Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Can Prosthet Orthot J ; 4(1): 35213, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-37614936

RESUMO

BACKGROUND: Lab-based simulators can help to reduce variability in prosthetics research. However, they have not yet been used to investigate the effects of sweating at the residuum-liner interface. This work sought to create and validate a simulator to replicate the mechanics of residual limb perspiration. The developed apparatus was used to assess the effects of perspiration and different liner designs. METHODOLOGY: By scanning a cast, an artificial residuum was manufactured using a 3D-printed, transtibial bone model encased in silicone, moulded with pores. The pores allowed water to emit from the residuum surface, simulating sweating. Dry and sweating cyclic tests were performed by applying compressive and tensile loading, while measuring the displacement of the residuum relative to the socket. Tests were conducted using standard and perforated liners. FINDINGS: Although maximum displacement varied between test setups, its variance was low (coefficient of variation <1%) and consistent between dry tests. For unperforated liners, sweating increased the standard deviation of maximum displacement approximately threefold (0.04mm v 0.12mm, p<0.001). However, with the perforated liner, sweating had little effect on standard deviation compared to dry tests (0.04mm v 0.04mm, p=0.497). CONCLUSIONS: The test apparatus was effective at simulating the effect of perspiration at the residual limb. Moisture at the skin-liner interface can lead to inconsistent mechanics. Perforated liners help to remove sweat from the skin-liner interface, thereby mitigating these effects.

2.
Can Prosthet Orthot J ; 2(2): 33517, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-37614771

RESUMO

BACKGROUND: Lower limb amputees have a high incidence of comorbidities, such as osteoarthritis, which are believed to be caused by kinetic asymmetries. A lack of prosthetic adaptation to different terrains requires kinematic compensations, which may influence these asymmetries. METHOD: Six SIGAM grade E-F trans-tibial amputees (one bilateral) wore motion capture markers while standing on force plates, facing down a 5° slope. The participants were tested under three prosthetic conditions; a fixed attachment foot (FIX), a hydraulic ankle (HYD) and a microprocessor foot with a 'standing support' mode (MPF). The resultant ground reaction force (GRF) and support moment for prosthetic and sound limbs were chosen as outcome measures. These were compared between prosthetic conditions and to previously captured able-bodied control data. RESULTS: The distribution of GRF between sound and prosthetic limbs was not significantly affected by foot type. However, the MPF condition required fewer kinematic compensations, leading to a reduction in sound side support moment of 59% (p=0.001) and prosthetic side support moment of 43% (p=0.02) compared to FIX. For the bilateral participant, only the MPF positioned the GRF vector anterior to the knees, reducing the demand on the residual joints to maintain posture. CONCLUSIONS: For trans-tibial amputees, loading on lower limb joints is affected by prosthetic foot technology, due to the kinematic compensations required for slope adaptation. MPFs with 'standing support' might be considered reasonable and necessary for bilateral amputees, or amputees with stability problems due to the reduced biomechanical compensations evident.

3.
Med Eng Phys ; 38(7): 695-700, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27118308

RESUMO

A sensor system for measurement of pressure and shear at the lower limb residuum/socket interface is described. The system comprises of a flexible sensor unit and a data acquisition unit with wireless data transmission capability. Static and dynamic performance of the sensor system was characterised using a mechanical test machine. The static calibration results suggest that the developed sensor system presents high linearity (linearity error ≤ 3.8%) and resolution (0.9 kPa for pressure and 0.2 kPa for shear). Dynamic characterisation of the sensor system shows hysteresis error of approximately 15% for pressure and 8% for shear. Subsequently, a pilot amputee walking test was conducted. Three sensors were placed at the residuum/socket interface of a knee disarticulation amputee and simultaneous measurements were obtained during pilot amputee walking test. The pressure and shear peak values as well as their temporal profiles are presented and discussed. In particular, peak pressure and shear of approximately 58 kPa and 27 kPa, respectively, were recorded. Their temporal profiles also provide dynamic coupling information at this critical residuum/socket interface. These preliminary amputee test results suggest strong potential of the developed sensor system for exploitation as an assistive technology to facilitate socket design, socket fit and effective monitoring of lower limb residuum health.


Assuntos
Cotos de Amputação , Extremidade Inferior , Pressão , Estresse Mecânico , Membros Artificiais , Calibragem , Humanos , Desenho de Prótese
4.
Med Eng Phys ; 37(1): 132-7, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25455164

RESUMO

A novel capacitance-based sensor designed for monitoring mechanical stresses at the stump-socket interface of lower-limb amputees is described. It provides practical means of measuring pressure and shear stresses simultaneously. In particular, it comprises of a flexible frame (20 mm × 20 mm), with thickness of 4mm. By employing rapid prototyping technology in its fabrication, it offers a low-cost and versatile solution, with capability of adopting bespoke shapes of lower-limb residua. The sensor was first analysed using finite element analysis (FEA) and then evaluated using lab-based electromechanical tests. The results validate that the sensor is capable of monitoring both pressure and shear at stresses up to 350 kPa and 80 kPa, respectively. A post-signal processing model is developed to induce pressure and shear stresses, respectively. The effective separation of pressure and shear signals can be potentially advantageous for sensor calibration in clinical applications. The sensor also demonstrates high linearity (approx. 5-8%) and high pressure (approx. 1.3 kPa) and shear (approx. 0.6 kPa) stress resolution performance. Accordingly, the sensor offers the potential for exploitation as an assistive tool to both evaluate prosthetic socket fitting in clinical settings and alert amputees in home settings of excessive loading at the stump-socket interface, effectively preventing stump tissue breakdown at an early stage.


Assuntos
Membros Artificiais , Capacitância Elétrica , Pressão , Impressão Tridimensional , Estresse Mecânico , Cotos de Amputação/fisiopatologia , Elastômeros , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Perna (Membro) , Úlcera da Perna/prevenção & controle , Modelos Lineares , Maleabilidade , Processamento de Sinais Assistido por Computador
5.
Commun Agric Appl Biol Sci ; 71(3 Pt B): 1125-32, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17390868

RESUMO

Carrot black rot caused by the fungus Alternaria radicina (Meier) Drechsler et Eddy, the economically important disease of carrot (Daucus carota L.). Research was carried out in 2004 and 2005 in order to establish correlation between plant infestation in the field and laboratory experiments. To determine the incidence and severity of the disease in mature crop, a 5-degree scale was used, where 1 meant no visible disease symptoms and 5 meant total foliage infestation. Plants were rated individually and the disease index was calculated. Fungus pathogenicity in laboratory conditions was determined using a petiole assay and a root disc assay. The petiole assay was conducted during the vegetation period; basal parts of petioles detached from fully developed carrot leaves were put in contact with the growing A. radicina mycelium. The root disc assay was conducted during storage of carrot roots; root discs were inoculated with toothpicks overgrown by A. radicina mycelium. The isolate of A. radicina was pathogenic to petioles and carrot discs. Differences in the reaction of the examined cultivars in the field and laboratory experiments were revealed. However, no significant correlation between plant infestation in the field and the results of laboratory experiments were observed.


Assuntos
Alternaria/patogenicidade , Daucus carota/microbiologia , Daucus carota/fisiologia , Doenças das Plantas/microbiologia , Folhas de Planta/microbiologia , Folhas de Planta/crescimento & desenvolvimento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...