Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
ANZ J Surg ; 93(12): 2958-2963, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37953528

RESUMO

BACKGROUND: Postoperative stiffness affects up to 20% of patients following arthroscopic rotator cuff repair. Recent evidence indicates that early postoperative stiffness may associated with lower retear rates. This study aimed to identify the independent predictors of early postoperative stiffness. METHODS: A retrospective cohort study of 1526 rotator cuff repairs was performed. Range of motion at 6-week postop was used to identify stiff patients. Stiffness was defined as external rotation <27.5o or forward flexion <145o . Multiple logistic regression analysis was used to identify the independent predictors of 6-week stiffness. RESULTS: The independent predictors for external rotation stiffness at 6-week postop were more recent cases (Wald = 60), restricted preoperative external rotation (Wald = 36), younger age (Wald = 21) and poorer surgeon-ranked tissue quality (Wald = 15). The independent predictors for forward flexion stiffness were more recent cases (Wald = 101), restricted preoperative forward flexion (Wald = 16) and external rotation (Wald = 13) and female patients (Wald = 12). All patients that developed early postoperative stiffness had recovered range of motion by 6 months to preoperative levels (P < 0.0001). A significantly greater proportion of younger patients (40-49) developed postoperative stiffness when compared to older patients aged 50-59 (P < 0.0062), 70-79 (P < 0.0126) and 80-89 (P < 0.004). Patients that retore had significantly greater average 6-week postoperative range of motion. CONCLUSIONS: Patients earlier in the study were found to have greater postoperative range of motion, which coincided with a more aggressive rehabilitation program with less immobilization. Thus, the data supports the hypothesis that a temporary period of shoulder stiffness facilitates tendon repair and ultimately a better outcome post rotator cuff repair.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Humanos , Feminino , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/cirurgia , Estudos Retrospectivos , Articulação do Ombro/cirurgia , Resultado do Tratamento , Artroscopia , Amplitude de Movimento Articular
2.
Orthop J Sports Med ; 11(6): 23259671231175883, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37347026

RESUMO

Background: The addition of onlay biological grafts to augment difficult rotator cuff repairs has shown encouraging results in a case series. Purpose/Hypothesis: The purpose of this study was to determine whether the addition of an onlay bioinductive implant would improve repair integrity, shear wave elastographic appearance of the repaired tendon and patch, and patient-rated and/or surgeon-measured shoulder function when used in workers' compensation patients undergoing revision arthroscopic rotator cuff repair. We hypothesized that the addition of the bioinductive implant would enhance repair integrity and clinical outcomes compared with standard repair. Study Design: Cohort study; Level of evidence, 3. Methods: A post hoc matched-cohort study was conducted on prospectively recruited workers' compensation patients who received a bioinductive implant for revision rotator cuff repair (n = 19). The control group was selected from consecutive workers' compensation revision rotator cuff repair patients before the introduction of bioinductive implants. Then, they were matched for age and tear size (n = 32). Kaplan-Meier curves were generated to compare the primary outcome of repair integrity between groups. The secondary outcomes were to evaluate the elastographic appearance of the tendon and patch in the bioinductive implant group and to compare patient-rated and surgeon-measured shoulder function between groups preoperatively and at 1 week, 6 weeks, 3 months, and 6 months postoperatively. Results: No major complications associated with the bioinductive implants were identified. Six months after the revision rotator cuff repair, the retear rate in the bioinductive implant group was 16% (3/19), compared with 19% (6/32) in the age- and tear size-matched control group (P = .458). At the final follow-up, the retear rate in the bioinductive implant group was 47% (9/19) at a mean of 14 months compared with 38% (12/32) at a mean of 29 months in the control group (P = .489). The shear wave elastographic stiffness of repaired tendons augmented with the bioinductive implant remained unchanged at 6 m/s from 1 week to 6 months postoperatively, which is lower than the stiffness of 10 m/s in healthy tendons. There were no significant differences in patient-rated or surgeon-measured outcomes between groups 6 months postoperatively. Conclusion: There were no differences in repair integrity or clinical outcomes between workers' compensation patients who underwent revision arthroscopic rotator cuff repair with an onlay bioinductive implant compared to those who underwent standard revision rotator cuff repair.

3.
JSES Int ; 7(3): 450-463, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37266179

RESUMO

Background: The most common complication of arthroscopic rotator cuff repair is retear, which is more common in larger tears and older patients. We hypothesized that the quality of the torn tendon is important in protecting against retear. Surgeons have traditionally assessed the quality of repaired tendons with a four-point Likert scale. Shear Wave Elastography Ultrasound (SWEUS) is a recent technological advancement that can quantify soft-tissue stiffness. This study aimed to determine how closely a surgeon's intraoperative ranking of tissue quality during rotator cuff repair correlated to postoperative supraspinatus tendon stiffness measured by SWEUS. Methods: This was a prospective case series on 50 patients undergoing arthroscopic rotator cuff repair, involving SWEUS measurements of each patient's supraspinatus tendon at 8 days, 6 weeks, 12 weeks, 6 months, and 12 months. The intraoperative surgeon score of tissue quality for each patient was ranked on a four-point Likert scale. Each patient's scores were compared to postoperative SWEUS velocity measurements of the supraspinatus tendon postrepair. Results: The SWEUS determined stiffness of supraspinatus tendons at their repaired insertion site postrepair increased by 22% from 6.3 ± 0.2 m/s to 7.7 ± 0.3 m/s over 12 months as the tendons healed (P = .0001). Supraspinatus tendon stiffness was greater in patients with smaller tears (r = -0.50, P = .001) and of younger age (r = -0.58, P = .00001). Surgeons also consistently rated younger patients (rs = -0.49, P = .0001) and smaller tears (rs = -0.56, P = .00001) as having superior intraoperative tendon quality. The correlations between SWEUS velocity and surgeon tissue quality rankings were modest at best and strongest at 12 weeks (rs = 0.27, P = .04). There were modest associations between SWEUS tendon stiffness and surgeon tendon mobility rankings at 6 weeks (rs = 0.26, P = .04) and repair quality rankings at 12 months (rs = 0.36, P = .02). Conclusions: These data support the finding that machines (SWEUS) are better at assessing torn rotator cuff tendon quality and whether that tendon will heal after repair than the 'person' performing the surgery. Supraspinatus tendons lose stiffness as they get older and when the tear is larger, likely explaining why retear post-cuff repair is more common with advanced age and larger tears.

4.
J Clin Med ; 12(7)2023 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-37048790

RESUMO

BACKGROUND: Superior capsular reconstruction (SCR) for massive, irreparable rotator cuff tears involves anchoring a graft between the superior glenoid and the greater tuberosity of the humerus. Optimizing the graft size is important. We aimed (1) to evaluate the reliability of plain film radiography in determining graft size for SCR and (2) to create a database to help predict future graft sizes. METHODS: An inter- and intra-rater reliability trial was conducted on 10 and 6 subjects with healthy shoulders, respectively, using plain film radiography to measure the distance between the superior glenoid and the supraspinatus footprint. The subjects were positioned upright with an abduction pillow modified to hold the shoulder at 30° abduction and 45° external rotation, afterwhich a true antero-posterior shoulder radiograph was captured. Thirty subjects were recruited for the database and grouped using the aforementioned protocol. RESULTS: The inter-rater and intra-rater trial agreement was excellent, with intraclass correlation coefficients of 0.94 (95% CI) and 0.76 (95% CI), respectively. Three medio-lateral patch sizes, of 33 mm, 38 mm, and 47 mm, were proposed based on the protocol in 30 subjects. CONCLUSIONS: Plain film radiography demonstrated excellent reliability in measuring the distance between the superior glenoid and the supraspinatus footprint. Three ordinal patch sizes are proposed.

5.
J Clin Med ; 12(5)2023 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-36902675

RESUMO

Arthroscopic rotator cuff repairs have been reported to take between 72 and 113 min to complete. This team has adopted its practice to reduce rotator cuff repair times. We aimed to determine (1) what factors reduced operative time, and (2) whether arthroscopic rotator cuff repairs could be performed in under 5 min. Consecutive rotator cuff repairs were filmed with the intent of capturing a <5-min repair. A retrospective analysis of prospectively collected data of 2232 patients who underwent primary arthroscopic rotator cuff repair by a single surgeon was performed using Spearman's correlations and multiple linear regression. Cohen's f2 values were calculated to quantify effect size. Video footage of a 4-min arthroscopic repair was captured on the 4th case. Backwards stepwise multivariate linear regression found that an undersurface repair technique (f2 = 0.08, p < 0.001), fewer surgical anchors (f2 = 0.06, p < 0.001), more recent case number (f2 = 0.01, p < 0.001), smaller tear size (f2 = 0.01, p < 0.001), increased assistant case number (f2 = 0.01, p < 0.001), female sex (f2 = 0.004, p < 0.001), higher repair quality ranking (f2 = 0.006, p < 0.001) and private hospital (f2 = 0.005, p < 0.001) were independently associated with a faster operative time. Use of the undersurface repair technique, reduced anchor number, smaller tear size, increased surgeon and assistant surgeon case number, performing repairs in a private hospital and female sex independently lowered operative time. A <5-min repair was captured.

6.
J Ultrasound Med ; 42(8): 1799-1808, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36851879

RESUMO

OBJECTIVES: How the material properties of the human supraspinatus tendon change following arthroscopic rotator cuff repair is undetermined. Shear wave elastography ultrasound is a relatively new, noninvasive measure of tissue stiffness. We aimed to evaluate any temporal changes in stiffness and/or thickness of supraspinatus tendons in humans following primary arthroscopic rotator cuff repair. METHODS: Shear wave elastography was performed at three predetermined regions by a single sonographer at 1-, 6-, 12-, 24-, and 52 weeks postoperatively in 50 consecutive single-row inverted mattress primary arthroscopic rotator cuff repairs. One-way ANOVA with Tukey's correction and Spearman's correlation tests was performed. RESULTS: Of 50 patients, two retore by 1-week and were excluded. Two patients retore at 6 weeks, two at 12 weeks, and one at 24 weeks. The mean tendon stiffness in 48 patients at the tendon footprint increased by 21% (1.32 m/s) at 6 months (P < .001), with the lateral tendon stiffening before the medial tendon. Tendon thickness decreased by 11% (0.6 mm) at 6 weeks (P = .008), then stabilized to 24 weeks. Tendons that were less elastographically stiff at 1 week were more likely to be thinner at 6-weeks (r = .38, P = .010). CONCLUSIONS: The data supports the hypothesis that rotator cuff tendons repaired using the single-row inverted-mattress technique take 6 weeks to heal to bone. Unlike in other tendons, there was no hypertrophic healing response. Prior to 6 weeks, the tendon may stretch/thin-out, particularly if its material properties, as assessed by shear wave elastography, are inferior. The material properties of the tendon improved at the tendon insertion site first, then medially out to 12 months post-repair.


Assuntos
Técnicas de Imagem por Elasticidade , Lesões do Manguito Rotador , Humanos , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Tendões , Artroscopia/métodos , Técnicas de Imagem por Elasticidade/métodos , Resultado do Tratamento
7.
J Shoulder Elbow Surg ; 32(6): e319-e327, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36740010

RESUMO

BACKGROUND: The main complication of rotator cuff repair is retear, which is most common in older patients and patients with greater tear sizes. However, it is unknown why these factors are associated with increased rates of retear. The aim of this study was to determine whether the factors associated with rotator cuff retear (age, tear size, sex, history of trauma, and duration of symptoms) are also associated with decreased mechanical stiffness of the supraspinatus tendon after repair, as assessed by shear wave elastography. METHODS: This was a prospective study of 50 patients undergoing primary rotator cuff repair. A sonographer conducted shear wave elastography ultrasound in all patients at 1, 6, 12, 26, and 52 weeks after repair. The shear wave velocity of the supraspinatus tendon was measured at the tendon-bone interface, 3 mm medial to the interface, and 6 mm medial to the interface. A multiple linear regression analysis was performed with calculation of Cohen F2 values to determine the factors that independently affected supraspinatus tendon stiffness postoperatively. RESULTS: For every decade increase in age, the shear wave velocity of the supraspinatus tendon decreased by 0.5 m/s (P = .004). Greater tear size correlated with reduced supraspinatus shear wave velocity (P < .03 at 6 weeks). Male patients had greater supraspinatus tendon stiffness than female patients (8.2 m/s vs. 6.9 m/s, P = .04). Tendons in patients with a history of trauma were approximately 16% stiffer postoperatively than those in patients with no trauma history (P < .001). Duration of symptoms had no impact on the mechanical stiffness of the supraspinatus tendon. CONCLUSION: Older age, larger tear size, female sex, and nontraumatic tear causation were independently associated with reduced shear wave velocity of the supraspinatus tendon postoperatively. The findings of our study correlate with the results of cohort studies assessing the influence of these variables on rotator cuff retear rates, suggesting that the mechanical stiffness of the supraspinatus tendon, as assessed by shear wave elastography, may have an important association with a successful repair.


Assuntos
Técnicas de Imagem por Elasticidade , Lacerações , Lesões do Manguito Rotador , Humanos , Masculino , Feminino , Idoso , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Técnicas de Imagem por Elasticidade/métodos , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Estudos Prospectivos , Tendões , Ruptura
8.
HSS J ; 19(1): 44-52, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36776506

RESUMO

Background: Superior capsule reconstruction (SCR) is an option for the treatment of massive, irreparable rotator cuff tears. However, which materials yield the strongest constructs remains undetermined. Purposes: We sought to investigate whether SCR with polytetrafluoroethylene (PTFE) or human dermal allograft (HDA), 2 or 3 glenoid anchors, and suture or minitape resulted in better failure load properties at the patch-glenoid interface. Methods: We conducted a biomechanical study in 30 glenoid-sided SCR repairs in Sawbones models divided into 5 groups. Each was pulled to failure to assess mode of failure, peak load (N), stiffness (N/mm), yield load (N), peak energy (N m), and ultimate energy (N m). The 5 groups were as follows: group 1-PTFE, 2 anchors, and suture; group 2-PTFE, 2 anchors, and minitape; group 3-HDA, 2 anchors, and suture; group 4-HDA, 2 anchors, and minitape; group 5-PTFE, 3 anchors, and minitape. Results: Repairs failed by button-holing of suture/minitape. Group 5 had greater peak load, stiffness, yield load, and peak energy (384 ± 62 N; 24 ± 3 N/mm; 343 ± 42 N; 4 ± 2 N m) than group 3 (226 ± 67 N; 16 ± 4 N/mm; 194 ± 74 N; 2 ± 1 N m) or group 4 (274 ± 62 N; 17 ± 4 N/mm; 244 ± 50 N; 2 ± 1 N m) and greater ultimate energy (8 ± 3 N m) than all other groups. Conclusions: This biomechanical study of SCR repairs in Sawbones models found that yield load was greater in PTFE than HDA, 3 anchors were better than 2, and minitape was no better than suture.

9.
Am J Sports Med ; 51(4): 893-900, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36803077

RESUMO

BACKGROUND: It is undetermined which factors predict return to work after arthroscopic rotator cuff repair. PURPOSE: To identify which factors predicted return to work at any level and return to preinjury levels of work 6 months after arthroscopic rotator cuff repair. STUDY DESIGN: Case-control study; Level of evidence, 3. METHODS: Multiple logistic regression analysis of prospectively collected descriptive, preinjury, preoperative, and intraoperative data from 1502 consecutive primary arthroscopic rotator cuff repairs, performed by a single surgeon, was performed to identify independent predictors of return to work at 6 months postoperatively. RESULTS: Six months after arthroscopic rotator cuff repair, 76% of patients had returned to work, and 40% had returned to preinjury levels of work. Return to work at 6 months was likely if patients were still working after their injuries but before surgery (Wald statistic [W] = 55, P < .0001), were stronger in internal rotation preoperatively (W = 8, P = .004), had full-thickness tears (W = 9, P = .002), and were female (W = 5, P = .030). Patients who continued working postinjury but presurgery were 1.6 times more likely to return to work at any level at 6 months compared to patients who were not working (P < .0001). Patients who had a less strenuous preinjury level of work (W = 173, P < .0001), worked at a mild to moderate level post injury but presurgery, had greater preoperative behind-the-back lift-off strength (W = 8, P = .004), and had less preoperative passive external rotation range of motion (W = 5, P = .034) were more likely to return to preinjury levels of work at 6 months postoperatively. Specifically, patients who worked at a mild to moderate level postinjury but presurgery were 2.5 times more likely to return to work than patients who were not working, or who were working strenuously postinjury but presurgery (p < 0.0001). Patients who nominated their preinjury level of work as "light" were 11 times more likely to return to preinjury levels of work at 6 months compared to those who nominated it as "strenuous" (P < .0001). CONCLUSION: Six months after rotator cuff repair, patients who continued to work after injury but presurgery were the most likely to return to work at any level, and patients who had less strenuous preinjury levels of work were the most likely to return to their preinjury levels of work. Greater preoperative subscapularis strength independently predicted return to work at any level and to preinjury levels.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador , Humanos , Feminino , Masculino , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/cirurgia , Resultado do Tratamento , Estudos de Casos e Controles , Retorno ao Trabalho , Estudos Retrospectivos , Artroscopia , Amplitude de Movimento Articular
10.
ANZ J Surg ; 93(3): 649-655, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36627775

RESUMO

BACKGROUND: Interposition graft rotator cuff repair is one option for the treatment of massive, otherwise irreparable rotator cuff tears. It is undetermined how different suturing techniques influence morphology at the patch-tendon interface in interposition rotator cuff repairs, particularly with respect to increased cross-sectional area at the repair site post-exposure to cyclic loading, which may influence healing. We aimed to analyze how the morphology of the grafts used in polytetrafluoroethylene (PTFE) interposition rotator cuff repairs differed according to whether the graft was secured using the multiple mattress technique or the weave technique respectively. METHODS: Twelve PTFE interposition rotator cuff repairs (two groups, n = 6) were cyclically loaded. The thickness, width, cross-sectional area at the individual patches and at the repair site, and patch elongation were compared between repairs using the 'multiple mattress' technique and repairs that used the 'weave' technique. RESULTS: At all loads, repair site cross-sectional area and thickness was greater in the weave group than in the multiple mattress group (P<0.05), despite repair site width being greater in the multiple mattress group (P<0.05). No significant differences in elongation were found between the multiple mattress and weave groups. CONCLUSION: Greater repair site cross-sectional area under cyclic loading was observed in polytetrafluoroethylene interposition rotator repairs that used the weave technique than in those that used the multiple mattress technique. Increased repair site cross-sectional area in the weave group occurred due to increased thickness and decreased width relative to the multiple mattress group. No differences in cross-sectional area were found between groups at the individual patches.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador , Humanos , Manguito Rotador/cirurgia , Fenômenos Biomecânicos , Lesões do Manguito Rotador/cirurgia , Tendões/cirurgia , Técnicas de Sutura , Politetrafluoretileno
11.
Am J Sports Med ; 51(2): 343-350, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36637166

RESUMO

BACKGROUND: Pain is a common presentation after glenohumeral labral injuries. However, the source of that pain is undetermined. PURPOSE/HYPOTHESIS: We aimed to determine if there is a differential expression of nerve fibers around the glenoid labrum and if torn labra have increased neuronal expression compared with untorn labra (rotator cuff repair labra). We hypothesized that the superior labrum would have a higher concentration of neurofilament than would the rest of the labrum and that the concentration of neurofilament would increase at the site of a labral tear. STUDY DESIGN: Descriptive laboratory study. METHODS: Seven labra were sampled at the 3-, 5-, 9-, and 12-o'clock positions during total shoulder arthroplasty. Samples were also collected at the 3-, 5-, and 12-o'clock positions during rotator cuff repair (16 labra), anterior labral repair (6 labra), type II superior labral anterior to posterior (SLAP) repair (4 labra), and capsular release for idiopathic capsulitis (5 labra). Sections were immunostained with antibodies to neurofilament, a specific neuronal marker that is used to identify central and peripheral nerve fibers, and the concentration and intensity of immunostained-positive cells assessed. RESULTS: The concentration of neurofilament staining was similar in the superior, anterior, posterior, and inferior glenoid labrum in untorn labra (8 neurofilament expressing cells per square millimeter; P = .3). Torn labra exhibited a 3- to 4-fold increase in neuronal expression, which was isolated to the location of the tear in SLAP (P = .09) and anterior labral tears (P = .02). The concentration of neurofilament expressing cells in torn glenoid labrum samples was comparable that in with the glenoid labrum of adhesive capsulitis samples (P = .7). CONCLUSION: This study supports the hypothesis that after a tear of the anterior or superior labrum the labrum in that region becomes populated with new nerves fibers and that these fibers may be responsible for the pain noted by patients with superior (SLAP) and/or anterior labral (Bankart) tears. CLINICAL RELEVANCE: This study suggests that neural infiltration contributes to the pain experienced by patients with labral tears. It may help with patient education and direct future management of labral lesions.


Assuntos
Lacerações , Lesões do Manguito Rotador , Lesões do Ombro , Articulação do Ombro , Humanos , Lesões do Manguito Rotador/patologia , Lesões do Ombro/patologia , Filamentos Intermediários , Articulação do Ombro/cirurgia , Ruptura/patologia , Lacerações/patologia , Dor
12.
J Clin Orthop Trauma ; 36: 102081, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36479505

RESUMO

Background: It is undetermined how effective superior capsule/capsular reconstruction (SCR) is, and which factors influence clinical outcomes. Questions/purposes: (1) To identify which factors influence outcomes in SCR, (2) to evaluate the effect of graft integrity on clinical outcomes, and (3) to compare SCR to other procedures for irreparable rotator cuff tears. Methods: PubMed and EMBASE databases were searched for clinical SCR studies. Data on specific factors that influenced outcomes, that compared outcomes between intact/torn graft groups, or compared SCR to alternative treatments for irreparable tears were extracted by two investigators. Random-effects meta-analysis was performed to compare outcomes between intact vs torn SCR grafts. Results: 394 articles were identified. 100 full-text articles were screened. 13 studies were included for scoping review. Eight studies were meta-analyzed. Better clinical scores were found in younger patients, with intact/repairable subscapularis, without acetabulization/arthritis, who played sports. In patients with irreparable tears without arthritis, SCR produced similar clinical scores at 2 years as shoulder arthroplasty and partial infraspinatus repair, and greater improvements in ASES and Constant scores than latissimus dorsi tendon transfer. Intact grafts produced better VAS (mean difference [MD] = 0.97, 95% confidence interval [-1.45-0.50], P < 0.0001, I 2 = 67%, n [patients] = 261), ASES (MD = 8.29, [2.89-13.70], P = 0.003, I 2 = 74%, n = 281), external rotation (MD = 4.49, [0.36-8.61], P = 0.03, I 2 = 0%, n = 240), and acromiohumeral distance (MD = 2.45, [0.96-3.94], P = 0.001, I 2 = 92%, n = 260) than torn grafts. Conclusions: Patients who underwent SCR for irreparable rotator cuff tears were more likely to have better clinical outcomes if they were younger, had intact/repairable subscapularis, without acetabulization/arthritis, played sports and had intact grafts.

13.
J Shoulder Elbow Surg ; 32(4): 713-728, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36481456

RESUMO

BACKGROUND: Ultrasound is commonly used to assess rotator cuff repair (RCR), but no standardized criterion exists to characterize the tendon. PURPOSE: The aims of this study were to (1) develop content validity for ultrasound specific criteria to grade the postoperative appearance of a tendon after RCR, (2) assess the reliability of the criteria, and (3) assess the feasibility to use these assessments. METHODOLOGY: Following expert consultation and literature review for content validity, 2 scales were created: 1) the Fibrillar matrix, Echogenicity, Contour, Thickness, and Suture (FECTS) scale and 2) the Rotator Cuff Repair-Investigator Global Assessment (RCR-IGA). A prospective cohort study was undertaken on patients who had received a RCR and serial B-mode ultrasound images. Four raters assessed the 64-ultrasound images using the scales created in a blinded fashion using intraclass correlation coefficients. RESULTS: The FECTS scale was a composite score with 5 key parameters and the RCR-IGA scale was a 5-point global score. The intrarater reliability for the FECTS scale was excellent for the most experienced rater (0.92) and fair for the rater with no experience (0.72). The intrarater reliability for the RCR-IGA scale was excellent for 3 of the 4 raters (0.80-0.87) and fair when used by the least experienced rater (0.56). Inter-rater testing for all the FECTS scale parameters had excellent reliability (0.82-0.92) except for Fibrillar matrix (0.73). The average time to complete the FECTS scale per image was 23 seconds and 11 seconds for the RCR-IGA scale. CONCLUSION: The FECTS scale and the RCR-IGA scale are reliable tools to assess the ultrasonic appearance of the repaired rotator cuff tendon. The FECTS scale was more reliable for less experienced assessors. The RCR-IGA scale was easier, more time efficient and reliable for those with experience.


Assuntos
Lesões do Manguito Rotador , Humanos , Artroscopia/métodos , Imunoglobulina A , Estudos Prospectivos , Reprodutibilidade dos Testes , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Suturas , Resultado do Tratamento , Ultrassonografia
14.
J Shoulder Elbow Surg ; 32(3): e106-e116, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36183896

RESUMO

BACKGROUND: Treating massive and irreparable rotator cuff tears are problematic. Several studies have reported that polytetrafluoroethylene (PTFE) patches demonstrated excellent construct integrity and positive clinical and patient outcomes. However, these studies either had small sample sizes or short follow-up periods. PURPOSE: To determine the survivorship, efficacy, and medium-term (2-19 years) outcomes of PTFE patch repairs. METHODS: This retrospective study used prospectively collected data to establish the medium-term outcomes of PTFE interposition patch repairs for massive rotator cuff tears that could not be repaired by the standard technique. Patients included those who met the ≥2-year follow-up criteria post repair. Standardized assessments of patient-ranked shoulder pain and function and shoulder strength and passive range of motion (ROM) were performed preoperatively and at follow-up visits. Radiographs and ultrasonography were used to evaluate repair integrity, measure proximal humeral head migration, and determine glenohumeral arthritis scores. RESULTS: Forty-one shoulders formed the study cohort at a mean follow-up period of 5 years (range: 2-19 years). The mean age of this group was 72 (standard deviation: 10; range: 50-88) and had 14 cm2 tears at surgery. Twenty-five of 41 (61%) PTFE interposition patch repairs remained intact at an average of 5 years postrepair. Thirteen patches failed at the patch-tendon junction, 1 was removed, and 2 patients underwent reverse total shoulder replacement. Patient-ranked shoulder stiffness (P < .05), frequency of pain during activity and sleep (P < .001), pain levels during overhead activity and rest (P < .001), and overall shoulder function significantly improved from bad preoperatively to fair at the mean 5-year postoperative visit (P < .001). No significant improvements were demonstrated in dynamometer-measured shoulder strength maneuvers and passive ROM. All patients demonstrated proximal humeral head migration on shoulder radiographs regardless of repair integrity (mean Upper Migration Index = 1.2). Failed repairs were associated with higher mean preoperative glenohumeral arthritis grades compared with intact repairs (grade 2 in failed repairs compared with grade 1 in intact repairs) (P < .01). CONCLUSION: PTFE interposition patch repairs for massive and irreparable tears had good construct integrity and clinical outcomes at 2 years. These outcomes were not maintained. PTFE patch repairs often failed at the patch-tendon junction at 4 years and beyond and were ineffective in (1) preventing proximal humeral head migration, (2) stopping progression of glenohumeral arthritis, and (3) improving shoulder strength and ROM.


Assuntos
Artrite , Lesões do Manguito Rotador , Humanos , Lesões do Manguito Rotador/cirurgia , Manguito Rotador/cirurgia , Politetrafluoretileno , Estudos Retrospectivos , Resultado do Tratamento , Dor de Ombro/etiologia , Dor de Ombro/cirurgia , Amplitude de Movimento Articular , Artroscopia/métodos
15.
Orthop J Sports Med ; 10(11): 23259671221136304, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36458108

RESUMO

Background: Reverse total shoulder replacement (RTSR) is becoming a popular and reliable treatment for rotator cuff arthropathy. However, little is known about the ability to participate in sports after surgery. Purpose: To determine to what extent RTSR will allow patients to participate in sporting activities and identify the associated factors that could affect postoperative sports participation. Study Design: Case series; Level of evidence, 4. Methods: Data were collected prospectively from patients who underwent RTSR over a 10-year period from April 2009 to May 2019. Patients were assessed before surgery, at 6 months after surgery, and at the final follow-up. Patients were asked within a validated shoulder questionnaire to rank their current highest level of sports participation, overall shoulder status, frequency of pain, level of pain, and functional levels. Their shoulder range of motion and strength were assessed before surgery and at 6 months after surgery. Results: The study included 108 shoulders (106 patients). The mean age was 74 years (range, 51-88 years), with 44 men and 64 women. The mean follow-up was 4 years. Overall shoulder satisfaction, frequency and levels of pain, and shoulder function improved significantly at 6 months and 4 years (P < .0001). External rotation, abduction, and forward flexion range of motion improved significantly at 6 months (P < .05 for all). The strength of internal rotation, external rotation, abduction, and adduction improved significantly at 6 months (P < .001 for all). The rate of return to sports was 67% at 6 months and 48% at 4 years. Multiple significantly associated factors were identified with return to sports at 6 months, including sex and age. Conclusion: The rate of return to sports after RTSR is high. Around two-thirds of patients can return to sports at 6 months postoperatively, although the results slightly deteriorate over time (48% at 4 years).

16.
Shoulder Elbow ; 14(5): 515-522, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36199504

RESUMO

Background: The management of superior labrum anterior to posterior (SLAP) tears is somewhat controversial. It is unclear if the length of time between symptom onset and surgery affects SLAP repair outcomes. Methods: Sixty-one SLAP repairs were retrospectively reviewed pre-operatively and post-operatively at 1, 6, 24 weeks, and > 2 years post-surgery. Patients were allocated to an 'early repair' or 'late repair' group based on time between symptom onset and surgery. Results: Of the 61 patients, 22 patients had surgery within six months of symptom onset. Pre-operatively, 'late repair' patients played a higher level of sport than 'early repair' patients prior to injury. Post-operatively, both groups had similar outcomes up to six months, though at six months 'early repair' patients reported a higher level of work than 'late repair' patients (p = 0.01). At > 2 years after surgery, 'early repair' patients had reduced pain and difficulty with overhead activities (p = 0.002), less stiffness (p = 0.001) and were more satisfied than 'late repair' patients (p = 0.04). Conclusions: Up to six months post-operatively, the time between symptom onset and surgery has limited effect on functional outcomes. However, at > 2 years after surgery, earlier repairs ( < 6 months) are interestingly associated with better functional outcomes. Further studies are required to determine if this is a causal relationship.

17.
JSES Int ; 6(4): 615-622, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35813148

RESUMO

Background: Shoulder pain and loss of function are classically associated with rotator cuff tears, while paresthesia of the hand is not. We noted anecdotally that paresthesia of the arm was common in patients presenting with rotator cuff tears. The purpose of this study was to determine the prevalence and magnitude of hand paresthesia, its relationship to pain, and how surgery affected these symptoms. Methods: This prospective cross-sectional study assessed the prevalence and magnitude of shoulder pain and hand numbness and tingling (as assessed by 2 questions from the modified Boston Carpal Tunnel Questionnaire) preoperatively and at 1 week, 6 weeks, 12 weeks, and 6 months postoperatively among 213 consecutive patients who presented for and underwent arthroscopic rotator cuff repair. Results: The preoperative levels of prevalence and severity of shoulder pain during rest, overhead activities, and sleep improved by 52%, 22%, and 34%, respectively, compared with those by 6 months postoperatively (P < .05). Seventy-five patients (33%) reported hand paresthesia before surgery. There was a 50% and 60% reduction in the severity of hand tingling and numbness, respectively, by 1 week after surgery (P < .05). The preoperative level of hand numbness (Wald statistic; W = 20) and whether the patient's shoulder problem was caused by a specific injury (W = 6) were predictive of the presence of hand numbness at 6 months after surgery (P < .05). Conclusion: This study showed that many patients who undergo rotator cuff repairs present with hand paresthesia that is associated with their shoulder pain. The prevalence and severity of shoulder pain and hand numbness and tingling improved postoperatively.

18.
Shoulder Elbow ; 14(1 Suppl): 71-75, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35845619

RESUMO

Introduction: Rotator cuff tendons are typically reattached to the proximal humerus using transosseous sutures or suture anchors. Their primary mode of failure is at the tendon-bone interface. Methods: We investigated the addition of an adhesive, gelatin-resorcin-formalin (GRF) glue, to a single-row rotator cuff repair (RCR) on ex vivo sheep models. We hypothesised the addition of GRF glue would increase the repair construct strength. The study consisted of three groups of six sheep infraspinatus tendons with an inverted-mattress stitch, tension-band configuration. Group 1 was the control group where no glue was applied. Group 2 involved applying 2 × 2 cm of GRF glue to the infraspinatus footprint and a 2-min curing time. Group 3 allowed for a 15-min cure time. Results: Failure occurred at the tendon-bone-suture interface in 6/6 of the control group, and 4/6 from groups 2 and 3. Failure occurred via the suture pulling out of the anchor in 2/6 of groups 2 and 3. No significant differences were noted between all three groups in ultimate failure load, repair stiffness or total energy to failure (p > 0.05). Discussion: The addition of GRF glue to the tendon-bone-suture interface did not enhance RCR strength in an ovine model.

19.
Orthop J Sports Med ; 10(6): 23259671221105080, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35747364

RESUMO

Background: Favorable outcomes have been reported regarding postoperative shoulder pain and function after repair of anteroinferior (Bankart) glenohumeral labral tears. However, the outcomes of patients after repair of isolated superior labral anterior-posterior (SLAP) tears are a contentious topic. The authors have also anecdotally noted that patients evaluated with labral tears complained of numbness and tingling in their ipsilateral hand. Purpose: To determine if there is a difference in the temporal outcomes of shoulder pain and hand paresthesia in patients with SLAP tears versus Bankart tears after arthroscopic repair. Study Design: Cohort study; Level of evidence, 3. Methods: Included were 66 consecutive patients who underwent arthroscopic labral repair at a single institution between August 2018 and February 2021. The prevalence and magnitude of shoulder pain as well as numbness and tingling of the hand were assessed using questions from the L'Insalata Shoulder Questionnaire and the Boston Carpal Tunnel Questionnaire preoperatively and at 1 week, 6 weeks, 12 weeks, and 6 months after surgery. Results: Preoperatively, patients with SLAP lesions reported a higher prevalence of shoulder pain during sleep compared with those with Bankart tears (P < .05). Postoperatively, patients who underwent SLAP repair reported a larger proportion and more severe magnitude of shoulder pain during rest, overhead activities, and sleep compared with those who underwent Bankart repair (P < .05). Only patients who underwent Bankart repair reported improvements in the prevalence and magnitude of their shoulder pain during rest, overhead activities, and sleep by 6 months postoperatively compared with preoperative levels (P < .05). Preoperatively, 30% of patients with Bankart repairs and 40% of patients with SLAP repairs reported hand tingling, while 35% and 50%, respectively, reported hand numbness. The prevalence and magnitude of hand tingling and numbness were not significantly different between groups at any time point. Conclusion: Study results indicated that patients who underwent SLAP repair experienced worse shoulder pain outcomes compared with those who underwent Bankart repair using the same anchor and surgical technique. Only patients who underwent Bankart repair reported improvements in their hand numbness after surgery. Therefore, labral tear location does matter with respect to shoulder pain and hand numbness.

20.
Shoulder Elbow ; 14(2): 123-134, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35265177

RESUMO

Background: Traumatic anterior shoulder dislocations can cause bony defects of the anterior glenoid rim and are often associated with recurrent shoulder instability. For large glenoid defects of 20-30% without a mobile bony fragment, glenoid reconstruction with bone grafts is often recommended. This review describes two broad categories of glenoid reconstruction procedures found in literature: coracoid transfers involving the Bristow and Latarjet procedures, and free bone grafting techniques. Methods: An electronic search of MEDLINE and PubMed was conducted to find original articles that described glenoid reconstruction techniques or modifications to existing techniques. Results: Coracoid transfers involve the Bristow and Latarjet procedures. Modifications to these procedures such as arthroscopic execution, method of graft attachment and orientation have been described. Free bone grafts have been obtained from the iliac crest, distal tibia, acromion, distal clavicle and femoral condyle. Conclusion: Both coracoid transfers and free bone grafting procedures are options for reconstructing large bony defects of the anterior glenoid rim and have had similar clinical outcomes. Free bone grafts may offer greater flexibility in graft shaping and choice of graft size depending on the bone stock chosen. Novel developments tend towards minimising invasiveness using arthroscopic approaches and examining alternative non-rigid graft fixation techniques.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...