Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Br J Radiol ; 95(1133): 20201456, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35084228

RESUMO

OBJECTIVES: To evaluate the benefit of a prototype circulation time-based test bolus evaluation algorithm for the individualized optimal timing of contrast media (CM) delivery in patients undergoing coronary CT angiography (CCTA). METHODS: Thirty-two patients (62 ± 16 years) underwent CCTA using a prototype bolus evaluation tool to determine the optimal time-delay for CM administration. Contrast attenuation, signal-to-noise ratio (SNR), objective, and subjective image quality were evaluated by two independent radiologists. Results were compared to a control cohort (matched for age, sex, body mass index, and tube voltage) of patients who underwent CCTA using the generic test bolus peak attenuation +4 s protocol as scan delay. RESULTS: In the study group, the mean time delay to CCTA acquisition was significantly longer (26.0 ± 2.9 s) compared to the control group (23.1 ± 3.5 s; p < 0.01). In the study group, SNR improvement was seen in the right coronary artery (17.5 vs 13; p = 0.028), the left main (15.3 vs 12.3; p = 0.027), and the left anterior descending artery (18.5 vs 14.1; p = 0.048). Subjective image quality was rated higher in the study group (4.75 ± 0.7 vs 3.64 ± 0.5; p < 0.001). CONCLUSIONS: The prototype test bolus evaluation algorithm provided a reliable patient-specific scan delay for CCTA that ensured homogenous vascular attenuation, improvement in objective and subjective image quality, and avoidance of beam hardening artifacts. ADVANCES IN KNOWLEDGE: The prototype contrast bolus evaluation and optimization tool estimated circulation time-based time-delay improves the overall quality of CCTA.


Assuntos
Angiografia por Tomografia Computadorizada , Meios de Contraste , Algoritmos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Humanos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA