1.
J Mass Spectrom ; 50(6): 820-5, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26169136

RESUMO

Performance of several library search algorithms (against EI mass spectral databases) implemented in commercial software products ( acd/specdb, chemstation, gc/ms solution and ms search) was estimated. Test set contained 1000 mass spectra, which were randomly selected from NIST'08 (RepLib) mass spectral database. It was shown that composite (also known as identity) algorithm implemented in ms search (NIST) software gives statistically the best results: the correct compound occupied the first position in the list of possible candidates in 81% of cases; the correct compound was within the list of top ten candidates in 98% of cases. It was found that use of presearch option can lead to rejection of the correct answer from the list of possible candidates (therefore presearch option should not be used, if possible). Overall performance of library search algorithms was estimated using receiver operating characteristic curves.

2.
J Sep Sci ; 36(5): 971-9, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23371431

RESUMO

Increasing importation of food and the diversity of potential contaminants have necessitated more analytical testing of these foods. Historically, mass spectrometric methods for testing foods were confined to monitoring selected ions (SIM or MRM), achieving sensitivity by focusing on targeted ion signals. A limiting factor in this approach is that any contaminants not included on the target list are not typically identified and retrospective data mining is limited. A potential solution is to utilize high-resolution MS to acquire accurate mass full-scan data. Based on the instrumental resolution, these data can be correlated to the actual mass of a contaminant, which would allow for identification of both target compounds and compounds that are not on a target list (nontargets). The focus of this research was to develop software algorithms to provide rapid and accurate data processing of LC/MS data to identify both targeted and nontargeted analytes. Software from a commercial vendor was developed to process LC/MS data and the results were compared to an alternate, vendor-supplied solution. The commercial software performed well and demonstrated the potential for a fully automated processing solution.


Assuntos
Cromatografia Líquida/instrumentação , Mineração de Dados , Espectrometria de Massas/instrumentação , Algoritmos , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...