Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Virol ; 92: 56-61, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28531553

RESUMO

BACKGROUND: HIV RNA suppression is a key indicator for monitoring success of antiretroviral therapy. From a logistical perspective, viral load (VL) testing using Dried Blood Spots (DBS) is a promising alternative to plasma based VL testing in resource-limited settings. OBJECTIVES: To evaluate the analytical and clinical performance of the Abbott RealTime HIV-1 assay using a fully automated one-spot DBS sample protocol. STUDY DESIGN: Limit of detection (LOD), linearity, lower limit of quantitation (LLQ), upper limit of quantitation (ULQ), and precision were determined using serial dilutions of HIV-1 Virology Quality Assurance stock (VQA Rush University), or HIV-1-containing armored RNA, made in venous blood. To evaluate correlation, bias, and agreement, 497 HIV-1 positive adult clinical samples were collected from Ivory Coast, Uganda and South Africa. For each HIV-1 participant, DBS-fingerprick, DBS-venous and plasma sample results were compared. Correlation and bias values were obtained. The sensitivity and specificity were analyzed at a threshold of 1000 HIV-1 copies/mL generated using the standard plasma protocol. RESULTS: The Abbott HIV-1 DBS protocol had an LOD of 839 copies/mL, a linear range from 500 to 1×107 copies/mL, an LLQ of 839 copies/mL, a ULQ of 1×107 copies/mL, and an inter-assay SD of ≤0.30 log copies/mL for all tested levels within this range. With clinical samples, the correlation coefficient (r value) was 0.896 between DBS-fingerprick and plasma and 0.901 between DBS-venous and plasma, and the bias was -0.07 log copies/mL between DBS-fingerprick and plasma and -0.02 log copies/mL between DBS-venous and plasma. The sensitivity of DBS-fingerprick and DBS-venous was 93%, while the specificity of both DBS methods was 95%. CONCLUSION: The results demonstrated that the Abbott RealTime HIV-1 assay with DBS sample protocol is highly sensitive, specific and precise across a wide dynamic range and correlates well with plasma values. The Abbott RealTime HIV-1 assay with DBS sample protocol provides an alternative sample collection and transfer option in resource-limited settings and expands the utility of a viral load test to monitor HIV-1 ART treatment for infected patients.


Assuntos
Teste em Amostras de Sangue Seco , Infecções por HIV/virologia , HIV-1/fisiologia , RNA Viral/sangue , Carga Viral/métodos , Adulto , Coleta de Amostras Sanguíneas/métodos , Côte d'Ivoire , Infecções por HIV/diagnóstico , Infecções por HIV/epidemiologia , HIV-1/genética , HIV-1/isolamento & purificação , Humanos , Limite de Detecção , Kit de Reagentes para Diagnóstico , Reação em Cadeia da Polimerase em Tempo Real/instrumentação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Sensibilidade e Especificidade , Testes Sorológicos/métodos , África do Sul , Manejo de Espécimes , Carga Viral/instrumentação , Adulto Jovem
2.
Tuberculosis (Edinb) ; 101: 137-143, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27865383

RESUMO

Clinical management of drug-resistant tuberculosis patients continues to present significant challenges to global health. To tackle these challenges, the Abbott RealTime MTB RIF/INH Resistance assay was developed to accelerate the diagnosis of rifampicin and/or isoniazid resistant tuberculosis to within a day. This article summarizes the performance of the Abbott RealTime MTB RIF/INH Resistance assay; including reliability, analytical sensitivity, and clinical sensitivity/specificity as compared to Cepheid GeneXpert MTB/RIF version 1.0 and Hain MTBDRplus version 2.0. The limit of detection (LOD) of the Abbott RealTime MTB RIF/INH Resistance assay was determined to be 32 colony forming units/milliliter (cfu/mL) using the Mycobacterium tuberculosis (MTB) strain H37Rv cell line. For rifampicin resistance detection, the Abbott RealTime MTB RIF/INH Resistance assay demonstrated statistically equivalent clinical sensitivity and specificity as compared to Cepheid GeneXpert MTB/RIF. For isoniazid resistance detection, the assay demonstrated statistically equivalent clinical sensitivity and specificity as compared to Hain MTBDRplus. The performance data presented herein demonstrate that the Abbott RealTime MTB RIF/INH Resistance assay is a sensitive, robust, and reliable test for realtime simultaneous detection of first line anti-tuberculosis antibiotics rifampicin and isoniazid in patient specimens.


Assuntos
Antituberculosos/farmacologia , Isoniazida/farmacologia , Mycobacterium tuberculosis/isolamento & purificação , Rifampina/farmacologia , Tuberculose Resistente a Múltiplos Medicamentos/diagnóstico , Tuberculose Pulmonar/diagnóstico , Antituberculosos/uso terapêutico , Contagem de Colônia Microbiana , Farmacorresistência Bacteriana Múltipla/genética , Humanos , Isoniazida/uso terapêutico , Testes de Sensibilidade Microbiana/métodos , Mutação , Mycobacterium tuberculosis/efeitos dos fármacos , Mycobacterium tuberculosis/crescimento & desenvolvimento , Rifampina/uso terapêutico , Sensibilidade e Especificidade , Manejo de Espécimes/métodos , Tuberculose Resistente a Múltiplos Medicamentos/tratamento farmacológico , Tuberculose Resistente a Múltiplos Medicamentos/microbiologia , Tuberculose Pulmonar/tratamento farmacológico , Tuberculose Pulmonar/microbiologia
3.
Tuberculosis (Edinb) ; 95(5): 613-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26119174

RESUMO

Nucleic acid amplification test (NAAT)-based assays provide fast and sensitive results compared to conventional TB tests. The performance of the new Abbott Molecular MTB assay for the qualitative detection of MTB complex using the automated m2000™ system or manual sample preparation is summarized in this paper. The assay detects eight MTB complex subspecies. The observed limit of detection (LOD) when used to test an MTB H37Rv panel was 2.45 colony forming units (cfu)/mL, while the claimed assay LOD with this MTB strain is 17 cfu/mL. No cross reactivity, or carryover were observed in the study. The clinical sensitivity of the assay was 93% overall; 99% in smear positive, culture positive specimens, and 81% in smear negative, culture positive samples. The clinical specificity was 97%. The inhibition rate in the study was 0.34%. The data suggest that Abbott RealTime MTB is a reliable, robust and sensitive assay for the molecular detection of MTB.


Assuntos
Técnicas Bacteriológicas , DNA Bacteriano/genética , Sequenciamento de Nucleotídeos em Larga Escala , Mycobacterium tuberculosis/genética , Técnicas de Amplificação de Ácido Nucleico , Tuberculose Pulmonar/diagnóstico , Contagem de Colônia Microbiana , Humanos , Limite de Detecção , Mycobacterium tuberculosis/classificação , Mycobacterium tuberculosis/isolamento & purificação , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Escarro/microbiologia , Tuberculose Pulmonar/microbiologia
4.
J Virol Methods ; 115(2): 207-15, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14667537

RESUMO

The LCx HCV RNA quantitative assay (Abbott Laboratories, North Chicago, IL) is designed to use competitive reverse transcriptase-polymerase chain reaction (RT-PCR) and microparticle enzyme immunoassay (MEIA), in combination with a modified Qiagen sample preparation method, to measure the level of hepatitis C virus (HCV) in human plasma and serum. The assay provides quantitative results in international units (IU) of HCV RNA/ml, in copies of HCV RNA/ml, or their log (base 10) equivalents. A conversion study determined that 1IU equals 4.3 copies. The LCx HCV assay detected HCV RNA transcripts representative of genotypes 1-6 with near equal efficiency. The assay did not cross-react with high concentrations of 21 potentially cross-reactive microorganisms or with 100 HCV-negative specimens. The lower limit of detection was demonstrated to be 23IU/ml. The LCx assay had similar sensitivity to the Roche Amplicor HCV (version 2.0) qualitative assay when used to test panels containing 6, 12, 23, and 47IU/ml. The assay linear range was shown to extend from 23 to 2.3millionIU/ml. The intra-assay standard deviation (S.D.) was < or =0.066 logIU/ml for the four HCV positive samples tested, while for the same samples the observed inter-assay S.D. was < or =0.075 logIU/ml. The overall mean assay quantitation value for seven HCV-positive WHO-standardized Acrometrix NAP linearity panel members was within 0.06 logIU/ml of the mean assigned value. The assay was demonstrated to correlate acceptably against the Roche Amplicor HCV monitor test (version 2.0). These data suggest that the assay is standardized appropriately against the WHO standard across its linear range and can be used for quantitation of HCV. In addition, with a sensitivity of 23IU/ml, the assay can be used to determine if post-therapy viral clearance has occurred.


Assuntos
Hepacivirus/genética , Hepacivirus/isolamento & purificação , RNA Viral/sangue , RNA Viral/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Virologia/métodos , Reações Cruzadas , Genótipo , Hepacivirus/imunologia , Hepatite C/tratamento farmacológico , Hepatite C/virologia , Humanos , Técnicas Imunoenzimáticas/métodos , Técnicas Imunoenzimáticas/normas , Técnicas Imunoenzimáticas/estatística & dados numéricos , Padrões de Referência , Reação em Cadeia da Polimerase Via Transcriptase Reversa/normas , Reação em Cadeia da Polimerase Via Transcriptase Reversa/estatística & dados numéricos , Sensibilidade e Especificidade , Viremia/tratamento farmacológico , Viremia/virologia , Virologia/normas , Virologia/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA