Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Plast Reconstr Surg Glob Open ; 12(3): e5652, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38463702

RESUMO

Background: The objective of this meta-analysis was to examine the effectiveness of keloid intralesional excision (KILE) in preventing recurrence. Treatment of keloids using surgical excision alone leads to high rates of recurrence. To date, there are no widely accepted guidelines for keloid treatment, and a multitude of adjunctive therapies are used to reduce recurrence. Despite these efforts, recurrence remains high. In this study, we conducted a meta-analysis of the existing literature on KILE to determine its role in recurrence reduction. Methods: A literature review using PubMed, Scopus, and Web of Science databases was performed. Two authors independently evaluated studies for eligibility. Incidence of keloid recurrence was recorded, and a comprehensive meta-analysis was performed to assess the pooled keloid recurrence rate, as well as the effect of additional therapies. Results: Twenty-two studies evaluating intralesional excision of 608 keloids were included in the study. Average time to follow-up was 19.2 months (range 6-35 months). A meta-analysis of proportions was conducted, demonstrating a pooled recurrence rate of 13% (95% confidence interval, 9%-16%). There was no evidence that using therapies in addition to KILE had a significant effect on the overall pooled recurrence rate. Conclusions: A meta-analysis of 608 keloids shows that KILE is an effective technique in preventing keloid recurrence, with a pooled recurrence rate of 13% compared with previously reported rates of 45%-100% after complete excision. Although there are no standard guidelines for keloid treatment, our meta-analysis shows that KILE is promising in recurrence reduction.

3.
J Am Coll Radiol ; 20(2): 193-204, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35988585

RESUMO

OBJECTIVE: There is a paucity of utility and cost data regarding the launch of 3D printing in a hospital. The objective of this project is to benchmark utility and costs for radiology-based in-hospital 3D printing of anatomic models in a single, adult academic hospital. METHODS: All consecutive patients for whom 3D printed anatomic models were requested during the first year of operation were included. All 3D printing activities were documented by the 3D printing faculty and referring specialists. For patients who underwent a procedure informed by 3D printing, clinical utility was determined by the specialist who requested the model. A new metric for utility termed Anatomic Model Utility Points with range 0 (lowest utility) to 500 (highest utility) was derived from the specialist answers to Likert statements. Costs expressed in United States dollars were tallied from all 3D printing human resources and overhead. Total costs, focused costs, and outsourced costs were estimated. The specialist estimated the procedure room time saved from the 3D printed model. The time saved was converted to dollars using hospital procedure room costs. RESULTS: The 78 patients referred for 3D printed anatomic models included 11 clinical indications. For the 68 patients who had a procedure, the anatomic model utility points had an overall mean (SD) of 312 (57) per patient (range, 200-450 points). The total operation cost was $213,450. The total cost, focused costs, and outsourced costs were $2,737, $2,180, and $2,467 per model, respectively. Estimated procedure time saved had a mean (SD) of 29.9 (12.1) min (range, 0-60 min). The hospital procedure room cost per minute was $97 (theoretical $2,900 per patient saved with model). DISCUSSION: Utility and cost benchmarks for anatomic models 3D printed in a hospital can inform health care budgets. Realizing pecuniary benefit from the procedure time saved requires future research.


Assuntos
Impressão Tridimensional , Radiologia , Adulto , Humanos , Tomografia Computadorizada por Raios X , Modelos Anatômicos , Hospitais
4.
J Neural Eng ; 18(4)2021 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-34359056

RESUMO

Background. Robotic exoskeleton devices have become a promising modality for restoration of extremity function in individuals with limb loss or functional weakness. However, there exists no consistent or reliable way to record efferent motor action potentials from intact peripheral nerves to control device movement. Peripheral nerve motor action potentials are similar in amplitude to that of background noise, producing an unfavorable signal-to-noise ratio (SNR) that makes these signals difficult to detect and interpret. To address this issue, we have developed the muscle cuff regenerative peripheral nerve interface (MC-RPNI), a construct consisting of a free skeletal muscle graft wrapped circumferentially around an intact peripheral nerve. Over time, the muscle graft regenerates, and the intact nerve undergoes collateral axonal sprouting to reinnervate the muscle. The MC-RPNI amplifies efferent motor action potentials by several magnitudes, thereby increasing the SNR, allowing for higher fidelity signaling and detection of motor intention. The goal of this study was to characterize the signaling capabilities and viability of the MC-RPNI over time.Methods. Thirty-seven rats were randomly assigned to one of five experimental groups (Groups A-E). For MC-RPNI animals, their contralateral extensor digitorum longus (EDL) muscle was harvested and trimmed to either 8 mm (Group A) or 13 mm (Group B) in length, wrapped circumferentially around the intact ipsilateral common peroneal (CP) nerve, secured, and allowed to heal for 3 months. Additionally, one 8 mm (Group C) and one 13 mm (Group D) length group had an epineurial window created in the CP nerve immediately preceding MC-RPNI creation. Group E consisted of sham surgery animals. At 3 months, electrophysiologic analyses were conducted to determine the signaling capabilities of the MC-RPNI. Additionally, electromyography and isometric force analyses were performed on the CP-innervated EDL to determine the effects of the MC-RPNI on end organ function. Following evaluation, the CP nerve, MC-RPNI, and ipsilateral EDL muscle were harvested for histomorphometric analysis.Results. Study endpoint analysis was performed at 3 months post-surgery. All rats displayed visible muscle contractions in both the MC-RPNI and EDL following proximal CP nerve stimulation. Compound muscle action potentials were recorded from the MC-RPNI following proximal CP nerve stimulation and ranged from 3.67 ± 0.58 mV to 6.04 ± 1.01 mV, providing efferent motor action potential amplification of 10-20 times that of a normal physiologic nerve action potential. Maximum tetanic isometric force (Fo) testing of the distally-innervated EDL muscle in MC-RPNI groups producedFo(2341 ± 114 mN-2832 ± 102 mN) similar to controls (2497 ± 122 mN), thus demonstrating that creation of MC-RPNIs did not adversely impact the function of the distally-innervated EDL muscle. Overall, comparison between all MC-RPNI sub-groups did not reveal any statistically significant differences in signaling capabilities or negative effects on distal-innervated muscle function as compared to the control group.Conclusions. MC-RPNIs have the capability to provide efferent motor action potential amplification from intact nerves without adversely impacting distal muscle function. Neither the size of the muscle graft nor the presence of an epineurial window in the nerve had any significant impact on the ability of the MC-RPNI to amplify efferent motor action potentials from intact nerves. These results support the potential for the MC-RPNI to serve as a biologic nerve interface to control advanced exoskeleton devices.


Assuntos
Regeneração Nervosa , Nervos Periféricos , Animais , Eletromiografia , Contração Muscular , Músculo Esquelético , Ratos , Ratos Endogâmicos F344
5.
Med Phys ; 48(6): 3223-3233, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33733499

RESUMO

PURPOSE: The dimensional accuracy of three-dimensional (3D) printed anatomical models is essential to correctly understand spatial relationships and enable safe presurgical planning. Most recent accuracy studies focused on 3D printing of a single pathology for surgical planning. This study evaluated the accuracy of medical models across multiple pathologies, using desktop inverted vat photopolymerization (VP) to 3D print anatomic models using both rigid and elastic materials. METHODS: In the primary study, we 3D printed seven models (six anatomic models and one reference cube) with volumes ranging from ~2 to ~209 cc. The anatomic models spanned multiple pathologies (neurological, cardiovascular, abdominal, musculoskeletal). Two solid measurement landing blocks were strategically created around the pathology to allow high-resolution measurement using a digital micrometer and/or caliper. The physical measurements were compared to the designed dimensions, and further analysis was conducted regarding the observed patterns in accuracy. All of the models were printed in three resins: Elastic, Clear, and Grey Pro in the primary experiments. A full factorial block experimental design was employed and a total of 42 models were 3D printed in 21 print runs. In the secondary study, we 3D printed two of the anatomic models in triplicates selected from the previous six to evaluate the effect of 0.1 mm vs 0.05 mm layer height on the accuracy. RESULTS: In the primary experiment, all dimensional errors were less than 1 mm. The average dimensional error across the 42 models was 0.238  ±  0.219 mm and the relative error was 1.10  ±  1.13%. Results from the secondary experiments were similar with an average dimensional error of 0.252  ±  0.213 mm and relative error of 1.52%  ±  1.28% across 18 models. There was a statistically significant difference in the relative errors between the Elastic resin and Clear resin groups. We explained this difference by evaluating inverted VP 3D printing peel forces. There was a significant difference between the Solid and Hollow group of models. There was a significant difference between measurement landing blocks oriented Horizontally and Vertically. In the secondary experiments, there was no difference in accuracy between the 0.10 and 0.05 mm layer heights. CONCLUSIONS: The maximum measured error was less than 1 mm across all models, and the mean error was less than 0.26mm. Therefore, inverted VP 3D printing technology is suitable for medical 3D printing if 1 mm is considered the cutoff for clinical use cases. The 0.1 mm layer height is suitable for 3D printing accurate anatomical models for presurgical planning in a majority of cases. Elastic models, models oriented horizontally, and models that are hollow tend to have relatively higher deviation as seen from experimental results and mathematical model predictions. While clinically insignificant using a 1 mm cutoff, further research is needed to better understand the complex physical interactions in VP 3D printing which influence model accuracy.


Assuntos
Modelos Anatômicos , Impressão Tridimensional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...