Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 128(8): 081802, 2022 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-35275665

RESUMO

The PROSPECT and STEREO collaborations present a combined measurement of the pure ^{235}U antineutrino spectrum, without site specific corrections or detector-dependent effects. The spectral measurements of the two highest precision experiments at research reactors are found to be compatible with χ^{2}/ndf=24.1/21, allowing a joint unfolding of the prompt energy measurements into antineutrino energy. This ν[over ¯]_{e} energy spectrum is provided to the community, and an excess of events relative to the Huber model is found in the 5-6 MeV region. When a Gaussian bump is fitted to the excess, the data-model χ^{2} value is improved, corresponding to a 2.4σ significance.

2.
Phys Rev Lett ; 128(6): 061801, 2022 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-35213177

RESUMO

Different extensions of the standard model of particle physics, such as braneworld or mirror matter models, predict the existence of a neutron sterile state, possibly as a dark matter candidate. This Letter reports a new experimental constraint on the probability p for neutron conversion into a hidden neutron, set by the STEREO experiment at the high flux reactor of the Institut Laue-Langevin. The limit is p<3.1×10^{-11} at 95% C.L. improving the previous limit by a factor of 13. This result demonstrates that short-baseline neutrino experiments can be used as competitive passing-through-walls neutron experiments to search for hidden neutrons.

3.
Phys Rev Lett ; 125(20): 201801, 2020 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-33258621

RESUMO

We report a measurement of the antineutrino rate from the fission of ^{235}U with the STEREO detector using 119 days of reactor turned on. In our analysis, we perform several detailed corrections and achieve the most precise single measurement at reactors with highly enriched ^{235}U fuel. We measure an IBD cross section per fission of σ_{f}=(6.34±0.06[stat]±0.15[sys]±0.15[model])×10^{-43} cm^{2}/fission and observe a rate deficit of (5.2±0.8[stat]±2.3[sys]±2.3[model])% compared to the model, consistent with the deficit of the world average. Testing ^{235}U as the sole source of the deficit, we find a tension between the results of lowly and highly enriched ^{235}U fuel of 2.1 standard deviations.

4.
Phys Rev Lett ; 121(16): 161801, 2018 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-30387650

RESUMO

The reactor antineutrino anomaly might be explained by the oscillation of reactor antineutrinos toward a sterile neutrino of eV mass. In order to explore this hypothesis, the STEREO experiment measures the antineutrino energy spectrum in six different detector cells covering baselines between 9 and 11 m from the compact core of the ILL research reactor. In this Letter, results from 66 days of reactor turned on and 138 days of reactor turned off are reported. A novel method to extract the antineutrino rates has been developed based on the distribution of the pulse shape discrimination parameter. The test of a new oscillation toward a sterile neutrino is performed by comparing ratios of cells, independent of absolute normalization and of the prediction of the reactor spectrum. The results are found to be compatible with the null oscillation hypothesis and the best fit of the reactor antineutrino anomaly is excluded at 97.5% C.L.

5.
Cochlear Implants Int ; 16(4): 195-200, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24593762

RESUMO

OBJECTIVE: The aim of this study was to compare a cochlear implant electrode array loaded with dexamethasone (DXM) with a conventional passive electrode array for the preservation of residual hearing in gerbils. METHODS: Thirty Mongolian gerbils (Meriones unguiculatus) were implanted with an eluting electrode loaded with DXM (1 and 10%) on one side and a conventional passive electrode on the other side. Hearing thresholds were determined by tone bursts auditory brainstem responses at 4-6 weeks post-implantation and 1-year post-implantation for older gerbils. RESULTS: After 4-6 weeks post-implantation, residual hearing was statistically more preserved with electrode arrays loaded with DXM, regardless of concentration, for the frequencies 16 000 Hz (P = 0.0008), 4000 Hz (P = 0.0038), 1000 Hz (P = 0.0349), and 500 Hz (P = 0.0030). After 1 year, the difference in favor of the DXM+ electrode array was found statistically significant only for the frequency 16 000 Hz (P = 0.0103) but against it for the frequencies 1000 Hz (P = 0.0368) and 500 Hz (P = 0.0010). CONCLUSION: Electrode array with prolonged release of DXM improved short-term preservation of residual hearing after implantation for the frequencies 500, 1000, 4000, and 16 000 Hz in gerbils. The long-term results at 1 year confirmed these data for higher frequencies, but must be verified for the lower frequencies of 500 and 1000 Hz.


Assuntos
Implante Coclear/instrumentação , Dexametasona/administração & dosagem , Eletrodos Implantados , Glucocorticoides/administração & dosagem , Audição/efeitos dos fármacos , Animais , Limiar Auditivo/fisiologia , Implante Coclear/métodos , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Gerbillinae
6.
Radiat Prot Dosimetry ; 161(1-4): 245-8, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24594906

RESUMO

In order to measure the energy and fluence of neutron fields, in the energy range of 8 to 1 MeV, a new primary standard is being developed at the Institute for Radioprotection and Nuclear Safety (IRSN). This project, Micro Time Projection Chamber (µ-TPC), carried out in collaboration with the Laboratoire de Physqique Subatomique et de Cosmologie (LPSC), is based on the nucleus recoil detector principle. The measurement strategy requires track reconstruction of recoiling nuclei down to a few kiloelectronvolts, which can be achieved using a micro-pattern gaseous detector. A gas mixture, mainly isobutane, is used as an n-p converter to detect neutrons within the detection volume. Then electrons, coming from the ionisation of the gas by the proton recoil, are collected by the pixelised anode (2D projection). A self-triggered electronics system is able to perform the anode readout at a 50-MHz frequency in order to give the third dimension of the track. Then, the scattering angle is deduced from this track using algorithms. The charge collection leads to the proton energy, taking into account the ionisation quenching factor. This article emphasises the neutron energy measurements of a monoenergetic neutron field produced at 127 keV. The fluence measurement is not shown in this article. The measurements are compared with Monte Carlo simulations using realistic neutron fields and simulations of the detector response. The discrepancy between experiments and simulations is 5 keV mainly due to the calibration uncertainties of 10 %.


Assuntos
Nêutrons , Proteção Radiológica/instrumentação , Radiometria/instrumentação , Algoritmos , Calibragem , Eletrônica , Desenho de Equipamento , França , Gases , Íons , Método de Monte Carlo , Prótons , Doses de Radiação , Radiometria/métodos , Espalhamento de Radiação , Raios X
7.
Phys Rev Lett ; 111(2): 021301, 2013 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-23889382

RESUMO

We present new experimental constraints on the elastic, spin-dependent WIMP-nucleon cross section using recent data from the XENON100 experiment, operated in the Laboratori Nazionali del Gran Sasso in Italy. An analysis of 224.6 live days×34 kg of exposure acquired during 2011 and 2012 revealed no excess signal due to axial-vector WIMP interactions with 129Xe and 131Xe nuclei. This leads to the most stringent upper limits on WIMP-neutron cross sections for WIMP masses above 6 GeV/c², with a minimum cross section of 3.5×10(-40) cm² at a WIMP mass of 45 GeV/c², at 90% confidence level.

8.
Phys Rev Lett ; 109(18): 181301, 2012 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-23215267

RESUMO

We report on a search for particle dark matter with the XENON100 experiment, operated at the Laboratori Nazionali del Gran Sasso for 13 months during 2011 and 2012. XENON100 features an ultralow electromagnetic background of (5.3 ± 0.6) × 10(-3) events/(keV(ee) × kg × day) in the energy region of interest. A blind analysis of 224.6 live days × 34 kg exposure has yielded no evidence for dark matter interactions. The two candidate events observed in the predefined nuclear recoil energy range of 6.6-30.5 keV(nr) are consistent with the background expectation of (1.0 ± 0.2) events. A profile likelihood analysis using a 6.6-43.3 keV(nr) energy range sets the most stringent limit on the spin-independent elastic weakly interacting massive particle-nucleon scattering cross section for weakly interacting massive particle masses above 8 GeV/c(2), with a minimum of 2 × 10(-45) cm(2) at 55 GeV/c(2) and 90% confidence level.

9.
Phys Rev Lett ; 107(13): 131302, 2011 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-22026838

RESUMO

We present results from the direct search for dark matter with the XENON100 detector, installed underground at the Laboratori Nazionali del Gran Sasso of INFN, Italy. XENON100 is a two-phase time-projection chamber with a 62 kg liquid xenon target. Interaction vertex reconstruction in three dimensions with millimeter precision allows the selection of only the innermost 48 kg as the ultralow background fiducial target. In 100.9 live days of data, acquired between January and June 2010, no evidence for dark matter is found. Three candidate events were observed in the signal region with an expected background of (1.8 ± 0.6) events. This leads to the most stringent limit on dark matter interactions today, excluding spin-independent elastic weakly interacting massive particle (WIMP) nucleon scattering cross sections above 7.0 × 10(-45) cm(2) for a WIMP mass of 50 GeV/c(2) at 90% confidence level.

10.
Phys Rev Lett ; 105(13): 131302, 2010 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-21230760

RESUMO

The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso in Italy, is designed to search for dark matter weakly interacting massive particles (WIMPs) scattering off 62 kg of liquid xenon in an ultralow background dual-phase time projection chamber. In this Letter, we present first dark matter results from the analysis of 11.17 live days of nonblind data, acquired in October and November 2009. In the selected fiducial target of 40 kg, and within the predefined signal region, we observe no events and hence exclude spin-independent WIMP-nucleon elastic scattering cross sections above 3.4 × 10⁻44 cm² for 55 GeV/c² WIMPs at 90% confidence level. Below 20 GeV/c², this result constrains the interpretation of the CoGeNT and DAMA signals as being due to spin-independent, elastic, light mass WIMP interactions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...