Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Polymers (Basel) ; 16(10)2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38794563

RESUMO

In this study, electrospun scaffolds were fabricated using polycaprolactone (PCL) loaded with varying concentrations of ß-carotene (1.2%, 2.4%, and 3.6%) via the electrospinning technique. The electrospinning process involved the melting of PCL in acetic acid, followed by the incorporation of ß-carotene powder under constant stirring. Raman spectroscopy revealed a homogeneous distribution of ß-carotene within the PCL matrix. However, the ß-carotene appeared in particulate form, rather than being dissolved and blended with the PCL matrix, a result also confirmed by thermogravimetric analysis. Additionally, X-ray diffraction analysis indicated a decrease in crystallinity with increasing ß-carotene concentration. Mechanical testing of the scaffolds demonstrated an increase in ultimate strain, accompanied by a reduction in ultimate stress, indicating a potential plasticizing effect. Moreover, antimicrobial assays revealed a marginal antibacterial effect against Escherichia coli for scaffolds with higher ß-carotene concentrations. Conversely, preliminary biological assessment using KUSA-A1 mesenchymal cells indicated enhanced cellular proliferation in response to the scaffolds, suggesting the potential biocompatibility and cell-stimulating properties of ß-carotene-loaded PCL scaffolds. Overall, this study provides insights into the fabrication and characterization of electrospun PCL scaffolds containing ß-carotene, laying the groundwork for further exploration in tissue engineering and regenerative medicine applications.

2.
Anal Methods ; 16(17): 2707-2720, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38629136

RESUMO

In this research, Raman imaging was employed to map various samples, and the resulting data were analyzed using a suite of automated tools to extract critical information, including intensity and signal-to-noise ratio. The acquired spectra were further processed to identify similarities and investigate patterns using principal component analysis. The objective of this study was to establish guidelines for investigating Raman imaging results, particularly when dealing with large datasets comprising thousands of relatively low-intensity spectra. The overall quality of the results was assessed, and representative locations were determined based on the main Raman bands. While automated software solutions are insufficient for removing baselines and fitting the data, statistical analysis proved to be a powerful tool for extracting valuable information directly from the raw spectral data. This approach enables the extraction of as much information as possible from large arrays of spectral data, even in complex cases where automated software may fall short. The findings of this study contribute to enhancing the analysis and interpretation of Raman imaging results, providing researchers with a robust methodology for extracting meaningful insights from complex datasets, reducing the amount of effort required during data interpretation and analysis.


Assuntos
Análise de Componente Principal , Análise Espectral Raman , Análise Espectral Raman/métodos , Software , Humanos , Razão Sinal-Ruído , Algoritmos , Processamento de Imagem Assistida por Computador/métodos
3.
Materials (Basel) ; 17(1)2023 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-38203968

RESUMO

Titanium alloys have emerged as the most successful metallic material to ever be applied in the field of biomedical engineering. This comprehensive review covers the history of titanium in medicine, the properties of titanium and its alloys, the production technologies used to produce biomedical implants, and the most common uses for titanium and its alloys, ranging from orthopedic implants to dental prosthetics and cardiovascular devices. At the core of this success lies the combination of machinability, mechanical strength, biocompatibility, and corrosion resistance. This unique combination of useful traits has positioned titanium alloys as an indispensable material for biomedical engineering applications, enabling safer, more durable, and more efficient treatments for patients affected by various kinds of pathologies. This review takes an in-depth journey into the inherent properties that define titanium alloys and which of them are advantageous for biomedical use. It explores their production techniques and the fabrication methodologies that are utilized to machine them into their final shape. The biomedical applications of titanium alloys are then categorized and described in detail, focusing on which specific advantages titanium alloys are present when compared to other materials. This review not only captures the current state of the art, but also explores the future possibilities and limitations of titanium alloys applied in the biomedical field.

4.
Materials (Basel) ; 15(19)2022 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-36234109

RESUMO

The effect of post-processing heat treatment on the corrosion behavior of AISI 316L stainless steel manufactured by laser powder bed fusion (L-PBF) is investigated in this work. Produced stainless steel was heat treated in a broad temperature range (from 200 °C to 1100 °C) in order to evaluate the electrochemical behavior and morphology of corrosion. The electrochemical behavior was investigated by potentiodynamic and galvanostatic polarization in a neutral and acidic (pH 1.8) 3.5% NaCl solution. The microstructure modification after heat treatment and the morphology of attack of corroded samples were evaluated by optical and scanning electron microscopy. The fine cellular/columnar microstructure typically observed for additive-manufactured stainless steel evolves into a fine equiaxed austenitic structure after thermal treatment at high temperatures (above 800 °C). The post-processing thermal treatment does not negatively affect the electrochemical behavior of additive-manufactured stainless steel even after prolonged heat treatment at 1100 °C for 8 h and 24 h. This indicates that the excellent barrier properties of the native oxide film are retained after heat treatment.

5.
Materials (Basel) ; 14(13)2021 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-34199076

RESUMO

AISI 316L stainless steels are widely employed in applications where durability is crucial. For this reason, an accurate prediction of its behaviour is of paramount importance. In this work, the spotlight is on the cyclic response and low-cycle fatigue performance of this material, at room temperature. Particularly, the first aim of this work is to experimentally test this material and use the results as input to calibrate the parameters involved in a kinematic and isotropic nonlinear plasticity model (Chaboche and Voce). This procedure is conducted through a newly developed calibration procedure to minimise the parameter estimates errors. Experimental data are eventually used also to estimate the strain-life curve, namely the Manson-Coffin curve representing the 50% failure probability and, afterwards, the design strain-life curves (at 5% failure probability) obtained by four statistical methods (i.e., deterministic, "Equivalent Prediction Interval", univariate tolerance interval, Owen's tolerance interval for regression). Besides the characterisation of the AISI 316L stainless steel, the statistical methodology presented in this work appears to be an efficient tool for engineers dealing with durability problems as it allows one to select fatigue strength curves at various failure probabilities depending on the sought safety level.

6.
Data Brief ; 33: 106443, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33195769

RESUMO

Nowadays, advanced metal components with high geometrical complexity can be 3D printed by using the Selective Laser Melting (SLM) technology. Despite SLM resolution and accuracy are generally limited to some tenths of mm, it should be possible to produce finer and more precise details by applying lasers with a small spot diameter. However, to present date the data collected with small laser spot diameters are poor. In this work, experimental data describing the effects of laser power and scan speed on single track formation when applying a small laser spot diameter of 50 µm on Ti6Al4V powder are reported. SEM images and the extracted geometrical data characterizing the obtained single tracks are provided here, as well as their microstructural analysis and microhardness measurements.

7.
RSC Adv ; 9(29): 16819-16830, 2019 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-35516372

RESUMO

In this paper, a 4-ethylphenol-para-phenylenediamine (4EP-pPDA) benzoxazine has been applied and cured on previously anodized AA2024-T3 substrates. The porous surface oxide layers obtained from sulfo-tartaric anodizing appeared to be highly impregnated by the benzoxazine resin, sealing the anodic films. Through rheological, morphological and chemical characterization, the curing process has been identified to be the key step for the impregnation to occur, related to the low viscosity of the 4EP-pPDA benzoxazine attained during thermal curing. Moreover, the typical surface porosity of the anodic layer reappeared after curing, offering a good anchoring to possible top coats. Finally, high and enduring barrier properties of this hybrid organic-inorganic layer have been highlighted through Electrochemical Impedance Spectroscopy (EIS) and correlated with recent results obtained by Molecular Dynamics Simulations (MDS). These barrier properties appeared to be strongly influenced by the curing process parameters, as has been assessed using alternative curing cycles limiting their duration and lowering the curing temperature. Consequently, adapting the curing process enables the optimization of the barrier properties of the system while respecting the dependence of the mechanical properties of the AA2024-T3 substrate on thermal treatment at high temperatures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...