Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Radiologie (Heidelb) ; 2024 May 13.
Artigo em Alemão | MEDLINE | ID: mdl-38739177

RESUMO

BACKGROUND: Since 2003, a decline in the age-standardized incidence rates of colorectal cancer (CRC) has been observed in Germany. Nonetheless, one in eight cancer cases still affects the colon or rectum. The prognosis has improved, with the relative 5­year survival rate for CRC being approximately 65%. METHODS: This positive trend is probably a result of preventive measures introduced over the last 20 years. This could be further improved, however, as CRC can not only be detected early but in almost all cases also prevented through the identification of benign precursors. Less than half of all eligible individuals participate in screening via colonoscopy. This implies that further, possibly even imaging, screening test methods should be explored and offered. Studies have reported that virtual colonography techniques have a comparable accuracy to endoscopy of about 90% for polyp sizes larger than 5 mm. The data for computed tomography (CT) is more extensive than for magnetic resonance imaging (MRI). CONCLUSION: Significant challenges are posed however by the fact that in Germany CT colonography (CTC) is not considered a viable screening option due to radiation protection concerns, and MRI screening is not an established screening method. Radiologists should be familiar with classification using the CT Colonography Reporting and Data System (C-RADS), which uses criteria such as CT density, morphology, size, and location for classification. C­RADS classification follows the categories: C0 (inadequate study), C1 (normal), C2a (indeterminate), C2b (benign), C3 (suspicious), and C4 (malignant), as well as extracolonic categories E1/2 (no clinically significant findings), E3 (likely insignificant findings), and E4 (likely significant findings).

2.
Radiologie (Heidelb) ; 64(4): 321-332, 2024 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-38502373

RESUMO

Radiology plays a key role in the diagnosis and monitoring of hepatocellular carcinoma (HCC). Ultrasound, computed tomography (CT) and magnetic resonance imaging (MRI) are used to identify HCC lesions. Multiparametric MRI provides detailed insights into the tumor biology through the analysis of morphology, perfusion and diffusion. In this way preoperative decisions can be optimized. The guidelines recommend using contrast-enhanced MRI or ultrasound for the diagnosis of HCC. The preferred method is MRI due to its superiority in the detection of small lesions The treatment response is evaluated using modified response evaluation criteria for solid tumors (RECIST) and the European Association for the Study of the Liver (EASL) criteria. The use of multiparametric MRI in conjunction with the liver imaging reporting and data system (LI-RADS) plays overall a central role in the precise diagnosis and monitoring of the treatment of HCC.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Imageamento por Ressonância Magnética Multiparamétrica , Humanos , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/cirurgia , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Perfusão , Imagem de Perfusão
3.
Rofo ; 192(7): 641-656, 2020 Jul.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-32615626

RESUMO

BACKGROUND: Radiological reports of pancreatic lesions are currently widely formulated as free texts. However, for optimal characterization, staging and operation planning, a wide range of information is required but is sometimes not captured comprehensively. Structured reporting offers the potential for improvement in terms of completeness, reproducibility and clarity of interdisciplinary communication. METHOD: Interdisciplinary consensus finding of structured report templates for solid and cystic pancreatic tumors in computed tomography (CT) and magnetic resonance imaging (MRI) with representatives of the German Society of Radiology (DRG), German Society for General and Visceral Surgery (DGAV), working group Oncological Imaging (ABO) of the German Cancer Society (DKG) and other radiologists, oncologists and surgeons. RESULTS: Among experts in the field of pancreatic imaging, oncology and pancreatic surgery, as well as in a public online survey, structured report templates were developed by consensus. These templates are available on the DRG homepage under www.befundung.drg.de and will be regularly revised to the current state of scientific knowledge by the participating specialist societies and responsible working groups. CONCLUSION: This article presents structured report templates for solid and cystic pancreatic tumors to improve clinical staging (cTNM, ycTNM) in everyday radiology. KEY POINTS: · Structured report templates offer the potential of optimized radiological reporting with regard to completeness, reproducibility and differential diagnosis.. · This article presents consensus-based, structured reports for solid and cystic pancreatic lesions in CT and MRI.. · These structured reports are available open source on the homepage of the German Society of Radiology (DRG) under www.befundung.drg.de.. CITATION FORMAT: · Persigehl T, Baumhauer M, Baeßler B et al. Structured Reporting of Solid and Cystic Pancreatic Lesions in CT and MRI: Consensus-Based Structured Report Templates of the German Society of Radiology (DRG). Fortschr Röntgenstr 2020; 192: 641 - 655.


Assuntos
Imageamento por Ressonância Magnética/métodos , Cisto Pancreático/diagnóstico por imagem , Pancreatopatias/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Sistemas de Informação em Radiologia , Projetos de Pesquisa , Tomografia Computadorizada por Raios X/métodos , Alemanha , Humanos , Radiologia , Sociedades Médicas
4.
Rofo ; 192(5): 458-470, 2020 May.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-31918440

RESUMO

PURPOSE: Good training is the basis for high job satisfaction and high-quality patient care in radiology. The aim of this survey was to record the current state of working conditions for residents in radiology training in Germany and to focus on the aspects of training and psychosocial workload. The description of the actual state should help to identify possible problem areas and to develop improvement approaches. MATERIALS AND METHODS: At the beginning of 2018, we sent an electronic questionnaire to the German Roentgen Society (DRG), the German Association of Chairmen in Academic Radiology (KLR), the Chief Physician Forum of the DRG (CAFRAD) and the Forum of Registered Radiologists (FUNRAD) with the request to forward it to radiology residents. With 63 questions, the questionnaire covered seven essential areas of medical working and training conditions. In order to ensure interdisciplinary comparability, most questions were identical to previous surveys among residents of other disciplines. RESULTS: 643 residents started the survey. 501 (78 %) questionnaires were fully processed and included in the final analysis. 65 % of respondents were satisfied with their current job situation. At the same time, shortcomings, especially with regard to the reconciliation of family and work as well as scientific and clinical work, became clear. Only 36 % of participants with children were satisfied with the compatibility of family and work at their workplace. Only 31 % of the researchers were satisfied with their research conditions. In addition, residents experienced a high psychosocial workload. CONCLUSION: Job satisfaction is high among radiology residents in direct comparison to other disciplines. However, based on this survey, adjustments to working conditions and training in radiology seem necessary to maintain the health of the physicians concerned, to encourage motivation for scientific work and to enhance development opportunities, especially for women, through a better compatibility of work and family life. The present survey identifies strategies and leadership tools that can help to achieve this. KEY POINTS: Residents in radiology training ... · have a relatively high job satisfaction.. · experience a high psychosocial workload.. · evaluate the compatibility of family and work as in need of improvement.. · are interested in research, but evaluate research conditions as insufficient. CITATION FORMAT: · Oechtering TH, Panagiotopoulos N, Völker M et al. Work and Training Conditions of German Residents in Radiology - Results from a Nationwide Survey Conducted by the Young Radiology Forum in the German Roentgen Society. Fortschr Röntgenstr 2020; 192: 458 - 469.


Assuntos
Capacitação em Serviço , Internato e Residência , Satisfação no Emprego , Radiologia/educação , Carga de Trabalho , Adulto , Currículo , Feminino , Alemanha , Humanos , Masculino , Motivação , Qualidade de Vida , Sociedades Médicas , Inquéritos e Questionários , Equilíbrio Trabalho-Vida
5.
Rofo ; 190(4): 341-347, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29448290

RESUMO

PURPOSE: To assess the interrater agreement and reliability of experienced abdominal radiologists in the characterization and grading of arterial phase gadoxetate disodium-related respiratory motion artifact on liver MRI. MATERIALS AND METHODS: This prospective multicenter study was initiated by the working group for abdominal imaging within the German Roentgen Society (DRG), and approved by the local IRB of each participating center. 11 board-certified radiologists independently reviewed 40 gadoxetate disodium-enhanced liver MRI datasets. Motion artifacts in the arterial phase were assessed on a 5-point scale. Interrater agreement and reliability were calculated using the intraclass correlation coefficient (ICC) and Kendall coefficient of concordance (W), with p < 0.05 deemed significant. RESULTS: The ICC for interrater agreement and reliability were 0.983 (CI 0.973 - 0.990) and 0.985 (CI 0.978 - 0.991), respectively (both p < 0.0001), indicating excellent agreement and reliability. Kendall's W for interrater agreement was 0.865. A severe motion artifact, defined as a mean motion score ≥ 4 in the arterial phase was observed in 12 patients. In these specific cases, a motion score ≥ 4 was assigned by all readers in 75 % (n = 9/12 cases). CONCLUSION: Differentiation and grading of arterial phase respiratory motion artifact is possible with a high level of inter-/intrarater agreement and interrater reliability, which is crucial for assessing the incidence of this phenomenon in larger multicenter studies. KEY POINTS: · Inter- and intrarater agreement for motion artifact scoring is excellent among experienced readers.. · Interrater reliability for motion artifact scoring is excellent among experienced readers.. · Characterization of severe motion artifacts proved feasible in this multicenter study.. CITATION FORMAT: · Ringe KI, Luetkens JA, Fimmers R et al. Characterization of Severe Arterial Phase Respiratory Motion Artifact on Gadoxetate Disodium-Enhanced MRI - Assessment of Interrater Agreement and Reliability. Fortschr Röntgenstr 2017; 190: 341 - 347.


Assuntos
Artefatos , Gadolínio DTPA/farmacocinética , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Radiologistas/normas , Mecânica Respiratória/fisiologia , Atitude do Pessoal de Saúde , Gadolínio DTPA/administração & dosagem , Alemanha , Injeções Intravenosas , Variações Dependentes do Observador , Estudos Prospectivos , Fluxo Pulsátil/fisiologia , Reprodutibilidade dos Testes , Suíça
7.
J Interv Card Electrophysiol ; 28(2): 109-16, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20198505

RESUMO

PURPOSE: The aim of the study was to evaluate the incidence of ventricular arrhythmia and clinical outcome in patients receiving a cardiac resynchronization therapy (CRT) depending on the left ventricular (LV) lead position. METHODS: A total of 187 consecutive patients with advanced heart failure who received a CRT-implantable cardioverter defibrillator were analyzed. Forty patients (21%) had a LV lead in the anterior/apical (anterior) and 147 patients (79%) in the posterior/posterolateral (posterior) region. The total median follow-up time was 644 days. RESULTS: The incidence of ventricular arrhythmia was 35% in patients with an anterior LV lead versus 30% in patients with a posterior LV lead (p = 0.53). The 1- and 2-year mortality in the anterior LV lead group was 19% and 22%, as compared with 0.7% and 3.2%, respectively, in the posterior LV lead group (p < 0.001). In a multivariable analysis, an anterior LV lead was independently associated with an increased mortality (hazard ratio 5.88, 95% confidence interval 2.22-16.67). The major cause of death was end-stage heart failure whereas the incidence of sudden cardiac death was not different between both groups. CONCLUSIONS: Thus, biventricular pacing with an anterior LV lead seems to have no impact on the incidence of ventricular arrhythmia but may be associated with an increased mortality rate due to worsening heart failure.


Assuntos
Arritmias Cardíacas/epidemiologia , Terapia de Ressincronização Cardíaca , Eletrodos Implantados , Ventrículos do Coração , Idoso , Angiografia Coronária , Feminino , Humanos , Incidência , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Sistema de Registros , Estatísticas não Paramétricas
8.
Clin Res Cardiol ; 97(9): 623-7, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18677436

RESUMO

BACKGROUND: The aim was to assess clinical, angiographic and cardiovascular magnetic resonance (CMR) findings in patients with Takotsubo cardiomyopathy. METHODS: Between 2003 and 2007, 20 consecutive patients admitted to our hospital with suspected acute myocardial infarction and presenting with apical ballooning in the left ventricular (LV) angiogram in the absence of a significant coronary artery disease, were included in the study. Echocardiography and CMR was performed in all patients. RESULTS: The mean age of patients with Takotsubo cardiomyopathy was 62 +/- 8 years (range 43-78 years). Eighteen (90%) were female. Clinical presentations included chest pain (95%) and cardiogenic shock (5%). The mean angiographic LV ejection fraction on admission was 45% +/- 9% (range 26%-60%) and resolved rapidly in all cases. Mean time delay between presentation CMR was 2 +/- 1 days (range 1-6 days). Mean ejection fraction was 51% +/- 15% (range 25%-81%). While 19 (95%) patients showed no evidence of late enhancement or signs of myocarditis in the CMR, 1 (5%) patient who was resuscitated showed hyperenhancement confined to the apex. CONCLUSION: In patients showing the clinical picture of an acute myocardial syndrome and angiographic picture of a TakoTsubo cardiomyopathy, CMR might be helpful in confirming the diagnosis through the exclusion of other causes for the acute LV dysfunction.


Assuntos
Angiografia Coronária/métodos , Imageamento por Ressonância Magnética/métodos , Cardiomiopatia de Takotsubo/diagnóstico , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Scand J Gastroenterol ; 41(7): 826-32, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16785196

RESUMO

OBJECTIVE: To examine the relationship of both the unstimulated and the postprandial portal blood flow (PVF) to the time of day and to determine its intra-individual reproducibility over time in patients with liver cirrhosis. MATERIAL AND METHODS: In 24 cirrhotic patients, 27 PVF measurements were performed during 24 h on day 0 and day 7 using Doppler ultrasound. Three standard liquid meals were given orally. On day 7, the baseline hepatic venous pressure gradient (HVPG) was also measured. RESULTS: Circadian area under the time curve of PVF was highly reproducible within individuals (r=0.959, p<0.001). It did not correlate with HVPG. Cosinor analysis showed a significant circadian rhythm of PVF (acrophase at 11:44 and amplitude of 9.44%). Maximal postprandial increase in PVF was significantly higher in the morning than at noon or in the evening. CONCLUSIONS: PVF is subject to a circadian rhythm and postprandial portal hyperemia shows a diurnal variability. Both are highly reproducible.


Assuntos
Ritmo Circadiano/fisiologia , Jejum/fisiologia , Circulação Hepática/fisiologia , Cirrose Hepática/metabolismo , Período Pós-Prandial/fisiologia , Humanos , Hipertensão Portal
11.
Radiology ; 238(1): 143-9, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16304088

RESUMO

PURPOSE: To prospectively compare dark-lumen magnetic resonance (MR) colonography with conventional colonoscopy in the detection of colorectal polyps. MATERIALS AND METHODS: Local ethical committee approval and informed consent were obtained. One hundred consecutive patients (56 men, 44 women; mean age +/- standard deviation, 67.7 years +/- 14.7; range, 25-82 years) who were referred for conventional colonoscopy from January 2003 to January 2004 underwent MR colonography and conventional colonoscopy after standard precolonoscopic bowel cleansing. Colonoscopy was performed immediately after MR colonography. For MR colonography, the colon was filled with approximately 2000 mL of tap water. Imaging was performed with a 1.5-T MR unit with patients in the prone position. A T1-weighted three-dimensional volumetric interpolated breath-hold sequence was performed before and 75 seconds after intravenous administration of 0.2 mmol gadobenate dimeglumine per kilogram of body weight. Results of MR colonography were analyzed on a per-polyp and per-patient basis. Findings at colonoscopy were used as the reference for determining accuracy, sensitivity, specificity, and positive and negative predictive values of MR colonography. RESULTS: Of 100 patients recruited for study, 92 (52 men, 40 women; mean age, 61.5 years +/- 14.5; range, 25-82 years) underwent complete MR and conventional colonoscopy examinations. Forty-three of the 92 patients (47%) had normal findings at conventional colonoscopy. In the other 49 patients (53%), conventional colonoscopy depicted 107 polyps (82 adenomas, 25 hyperplastic polyps) and seven carcinomas. At per-polyp analysis, sensitivity of MR colonography in the detection of adenomatous polyps was 100% for polyps at least 10 mm in diameter and 84.2% for polyps 6-9 mm in diameter. At per-patient analysis, the accuracy of MR colonography was 93.1% (sensitivity, 89%; specificity, 96%) if detection of adenomatous polyps of all sizes was considered. CONCLUSION: Dark-lumen MR colonography is a promising modality with high accuracy for detecting colorectal polyps larger than 5 mm in diameter.


Assuntos
Pólipos do Colo/diagnóstico , Colonoscopia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/administração & dosagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Meglumina/administração & dosagem , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Compostos Organometálicos/administração & dosagem , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade
12.
Med Klin (Munich) ; 100(2): 115-22, 2005 Feb 15.
Artigo em Alemão | MEDLINE | ID: mdl-15711908

RESUMO

Magnetic resonance imaging (MRI) has been called the most important development in medical diagnosis since the discovery of the X-ray more than 100 years ago. The effectiveness of MRI has been expanded to a variety of gastrointestinal disorders. The gastroenterologist's attention is currently focused on biliopancreatic and bowel diseases. Magnetic resonance cholangiopancreatography (MRCP) has become a competitive replacement for diagnostic endoscopic retrograde cholangiopancreatography (ERCP) in a variety of hepatobiliary and pancreatic diseases. MR enteroscopy has the potential to become the preferred method for evaluating the entire small bowel, while on the other hand virtual colonoscopy is far from being promoted as a tool for general screening purposes in suspected colon diseases. In summary, whether or not the survival of endoscopy is under debate, MRI could mark a historic turning point in gastroenterology. So, MRI hardware might interdisciplinarily be used by, e. g., radiologists and gastroenterologists.


Assuntos
Doenças do Sistema Digestório/diagnóstico , Gastroenteropatias/diagnóstico , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Colangiopancreatografia Retrógrada Endoscópica , Colangiopancreatografia por Ressonância Magnética , Colonografia Tomográfica Computadorizada , Humanos , Sensibilidade e Especificidade
13.
Dig Dis ; 22(1): 18-25, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15292691

RESUMO

The introduction of endoscopic retrograde cholangiopancreatography (ERCP) in the early 1970s provided gastroenterologists with a number of diagnostic as well as therapeutic possibilities for examining biliopancreatic systems. In the meantime, magnetic resonance cholangiopancreatography presents a non-invasive alternative to diagnostic ECRP providing the advantage of a lower rate of possible complications. This article addresses the two methods presently available for differentiating pancreatic tumors. The objective of this article is to describe the advantages and disadvantages as well as the possibilities inherent in both methods.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica/métodos , Imageamento por Ressonância Magnética/métodos , Pâncreas/patologia , Neoplasias Pancreáticas/diagnóstico , Adenoma de Células das Ilhotas Pancreáticas/diagnóstico por imagem , Adenoma de Células das Ilhotas Pancreáticas/patologia , Cistadenoma Mucinoso/diagnóstico por imagem , Cistadenoma Mucinoso/patologia , Diagnóstico Diferencial , Endoscopia do Sistema Digestório/métodos , Feminino , Humanos , Masculino , Sensibilidade e Especificidade
14.
Gastrointest Endosc ; 57(7): 860-7, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12776033

RESUMO

BACKGROUND: The combination of photodynamic therapy and biliary drainage by plastic endoprosthesis insertion has produced promising results in the treatment of nonresectable hilar cholangiocarcinoma. The feasibility and efficacy of intraductal photodynamic therapy with subsequent biliary drainage by self-expandable metal stent insertion were evaluated in a prospective phase II study. METHODS: Twenty-four patients were treated with photodynamic therapy after sensitization with porfimer sodium. A plastic endoprosthesis was inserted immediately thereafter and replaced by a metal stent 4 weeks later. A retrospectively analyzed group of 20 patients treated only with biliary drainage served as a historical control group. RESULTS: In 19 of the 24 patients, insertion of a metal stent was technically feasible. The 30-day and 60-day mortality rates were 0%. A significant decrease in serum bilirubin was noted in all patients and quality of life remained stable throughout follow-up. Mean and median survival were, respectively, 15.9(3.1) and 9.9: 95% CI [6.4, 13.4] months after photodynamic therapy. In the control group, mean and median survival were, respectively, 12.5(3.4) and 5.6: 95% CI [3.7, 7.6] months, which was not statistically significantly different from the photodynamic therapy group. CONCLUSIONS: Photodynamic therapy with consecutive biliary drainage by insertion of a self-expandable metal stent is feasible. With respect to the small benefit in overall survival, randomized controlled trials are warranted.


Assuntos
Neoplasias dos Ductos Biliares/terapia , Ductos Biliares Intra-Hepáticos , Colangiocarcinoma/terapia , Cuidados Paliativos , Fotoquimioterapia , Stents , Idoso , Neoplasias dos Ductos Biliares/tratamento farmacológico , Neoplasias dos Ductos Biliares/mortalidade , Colangiocarcinoma/tratamento farmacológico , Colangiocarcinoma/mortalidade , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
15.
Lancet ; 361(9365): 1241-6, 2003 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-12699950

RESUMO

BACKGROUND: In most patients, severity of valvular aortic stenosis can be accurately assessed non-invasively by echocardiography. However, retrograde catheterisation of the aortic valve is often undertaken. This procedure has a potential risk of neurological complications, with an unknown incidence of clinically silent embolism. We aimed to establish the frequency of clinically apparent and silent cerebral embolism after this procedure. METHODS: We prospectively randomised 152 consecutive patients with valvular aortic stenosis at a German university hospital to receive either cardiac catheterisation with (n=101) or without (n=51) passage through the aortic valve. Patients underwent cranial MRI and neurological assessment within 48 h before and after the procedure to assess cerebral embolism. Controls were 32 patients without valvular aortic stenosis who underwent coronary angiography and laevocardiography. FINDINGS: 22 of 101 patients (22%) who underwent retrograde catheterisation of the aortic valve had focal diffusion-imaging abnormalities in a pattern consistent with acute cerebral embolic events after the procedure; three of these patients (3%) had clinically apparent neurological deficits. By contrast, none of the patients without passage of the valve, or any of the controls, had evidence of cerebral embolism as assessed by MRI. INTERPRETATION: Patients with valvular aortic stenosis who undergo retrograde catheterisation of the aortic valve have a substantial risk of clinically apparent cerebral embolism, and frequently have silent ischaemic brain lesions. Patients should be informed about these risks, and this procedure should be used only in patients with unclear echocardiographical findings when additional information is necessary for clinical management.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Valva Aórtica , Cateterismo Cardíaco/efeitos adversos , Embolia Intracraniana/etiologia , Valva Aórtica/fisiopatologia , Encéfalo/patologia , Cateterismo Cardíaco/métodos , Imagem de Difusão por Ressonância Magnética , Humanos , Embolia Intracraniana/diagnóstico , Pressão , Estudos Prospectivos , Fatores de Risco
16.
AJR Am J Roentgenol ; 178(1): 61-5, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11756088

RESUMO

OBJECTIVE: This study was undertaken to investigate to what extent continuous infusion of a galactose-based microbubble contrast agent (Levovist) allows evaluation of the portal vascular system in patients with portal hypertension and for whom baseline unenhanced color Doppler sonography was nondiagnostic. SUBJECTS AND METHODS: We performed color Doppler sonography at baseline and during IV Levovist infusion (4 g, 300 mg/min). First, we measured the duration of portal vein visualization during Levovist infusion in 15 patients in whom unenhanced color Doppler sonography failed to show the portal confluence from a subcostal view. This duration of improved portal conspicuity was termed "diagnostic window." We then compared in 30 patients enhanced color Doppler sonographic findings with conventional imaging methods, including portography (n = 14), helical CT (n = 4), or gadolinium-enhanced MR angiography (n = 12), and we recorded the investigator's confidence in the color Doppler sonographic result before and after Levovist infusion. RESULTS: The diagnostic window achieved by the Levovist infusion was 13.6 +/- 0.9 min. At baseline, color Doppler sonography was nondiagnostic in 19 patients. The diagnostic confidence level was low in all the remaining 11 patients. During Levovist infusion, color Doppler sonography remained nondiagnostic only in two of 30 patients. The confidence level was low in five patients and high in 23 patients. In 26 of these 28 patients, echo-enhanced color Doppler sonographic findings were confirmed by reference methods. CONCLUSION: The continuous infusion of Levovist achieved a sufficient echo enhancement from the portal vascular bed and allowed a valid diagnostic color Doppler sonographic examination in portal hypertensive patients for whom color Doppler sonography would otherwise be nondiagnostic.


Assuntos
Meios de Contraste/administração & dosagem , Hipertensão Portal/diagnóstico por imagem , Polissacarídeos , Ultrassonografia Doppler em Cores , Adulto , Idoso , Feminino , Humanos , Infusões Intravenosas , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Polissacarídeos/administração & dosagem , Sistema Porta/diagnóstico por imagem , Tomografia Computadorizada por Raios X
17.
Radiology ; 222(1): 73-80, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11756708

RESUMO

PURPOSE: To test the hypothesis that the accuracy of gadolinium- and ferumoxides-enhanced magnetic resonance (MR) imaging is different in small (< or =1.5-cm) and large (>1.5-cm) hepatocellular carcinomas (HCCs). MATERIALS AND METHODS: Forty-three consecutive patients with chronic liver disease were enrolled in this study. The imaging protocol included unenhanced breath-hold T1-weighted fast field-echo sequences, unenhanced respiratory-triggered T2-weighted turbo spin-echo (SE) sequences, dynamic gadolinium-enhanced T1-weighted three-dimensional turbo field-echo sequences, and ferumoxides-enhanced T2-weighted turbo SE sequences. Images of each sequence and two sets of sequences (ferumoxides set and gadolinium set) were reviewed by four observers. The ferumoxides set included unenhanced T1- and T2-weighted images and ferumoxides-enhanced T2-weighted turbo SE MR images. The gadolinium set included unenhanced T1- and T2-weighted images and dynamic gadolinium-enhanced three-dimensional turbo field-echo MR images. In receiver operating characteristic (ROC) curve analysis, the sensitivity and accuracy of the sequences were compared in regard to the detection of all, small, and large HCCs. RESULTS: Imaging performance was different with gadolinium- and ferumoxides-enhanced images in the detection of small and large HCCs. For detection of small HCCs, the sensitivity and accuracy with unenhanced and gadolinium-enhanced imaging (gadolinium set) were significantly (P =.017) superior to those with unenhanced and ferumoxides-enhanced imaging (ferumoxides set). The area under the composite ROC curves, or A(z), for the gadolinium set and the ferumoxides set was 0.97 and 0.81, respectively. For large HCC, the ferumoxides set was superior compared with the gadolinium set, but this difference was not statistically significant. Analysis of all HCCs demonstrated no significant differences for gadolinium- and ferumoxides-enhanced imaging. CONCLUSION: For the detection of early HCC, gadolinium-enhanced MR imaging is preferred to ferumoxides-enhanced MR imaging because the former demonstrated significantly greater accuracy in the detection of small HCCs.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Gadolínio DTPA , Ferro , Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética/métodos , Óxidos , Adulto , Idoso , Meios de Contraste , Dextranos , Diagnóstico Diferencial , Feminino , Óxido Ferroso-Férrico , Humanos , Imageamento por Ressonância Magnética/instrumentação , Nanopartículas de Magnetita , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...