Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Oral Health ; 23(1): 796, 2023 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-37880662

RESUMO

BACKGROUND: Effective dental plaque removal is essential for oral health. Different toothbrush parameters including head-size, filament-diameter and interdent-height and different brushing movements like horizontal, rotating and vertical may affect plaque removal efficacy. The purpose of the study was to examine plaque removal efficacy of different design parameters of manual toothbrushes. METHODS: Eight manual toothbrushes were tested using a validated robot test to examine efficacy of toothbrush on replicated human teeth. Characteristics tested were: (i) head-size, (ii) filament-diameter, (iii) cutting-height, (iv) hardness, (v) interdental-height. Each test ran five times in horizontal, rotating, vertical movements. Simulated Plaque removal was evaluated using automated plaque planimetry: 30 fields/tooth, 13 areas representing buccal, lingual, proximal tooth sites. The Kolmogorov-Smirnov-test was applied to test tooth surface variables for normal distribution of plaque removal values. Parameters were analysed by independent two-sample t-test to assess mean differences. Where null hypothesis of normality was rejected, the Wilcoxon-Mann-Whitney-U-test was used. RESULTS: Plaque removal was significantly better with toothbrush having smaller head-size (compact vs. full-size); smaller filament-diameter (0.12 mm vs. 0.15 mm); larger cutting-height (12 mm vs. 9 mm); softer filaments (0.15 or 0.18 mm vs. 0.23 mm) and greater interdent-height difference (8.5/11 mm vs. 10/11 mm). CONCLUSIONS: Manual brushes allowing filaments free to flex with longer, softer and/or having a difference in filament length overall removed significantly more simulated plaque as compared to more standard flat trim, stiff brushes with shorter, harder bristles and a larger head size. While limited by the in vitro nature of the study design, this indicates that the advances in toothbrush design can further enhance plaque removal.


Assuntos
Anormalidades Múltiplas , Placa Dentária , Dentes Fusionados , Dente , Humanos , Desenho de Equipamento , Índice de Placa Dentária , Escovação Dentária , Placa Dentária/terapia , Método Simples-Cego
3.
Sci Rep ; 13(1): 3349, 2023 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-36849815

RESUMO

The nervous system of the Asteroidea (starfish or seastar) consists of radial nerve cords (RNCs) that interconnect with a ring nerve. Despite its relative simplicity, it facilitates the movement of multiple arms and numerous tube feet, as well as regeneration of damaged limbs. Here, we investigated the RNC ultrastructure and its molecular components within the of Pacific crown-of-thorns starfish (COTS; Acanthaster sp.), a well-known coral predator that in high-density outbreaks has major ecological impacts on coral reefs. We describe the presence of an array of unique small bulbous bulbs (40-100 µm diameter) that project from the ectoneural region of the adult RNC. Each comprise large secretory-like cells and prominent cilia. In contrast, juvenile COTS and its congener Acanthaster brevispinus lack these features, both of which are non-corallivorous. Proteomic analysis of the RNC (and isolated neural bulbs) provides the first comprehensive echinoderm protein database for neural tissue, including numerous secreted proteins associated with signalling, transport and defence. The neural bulbs contained several neuropeptides (e.g., bombyxin-type, starfish myorelaxant peptide, secretogranin 7B2-like, Ap15a-like, and ApNp35) and Deleted in Malignant Brain Tumor 1-like proteins. In summary, this study provides a new insight into the novel traits of COTS, a major pest on coral reefs, and a proteomics resource that can be used to develop (bio)control strategies and understand molecular mechanisms of regeneration.


Assuntos
Distrofias de Cones e Bastonetes , Tecido Nervoso , Animais , Nervo Radial , Proteômica , Estrelas-do-Mar , Equinodermos
4.
BMC Oral Health ; 22(1): 225, 2022 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-35676648

RESUMO

BACKGROUND: Toothbrushes require flexibility to access all dental surfaces and remove plaque effectively, but they should also aim to prevent or limit overbrushing and consequent damage to teeth and gums. In two studies, the physical properties and cleaning performance of specialist test toothbrushes with flexible necks were compared to a reference rigid-necked toothbrush. METHODS: In Study 1, a universal testing machine (Instron E 10,000) with a specially designed setup was used to test the deflection behaviour of toothbrush head and neck. Untufted toothbrushes were fixed in a custom holder and force was applied to the head while the deflection was measured. In Study 2, one control and five test toothbrushes were assessed using a robot system to simulate the cleaning of artificial plaque from defined surfaces of artificial replicated human teeth in a model oral cavity (typodonts). RESULTS: Study 1 showed that the flexible-neck toothbrush deflected 2 to 2.5 times more than the rigid-neck reference toothbrush when same force was applied to the toothbrush head. Study 2 revealed that all five test toothbrushes showed statistically superior simulated plaque removal to the reference toothbrush. This superiority was observed for all test toothbrushes employing horizontal and rotating brushing action (all p = 0.001) but only three of the five toothbrushes when vertical brushing was employed (all p = 0.001). Cleaning efficacy of the test toothbrushes was demonstrated both interdentally and at the gumline locations. The Complete Protection toothbrush showed the most effective cleaning performance followed by the Repair and Protect and Rapid Relief toothbrushes. CONCLUSION: The addition of a flexible-neck component to the toothbrush designs helped to reduce stiffness and may allow more effective cleaning compared to rigid designs with controlled force distribution on the teeth and gums. This may help to provide plaque control at all potential risk areas in an in vitro robot model and could support good oral hygiene in-use.


Assuntos
Placa Dentária , Robótica , Placa Dentária/prevenção & controle , Índice de Placa Dentária , Desenho de Equipamento , Humanos , Testes Mecânicos , Escovação Dentária
5.
BMC Oral Health ; 14: 82, 2014 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-24996973

RESUMO

BACKGROUND: Clinical validation of laboratory toothbrushing tests has important advantages. It was, therefore, the aim to demonstrate correlation of tooth cleaning efficiency of a new robot brushing simulation technique with clinical plaque removal. METHODS: Clinical programme: 27 subjects received dental cleaning prior to 3-day-plaque-regrowth-interval. Plaque was stained, photographically documented and scored using planimetrical index. Subjects brushed teeth 33-47 with three techniques (horizontal, rotating, vertical), each for 20s buccally and for 20s orally in 3 consecutive intervals. The force was calibrated, the brushing technique was video supported. Two different brushes were randomly assigned to the subject. Robot programme: Clinical brushing programmes were transfered to a 6-axis-robot. Artificial teeth 33-47 were covered with plaque-simulating substrate. All brushing techniques were repeated 7 times, results were scored according to clinical planimetry. All data underwent statistical analysis by t-test, U-test and multivariate analysis. RESULTS: The individual clinical cleaning patterns are well reproduced by the robot programmes. Differences in plaque removal are statistically significant for the two brushes, reproduced in clinical and robot data. Multivariate analysis confirms the higher cleaning efficiency for anterior teeth and for the buccal sites. CONCLUSIONS: The robot tooth brushing simulation programme showed good correlation with clinically standardized tooth brushing.This new robot brushing simulation programme can be used for rapid, reproducible laboratory testing of tooth cleaning.


Assuntos
Placa Dentária/terapia , Robótica , Escovação Dentária/métodos , Adulto , Placa Dentária/patologia , Desenho de Equipamento , Feminino , Humanos , Masculino , Método Simples-Cego , Estresse Mecânico , Dente Artificial , Escovação Dentária/instrumentação , Gravação em Vídeo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...