análise , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...