Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Br J Radiol ; 94(1128): 20210565, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34672691

RESUMO

OBJECTIVE: To gauge the current availability of dual-energy computed tomography (DECT) scanners in the UK, establish available technologies, look broadly at current clinical uses in adults and paediatrics, and identify barriers to implementation and potential ways to increase use. METHODS: A survey was distributed amongst 10 radiology departments and shared on two national professional co-operation mail bases; the survey ran from 20th July to 9th December 2020. It explored current DECT utilisation in adults and paediatrics as well as barriers to use and suggestions to overcome those barriers. RESULTS: The survey demonstrated DECT availability on 39 (40%) of the 98 CT scanners, but there was limited clinical use in adults and paediatrics. Eighteen (72%) of the 25 respondents had access to at least one DECT scanner, with 14 (56%) having adult DECT protocols in clinical use; <10% head examinations and <50% for other anatomical areas. Only two (8%) respondents had DECT paediatric protocols in clinical use; <10% examinations for all anatomical areas.The main barriers to implementation identified were lack of experience with DECT (8 (44%) users (adult) and 10 (56%) users (paediatric)) and no clinical protocols available (6 (33%) users (adult and paediatric)).Understanding DECT benefits and establishing suitable protocols were the most popular suggestions for increased implementation (10 (40%) of 25 respondents). CONCLUSION: DECT scanners are available, but clinical use is limited for both adults and paediatrics. The main barriers identified were lack of experience with DECT and the availability of suitable protocols. Further work identified to help implementation included better education on the benefits of DECT, provision of clinical protocols and ensuring a multidisciplinary approach. ADVANCES IN KNOWLEDGE: Barriers to implementation of clinical DECT protocols were identified, together with potential solutions to overcome these and enable further implementation.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/estatística & dados numéricos , Inquéritos e Questionários/estatística & dados numéricos , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Humanos , Reino Unido
2.
Br J Radiol ; 90(1071): 20160850, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28102707

RESUMO

OBJECTIVE: To establish a system for patient dosimetry audit and setting of local diagnostic reference levels (LDRLs) for nuclear medicine (NM) CT. METHODS: Computed radiological information system (CRIS) data were matched with NM paper records, which provided the body region and dose mode for NMCT carried out at a large UK hospital. It was necessary to divide data in terms of the NM examination type, body region and dose mode. The mean and standard deviation dose-length products (DLPs) for common NMCT examinations were then calculated and compared with the proposed National Diagnostic Reference Levels (NDRLs). Only procedures which have 10 or more patients will be used to suggest LDRLs. RESULTS: For most examinations, the mean DLPs do not exceed the proposed NDRLs. The bone single-photon emission CT/CT lumbar spine data clearly show the need to divide data according to the purpose of the scan (dose mode), with mean (±standard error) DLPs ranging from 51 ± 5 mGy cm (low dose) to 1086 ± 124 mGy cm (metal dose). CONCLUSION: A system for NMCT patient dose audit has been developed, but there are non-trivial challenges which make the process labour intensive. These include limited information provided by CRIS downloads, dependence on paper records and limited number of examinations available owing to the need to subdivide data. Advances in knowledge: This article demonstrates that a system can be developed for NMCT patient dose audit, but also highlights the challenges associated with such audit, which may not be encountered with more routine audit of radiology CT.


Assuntos
Doses de Radiação , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos , Tomografia Computadorizada de Emissão de Fóton Único/normas , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Tomografia Computadorizada por Raios X/normas , Humanos , Medicina Nuclear , Radiometria , Valores de Referência , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA