Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
1.
Eur Radiol ; 30(10): 5367-5369, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32435927
2.
PLoS One ; 12(11): e0187528, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29125850

RESUMO

OBJECTIVES: The aim of this study was to investigate and compare the feasibility as well as potential impact of altered magnetic field properties on image quality and potential artifacts of 1.5 Tesla, 3 Tesla and 7 Tesla non-enhanced abdominal MRI. MATERIALS AND METHODS: Magnetic Resonance (MR) imaging of the upper abdomen was performed in 10 healthy volunteers on a 1.5 Tesla, a 3 Tesla and a 7 Tesla MR system. The study protocol comprised a (1) T1-weighted fat-saturated spoiled gradient-echo sequence (2D FLASH), (2) T1-weighted fat-saturated volumetric interpolated breath hold examination sequence (3D VIBE), (3) T1-weighted 2D in and opposed phase sequence, (4) True fast imaging with steady-state precession sequence (TrueFISP) and (5) T2-weighted turbo spin-echo (TSE) sequence. For comparison reasons field of view and acquisition times were kept comparable for each correlating sequence at all three field strengths, while trying to achieve the highest possible spatial resolution. Qualitative and quantitative analyses were tested for significant differences. RESULTS: While 1.5 and 3 Tesla MRI revealed comparable results in all assessed features and sequences, 7 Tesla MRI yielded considerable differences in T1 and T2 weighted imaging. Benefits of 7 Tesla MRI encompassed an increased higher spatial resolution and a non-enhanced hyperintense vessel signal at 7 Tesla, potentially offering a more accurate diagnosis of abdominal parenchymatous and vasculature disease. 7 Tesla MRI was also shown to be more impaired by artifacts, including residual B1 inhomogeneities, susceptibility and chemical shift artifacts, resulting in reduced overall image quality and overall image impairment ratings. While 1.5 and 3 Tesla T2w imaging showed equivalently high image quality, 7 Tesla revealed strong impairments in its diagnostic value. CONCLUSIONS: Our results demonstrate the feasibility and overall comparable imaging ability of T1-weighted 7 Tesla abdominal MRI towards 3 Tesla and 1.5 Tesla MRI, yielding a promising diagnostic potential for non-enhanced Magnetic Resonance Angiography (MRA). 1.5 Tesla and 3 Tesla offer comparably high-quality T2w imaging, showing superior diagnostic quality over 7 Tesla MRI.


Assuntos
Abdome/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino
3.
PLoS One ; 12(7): e0180349, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28683109

RESUMO

OBJECTIVES: To evaluate the added value of the application of the liver-specific contrast phase of Gadobenate dimeglumine (Gd-BOPTA) for detection and characterization of liver lesions in 18F-FDG PET/MRI. METHODS: 41 patients with histologically confirmed solid tumors and known / suspected liver metastases or not classifiable lesions in 18F-FDG PET/CT were included in this study. All patients underwent a subsequent Gd-BOPTA enhanced 18F-FDG PET/MRI examination. MRI without liver-specific contrast phase (MRI1), MRI with liver-specific contrast phase (MRI2), 18F-FDG PET/MRI without liver-specific contrast phase (PET/MRI1) and with liver-specific contrast phase (PET/MRI2) were separately evaluated for suspect lesions regarding lesion dignity, characterization, conspicuity and confidence. RESULTS: PET/MRI datasets enabled correct identification of 18/18 patients with malignant lesions; MRI datasets correctly identified 17/18 patients. On a lesion-based analysis PET/MRI2 provided highest accuracy for differentiation of lesions into malignant and benign lesions of 98% and 100%. Respective values were 95% and 100% for PET/MRI1, 93% and 96% for MRI2 and 91% and 93% for MRI1. Statistically significant higher diagnostic confidence was found for PET/MRI2 and MRI2 datasets compared to PET/MRI1 and MRI1, respectively (p < 0.001). CONCLUSION: The application of the liver-specific contrast phase in 18F-FDG PET/MRI further increases the diagnostic accuracy and diagnostic confidence for correct assessment of benign and malignant liver lesions.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste/farmacocinética , Neoplasias Hepáticas/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos/farmacocinética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Adulto , Idoso , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/metabolismo , Neoplasias da Mama/patologia , Carcinoma Hepatocelular/metabolismo , Carcinoma Hepatocelular/secundário , Colangiocarcinoma/diagnóstico por imagem , Colangiocarcinoma/metabolismo , Colangiocarcinoma/patologia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/metabolismo , Neoplasias Colorretais/patologia , Feminino , Fluordesoxiglucose F18/farmacocinética , Humanos , Fígado/metabolismo , Fígado/patologia , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/secundário , Masculino , Meglumina/farmacocinética , Melanoma/diagnóstico por imagem , Melanoma/metabolismo , Melanoma/patologia , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/farmacocinética , Sensibilidade e Especificidade
4.
Eur J Radiol ; 86: 76-82, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28027770

RESUMO

OBJECTIVES: To investigate whether a dose reduction of Gadobutrol for renal magnetic resonance angiography (MRA) at 7 Tesla (T) is feasible while preserving diagnostic image quality. METHODS: Ten healthy volunteers were enrolled for a renal MRA on a 7T scanner. Fast low angle shot (FLASH) MRA data sets were obtained utilizing three different doses of Gadobutrol (0.1, 0.05 and 0.025mmol/kg body weight [BW]). Contrast ratios (CR) were measured in the aorta as well as in the intra- and extraparenchymal arteries compared to the psoas muscle. Qualitative analysis regarding the delineation of vessel structures was performed using a four-point-scale. RESULTS: All doses of Gadobutrol allowed for a good delineation of the aorta and renal arteries. For the extra- and intraparenchymal segmental arteries higher values were observed for full and half dose in comparison to quarter dose. No significant difference was observed for full and half dose. A lower CR was observed for quarter compared to half dose (p<0.05) for the renal arteries. CONCLUSIONS: While best results were observed for half and full dose, a dose reduction to 0.025mmol/kg BW is justifiable, maintaining a diagnostic image quality. This may be of high interest considering patients with renal impairment.


Assuntos
Meios de Contraste , Gadolínio , Angiografia por Ressonância Magnética/métodos , Artéria Renal/anatomia & histologia , Adulto , Aorta Abdominal/anatomia & histologia , Artefatos , Relação Dose-Resposta a Droga , Estudos de Viabilidade , Feminino , Voluntários Saudáveis , Humanos , Masculino , Compostos Organometálicos , Estudos Prospectivos , Adulto Jovem
5.
Eur J Radiol ; 85(2): 414-21, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26781147

RESUMO

PURPOSE: To implement a protocol for PET/MR enterography for a multimodal assessment of intestinal pathologies. MATERIALS AND METHODS: 19 patients with bowel malignancies, Crohn's disease or fever of unknown origin (male: n=14, female: n=5, age: 57±13years) underwent PET/MR enterography with either [(18)F]FDG (n=10) or [(68)Ga]-DOTATOC (n=9) using an integrated scanner. For small bowel distension a contrast solution (1500 cm(3) of mannitol and locust bean gum) was ingested. The following sequences were acquired: (a) coronal TrueFISP; (b) coronal T2w HASTE; (c) coronal dynamic T1w VIBE; (d) axial and coronal T1w FLASH post gadolinium. All datasets were reviewed by two readers with regard to co-registration of anatomical structures based on a 3-point ordinal scale as well as overall image quality using a 4-point ordinal scale. Furthermore, visualization of intestinal and extra-intestinal pathologies was assessed. RESULTS: PET/MR enterography was well tolerated by all patients. High overall MR image quality was achieved (mean score: 3.2±0.6) with good co-registration of PET and MRI (mean scores: 2.6 to 3.0). PET/MR enterography allowed for an excellent visualization of both intestinal as well as extra-intestinal pathologies. CONCLUSION: PET/MR enterography is technically feasible and offers good co-registration of bowel structures. This novel method enables a multimodal assessment of bowel lesions in malignant and inflammatory disease.


Assuntos
Enteropatias/diagnóstico por imagem , Enteropatias/patologia , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Meios de Contraste , Estudos de Viabilidade , Feminino , Fluordesoxiglucose F18 , Radioisótopos de Gálio , Humanos , Aumento da Imagem , Intestinos/diagnóstico por imagem , Intestinos/patologia , Masculino , Pessoa de Meia-Idade , Octreotida/análogos & derivados , Compostos Radiofarmacêuticos
6.
Magn Reson Imaging ; 34(5): 668-73, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26747410

RESUMO

OBJECTIVE: To perform non-enhanced (NE) magnetic resonance imaging (MRI) of the small bowel at 7 Tesla (7T) and to compare it with 1.5 Tesla (1.5T). MATERIAL AND METHODS: Twelve healthy subjects were prospectively examined using a 1.5T and 7T MRI system. Coronal and axial true fast imaging with steady-state precession (TrueFISP) imaging and a coronal T2-weighted (T2w) half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence were acquired. Image analysis was performed by 1) visual evaluation of tissue contrast and detail detectability, 2) measurement and calculation of contrast ratios and 3) assessment of artifacts. RESULTS: NE MRI of the small bowel at 7T was technically feasible. In the vast majority of the cases, tissue contrast and image details were equivalent at both field strengths. At 7T, two cases revealed better detail detectability in the TrueFISP, and better contrast in the HASTE. Susceptibility artifacts and B1 inhomogeneities were significantly increased at 7T. CONCLUSION: This study provides first insights into NE ultra-high field MRI of the small bowel and may be considered an important step towards high quality T2w abdominal imaging at 7T MRI.


Assuntos
Intestino Delgado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Artefatos , Feminino , Humanos , Masculino , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes , Adulto Jovem
7.
PLoS One ; 10(9): e0137285, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26335246

RESUMO

BACKGROUND: The aim of this study was to compare the diagnostic accuracy of [18F]FDG-PET/MRI with PET/CT for the detection of liver metastases. METHODS: 32 patients with solid malignancies underwent [18F]FDG-PET/CT and subsequent PET/MRI of the liver. Two readers assessed both datasets regarding lesion characterization (benign, indeterminate, malignant), conspicuity and diagnostic confidence. An imaging follow-up (mean interval: 185±92 days) and/-or histopathological specimen served as standards of reference. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for both modalities. Accuracy was determined by calculating the area under the receiver operating characteristic (ROC) curve. Values of conspicuity and diagnostic confidence were compared using Wilcoxon-signed-rank test. RESULTS: The standard of reference revealed 113 liver lesions in 26 patients (malignant: n = 45; benign: n = 68). For PET/MRI a higher accuracy (PET/CT: 82.4%; PET/MRI: 96.1%; p<0.001) as well as sensitivity (67.8% vs. 92.2%, p<0.01) and NPV (82.0% vs. 95.1%, p<0.05) were observed. PET/MRI offered higher lesion conspicuity (PET/CT: 2.0±1.1 [median: 2; range 0-3]; PET/MRI: 2.8±0.5 [median: 3; range 0-3]; p<0.001) and diagnostic confidence (PET/CT: 2.0±0.8 [median: 2; range: 1-3]; PET/MRI 2.6±0.6 [median: 3; range: 1-3]; p<0.001). Furthermore, PET/MRI enabled the detection of additional PET-negative metastases (reader 1: 10; reader 2: 12). CONCLUSIONS: PET/MRI offers higher diagnostic accuracy compared to PET/CT for the detection of liver metastases.


Assuntos
Carcinoma/secundário , Neoplasias Hepáticas/secundário , Imageamento por Ressonância Magnética , Melanoma/secundário , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Adulto , Idoso , Área Sob a Curva , Carcinoma/diagnóstico por imagem , Carcinoma/patologia , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Masculino , Melanoma/diagnóstico por imagem , Melanoma/patologia , Pessoa de Meia-Idade , Imagem Multimodal/normas , Variações Dependentes do Observador , Valor Preditivo dos Testes , Curva ROC , Sensibilidade e Especificidade , Estatísticas não Paramétricas
8.
PLoS One ; 10(9): e0137587, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26335790

RESUMO

PURPOSE: Selective Internal Radiation Therapy (SIRT) with 90yttrium (Y-90) is an increasingly used therapeutic option for unresectable liver malignancies. Nontarget embolization of extrahepatic tissue secondary to vascular shunting can lead to SIRT associated complications. Our aim was to assess whether extrahepatic shunts can reliably be diagnosed based on hepatic digital subtraction angiography (DSA) or whether subsequent SPECT/CT data can provide additional information. MATERIALS AND METHODS: 825 patients with hepatocellular carcinoma (n = 636), hepatic metastases (n = 158) or cholangiocellular carcinoma (n = 31) were retrospectively analyzed. During hepatic DSA 128 arteries causing shunt flow to gastrointestinal tissue were coilembolized (right gastric artery n = 63, gastroduodenal artery n = 29; branches to duodenum / pancreas n = 36). Technectium-99m-labeled human serum albumin (HSA) was injected in all 825 patients. SPECT/CT data was used to identify additional or remaining shunts to extrahepatic tissue. RESULTS: An unexpected uptake of HSA in extrahepatic tissue was found by SPECT/CT in 54/825 (6.5%) patients (located in stomach n = 13, duodenum n = 26, distal bowel segments n = 12, kidney n = 1, diaphragm n = 2). These patients underwent repeated DSA and newly identified shunt vessels were coilembolized in 22/54 patients, while in 12/54 patients a more distal catheter position for repeat injection of HSA was chosen. In 20/54 patients the repeated SPECT/CT data still revealed an extrahepatic HSA uptake. These patients did not receive SIRT. CONCLUSION: Most extrahepatic shunts can be identified on DSA prior to Y-90 therapy. However, SPECT-CT data helps to identify additional shunts that were initially not seen on DSA.


Assuntos
Braquiterapia/instrumentação , Colestase/radioterapia , Embolização Terapêutica/instrumentação , Neoplasias Hepáticas/radioterapia , Fígado/diagnóstico por imagem , Microesferas , Idoso , Angiografia Digital , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/radioterapia , Colangiocarcinoma/diagnóstico por imagem , Colangiocarcinoma/radioterapia , Colestase/diagnóstico por imagem , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada de Emissão de Fóton Único , Radioisótopos de Ítrio/uso terapêutico
9.
Skeletal Radiol ; 44(10): 1467-75, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26093539

RESUMO

OBJECTIVE: To analyze remodeling processes after advanced core decompression (ACD) in patients with avascular femoral head necrosis by means of 3T MRI and to identify indicators for clinical outcome considering the defect size and characteristics of the bone graft and of the neighboring regeneration tissue. MATERIALS AND METHODS: Thirty-four hips, with preexisting preoperative MRIs in 21 cases, were examined 1-34 months (mean 12.7) postoperatively by 3T MRI. The volume of necrosis was measured manually pre- and postoperatively to calculate absolute as well as percentage necrosis reduction. The signal intensity of the bone graft was quantified using a 4-point scale. Border phenomena between the bone graft and bone were described and classified into groups. Wilcoxon sign-rank test was used to identify correlations between the analyzed items and clinical signs of femoral head collapse after a mean follow-up time of 28.6 months (10.4-46.8). RESULTS: Mean percentage reduction of necrosis was significantly higher in asymptomatic patients (59.36%) compared to patients with signs of femoral head collapse (28.78%, p = 0.008). Signal intensity of the bone graft increased in T1w and T2w TIRM sequences over time after surgery and was significantly higher in asymptomatic patients. Five border phenomena between the bone graft and healthy bone were identified. Among them, the so-called "rail sign" representing three layers of remodeling tissue correlated with the histological observations. CONCLUSION: A variety of border phenomena representing remodeling processes have been described using 3T MRI. Beneath the percentage amount of necrosis reduction, we identified the signal intensity of the bone graft as an indicator for clinical outcome.


Assuntos
Transplante Ósseo , Descompressão Cirúrgica , Necrose da Cabeça do Fêmur/cirurgia , Cabeça do Fêmur/cirurgia , Imageamento por Ressonância Magnética , Complicações Pós-Operatórias/diagnóstico , Remodelação Óssea , Feminino , Cabeça do Fêmur/patologia , Necrose da Cabeça do Fêmur/patologia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Período Pós-Operatório , Resultado do Tratamento
10.
J Vasc Interv Radiol ; 26(7): 972-9, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25937296

RESUMO

PURPOSE: To compare the utility of gadolinium ethoxybenzyl diethylenetriamine penta-acetic acid (Gd-EOB-DTPA), a liver-specific magnetic resonance (MR) imaging contrast agent, versus gadobutrol for treatment response evaluation of hepatocellular carcinoma (HCC) after radioembolization. MATERIALS AND METHODS: This prospective study included 50 patients with HCC undergoing radioembolization. All patients underwent contrast-enhanced computed tomography (CT) and MR imaging with gadobutrol and Gd-EOB-DTPA on 2 consecutive days before radioembolization and 30 days, 90 days, 180 days, and 270 days after radioembolization. The standard of reference indicating tumor progression was CT combined with either α-fetoprotein or γ-glutamyltransferase. Gadobutrol-enhanced MR imaging, Gd-EOB-DTPA-enhanced MR imaging without late phase imaging (Gd-EOB-DTPA-), and Gd-EOB-DTPA-enhanced MR imaging with late phase imaging (Gd-EOB-DTPA+) were evaluated by 2 radiologists in consensus using a 4-point scale: 1 = definitely no tumor progression; 2 = probably no tumor progression; 3 = probably tumor progression; 4 = definitely tumor progression. Diagnostic accuracy was assessed with receiver operating characteristic analysis. RESULTS: Tumor progression was detected in 14 of 82 study visits according to the reference standard. Pairwise comparison of the area under the curve showed a tendency toward a larger area under the curve for Gd-EOB-DTPA+ compared with gadobutrol (P = .056). Sensitivity and specificity were higher in Gd-EOB-DTPA+ (0.929 and 0.971) than in Gd-EOB-DTPA- (0.786 and 0.941) or gadobutrol (0.643 and 0.956). In 2 cases, tumor progression was detected by Gd-EOB-DTPA+ and by an increase in α-fetoprotein, but not by CT, gadobutrol, or Gd-EOB-DTPA-. CONCLUSIONS: Gd-EOB-DTPA+ MR imaging was not inferior to gadobutrol-enhanced MR imaging in therapy response evaluation after radioembolization and may allow a more accurate detection of early HCC recurrence in single cases.


Assuntos
Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/radioterapia , Meios de Contraste , Embolização Terapêutica/métodos , Gadolínio DTPA , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/radioterapia , Imageamento por Ressonância Magnética , Compostos Organometálicos , Compostos Radiofarmacêuticos/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Carcinoma Hepatocelular/sangue , Feminino , Alemanha , Humanos , Neoplasias Hepáticas/sangue , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , alfa-Fetoproteínas/metabolismo , gama-Glutamiltransferase/sangue
11.
Invest Radiol ; 50(8): 539-47, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25945458

RESUMO

OBJECTIVES: T1-weighted (T1w) contrast-enhanced magnetic resonance imaging (MRI) of the small bowel at 1.5 T magnetic field strength has become a standard technique in investigating diseases of the small bowel. High-field MRI potentially offers improved soft tissue contrast and spatial resolution, providing increased image detail. The purpose of this study was to evaluate the feasibility of contrast-enhanced small bowel MRI at 7 T and to compare results with 1.5 T. MATERIALS AND METHODS: Twelve healthy volunteers underwent small bowel MRI on a 1.5 T and 7 T MRI system. A coronal fat-saturated T1w spoiled gradient-echo sequence (3-dimensional [3D] FLASH) was applied precontrast and at 20 seconds, 75 seconds, and 120 seconds after intravenous contrast administration. Furthermore, late-phase coronal and axial fat-saturated T1w 2-dimensional (2D) FLASH data sets were acquired. Visual evaluation of tissue contrast and image detail of the small bowel wall and mesentery as well as contrast ratios were compared between 1.5 T and 7 T in an intraindividual comparison. In addition, subjective ratings of image impairment by artifacts were assessed at both field strengths. RESULTS: Magnetic resonance imaging of the small bowel at 7 T revealed equal tissue contrast and image detail compared with 1.5 T. Higher contrast and improved image detail of mesentery structures at 7 T were found in nonenhanced 3D FLASH. Quantitatively measured contrast between the bowel wall and bowel lumen showed significantly lower contrast at 7 T in nonenhanced 3D FLASH and in late-phase 2D FLASH. Image quality was more impaired at 7 T compared with 1.5 T, mainly due to increased susceptibility artifacts and B1 inhomogeneities. CONCLUSIONS: T1-weighted contrast-enhanced MRI of the small bowel at 7 T represents a promising MR technique for establishing ultra-high magnetic field strengths in clinical applications. Despite increased artifacts at 7 T, depiction of the small bowel was achieved with comparable quality to the current state-of-the-art field strength of 1.5 T. Assessment of potential diagnostic benefits should be the focus of future high-field MRI studies.


Assuntos
Meios de Contraste , Aumento da Imagem , Intestino Delgado/anatomia & histologia , Imageamento por Ressonância Magnética , Adulto , Artefatos , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Adulto Jovem
12.
Acta Radiol Open ; 4(4): 2047981615570417, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25922690

RESUMO

BACKGROUND: Overall survival (OS) of patients with hepatic metastases of uveal melanoma is strongly linked with hepatic tumor control. Due to the lack of an effective systemic chemotherapy, locoregional therapies like radioembolization should play an increasingly important role. PURPOSE: To report complications and response rates of radioembolization as salvage therapy for hepatic uveal melanoma metastases. MATERIAL AND METHODS: Between October 2006 and January 2014, eight patients (age, 59.1 ± 15.3 years; 5 men) with histologically proven uveal melanoma and hepatic metastases received radioembolization with glass microspheres at a single center. All patients had been heavily pretreated with multiple systemic/locoregional therapies resulting in a long median interval between diagnosis of hepatic metastases and radioembolization (17.1 months; range, 6.4-23.2 months). Follow-up consisted of clinical assessment, laboratory tests and tri-phasic computed tomography (CT) before and 1, 3, 6, 9, and 12 months after radioembolization. Response to therapy was evaluated by CT using RECIST version 1.1 and by survival time. Safety (laboratory and clinical toxicity) was rated according to Common Terminology Criteria for Adverse Events 4.03. Using Kaplan-Meier analysis time to progression of hepatic metastases (hTTP) and OS were calculated. RESULTS: One month after radioembolization 50% of patients presented with stable and 50% with progressive disease. Median hTTP and OS after radioembolization were 4.3 weeks (range, 3.4-28.6 weeks) and 12.3 weeks (range, 3.7-62.6 weeks), respectively. Median OS after diagnosis of hepatic metastases was 19.9 months (range, 7.3-31.4 months). Radioembolization was tolerated well in all patients without toxicity higher than grade 2. CONCLUSION: Radioembolization is a safe salvage therapy even in heavily pretreated hepatic metastases of uveal melanoma.

13.
Skeletal Radiol ; 44(7): 941-51, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25805436

RESUMO

OBJECTIVE: To evaluate the usefulness of the metal artifact reduction technique "WARP" in the assessment of metal-on-metal hip resurfacings at 1.5 and 3T in the context of image quality and imaging speed. MATERIALS AND METHODS: Nineteen patients (25 hip resurfacings) were randomized for 1.5 and 3T MRI, both including T1 and T2 turbo spin-echo as well as turbo inversion recovery magnitude sequences with and without view angle tilting and high bandwidth. Additional 3T sequences were acquired with a reduced number of averages and using the parallel acquisition technique for accelerating imaging speed. Artifact size (diameter, area), image quality (5-point scale) and delineation of anatomical structures were compared among the techniques, sequences and field strengths using the Wilcoxon sign-rank and paired t-test with Bonferroni correction. RESULTS: At both field strengths, WARP showed significant superiority over standard sequences regarding image quality, artifact size and delineation of anatomical structures. At 3T, artifacts were larger compared to 1.5T without affecting diagnostic quality, and scanning time could be reduced by up to 64 % without quality degradation. CONCLUSION: WARP proved useful in imaging metal-on-metal hip resurfacings at 1.5T as well as 3T with better image quality surrounding the implants. At 3T imaging could be considerably accelerated without losing diagnostic quality.


Assuntos
Artefatos , Articulação do Quadril/patologia , Prótese de Quadril , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Próteses Articulares Metal-Metal , Metais , Adulto , Idoso , Feminino , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Invest Radiol ; 50(1): 32-9, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25215934

RESUMO

OBJECTIVES: Magnetic resonance colonography (MRC) is a well-accepted, noninvasive imaging modality for the depiction of inflammatory bowel disease. Diffusion-weighted imaging (DWI) is very helpful to display inflammatory lesions. The aim of this retrospective study was to assess whether intravenous contrast is needed to depict inflammatory lesions in bowel magnetic resonance imaging if DWI is available. MATERIALS AND METHODS: Thirty-seven patients (23 females, 14 males; mean age, 14.6 years) underwent MRC on a 1.5-T scanner (MAGNETOM Avanto; Siemens). Contrast-enhanced T1-weighted (ce-T1-w) sequences and DWI sequences in axial and coronal planes (b = 50, 500, 1000) were acquired. Two reviewers evaluated (1) DWI, (2) ce-T1-w MRC, as well as (3) DWI and ce-T1-w MRC concerning lesion conspicuity. The preferred b value was assessed. Colonoscopy was performed within 1 week, including biopsies serving as the reference standard. Sensitivities and specificities were calculated, and interobserver variability was assessed. RESULTS: Mean sensitivity and specificity of the 2 readers for the depiction of inflammatory lesions were 78.4%/100% using ce-T1-w MRC, 95.2%/100% using DWI, and 93.5%/100% combining both imaging techniques compared with colonoscopy including results of the histopathological samples. In 6 patients, inflammatory lesions were only detected by DWI; in another 6 patients, DWI detected additional lesions. The κ values for the 2 readers were excellent (k = 0.92-0.96). The preferred b value with the best detectability of the lesion was b1000 in 28 of the 30 patients (93.3%) with restricted diffusion. CONCLUSIONS: Diffusion-weighted imaging of the bowel identified inflammatory lesions with high accuracy and revealed lesions that were not detectable with ce-T1-w imaging alone. A b value of 1000 showed the best lesion detectability.


Assuntos
Colo/patologia , Meios de Contraste/administração & dosagem , Aumento da Imagem/métodos , Doenças Inflamatórias Intestinais/diagnóstico , Imageamento por Ressonância Magnética/métodos , Procedimentos Desnecessários/estatística & dados numéricos , Adolescente , Adulto , Criança , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Injeções Intravenosas , Masculino , Variações Dependentes do Observador , Compostos Organometálicos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
15.
Eur J Nucl Med Mol Imaging ; 42(1): 56-65, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25223420

RESUMO

PURPOSE: To evaluate the diagnostic potential of PET/MRI with [(18)F]FDG in recurrent ovarian and cervical cancer in comparison to PET/CT. METHODS: A group of 19 patients with suspected recurrence of pelvic malignancies (ovarian cancer, 11 patients; cervical cancer, 8 patients) scheduled for an [(18)F]FDG PET/CT were subsequently enrolled for a PET/MRI. The scan protocol comprised: (1) a T1-W axial VIBE after contrast agent adminstration, (2) an axial T2-W HASTE, (3) a coronal TIRM, (4) an axial DWI, and dedicated MR sequences of the female pelvis including (5) a T1-W VIBE before contrast agent adminstration, (6) a sagittal T2-W TSE, and (7) a sagittal T1-W dynamic VIBE. The datasets (PET/CT, PET/MRI) were rated separately by two readers regarding lesion count, lesion localization, lesion conspicuity (four-point scale), lesion characterization (benign/malignant/indeterminate) and diagnostic confidence (three-point scale). All available data (histology, prior examinations, PET/CT, PET/MRI, follow-up examinations) served as standard of reference. Median values were compared using the Wilcoxon rank sum test. RESULTS: Metastatic lesions were present in 16 of the 19 patients. A total of 78 lesions (malignant, 58; benign, 20) were described. Both PET/CT and PET/MRI allowed correct identification of all malignant lesions and provided equivalent conspicuity (3.86 ± 0.35 for PET/CT, 3.91 ± 0.28 for PET/MRI; p > 0.05). Diagnostic confidence was significantly higher for PET/MRI in malignant (p < 0.01) and benign lesions (p < 0.05). CONCLUSION: Both PET/CT and PET/MRI offer an equivalently high diagnostic value for recurrent pelvic malignancies. PET/MRI offers higher diagnostic confidence in the discrimination of benign and malignant lesions. Considering the reduced radiation dose and superior lesion discrimination, PET/MRI may serve as a powerful alternative to PET/CT in the future.


Assuntos
Carcinoma/diagnóstico por imagem , Imageamento por Ressonância Magnética , Neoplasias Ovarianas/diagnóstico por imagem , Neoplasias Pélvicas/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Neoplasias do Colo do Útero/diagnóstico por imagem , Adulto , Idoso , Carcinoma/patologia , Feminino , Fluordesoxiglucose F18 , Humanos , Metástase Linfática/diagnóstico por imagem , Pessoa de Meia-Idade , Imagem Multimodal , Estadiamento de Neoplasias , Neoplasias Ovarianas/patologia , Neoplasias Pélvicas/secundário , Compostos Radiofarmacêuticos , Neoplasias do Colo do Útero/patologia , Imagem Corporal Total
16.
J Magn Reson Imaging ; 42(3): 624-33, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25522716

RESUMO

BACKGROUND: To evaluate the feasibility of 3 Tesla (T) high-resolution and gadolinium enhanced MRI of cartilage (dGEMRIC) in the thin and rounded hip cartilage of patients after acetabular matrix-based autologous chondrocyte transplantation (MACT). METHODS: Under general ethics approval, 24 patients were prospectively examined 6-31 months after acetabular MACT at 3T using high-resolution proton-density weighted (PDw) images (bilateral PD SPACE, 0.8 mm isotropic; unilateral PD-TSE coronal/sagittal, 0.8 × 0.8 resp. 0.5 × 0.5 × 2.5 mm) as well as T1 mapping (3D-FLASH, 0.78 mm isotropic) in dGEMRIC technique, and clinically scored. The cartilage transplant was evaluated using an adapted MOCART score (maximum 85 points). T1 relaxation times were measured independently by two radiologists. Here, regions of interest were placed manually in automatically calculated relaxation-maps, both in the transplant and adjacent healthy cartilage regions. Interobserver reliability was estimated by means of intraclass-correlation (ICC). RESULTS: The transplant was morphologically definable in the PDw images of 23 patients with a mean MOCART score of 69 points (60-80 points, SD 6.5). T1 maps showed a clear differentiation between acetabular and femoral cartilage, but correlation with PDw images was necessary to identify the transplant. Mean T1 relaxation times of the transplant were 616.3 ms (observer 1) resp. 610.1 ms (observer 2), and of adjacent healthy acetabular cartilage 574.5 ms (observer 1) resp. 604.9 ms (observer 2). Interobserver reliability of the relaxation times in the transplant was excellent (ICC-coefficient 0.88) and in adjacent healthy regions good (0.77). CONCLUSION: High-resolution PDw imaging with adapted MOCART scoring and dGEMRIC is feasible after MACT in the thin and rounded hip cartilage.


Assuntos
Cartilagem Articular/patologia , Condrócitos/transplante , Meios de Contraste/química , Gadolínio/química , Quadril/patologia , Imageamento por Ressonância Magnética , Adulto , Artroscopia , Transplante de Células , Condrócitos/citologia , Estudos de Viabilidade , Feminino , Gadolínio DTPA/química , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
17.
J Magn Reson Imaging ; 42(3): 818-27, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25515676

RESUMO

PURPOSE: To investigate whether additional diffusion-weighted imaging (DWI) improves therapy response evaluation by Gd-EOB magnetic resonance imaging (MRI) in hepatocellular carcinoma (HCC) after radioembolization. MATERIALS AND METHODS: Fifty patients with radioembolization for HCC underwent gadobutrol and Gd-EOB MRI with DWI prior to and 30, 90, and 180 days after radioembolization. A combination of gadobutrol MRI, alpha-fetoprotein, and imaging follow-up served as the reference standard. Two radiologists reviewed Gd-EOB alone (Gd-EOB), DWI alone (DWI), and the combination of both (Gd-EOB+DWI) separately and in consensus using a 4-point-scale: 1 = definitely no tumor progression (TP), 2 = probably no TP, 3 = probably TP, 4 = definitely TP. Receiver operating characteristic (ROC) and kappa analysis were performed. RESULTS: Kappa values for Gd-EOB, DWI, and Gd-EOB+DWI ranged between 0.712 and 0.892 (P < 0.001). 30 days after radioembolization three out of 38 patients showed TP, which was missed by DWI in one case. No significant area under the curve (AUC) difference between Gd-EOB (1.0, P = 0.004), DWI (0.881, P = 0.030), and Gd-EOB+DWI (1.0, P = 0.004) was found (P = 0.320). 90 days after radioembolization six out of 28 patients showed TP, which was detected in one patient only by DWI and Gd-EOB+DWI. The AUC did not differ significantly (P = 0.319) between Gd-EOB (0.890, P = 0.004), DWI (1.0, P < 0.001), and Gd-EOB+DWI (1.0, P < 0.001). 180 days after radioembolization five patients showed TP, which in one case was missed by DWI. The AUC did not differ significantly (P1 = 0.322, P2 = 0.369, P3 = 0.350) between Gd-EOB (1.0, P = 0.003), DWI (0.913, P = 0.016), and Gd-EOB+DWI (0.963, P = 0.007). CONCLUSION: Additional DWI does not substantially improve therapy response evaluation by Gd-EOB MRI in HCC after radioembolization but proved helpful in single cases.


Assuntos
Carcinoma Hepatocelular/terapia , Ablação por Cateter , Imagem de Difusão por Ressonância Magnética , Gadolínio DTPA/química , Neoplasias Hepáticas/terapia , Imageamento por Ressonância Magnética , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/patologia , Meios de Contraste/química , Progressão da Doença , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos/química , Curva ROC , Resultado do Tratamento , alfa-Fetoproteínas/química
18.
J Magn Reson Imaging ; 41(2): 354-60, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24399576

RESUMO

PURPOSE: To develop and implement an automated algorithm for visualizing and quantifying bowel motility using cine magnetic resonance imaging (MRI). MATERIALS AND METHODS: Four healthy volunteers as well as eight patients with suspected or diagnosed inflammatory bowel disease (IBD) underwent MR examinations on a 1.5T scanner. Coronal T2-weighted cine MR images were acquired in healthy volunteers without and with intravenous (i.v.) administration of butylscopolamine. In patients with IBD, cine MRI sequences were collected prior to standard bowel MRI. Bowel motility was assessed using an optical flow algorithm. The resulting motion vector magnitudes were presented as bowel motility maps. Motility changes after i.v. administration of butylscopolamine were measured in healthy volunteers. Inflamed bowel segments in patients were correlated with motility map findings. RESULTS: The acquisition of bowel motility maps was feasible in all subjects examined. In healthy volunteers butylscopolamine led to quantitatively measurable decrease in bowel motility (mean decrease of 59%; P = 0.171). In patients with IBD, visualization of bowel movement by color-coded motility mapping allowed for the detection of segments with abnormal bowel motility. Inflamed bowel segments could be identified by exhibiting a decreased motility. CONCLUSION: Our method is a feasible and promising approach for the assessment of bowel motility disorders.


Assuntos
Motilidade Gastrointestinal/fisiologia , Doenças Inflamatórias Intestinais/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Adolescente , Adulto , Algoritmos , Brometo de Butilescopolamônio , Cor , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Software
19.
Acta Radiol ; 56(8): 1009-15, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25168023

RESUMO

BACKGROUND: Diffusion-weighted imaging (DWI) is routinely used in magnetic resonance imaging (MRI) of prostate cancer. However, the routine use of b values higher than 1000 s/mm(2) is not clear up to present. Moreover, the complex diffusion behavior of malignant and benign prostate tissues hampers precise predictions of contrast in DWI images and apparent diffusion coefficient (ADC) maps. PURPOSE: To quantitatively analyze DWI with different b values in prostate cancer and to identify b values best suitable for cancer detection. MATERIAL AND METHODS: Forty-one patients with histologically proven prostate cancer were examined with high resolution T2-weighted imaging and DWI at 3 Tesla. Five different b values (0, 800, 1000, 1500, 2000 s/mm(2)) were applied. ADC values of tumors and reference areas were measured on ADC maps derived from different pairs of b values. Furthermore, signal intensities of DW images of tumors and reference areas were measured. For analysis, contrast ratios of ADC values and signal intensities of DW images were calculated and compared. RESULTS: No significant differences were found between contrast ratios measured on ADC maps of all analyzed b value pairs (P = 0.43). Contrast ratios calculated from signal intensities of DW images were highest at b values of 1500 and 2000 s/mm(2) and differed significantly from contrast ratios at b values of 800 and 1000 s/mm(2) (P < 0.01). CONCLUSION: Whereas contrast in ADC maps does not significantly change with different b values, contrast ratios of DW images are significantly higher at b-values of 1500 and 2000 s/mm(2) in comparison to b values of 800 and 1000 s/mm(2). Therefore, diagnostic performance of DWI in prostate cancer might be increased by application of b values higher than 1000 s/mm(2).


Assuntos
Algoritmos , Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias da Próstata/patologia , Idoso , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Invest Radiol ; 50(2): 67-72, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25260093

RESUMO

OBJECTIVES: The objective of this study was to evaluate whether the use of automatically generated maps of bowel motility (motility mapping) in magnetic resonance imaging (MRI) leads to an increased detection rate of inflammatory bowel disease. MATERIALS AND METHODS: Fifty consecutive patients with suspected or known inflammatory bowel disease who underwent bowel MRI using a 1.5-T scanner were analyzed retrospectively. In addition to standard small bowel magnetic resonance protocol, a dynamic coronal T2-weighted sequence (dynamic MRI) was acquired. Dynamic sequences were used to automatically generate a parametric map depicting bowel motility. Two readings of the MRI were performed: first, evaluation of static MRI alone and second, evaluation of static MRI combined with dynamic MRI (motility mapping). Static MRI was analyzed on parameters defining inflammation (morphology, enhancement). Dynamic MRI (motility mapping) was evaluated on the basis of a color-coded scheme displaying hypomotility and hypermotility. RESULTS: Using motility maps, additional inflammatory lesions were found in 13 (26%) of the 50 patients, resulting in a significantly higher detection rate using static MRI together with motility mapping compared with static MRI alone (P = 0.0002). Overall, 66 inflammatory lesions of the bowel were detected in a total of 38 patients (static MRI + motility mapping) versus 51 lesions in 34 patients (sole evaluation of static MRI). CONCLUSIONS: Motility assessment of the bowel provides additional information and improves the detection of inflammatory lesions in MRI.


Assuntos
Motilidade Gastrointestinal , Aumento da Imagem/métodos , Doenças Inflamatórias Intestinais/patologia , Doenças Inflamatórias Intestinais/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Técnica de Subtração , Adolescente , Adulto , Idoso , Algoritmos , Criança , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...