1.
Perfusion ; 23(4): 243-5, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19181758

RESUMO

As a consequence of the rising global prevalence and magnitude of obesity, a greater proportion of patients presenting for cardiac surgery is morbidly obese. Being overweight (body mass index; BMI 25-29.9 kg/m(2)) or obese (BMI 30-35 kg/m(2)) appears to confer some survival benefit following cardiac surgery. By contrast, morbid obesity (BMI >40 kg/m(2)) is associated with an increased likelihood of postoperative complications and prolonged intensive care unit and hospital length of stay. The physical difficulties encountered when managing this group of patients is exemplified by those undergoing complex, multiple procedures requiring prolonged cardiopulmonary bypass (CPB) and deep hypothermic circulatory arrest (DHCA). We present the successful management of a massively obese 19-year-old male (BMI 45 kg/m(2)) with Marfan's syndrome who required aortic root and arch replacement under DHCA. The selection of extracorporeal circuit components to accommodate a large circulating volume and permit high CPB flow rates (>9 l/min) is discussed.


Assuntos
Síndromes do Arco Aórtico/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Ponte Cardiopulmonar , Parada Circulatória Induzida por Hipotermia Profunda , Obesidade Mórbida/complicações , Índice de Massa Corporal , Humanos , Masculino , Obesidade Mórbida/tratamento farmacológico , Obesidade Mórbida/cirurgia , Complicações Pós-Operatórias , Adulto Jovem
2.
Magn Reson Imaging ; 19(1): 123-8, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11295354

RESUMO

The purpose of this study was to develop and test a method for the assessment of Magnetic Resonance (MR) scanner performance suitable for routine brain MR studies and for normalization of calculated relaxation times. We hypothesized that regular monitoring of machine performance changes could provide a helpful normalization tool for calculating tissue MR parameters, thus contributing to support their use for longitudinal and comparative studies of both normal and diseased tissues. The method is based on the acquisition of phantom images during routine brain studies with standard spin-echo sequences. MR phantom and brain tissue parameters were used to assess the influence of machine related changes on relaxation parameter estimates. Experimental results showed that scanner performance may affect relaxation rate estimates. Phantom and in vivo results indicate that the correction method yields a reduction in variability of estimated phantom R1 values up to 29% and of R1 for different brain structures up to 17%. These findings support the validity of using brain coil phantoms for routine system monitoring and correction of tissue relaxation rates.


Assuntos
Encéfalo/patologia , Imagem Ecoplanar/instrumentação , Imagem Ecoplanar/normas , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/normas , Imagem Ecoplanar/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Controle de Qualidade
3.
J Magn Reson Imaging ; 12(6): 799-807, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11105017

RESUMO

A fully automated magnetic resonance (MR) segmentation method for identification and volume measurement of demyelinated white matter has been developed. Spin-echo MR brain scans were performed in 38 patients with multiple sclerosis (MS) and in 46 healthy subjects. Segmentation of normal tissues and white matter lesions (WML) was obtained, based on their relaxation rates and proton density maps. For WML identification, additional criteria included three-dimensional (3D) lesion shape and surrounding tissue composition. Segmented images were generated, and normal brain tissues and WML volumes were obtained. Sensitivity, specificity, and reproducibility of the method were calculated, using the WML identified by two neuroradiologists as the gold standard. The average volume of "abnormal" white matter in normal subjects (false positive) was 0.11 ml (range 0-0.59 ml). In MS patients the average WML volume was 31.0 ml (range 1.1-132.5 ml), with a sensitivity of 87.3%. In the reproducibility study, the mean SD of WML volumes was 2.9 ml. The procedure appears suitable for monitoring disease changes over time. J. Magn. Reson. Imaging 2000;12:799-807.


Assuntos
Encéfalo/patologia , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Esclerose Múltipla/diagnóstico , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Sensibilidade e Especificidade
4.
J Magn Reson Imaging ; 11(3): 260-6, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10739557

RESUMO

In 16 patients with probable Alzheimer's disease (AD; NINDS criteria, age range 56-78 years), gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) absolute and fractional volumes were measured with an unsupervised multiparametric post-processing segmentation method based on estimates of relaxation rates R1, R2 (R1 = 1/T1; R2 = 1/T2) and proton density [N(H)] from conventional spin-echo studies (Alfano et al. Magn. Reson. Med. 1997;37:84-93). Global brain atrophy, and GM and WM fractions significantly correlated with Mini-Mental Status Examination and Blessed Dementia Scale scores. Compared with normals, brain compartments in AD patients showed decreased GM (-6.84 +/- 1.58%) and WM fractions (-9.79 +/- 2.47%) and increased CSF fractions (+58.80 +/- 10.37%). Changes were more evident in early-onset AD patients. In AD, measurement of global brain atrophy obtained by a computerized procedure based on routine magnetic resonance studies could complement the information provided by neuropsychological tests for the assessment of disease severity.


Assuntos
Doença de Alzheimer/diagnóstico , Encéfalo/patologia , Imagem Ecoplanar , Imageamento por Ressonância Magnética , Idoso , Atrofia , Ventrículos Cerebrais/patologia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Entrevista Psiquiátrica Padronizada , Pessoa de Meia-Idade , Testes Neuropsicológicos
5.
Ann Med ; 31 Suppl 2: 57-62, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10574157

RESUMO

The thymus is a bilobed lymphoid organ the morphology of which varies considerably with age as a result of a process of fatty infiltration occurring after puberty. Although several diseases can arise in the thymic parenchyma, including germ cell and neuroendocrine tumours, primitive epithelial neoplasms (thymomas) are the most common neoplasms and account for almost 10% of mediastinal masses. Thymomas are usually benign but can be locally invasive. Up to 30% of patients with a thymoma have myasthenia gravis, which is more commonly associated with thymic hyperplasia. The latter results in a symmetric diffuse enlargement of the thymus. However, thymic hyperplasia can be histologically found in up to 50% of normal-sized thymuses on computed tomography (CT). CT is much more accurate in detecting thymomas than it is in detecting thymic hyperplasia, although CT findings may be unspecific. CT can be exhaustive in the case of an encapsulated thymoma (65% of all thymomas), which appear as a solid homogeneous mass with a slight contrast enhancement and a well-defined surrounding fat plane. These tumours rarely recur after surgery. CT can also accurately detect a spread through the capsule into the adjacent mediastinal fat, which characterizes invasive thymomas (35%). These, however, are best evaluated by magnetic resonance imaging (MRI). On T1-weighted MR scans the thymus is well delineated against the mediastinal fat, whereas marked inhomogeneity of the signal may appear on T2-weighted images as a result of areas of cystic degeneration in the tumour mass. The superior contrast resolution of MRI and the multiplanar images that can be produced with it are well suited for documenting the mediastinal spread of invasive thymomas. MRI depicts accurately pleural and/or pericardial implants as well as the involvement of great vessels, offering considerable aid in the planning of surgery.


Assuntos
Timoma/diagnóstico , Timo/diagnóstico por imagem , Timo/patologia , Hiperplasia do Timo/diagnóstico , Neoplasias do Timo/diagnóstico , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Miastenia Gravis/etiologia , Timoma/complicações , Timo/anatomia & histologia , Hiperplasia do Timo/complicações , Neoplasias do Timo/complicações , Tomografia Computadorizada por Raios X
6.
J Nucl Med ; 40(3): 442-7, 1999 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10086709

RESUMO

UNLABELLED: An original method for simultaneous display of functional and anatomic images, based on frequency encoding (FE), merges color PET with T1-weighted MR brain images, and grayscale PET with multispectral color MR images. A comparison with two other methods reported in the literature for image fusion (averaging and intensity modulation techniques) was performed. METHODS: For FE, the Fourier transform of the merged image was obtained summing the low frequencies of the PET image and the high frequencies of the MR image. For image averaging, the merged image was obtained as a weighted average of the intensities of the two images to be merged. For intensity modulation, the red, green and blue components of the color image were multiplied on a pixel-by-pixel basis by the grayscale image. A comparison of the performances of the three techniques was made by three independent observers assessing the conspicuity of specific MRI and PET information in the merged images. For evaluation purposes, images from seven patients and a computer-simulated MRI/PET phantom were used. Data were compared with a chi-square test applied to ranks. RESULTS: For the depiction of MRI and PET information when merging color PET and T1-weighted MR images, FE was rated superior to intensity modulation and averaging techniques in a significant number of comparisons. For merging grayscale PET with multispectral color MR images, FE and intensity modulation were rated superior to image averaging in terms of both MRI and PET information. CONCLUSION: The data suggest that improved simultaneous evaluation of MRI and PET information can be achieved with a method based on FE.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Tomografia Computadorizada de Emissão , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Encefalopatias/diagnóstico , Encefalopatias/diagnóstico por imagem , Humanos , Imagens de Fantasmas
7.
Magn Reson Med ; 39(3): 497-9, 1998 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9498607

RESUMO

To assess the inter-study variability of a recently published unsupervised segmentation method (Magn. Reson. Med. 1997;37:84-93), 14 brain MR studies were performed in five normal subjects. Standard deviations for absolute and fractional volumes of intracranial compartments, which reflect the experimental variability, were smaller than 16.5 ml and 1.1%, respectively. By comparing the experimental component of the variability with the variability observed in our reference database, an estimate of the biological variability of the intracranial fractional volumes in the database population was obtained.


Assuntos
Encéfalo/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Fatores Etários , Idoso , Doença de Alzheimer/patologia , Atrofia , Encéfalo/patologia , Encefalopatias/patologia , Líquido Cefalorraquidiano , Bases de Dados como Assunto , Humanos , Pessoa de Meia-Idade , Esclerose Múltipla/patologia , Imagens de Fantasmas , Análise de Regressão , Reprodutibilidade dos Testes , Estudos Retrospectivos