Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Radiology ; 307(2): e220753, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36625744

RESUMO

Background Ultrahigh-field-strength MRI at 7 T may permit superior visualization of noninflammatory wrist pathologic conditions, particularly due to its high signal-to-noise ratio compared with the clinical standard of 3 T, but direct comparison studies are lacking. Purpose To compare the subjective image quality of 3-T and 7-T ultrahigh-field-strength wrist MRI through semiquantitative scoring of multiple joint tissues in a multireader study. Materials and Methods In this prospective study, healthy controls and participants with chronic wrist pain underwent 3-T and 7-T MRI (coronal T1-weighted turbo spin-echo [TSE], coronal fat-suppressed proton-density [PD]-weighted TSE, transversal T2-weighted TSE) on the same day, from July 2018 to June 2019. Images were scored by seven musculoskeletal radiologists. The overall image quality, presence of artifacts, homogeneity of fat suppression, and visualization of cartilage, the triangular fibrocartilage complex (TFCC), and scapholunate and lunotriquetral ligaments were semiquantitatively assessed. Pairwise differences between 3 T and 7 T were assessed using the Wilcoxon signed-rank test. Interreader reliability was determined using the Fleiss kappa. Results In total, 25 healthy controls (mean age, 25 years ± 4 [SD]; 13 women) and 25 participants with chronic wrist pain (mean age, 39 years ± 16; 14 men) were included. Overall image quality (P = .002) and less presence of artifacts at PD-weighted fat-suppressed MRI were superior at 7 T. T1- and T2-weighted MRI were superior at 3 T (both P < .001), as was fat suppression (P < .001). Visualization of cartilage was superior at 7 T (P < .001), while visualization of the TFCC (P < .001) and scapholunate (P = .048) and lunotriquetral (P = .04) ligaments was superior at 3 T. Interreader reliability showed slight to substantial agreement for the detected pathologic conditions (κ = 0.20-0.64). Conclusion A 7-T MRI of the wrist had potential advantages over 3-T MRI, particularly in cartilage assessment. However, superiority was not shown for all parameters; for example, visualization of the triangular fibrocartilage complex and wrist ligaments was superior at 3 T. © RSNA, 2023 Supplemental material is available for this article.


Assuntos
Dor Crônica , Punho , Masculino , Humanos , Feminino , Adulto , Estudos Prospectivos , Reprodutibilidade dos Testes , Articulação do Punho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Artralgia
2.
Orphanet J Rare Dis ; 16(1): 29, 2021 01 14.
Artigo em Inglês | MEDLINE | ID: mdl-33446201

RESUMO

BACKGROUND: Diffuse interstitial lung disease have been described in Neurofibromatosis type 1 (NF1), but its diversity and prevalence remain unknown. The aim of this study was to assess the prevalence and characteristics of (NF1)-associated lung manifestations in a large single-center study using multidetector computed tomography (MDCT) and to evaluate the smoking history, patients' age, genetics, and the presence of malignant peripheral nerve sheath tumors (MPNST) as potential influencing factors for lung pathologies. METHODS: In this retrospective study, 71 patients with NF1 were evaluated for the presence of distinctive lung manifestations like reticulations, consolidations, type of emphysema, pulmonary nodules and cysts. All patients underwent F-18-FDG PET/CT scans, which were reviewed by two experienced radiologists in consensus. Patients' subgroups were formed based on their smoking history (current smokers/previous smokers/never smokers), age (< 12 years, 12-18 years, > 18 years), and presence of MPNST (MPNST/no MPNST). In 57 patients (80%), genetic analysis of sequences coding for the neurofibromin on chromosome 17 was performed, which was correlated with different lung pathologies. RESULTS: Among all NF1 patients (33 ± 14 years, 56% females), 17 patients (24%) were current smokers and 62 patients (87%) were > 18 years old. Pulmonary cysts, nodules, and paraseptal emphysema were the most common pulmonary findings (35%, 32%, 30%). The presence of pulmonary metastases, MPNST and centrilobular emphysema was associated with smoking. Cysts were observed only in adults, whereas no significant correlation between age and all other pulmonary findings was found (p > 0.05). Presence of MPNST was accompanied by higher rates of intrapulmonary nodules and pulmonary metastasis. Neither the presence nor absence of any of the specific gene mutations was associated with any particular lung pathology (p > 0.05). CONCLUSIONS: All pulmonary findings in NF1 patients occurred independently from specific mutation subtypes, suggesting that many NF1 mutations can cause various pulmonary pathologies. The presence of pulmonary metastases, MPNST and centrilobular emphysema was associated with smoking, indicating the value of smoking secession or the advice not to start smoking in NF1 patients as preventive strategy for clinicians. For screening of pulmonary manifestations in NF1 patients, an MDCT besides medical history and physical examination is mandatory in clinical routine.


Assuntos
Neoplasias de Bainha Neural , Neurofibromatose 1 , Adolescente , Adulto , Criança , Feminino , Humanos , Pulmão , Masculino , Tomografia Computadorizada Multidetectores , Neurofibromatose 1/diagnóstico por imagem , Neurofibromatose 1/genética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos
3.
PLoS One ; 15(10): e0240199, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33031418

RESUMO

PURPOSE: Feasibility of a highly reduced-dose lumbar spine CT protocol using iterative reconstruction (IR) in a human cadaver model. MATERIALS AND METHODS: The lumbar spine of 20 human cadavers was repeatedly examined using three different reduced-dose protocols (RDCT) with decreasing reference tube current-exposure time products (RDCT-1: 50 mAs; RDCT-2: 30 mAs; RDCT-3: 10 mAs) at a constant tube voltage of 140 kV. A clinical standard-dose protocol (SDCT) served as the reference (reference tube current-exposure time product: 70 mAs; tube voltage: 140 kV). Images were reconstructed using filtered back projection (FBP) and two increasing levels of IR: IRL4 and IRL6. A five-point scale was used by two observers to assess the diagnostic quality of anatomical structures (cortical and trabecular bone, intervertebral foramina, pedicles and intervertebral joints, spinous and transverse processes). Objective image noise (OIN) was measured. Results were interpreted using a linear mixed-effects regression model. RESULTS: RDCT-2 with IRL6 (1.2 ± 0.5mSv) was the lowest reduced-dose protocol which provided diagnostically acceptable and equivalent image quality compared to the SDCT (2.3 ± 1.1mSV) with FBP (p > 0.05). All RDCT protocols achieved a significant reduction of the mean (±SD) effective radiation doses (RDCT-1: 1.7±0.9mSv; RDCT-2: 1.2±0.5mSv; RDCT-3: 0.4±0.2mSv; p < 0.05) compared to SDCT. OIN was lower in all RDCT protocols with the application of IRL4 and IRL6, compared to the SDCT with FBP (p < 0.05). CONCLUSION: Highly reduced-dose lumbar spine CT providing diagnostically acceptable image quality is feasible using IR in this cadaver model and may be transferred into a clinical setting.


Assuntos
Vértebras Lombares/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Cadáver , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Variações Dependentes do Observador , Controle de Qualidade
4.
J Occup Med Toxicol ; 15: 21, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32625240

RESUMO

BACKGROUND: Asbestos-related lung diseases are one of the leading diagnoses of the recognized occupational diseases in Germany, both in terms of their number and their socio-economic costs. The aim of this study was to determine whether pulmonary function testing (spirometry and CO diffusion measurement (DLCO)) and computed tomography of the thorax (TCT) are relevant for the early detection of asbestos-related pleural and pulmonary fibrosis and the assessment of the functional deficiency. METHODS: The records of 111 formerly asbestos-exposed workers who had been examined at the Institute for Occupational and Maritime Medicine, Hamburg, Germany, with data on spirometry, DLCO and TCT were reviewed. Workers with substantial comorbidities (cardiac, malignant, silicosis) and/or pulmonary emphysema (pulmonary hyperinflation and/or TCT findings), which, like asbestosis, can lead to a diffusion disorder were excluded. The remaining data of 41 male workers (mean 69.8 years ±6.9) were evaluated. The TCT changes were coded according to the International Classification of High-resolution Computed Tomography for Occupational and Environmental Respiratory Diseases (ICOERD) by radiologists and ICOERD-scores for pleural and pulmonary changes were determined. Correlations (ρ), Cohens κ and accuracy were calculated. RESULTS: In all 41 males the vital capacity (VC in % of the predicted value (% pred.)) showed only minor limitations (mean 96.5 ± 18.0%). The DLCO (in % pred.) was slightly reduced (mean 76.4 ± 16.6%; median 80.1%); the alveolar volume related value (DLCO/VA) was within reference value (mean 102 ± 22%). In the TCT of 27 workers pleural asbestos-related findings were diagnosed whereof 24 were classified as pulmonary fibrosis (only one case with honey-combing). Statistical analysis provided low correlations of VC (ρ = - 0.12) and moderate correlations of DLCO (- 0.25) with pleural plaque extension. The ICOERD-score for pulmonary fibrosis correlated low with VC (0.10) and moderate with DLCO (- 0.23); DLCO had the highest accuracy with 73.2% and Cohens κ with 0.45. DLCO/VA showed no correlations to the ICOERD-score. The newly developed score, which takes into account the diffuse pleural thickening, shows a moderate correlation with the DLCO (ρ = - 0.35, p < 0.05). CONCLUSIONS: In formerly asbestos-exposed workers, lung function alterations and TCT findings correlated moderate, but significant using DLCO and ICOERD-score considering parenchymal ligaments, subpleural curvilinear lines, round atelectases and pleural effusion in addition to pleural plaque extension. DLCO also showed highest accuracy in regard to pulmonary findings. However, VC showed only weaker correlations although being well established for early detection. Besides TCT the determination of both lung function parameters (VC and DLCO) is mandatory for the early detection and assessment of functional deficiencies in workers formerly exposed to asbestos.

5.
Acta Radiol ; 61(8): 1034-1041, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31840526

RESUMO

BACKGROUND: According to the as low as reasonably achievable (ALARA) principle, radiation exposure in computed tomography (CT) should be minimized while maintaining adequate image quality. Dedicated CT protocols combined with iterative reconstruction (IR) can reduce radiation dose and/or improve image quality. PURPOSE: To investigate the feasibility of extremely reduced-dose (RD) CT of the thoracic spine in human cadavers using a standard-dose (SD) and three different RDCT protocols reconstructed with filtered back projection (FBP) and IR. MATERIAL AND METHODS: The thoracic spines of 11 cadavers were examined using different RDCT protocols with decreasing reference tube currents (RDCT-1: 50 mAs; RDCT-2: 30 mAs; RDCT-3: 10 mAs) at 140 kV. A clinical SDCT (70 mAs, 140 kV) served as reference. Raw data were reconstructed using FBP and two increasing levels of IR (IRL4 and IRL6). Images were evaluated for image quality, diagnostic acceptability, and visibility of anatomical structures according to a 5-point-scale. RESULTS: Regardless of the reconstruction technique, image quality was rated as diagnostically acceptable for all cadavers in SDCT and RDCT-1. Image quality of reconstructions with FBP were generally rated lower. Application of IR improved image quality ratings in SDCT and RDCT. RDCT-2 with IR was the most reduced-dose CT protocol which enabled diagnostically acceptable image quality in all cadavers. Compared to SDCT, RDCT protocols resulted in significantly reduced effective radiation doses (SDCT: 4.1 ± 1.5 mSv; RDCT-1: 2.9 ± 1.1 mSv; 2:1.7 ± 0.6 mSv; 3:0.6 ± 0.1 mSv; P = 0.001). CONCLUSION: Diagnostically acceptable RDCT of the thoracic spine with 1.7 mSv is feasible using IR.


Assuntos
Doses de Radiação , Vértebras Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Cadáver , Protocolos Clínicos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
6.
Eur J Radiol ; 120: 108697, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31589994

RESUMO

PURPOSE: To investigate the feasibility of sub-milliSievert CT of the cervical spine in fresh human cadavers using a standard-dose (SD) and four different reduced-dose (RD) protocols reconstructed with filtered back projection (FBP) and iterative reconstruction (IR). METHODS: The cervical spine of 29 cadavers was examined using different RDCT protocols with decreasing reference tube currents (RDCT-1:70 mAs; RDCT-2:50 mAs; RDCT-3:30 mAs; RDCT-4:10 mAs) at 140 kV. A clinical SDCT (160 mAs, 120 kV) served as reference. Raw data were reconstructed using FBP and two increasing levels of IR (IRL4&6). Images of the upper (C1-4) and lower (C5-7) cervical spine were evaluated for image quality, diagnostic acceptability and visibility of anatomical structures according to a 5-point-scale. RESULTS: Image quality of the upper cervical spine was diagnostically acceptable for all protocols using FBP and IR except for RDCT-4 with FBP. Image quality of the lower cervical spine was rated as non-diagnostic in RDCT-3 with FBP and RDCT-4 with FBP and IR. RDCT-3 with IR was the most reduced dose CT protocol allowing diagnostically acceptable image quality for both upper and lower cervical spine in all cadavers. RDCT protocols achieved significantly reduced effective radiation doses (SDCT: 1.5 ± 0.7 mSv; RDCT-1:1 ± 0.6 mSv; RDCT-2:0.7 ± 0.4 mSv; RDCT-3:0.4 ± 0.2 mSv; RDCT-4:0.2 ± 0.1 mSv; p < 0.001). CONCLUSION: Diagnostically acceptable sub-milliSievert CT of the cervical spine is feasible with a low reference tube current at 140 kV using iterative reconstruction and could be suitable for isolated cervical trauma in cooperative patients.


Assuntos
Vértebras Cervicais/anatomia & histologia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Cadáver , Estudos de Viabilidade , Feminino , Humanos , Masculino , Estudos Prospectivos , Doses de Radiação
7.
AJR Am J Roentgenol ; 213(4): 903-911, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31287726

RESUMO

OBJECTIVE. The purpose of this study is to investigate the feasibility of submillisievert CT of the skeletal pelvis of human cadavers using a standard-dose protocol and four different reduced-dose protocols reconstructed with filtered back projection (FBP) and iterative reconstruction (IR). MATERIALS AND METHODS. The pelvis of 25 human cadavers was repeatedly examined using different reduced-dose CT (RDCT) protocols with decreasing reference tube current-exposure time products (RDCT protocol 1, 80 mAs; RDCT protocol 2, 60 mAs; RDCT protocol 3, 40 mAs; and RDCT protocol 4, 10 mAs) and a tube voltage of 120 kV. A standard-dose CT (SDCT) protocol (reference tube current-exposure time product, 100 mAs; tube voltage, 120 kV) used for the same cadavers served as the reference. Raw data were reconstructed using FBP and two increasing levels of IR (IR levels 4 and 6). The image quality and diagnostic acceptability of images of the anterior pelvic ring, acetabulum, and posterior pelvic ring including the sacroiliac joints were evaluated on a 5-point scale. A mixed-effects model for repeated measures was performed. RESULTS. The image quality of all anatomic structures was rated as diagnostically acceptable for all protocols reconstructed with IR, except for 11 cadavers that were imaged using RDCT protocol 4. For reconstructions with FBP, image quality was generally rated lower and was diagnostically acceptable only for images obtained using SDCT and RDCT protocol 1 and 2. RDCT protocol 3 with IR was the RDCT protocol with the largest reduced dose still allowing diagnostically acceptable image quality for all anatomic structures in all cadavers. Compared with SDCT, the RDCT protocols resulted in significantly reduced mean (± SD) effective radiation doses (SDCT, 2.0 ± 0.7 mSv; RDCT protocol 1, 1.6 ± 0.6 mSv; RDCT protocol 2, 1.2 ± 0.4 mSv; RDCT protocol 3, 0.8 ± 0.3 mSv; and RDCT protocol 4, 0.3 ± 0.1 mSv; p = 0.001). CONCLUSION. Diagnostically acceptable submillisievert CT of the skeletal pelvis is feasible using IR. To adhere to the ALARA (as low as reasonably achievable) principle, submillisievert pelvic CT protocols combined with IR should be implemented as part of routine clinical practice.


Assuntos
Pelve/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Cadáver , Estudos de Viabilidade , Feminino , Humanos , Masculino , Doses de Radiação
8.
Eur Radiol ; 29(12): 6953-6964, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31209621

RESUMO

OBJECTIVES: To evaluate the influence of the urinary bladder volume on the detectability of urolithiasis at the ureterovesical junction (UVJ) using a low-dose CT (LD-CT) with iterative reconstruction (IR) and a standard-dose CT (SD-CT) without IR in a large cohort. METHODS: Four hundred patients (278 males (69.5%), mean 44.6 ± 14.7 years) with urolithiasis at the UVJ were investigated either by an LD-CT with IR (n = 289, 72%) or an SD-CT without IR (n = 111, 28%) protocol. The detectability of distal urolithiasis was assessed by a dichotomous assessment (definite or questionable) by two radiologists in consensus and by a quantitative analysis of the signal density distribution across a line drawn parallel to the distal ureter. Based on the resulting graph, minimum/maximum density values and mean/maximum upslopes and downslopes were derived and calculated automatically. In all patients, the total bladder volume was calculated by a slice-by-slice approach on axial CT images. RESULTS: Patients with definite stones showed significantly higher urinary bladder volumes compared to patients with questionable stones in both LD-CT and SD-CT (p < 0.01). These results were independent of stones' length and patients' BMI values. Using cutoffs of 92 ml for LD-CT and 69 ml for SD-CT, high positive predictive values/accuracy rates of 96%/85% (LD-CT) and 98%/86% (SD-CT) were observed to identify definite urinary stones. CONCLUSIONS: Urinary bladder volume has a significant impact on the detectability of distal urolithiasis. Moderate bladder filling by pre-CT hydration with subsequent CT scan at the time of high urge to void increases the detectability of urinary stones at the UVJ in clinical routine. KEY POINTS: • Urinary bladder volume significantly affects the detectability of distal urolithiasis • Higher bladder volumes are associated with improved detectability of distal urinary stones • Oral pre-CT hydration for urolithiasis is easily applicable and cost-effective.


Assuntos
Tomografia Computadorizada por Raios X/métodos , Ureter/diagnóstico por imagem , Bexiga Urinária/diagnóstico por imagem , Cálculos Urinários/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Doses de Radiação , Radiologistas , Estudos Retrospectivos , Urolitíase/diagnóstico por imagem , Adulto Jovem
9.
PLoS One ; 13(8): e0202698, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30133521

RESUMO

OBJECTIVE: To quantify standard values of the discus interpubicus in healthy subjects and to determine reliability and repeatability using T2 relaxation time measurements at 3T. METHODS: 20 asymptomatic participants (10 male, 10 female; mean age: 27.3 years ±4.1, BMI: 22.2 ±1.8) underwent a 3T Magnetic Resonance Imaging (MRI) of the pelvic region in a supine position. We included sagittal and para-axial T2w sequences centred over the pubic symphysis in order to identify the complete discus interpubicus. For quantitative analysis, a multi-echo Turbo Spin Echo (TSE) sequence (including 12 echo times between 6.4 and 76.8 ms) was acquired and analysed by using an in-house developed quantification plugin tool (qMapIt) extending ImageJ. Two readers in consensus defined three central slices of the pubic symphysis with the greatest length. For each slice, both readers separately placed three regions-of-interest (ROI) covering the whole discus interpubicus. Both readers repeated the ROI placements in identical fashion after a four-week interval on the original MRI images. Statistical analysis included intraclass correlation coefficient (ICC), nonparametric Wilcoxon test, Fisher exact test and mean relaxation time in ms and 95% confidence intervals. RESULTS: T2 relaxation time analysis was performed for all 20 participants. In total, a mean relaxation time of all analysed segments for both observers was 48.6 (±6.3 ms), with a mean relaxation time for observer 1 of 48.7 (±6.0 ms) and for observer 2 of 48.5 ms (±6.6ms). The calculated ICC comparing inter- and intrarater reproducibility was excellent in all segments (≥0.75). CONCLUSION: T2 mapping of the discus interpubicus demonstrates good inter- and intrarater repeatability as well as reliability. Mean relaxation times were calculated with 48.6ms in healthy volunteers.


Assuntos
Imageamento por Ressonância Magnética/normas , Sínfise Pubiana/diagnóstico por imagem , Adulto , Estudos de Viabilidade , Feminino , Voluntários Saudáveis , Humanos , Aumento da Imagem , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Adulto Jovem
10.
Rofo ; 190(7): 630-636, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29966156

RESUMO

PURPOSE: The purpose of the study was to assess the impact of iterative model reconstruction (IMR) on reader confidence with respect to stone detection and image quality in comparison to filtered back-projection (FBP) and iDose level 4 (iDose4) in abdominal MDCT with radiation doses below 2 mSv. MATERIALS AND METHODS: For 32 consecutive patients with suspected ureteral stone disease, the raw data of unenhanced 256 slice MDCT (120 kV, 40 reference mAs, mean CTDIvol: 2.7 ±â€Š0.8 mGy, mean DLP: 126 ±â€Š38 mGy × cm) were reconstructed using a prototype version of IMR (levels 1 - 3), iDose4 (level 4) and FBP at a 3 mm slice thickness. Image analysis was independently performed by two radiologists in a blinded fashion. The reader confidence level with respect to stone detection was recorded based on a 5-point scale (1 - certain exclusion; 5 - concrement definitely present) as well as for the evaluation of image quality regarding the depiction of anatomical details (1 - poor; 5 - excellent). A clinical reference standard for stone detection was not established. Statistical evaluation included weighted kappa analysis and Wilcoxon test. RESULTS: 17 pelvic and ureteral stones were found. 11 further concrements were located within the ostium of the urinary bladder or the bladder itself. Applying IMR, a distinct improvement in image quality was observed at every level (mean value for FBP, 2.0; iDose4, 2.9; IMR L1, 4.2; IMR L2, 4.0; IMR L3, 3.9; all p < 0.001). Applying the higher IMR levels L2 and L3, a certain level of so-called "blotchiness" of anatomical contours was observed. Reader confidence was significantly improved and was independent of IMR level (certain stone detection FBP, 69 %; iDose4, 81 %; IMR L1 to L3, 95 %; all p > 0.001). With increasing IMR levels, the reduction in streak artifacts was quantified by a decrease in image noise. A loss of anatomical information was not observed. The sensitivity rates for stone detection were equivalent for all MDCTs reconstructed with FBP, iDose4 and IMR. A mean effective dose of 1.9 ±â€Š0.6 mSv was calculated. CONCLUSION: In comparison to FBP and iDose4, a significant increase in mean image quality, reduction in image noise and improvement in subjective reader confidence can be achieved by applying IMR even at significantly reduced dose settings below 2 mSv. Results indicate that a further dose reduction might be possible with IMR. KEY POINTS: · Urinary tract. · urolithiasis. · iterative reconstruction. CITATION FORMAT: · Schmidt-Holtz J, Laqmani A, Butscheidt S et al. Iterative Model Reconstruction (IMR) in MDCT Below 2mSv for the Detection of Urinary Calculi: Diagnostic Accuracy and Image Quality in Comparison to Filtered Back-Projection and 4th Generation Iterative Reconstruction (iDose4). Fortschr Röntgenstr 2018; 190: 630 - 636.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada Multidetectores/métodos , Intensificação de Imagem Radiográfica/métodos , Cálculos Urinários/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Sensibilidade e Especificidade , Adulto Jovem
12.
J Magn Reson Imaging ; 47(2): 372-379, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28485034

RESUMO

PURPOSE: To compare T2 * relaxation times of the tibiotalar cartilage between professional football players and matched healthy male volunteers. MATERIALS AND METHODS: Twenty-two ankles of professional football players (24.3 ± 3.8 years) and 20 age- and body mass index-matched healthy individuals (25.6 ± 2.4 years) were investigated. The study protocol consisted of multiplanar T1 -weighted, fat-saturated proton-density weighted (Pdw) and a 3D multiecho T2 * sequence with 22 echo times (4.6-53.6 msec). The articular cartilage was subdivided into six segments. Regions of interest were manually drawn in three zones (lateral, central, medial). Differences and confidence intervals were estimated applying a random effects models. Fixed effects were professional football players versus healthy individuals and areas. The random effect was defined as the person cluster of the different individuals. RESULTS: T2 * values were significantly prolonged in football players compared to male volunteers in all predefined cartilage segments (mean, 17.5 vs. 15.5 msec; P < 0.001). In both groups, the highest relaxation times were found in the lateral zone, with statistically higher relaxation times in professional football players (18.5 vs. 16.5 msec, P = 0.003). Separate evaluation revealed the longest relaxation times in the posterior tibiotalar cartilage, with 21.0 msec for professional football players compared to 19.4 msec for healthy volunteers (P = 0.064). CONCLUSION: Based on these initial results, T2 * values of the tibiotalar cartilage seem to be elevated in professional football players compared to healthy volunteers. Prospective longitudinal studies should be encouraged to show if these results represent early subtle cartilage lesions prior to clinical manifestation or rather temporary adaptation related to daily high-level loading. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:372-379.


Assuntos
Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/fisiologia , Atletas , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/fisiologia , Imageamento por Ressonância Magnética/métodos , Adulto , Estudos de Avaliação como Assunto , Voluntários Saudáveis , Humanos , Masculino , Valores de Referência , Futebol , Adulto Jovem
13.
Eur J Radiol ; 95: 278-285, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28987680

RESUMO

OBJECTIVES: Diagnosing acute pancreatitis (AP) may be challenging in patients with acute abdominal pain but missing threefold increased serum lipase levels (Lip-). This studyaims both to characterize these patients using clinical, radiological and mortality data, and to assess the group of patients who need contrast-enhanced computed tomography (CECT). METHODS: In this retrospective, IRB approved study 234 consecutive patients with AP were investigated. Inclusion criteria were single (SAP) and recurrent attacks (RAP) of AP and CECT ≥72h after onset of symptoms. Severity of AP was assessed by C-reactive protein at 48h after hospital admission and using 3 CT-based scores (CTSI, mCTSI, EPIC) by 2 observers. Mortality rates from pancreatic and non-pancreatic causes were noted with regard to lipase increase. Results were compared with paired t-test and Wilcoxon signed-rank test. RESULTS: 64/234 (27%) patients belonged to Lip- group and 170/234 (73%) patients were allocated to Lip+ group. Significantly more male patients (78% in Lip- vs. 63% in Lip+, p<0.05) with RAP (63% in Lip- vs. 21% in Lip+, p<0.001) were observed in the Lip- group. EPIC was significantly lower in Lip- group compared to Lip+ group (3(IQR 2-5) vs. 2(IQR 1-3), p<0.001). Mortality from pancreatic and non-pancreatic causes was comparable in Lip- and Lip+ group (pancreatic causes: 9% vs. 6%, p=0.60; nonpancreatic causes: 8% vs. 5%, p=0.58). CONCLUSIONS: 27% of all patients with AP presented without threefold increase of lipase levels. Thus, they would be underdiagnosed without confirming CECT, which revealed significantly lower counts of pleural effusions and ascites. Male patients with RAP were found significantly more often among the Lip- group. Hence, they would benefit the most from CECT for diagnosing AP.


Assuntos
Lipase/sangue , Pancreatite/sangue , Pancreatite/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pâncreas/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Estudos Retrospectivos , Adulto Jovem
14.
Eur J Radiol ; 85(11): 1971-1979, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27776648

RESUMO

OBJECTIVE: To compare both image quality and visibility of normal and abnormal findings at submillisievert chest CT (smSv-CT) using filtered back projection (FBP) and the two different iterative reconstruction (IR) techniques iterative model reconstruction (IMR) and iDose4™. MATERIALS AND METHODS: This institutional review board approved study was based on retrospective interpretation of clinically indicated acquired data. The requirement to obtain informed consent was waived. 81 patients with suspected pneumonia underwent smSv-CT (Brilliance iCT, Philips Healthcare; mean effective dose: 0.86±0.2mSv). Data were reconstructed using FBP and two different IR techniques iDose4™ and IMR (Philips Healthcare) at various iteration levels. Objective image noise (OIN) was measured. Two experienced readers independently assessed all images for image noise, image appearance and visibility of normal anatomic and abnormal findings. A random intercept model was used for statistical analysis. RESULTS: Compared to FBP and iDose4™, IMR reduced OIN up to 88% and 72%, respectively (p<0.001). A mild blotchy image appearance was seen in IMR images, affecting diagnostic confidence. iDose4™ images provided satisfactory to good image quality for visibility of normal and abnormal findings and were superior to FBP (p<0.001). IMR images were significantly inferior for visibility of normal structures compared to iDose4™, while being superior for visibility of abnormal findings except for reticular pattern (p<0.001). CONCLUSION: IMR results for visibility of normal and abnormal lung findings are heterogeneous, indicating that IMR may not represent a priority technique for clinical routine. iDose4™ represents a suitable method for evaluation of lung tissue at submillisievert chest CT.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Pulmão/diagnóstico por imagem , Pneumonia/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos
15.
PLoS One ; 11(9): e0162429, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27611448

RESUMO

PURPOSE: To assess image quality of CT pulmonary angiography (CTPA) at reduced radiation exposure (RD-CTPA) and contrast medium (CM) volume using two different iterative reconstruction (IR) algorithms (iDose4 and iterative model reconstruction (IMR)) in comparison to filtered back projection (FBP). MATERIALS AND METHODS: 52 patients (body weight < 100 kg, mean BMI: 23.9) with suspected pulmonary embolism (PE) underwent RD-CTPA (tube voltage: 80 kV; mean CTDIvol: 1.9 mGy) using 40 ml CM. Data were reconstructed using FBP and two different IR algorithms (iDose4 and IMR). Subjective and objective image quality and conspicuity of PE were assessed in central, segmental, and subsegmental arteries. RESULTS: Noise reduction of 55% was achieved with iDose4 and of 85% with IMR compared to FBP. Contrast-to-noise ratio significantly increased with iDose4 and IMR compared to FBP (p<0.05). Subjective image quality was rated significantly higher at IMR reconstructions in comparison to iDose4 and FBP. Conspicuity of central and segmental PE significantly improved with the use of IMR. In subsegmental arteries, iDose4 was superior to IMR. CONCLUSIONS: CTPA at reduced radiation exposure and contrast medium volume is feasible with the use of IMR, which provides improved image quality and conspicuity of pulmonary embolism in central and segmental arteries.


Assuntos
Angiografia por Tomografia Computadorizada , Meios de Contraste , Processamento de Imagem Assistida por Computador , Embolia Pulmonar/diagnóstico por imagem , Doses de Radiação , Exposição à Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Meios de Contraste/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
16.
Br J Radiol ; 89(1064): 20151075, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27336705

RESUMO

OBJECTIVE: To quantitatively assess the immediate effect of long-distance running on T2 and T2* relaxation times of the articular cartilage of the knee at 3.0 T in young healthy adults. METHODS: 30 healthy male adults (18-31 years) who perform sports at an amateur level underwent an initial MRI at 3.0 T with T2 weighted [16 echo times (TEs): 9.7-154.6 ms] and T2* weighted (24 TEs: 4.6-53.6 ms) relaxation measurements. Thereafter, all participants performed a 45-min run. After the run, all individuals were immediately re-examined. Data sets were post-processed using dedicated software (ImageJ; National Institute of Health, Bethesda, MD). 22 regions of interest were manually drawn in segmented areas of the femoral, tibial and patellar cartilage. For statistical evaluation, Pearson product-moment correlation coefficients and confidence intervals were computed. RESULTS: Mean initial values were 35.7 ms for T2 and 25.1 ms for T2*. After the run, a significant decrease in the mean T2 and T2* relaxation times was observed for all segments in all participants. A mean decrease of relaxation time was observed for T2 with 4.6 ms (±3.6 ms) and for T2* with 3.6 ms (±5.1 ms) after running. CONCLUSION: A significant decrease could be observed in all cartilage segments for both biomarkers. Both quantitative techniques, T2 and T2*, seem to be valuable parameters in the evaluation of immediate changes in the cartilage ultrastructure after running. ADVANCES IN KNOWLEDGE: This is the first direct comparison of immediate changes in T2 and T2* relaxation times after running in healthy adults.


Assuntos
Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/fisiologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiologia , Imageamento por Ressonância Magnética , Corrida/fisiologia , Adolescente , Adulto , Estudos de Viabilidade , Humanos , Masculino , Valores de Referência , Fatores de Tempo , Adulto Jovem
18.
Crit Care ; 20(1): 139, 2016 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-27160692

RESUMO

BACKGROUND: An algorithm for distinguishing invasive pulmonary aspergillosis (IPA) in critically ill patients (AspICU) has been proposed but not tested. METHODS: This was a prospective observational study applying the AspICU protocol to patients with positive Aspergillus culture (PAC group) and those with negative aspergillus culture but positive galactomannan test in respiratory tract samples (only positive galactomannan (OPG group)). Patients underwent a standardized diagnostic workup with bronchoscopy, computed tomography (CT), and galactomannan determination in serum and bronchoalveolar lavage fluid (BALF). RESULTS: We included 85 patients in the study. Of these, 43 had positive aspergillus cultures and 42 patients had only a positive galactomannan test. There were no statistically significant differences in baseline characteristics, underlying conditions or ICU scores between the two groups. The galactomannan titre in BALF was significantly higher in the positive aspergillus culture (PAC) group (enzyme immunoassay (EIA) 5.9, IQR 3.2-5.7) than in the OPG group (EIA 1.7, IQR 0.9-4.5) (p < 0.001). Classic features of IPA were detected on CT in 37.5 % and 36.6 % of patients in the PAC and OPG groups, respectively. There were no statistically significant differences between the PAC and the OPG group in relation to AspICU or European Organization for the Research and Treatment of Cancer (EORTC) criteria. A positive aspergillus culture was a stronger trigger for initiating antimycotic treatment than positive BALF galactomannan: 88.4 % of patients in the PAC group were regarded by clinicians as having IPA and received antimycotic treatment as opposed to 59.5 % in the OPG group (p = 0.002). The 180-day mortality was 58.1 % in the PAC group and 59.5 % in the OPG group. CONCLUSIONS: The inclusion of BALF galactomannan as an additional entry criterion for the AspICU clinical algorithm could increase the diagnostic sensitivity for IPA in ICU patients. TRIAL REGISTRATION: The study was registered at ClinicalTrials.gov (registration number NCT01866020 ) on 27 May 2013.


Assuntos
Estado Terminal/terapia , Unidades de Terapia Intensiva , Mananas/farmacologia , Mananas/uso terapêutico , Aspergilose Pulmonar/tratamento farmacológico , Idoso , Idoso de 80 Anos ou mais , Antifúngicos/farmacologia , Antifúngicos/uso terapêutico , Galactose/análogos & derivados , Humanos , Estudos Prospectivos , Aspergilose Pulmonar/mortalidade , Irrigação Terapêutica
19.
J Nucl Med ; 57(10): 1556-1559, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27230931

RESUMO

Our objective was to assess the feasibility of 18F-FDG PET/CT for noninvasive monitoring of treatment response after allogeneic stem cell transplantation (SCT) for myelofibrosis. METHODS: Twelve patients with myelofibrosis underwent 18F-FDG PET/CT before and after SCT. Bone marrow uptake, spleen uptake, and spleen size were assessed before and after SCT and compared with hematologic response criteria and bone marrow biopsies. RESULTS: All patients who did not achieve complete remission remained PET-positive (P = 0.02). Extent of disease, bone marrow metabolism, spleen metabolism, and spleen volume decreased significantly in patients with complete remission (P = 0.03). PET/CT after SCT had a sensitivity of 1.0 (95% confidence interval [CI], 0.54-1.0), a specificity of 0.83 (95% CI, 0.36-1.0), a negative predictive value of 1.0 (95% CI, 0.48-1.0), and a positive predictive value of 0.86 (95% CI, 0.42-1.0) for diagnosis of residual disease. CONCLUSION: 18F-FDG PET/CT is feasible for noninvasive monitoring of treatment response after allogeneic SCT for myelofibrosis.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons , Mielofibrose Primária/diagnóstico por imagem , Mielofibrose Primária/terapia , Transplante de Células-Tronco , Idoso , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mielofibrose Primária/metabolismo , Estudos Retrospectivos , Transplante Homólogo , Resultado do Tratamento
20.
Eur Radiol ; 26(1): 216-24, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26070499

RESUMO

OBJECTIVES: To assess the effect of hybrid iterative reconstruction (HIR) and filtered back projection (FBP) on abdominopelvic CT with reduced-dose (RD-APCT) in the evaluation of acute left-sided colonic diverticulitis (ALCD). METHODS: Twenty-five consecutive patients with suspected ALCD who underwent RD-APCT (mean CTDIvol 11.2 ± 4.2 mGy) were enrolled in this study. Raw data were reconstructed using FBP and two increasing HIR levels, L4 & L6. Two radiologists assessed image quality, image noise and reviewer confidence in interpreting findings of ALCD, including wall thickening, pericolic fat inflammation, pericolic abscess, and contained or free extraluminal air. Objective image noise (OIN) was measured. RESULTS: OIN was reduced up to 54 % with HIR compared to FBP. Subjective image quality of HIR images was superior to FBP; subjective image noise was reduced. The detection rate of extraluminal air was higher with HIR L6. Reviewer confidence in interpreting CT findings of ALCD significantly improved with application of HIR. CONCLUSIONS: RD-APCT with HIR offers superior image quality and lower image noise compared to FBP, allowing a high level of reviewer confidence in interpreting CT findings in ALCD. HIR facilitates detection of ALCD findings that may be missed with the FBP algorithm. KEY POINTS: HIR significantly reduces objective image noise in comparison to conventional FBP. HIR offers superior subjective image quality in comparison to conventional FBP. HIR allows reduced-dose abdominopelvic CT with acceptable image quality. Reviewer confidence in interpreting CT findings in ALCD significantly improves with HIR.


Assuntos
Algoritmos , Doença Diverticular do Colo/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...