Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Eur J Pharm Sci ; 49(2): 101-8, 2013 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-23459107

RESUMO

Physicochemical coating properties are often considered to be determining factors for in vivo characteristics of superparamagnetic iron oxide nanoparticles, used as contrast agent in Magnetic Resonance Imaging (MRI). To investigate the electrical charge (modified by zero, one or two ammonium groups) and the molecule length (3, 5 or 7 methylene chains) effects of bisphosphonate-type coatings, we assessed the complement activation, in vivo plasma and tissue relaxation time alterations of intravenously injected small iron oxide nanoparticles (<25 nm) on male healthy Wistar rats. The presence of ammonium groups induces a weak activation of the complement whatever the size and the concentration of particles, whereas hydroxyethylenebisphosphonate (HEBP)-coated particles are poor complement activators only at the lowest concentration. In vivo, HEBP-coated nanoparticles have the greatest prolonged relaxation time effects, despite their higher negative electrical charge, contrary to two ammonium bearing coatings. No significant differences were observed between mono-ammonium molecular coatings.


Assuntos
Difosfonatos/administração & dosagem , Compostos Férricos/administração & dosagem , Nanopartículas Metálicas/administração & dosagem , Compostos de Amônio/química , Animais , Ativação do Complemento/efeitos dos fármacos , Difosfonatos/química , Eletroquímica , Compostos Férricos/química , Coração/efeitos dos fármacos , Coração/fisiologia , Rim/efeitos dos fármacos , Rim/fisiologia , Fígado/efeitos dos fármacos , Fígado/fisiologia , Pulmão/efeitos dos fármacos , Pulmão/fisiologia , Fenômenos Magnéticos , Masculino , Nanopartículas Metálicas/química , Ratos , Ratos Wistar , Baço/efeitos dos fármacos , Baço/fisiologia
2.
Biomaterials ; 32(31): 7999-8009, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21788070

RESUMO

The aim of this work was to develop a new microparticulate system able to form a complex with radionuclides with a high yield of purity for diagnostic or therapeutic applications. Owing to its properties potato starch was chosen as starting material and modified by oxidization and coupling of a ligand (polyamine) enabling modified starch to chelate radionuclides. The choice of suitable experiments was based on a combination of a Rechtschaffner experimental design and a surface response design to determine the influence of experimental parameters and to optimize the final product. Starch-based microparticle formulations from the experimental plans were compared and characterized through particle size analysis, scanning electron microscopy, elemental analysis and, for the most promising formulations, by in vitro labeling stability studies and determination of free polyamine content or in vivo imaging studies. The mechanism of starch-based microparticle degradation was identified by means of size measurements. The results of the Rechtschaffner design showed the positive qualitative effect of the temperature and the duration of coupling reaction whereas surface response analysis clearly showed that, by increasing the oxidization level and starch concentration, the nitrogen content in the final product is increased. In vitro and in vivo characterization led to identification of the best formulation. With a size around 30 µm, high radiochemical purity (over 95%) and a high signal-to-noise ratio (over 600), the new starch-based microparticulate system could be prepared as ready-to-use kits and sterilized without modification of its characteristics, and thus meet the requirement for in vivo diagnostic and therapeutic applications.


Assuntos
Microesferas , Medicina Nuclear/métodos , Amido/uso terapêutico , Análise de Variância , Animais , Cadaverina/metabolismo , Cromatografia Líquida de Alta Pressão , Masculino , Oxirredução , Tamanho da Partícula , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Coloração e Rotulagem , Amido/química , Amido/ultraestrutura , Esterilização , Estresse Mecânico , Propriedades de Superfície
3.
Med Phys ; 37(2): 877-84, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20229897

RESUMO

PURPOSE: Susceptibility effects are a very efficient source of contrast in magnetic resonance imaging. However, detection is hampered by the fact the induced contrast is negative. In this work, the SIgnal Response MApping (SIRMA) to dephaser method is proposed to map susceptibility gradient to improve visualization. METHODS: In conventional gradient echo acquisitions, the echo formation of susceptibility affected spins is shifted in k-space, the shift being proportional to the susceptibility gradient. Susceptibility gradients map can be produced by measuring this induced shifts. The SIRMA method measures these shifts from a series of dephased images collected with additional incremental dephasers. These additional dephasers correspond either to a slice refocusing gradient offset or to a reconstruction window off-centering. The signal intensity profile as a function of the additional dephaser was determined on a pixel-by-pixel basis from the ensemble of dephased images. Susceptibility affected voxels presented a signal response profile maximum shifted compared to nonaffected voxels ones. Shift magnitude and sign were measured for each pixel to determine susceptibility gradients and produce a susceptibility gradient map. RESULTS: In vitro experiments demonstrated the ability of the method to map gradient inhomogeneities induced by a cylinder. Quantization accuracy was evaluated comparing SIRMA images and simulations performed on the well-characterized air filled cylinder model. Performances of the SIRMA method, evaluated in vitro on cylinders filled with various superparamagnetic iron oxide SPIO concentrations, showed limited influence of acquisition parameters. Robustness of the method was then assessed in vivo after an infusion of SPIO-loaded nanocapsules into the rat brain using a convection-enhanced drug delivery approach. The region of massive susceptibility gradient induced by the SPIO-loaded nanocapsules was clearly delineated on SIRMA maps and images were compared to T2* weighted images, Susceptibility Gradient Map (SGM), and histological Perl's staining slice. The potential for quantitative evaluation of SPIO distribution volume was demonstrated. CONCLUSIONS: The proposed method is a promising technique for a wide range of applications especially in molecular or cellular imaging with respect to its quantitative nature and its computational simplicity.


Assuntos
Algoritmos , Encéfalo/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Animais , Feminino , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Int J Pharm ; 344(1-2): 143-9, 2007 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-17646066

RESUMO

Paclitaxel-loaded lipid nanocapsules (PX-LNC) exhibit interesting in vitro characteristics with improved antitumoral activity compared with free PX formulation. Biodistribution studies were realized with the use of (14)C-trimyristin ((14)C-TM) or (14)C-phosphatidylcholine ((14)C-PC) whereas antitumoral activity of PX-LNC formulations was based on the animal survival in a chemically induced hepatocellular carcinoma (HCC) model in Wistar rats. Blood concentration-time profiles for both labeled (14)C-TM-LNC and (14)C-PC-LNC were similar; the t(1/2) and MRT values (over 2h and close to 3h, respectively, for both formulations) indicated the long circulating properties of the LNC carrier with a slow distribution and elimination phase. Survival curves of paclitaxel treated groups showed a statistical significant difference compared to the control survival curve (P=0.0036 and 0.0408). Animals treated with 4x 70 mg/m(2) of PX-LNC showed the most significant increase in mean survival times compared to the controls (IST(mean) 72%) and cases of long-term survivors were preferentially observed in the PX-LNC treated group (37.5%; 3/8). These results demonstrate the great interest to use LNC as drug delivery system for paclitaxel, permitting with an equivalent therapeutic efficiency to avoid the use of excipients such as polyoxyethylated castor oil for its formulation.


Assuntos
Antineoplásicos Fitogênicos/uso terapêutico , Nanocápsulas , Paclitaxel/uso terapêutico , Animais , Antineoplásicos Fitogênicos/administração & dosagem , Antineoplásicos Fitogênicos/farmacocinética , Área Sob a Curva , Disponibilidade Biológica , Carcinoma Hepatocelular/induzido quimicamente , Carcinoma Hepatocelular/tratamento farmacológico , Carcinoma Hepatocelular/mortalidade , Coloides , Portadores de Fármacos , Composição de Medicamentos , Meia-Vida , Lipídeos , Neoplasias Hepáticas Experimentais/induzido quimicamente , Neoplasias Hepáticas Experimentais/tratamento farmacológico , Neoplasias Hepáticas Experimentais/mortalidade , Paclitaxel/administração & dosagem , Paclitaxel/farmacocinética , Ratos , Ratos Wistar , Taxa de Sobrevida
5.
NMR Biomed ; 20(1): 21-7, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16998951

RESUMO

An in vitro MR-assay for superparamagnetic iron oxide (SPIO) particle cell labelling assessment via three-dimensional quantitative T(2) (*) MR microscopy was proposed. On high-resolution images, and due to the high susceptibility difference between the particles and the surrounding medium, SPIO internalized in cells induces signal loss which may be counted and measured on T(2) (*) maps. The increase in both labelled cell percentage and the average perturbation volume with an added amount of iron in the incubation medium proved that intracellular iron uptake is dependent upon the initial concentration of incubation iron. It also proved that the observed increases in total cellular iron uptake measured by inductively coupled plasma optical emission spectroscopy are due to both an increase in the iron mass per cell and also an increase in labelled cell concentration. MR results were compared with Prussian blue staining histology. The sensitivity of the MR methodology was then used to distinguish labelling differences for two different types of particle coating. The MRI-assay we proposed is a compulsory tool to optimize labelling efficiency in order to improve in vivo cell detection. Key parameters for detection, such as the percentage of cell labelling, the effect on the image for a given amount of internalized iron and labelling distribution among a cell population, are easily obtained. The comparison of different contrast agents for labelling one cell type, the assessment of one type of contrast agent for labelling different cell types and/or the evaluation of labelling strategies, are possible without having recourse to classical methods, and provide improved accuracy, since the principle is based on intracellular relaxivity.


Assuntos
Meios de Contraste/análise , Óxido Ferroso-Férrico/análise , Imageamento Tridimensional , Leucócitos Mononucleares/ultraestrutura , Imageamento por Ressonância Magnética/métodos , Animais , Corantes/análise , Relação Dose-Resposta a Droga , Endocitose , Ácido Etidrônico/análise , Ferrocianetos/análise , Leucócitos Mononucleares/química , Microscopia Eletrônica de Transmissão , Nanopartículas , Reação do Azul da Prússia , Ratos , Espectrofotometria Atômica , Coloração e Rotulagem
6.
MAGMA ; 18(6): 302-8, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16362430

RESUMO

OBJECTIVE: Volumetric evaluation of the myocardial viability post-infarction in rats using 3D in vivo MR imaging at 7 T using injection of an extracellular paramagnetic contrast agent and intravascular superparamagnetic iron oxide nanoparticles in the same imaging session. MATERIALS AND METHODS: Five hours after induction of permanent myocardial infarction in rats (n=6), 3D in vivo T1- and T2-weighted MR Imaging was performed prior to and after Gd-DOTA injection (0.2 mmol/kg) and prior to and after nanoparticle injection (5 mg Fe/kg) to assess infarct size and myocardial viability. RESULTS: 3D MR Imaging using a successive contrast agent injection showed a difference of infarct size after Gd-DOTA injection on T1-weighted images compared to the one measured on T2-weighted images after Gd-DOTA and nanoparticle injection. CONCLUSION: The use of 3D T1- and T2-weighted MR Imaging using a double contrast agents protocol made possible the accurate characterization of myocardial infarction volume and allowed the detection of myocardial viability post-infarction in rats.


Assuntos
Meios de Contraste , Compostos Heterocíclicos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/patologia , Compostos Organometálicos , Análise de Variância , Animais , Infarto do Miocárdio/terapia , Nanotecnologia , Tamanho da Partícula , Ratos
7.
Anat Embryol (Berl) ; 209(4): 263-7, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15864642

RESUMO

Glomerular differentiation starts as soon as embryonic stage 12 in mice and suggests that kidneys may be functional at this stage. Dynamic contrast-enhanced magnetic resonance microscopy, a noninvasive imaging technique, was used to assess renal function establishment in utero. Indeed, in adults (n = 3), an intravenous injection of gadolinium-DOTA induced in a first step a massive and rapid drop in kidney signal intensity followed, in a second step, by a drop in bladder signal intensity. The delay in signal changes between kidney and bladder reflected glomerular filtration. Pregnant mice underwent anatomical and dynamic contrast-enhanced magnetic resonance microscopy on postcoital days 12-13 (n = 2), 13-14 (n = 1), 14-15 (n = 3), 15-16 (n = 2), 16-17 (n = 3), 17-18 (n = 3), and 18-19 (n = 1). Kidneys and bladder were unambiguously depicted prior to contrast agent injection on stage 15-16 embryos. Contrast agent injection allowed kidney, detection as early as stage 12-13 but not bladder. Kinetics of signal changes demonstrated that glomerular filtration is established at embryonic stage 15-16 in mice. Thus, anatomical and dynamic contrast-enhanced magnetic resonance microscopy may be a powerful noninvasive method for in vivo prenatal developmental and functional studies.


Assuntos
Glomérulos Renais/embriologia , Glomérulos Renais/fisiologia , Imageamento por Ressonância Magnética/métodos , Animais , Diferenciação Celular , Meios de Contraste/administração & dosagem , Feminino , Compostos Heterocíclicos/administração & dosagem , Cinética , Camundongos , Microscopia/métodos , Compostos Organometálicos/administração & dosagem , Bexiga Urinária/embriologia
8.
MAGMA ; 17(3-6): 133-9, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15503254

RESUMO

Two different experimental rat brain tumours (F98 glioma and 9L glioma) were characterized using T1 and T2, apparent diffusion coefficient (ADC) and magnetization transfer ratio (MTR). Even though both tumours appeared homogenous at the early stage of growth, significant differences were measured for all parametric images between tumours and normal brain tissue. Irrespective of the sequence used, tumour lesion/normal parenchyma contrast for the non-infiltrative 9L was twice that of the infiltrative F98 glioma. The use of spin preparation via an inversion pulse in a fast spin echo sequence increases contrast by a factor of 20-30.


Assuntos
Neoplasias Encefálicas/diagnóstico , Modelos Animais de Doenças , Glioma/diagnóstico , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias Experimentais/diagnóstico , Animais , Feminino , Glioma/classificação , Ratos , Ratos Endogâmicos F344 , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença
9.
Invest Radiol ; 38(3): 141-6, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12595793

RESUMO

RATIONALE AND OBJECTIVES: The purpose of this study was to evaluate superparamagnetic iron oxide (SPIO) nanoparticles to discriminate infarcted from normal tissue after myocardial infarction using high field MR imaging (7 tesla). MATERIALS AND METHODS: Permanent myocardial infarction was induced in rats. SPIO nanoparticles (1 mg Fe/kg) were assessed with T1-weighted gradient echo sequence to visualize the myocardial infarction 48 hours after ligature (n = 6). Furthermore, MR Imaging was performed using a T2-weighted RARE sequence and nanoparticles were injected (5 or 10 mg Fe/kg) on 36 rats 5, 24 or 48 hours after infarction. RESULTS: No changes in contrast between normal and infarcted myocardium was observed after nanoparticle injection on T1-weighted images. However, nanoparticles induced a significant contrast increase between normal and infarcted myocardium on T2-weighted images whatever the delay between infarction and imaging (2.99 +/- 1.66 preinjection vs. 7.82 +/- 1.96 after SPIO injection at a dose of 5 mg Fe/kg 5 hours postinfarction, P = 0.0001). CONCLUSIONS: Nanoparticle injection made it possible to discriminate normal from infarcted myocardium on T2-weighted images. However, the high magnetic field prevented the visualization of the T1 effect of SPIO nanoparticles.


Assuntos
Ferro , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico , Óxidos , Análise de Variância , Animais , Feminino , Modelos Animais , Nanotecnologia , Tamanho da Partícula , Ratos , Ratos Wistar
10.
Anat Embryol (Berl) ; 206(1-2): 131-7, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12478374

RESUMO

Magnetic resonance microscopy, a non-invasive imaging technique was used for a longitudinal follow-up of mouse embryonic development in utero and for the assessment of embryonic kidney function using 50 nm magnetite dextran particles. Even though the morphologic proton images obtained were still far from classical histological slices quality, an in-plan resolution of 195 microm was achieved for a slice thickness of 800 microm. Mouse embryos sub-structures such as the fourth ventricle, the mesencephalic vesicle, the aorta or the liver can be revealed as early as E11/12. Heart, diaphragm, spinal cord, third, fourth and lateral ventricles were unambiguously seen at E13/14; whereas skeleton, tail, kidney and digit can only be seen from E15/16. Kidney and bladder were certainly identified from E16 on. MR microscopy offers a possibility for in utero phenotyping of mice and can therefore be a powerful tool for post-genomic applications.


Assuntos
Embrião de Mamíferos/anatomia & histologia , Desenvolvimento Embrionário e Fetal/fisiologia , Imageamento por Ressonância Magnética/métodos , Animais , Feminino , Idade Gestacional , Rim/anatomia & histologia , Masculino , Camundongos , Camundongos Endogâmicos , Gravidez , Bexiga Urinária/anatomia & histologia
11.
NMR Biomed ; 14(6): 360-6, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11599034

RESUMO

The aim of this work was to assess the therapeutic efficacy of an intratumoral bolus injection of 5-fluorouracil (FU) compared to that of drug loaded in biodegradable microspheres, for the treatment of brain tumour. Experiments were carried out using a fast-growing C6-glioma rat model. The therapeutic protocols were performed 12 days after the injection of glioma cells. At this stage, the tumours were installed and the mean volume was 13 +/- 2 microl as measured by proton magnetic resonance (MR) imaging. This technique was used for the follow-up of the tumour volume with respect to time and therapy. In terms of rat survival, both therapies induced a significant 50% increase in animal life span (p < 0.05) compared to animals receiving no drug or unloaded microspheres. Whilst no cure was observed, analysis of the MR images showed that the local and sustained delivery of FU slowed the tumour development in the vicinity of the microspheres by a factor of 3, compared with the bolus intratumoral injection.


Assuntos
Antimetabólitos Antineoplásicos/administração & dosagem , Neoplasias Encefálicas/tratamento farmacológico , Fluoruracila/administração & dosagem , Glioma/tratamento farmacológico , Imageamento por Ressonância Magnética , Microesferas , Animais , Antimetabólitos Antineoplásicos/uso terapêutico , Neoplasias Encefálicas/mortalidade , Neoplasias Encefálicas/patologia , Sistemas de Liberação de Medicamentos , Feminino , Fluoruracila/uso terapêutico , Glioma/mortalidade , Glioma/patologia , Injeções , Transplante de Neoplasias , Ratos , Ratos Sprague-Dawley , Taxa de Sobrevida , Fatores de Tempo , Células Tumorais Cultivadas
12.
Magn Reson Med ; 44(6): 893-8, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11108626

RESUMO

In vivo T(2), ADC, and MT properties of the GM and WM of the rat spinal cord were measured at 7T in the cervical region. The GM T(2), T(2GM) = 43.2 +/- 1.0 msec is significantly reduced compared to the WM T(2), T(2WM) = 57.0 +/- 1.6 msec. Diffusion is anisotropic for both GM and WM, with a larger ADC value along the cord axis (ADC(GM//) = 1.05 +/- 0.09 10(-9) m(2)sec(-1) and ADC(WM//) = 1.85 +/- 0.18 10(-9) m(2)sec(-1)) than perpendicular to this plane (ADC(GM)( perpendicular) approximately 0.50 * 10(-9) m(2)sec(-1) and ADC(WM)( perpendicular) approximately 0.18 * 10(-9) m(2)sec(-1)). The MT properties do not significantly differ between the WM and the GM, but allow one to distinguish the thin CSF layer from the WM. DWI with the sensitizing gradient perpendicular to the cord axis leads to the best contrast between GM and WM in the cervical region.


Assuntos
Imageamento por Ressonância Magnética/métodos , Medula Espinal/anatomia & histologia , Análise de Variância , Animais , Vértebras Cervicais/anatomia & histologia , Difusão , Feminino , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/estatística & dados numéricos , Ratos , Ratos Sprague-Dawley , Fatores de Tempo
13.
NMR Biomed ; 13(3): 116-23, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10861992

RESUMO

The potential of quantitative parameter images of transverse relaxation time T(2), apparent diffusion coefficient (ADC) and magnetization transfer ratio (MTR) to characterize experimental brain tumours was studied. Necrosis or haemorrhage can be detected using either MTR, ADC or T(2) (necrosis-MTR reduced by 35%, ADC and T(2) increased respectively by 170% and 100% compared with normal brain tissue; haemorrhage-MTR increased by 60%, ADC and T(2) decreased by 40% and 20%, respectively). Normal brain tissue can only be distinguished from tumour on T(2) and MTR parameter images. However, for small tumours (10 microl), the best contrast is observed with MTR, ca. 30%, whereas for T(2) the contrast is ca. 10%.


Assuntos
Neoplasias Encefálicas/diagnóstico , Imageamento por Ressonância Magnética/métodos , Animais , Interpretação Estatística de Dados , Difusão , Modelos Animais de Doenças , Feminino , Glioma/diagnóstico , Ratos , Ratos Sprague-Dawley , Fatores de Tempo , Água/metabolismo
14.
J Magn Reson Imaging ; 10(5): 899-902, 1999 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10548805

RESUMO

Phase contrast magnetic resonance imaging (PC MRI) is a promising method for assessing coronary flow. MR angiography images in the presence of coronary stents display artifacts because of the metal present in the stent. Using a flow phantom, the goal of this in vitro study was to assess quantitatively the effects of flow dephasing caused by magnetic susceptibility in velocity measurements in a region where the artifact is not visualized in a magnitude image. The results showed that for high velocities, significant errors in measurements exist around the stent, outside the susceptibility artifact visible on a magnitude image. J. Magn. Reson. Imaging 1999;10:899-902.


Assuntos
Vasos Coronários/patologia , Angiografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Stents , Artefatos , Velocidade do Fluxo Sanguíneo , Circulação Coronária , Humanos , Imagens de Fantasmas
15.
Arch Mal Coeur Vaiss ; 92(9): 1189-96, 1999 Sep.
Artigo em Francês | MEDLINE | ID: mdl-10533667

RESUMO

The object of this study was to analyse regional variations in end systolic left ventricular wall stress in normal subjects using three-dimensional magnetic resonance imaging (MRI) with excellent spatial resolution. Eight to 12 contiguous short axis sections of the left ventricle were acquired from the apex to the base in apnoea with a rapid echo-gradient sequence in 15 healthy volunteers. The end systolic wall stress was calculated by three methods: Grossman's formula (CR) using the wall thickness and radius of curvature, Janz's formula (CS) using the surfaces, and a three-dimensional approach (C3D) providing a precise calculation of the radius of curvature. The values of wall stress obtained by CS and CR were lower (p < 0.001) at the apex (3.2 and 3.3 10(3) newton/m2 respectively) than at the base (6.9 and 7.1 10(3) newton/m2). There was no difference between the base and apex with the C3D method (8.0 and 9.0 10(3) newton/m2 respectively, NS). The same results were observed at the inferior, lateral, anterior and septal segments with an increase at the base using the CS and CR formulae, the C3D remaining homogeneous in the left ventricle except for the interventricular septum. The lateral wall stress was significantly lower with respect to the interventricular septum in all sections from the apex to the base, irrespective of the method of calculation used. The differences in regional wall stress from the base to the apex reported in healthy subjects seem to be related to an underestimation of left ventricular wall thickness and an underestimation of the radius of curvature rather than to a physiological phenomenon.


Assuntos
Imageamento por Ressonância Magnética , Função Ventricular Esquerda/fisiologia , Função Ventricular , Adulto , Ecocardiografia Tridimensional , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Estresse Fisiológico
16.
Jpn J Pharmacol ; 80(4): 289-94, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10496328

RESUMO

The exact mechanisms of cerebral arterial hypoxia are not perfectly defined. Our purpose is to adapt and validate, with drugs well known in rats and rabbits, a closed cranial window technique in gerbils. The method was used with seventeen gerbils to measure diameter changes of the pial arterioles under normoxia (after the topical application of agonists and antagonists of ATP-sensitive and Ca2+-dependent potassium channels), as well as under hypoxia. In normoxia, aprikalim (10(-6) M), a direct activator of ATP-sensitive potassium channels, increases the diameter of pial arterioles by 10+/-2% (N = 17). This effect is inhibited by glibenclamide (10(-6) M), but not affected by iberiotoxin (10(-6) M), a specific inhibitor of Ca2+-dependent potassium channels. The adenosine-induced dilation by 19+/-5% (N = 17) is reduced by 59+/-16% with iberiotoxin, by 33+/-23% with glibenclamide and inhibited by theophylline (10(-5) M). In hypoxia (15% O2), pial arteriole diameters are increased by 24+/-5% (N = 17) and partially decreased by the application of glibenclamide and iberiotoxin to 59+/-11% and 54+/-5%, respectively. These data are similar to those obtained in other species and validate the closed cranial window technique on gerbils. They indicate that, as for rats and rabbits, both ATP-sensitive and Ca2+-dependent potassium channels are present in gerbil pial vessels and play a role in hypoxia.


Assuntos
Artérias/efeitos dos fármacos , Hipóxia Encefálica/patologia , Pia-Máter/irrigação sanguínea , Bloqueadores dos Canais de Potássio , Canais de Potássio/efeitos dos fármacos , Adenosina/farmacologia , Trifosfato de Adenosina/fisiologia , Animais , Cálcio/fisiologia , Interações Medicamentosas , Feminino , Gerbillinae , Microscopia de Vídeo , Pia-Máter/efeitos dos fármacos , Canais de Potássio/agonistas
17.
Am J Physiol ; 277(3): H901-10, 1999 09.
Artigo em Inglês | MEDLINE | ID: mdl-10484409

RESUMO

Left ventricular functional abnormalities are associated with regional increases of wall stress and modifications of wall curvature. This study describes the integration of the short-axis and long-axis wall curvatures for determining peak systolic wall stress. Quantification was realized with cine magnetic resonance imaging (MRI) from the location of the endocardial and epicardial borders of the left ventricle on pairs of consecutive short-axis sections. Fifteen normal volunteers were subjected to cine MRI, and different methods of calculating peak systolic wall stress were compared. A short-axis analysis showed a 55 +/- 13% increase of the circumferential mean of the peak systolic wall stress between apical and basal sections. Regarding the curvature, no significant increase of wall stress was observed except on the septal wall (31 +/- 18%). Short-axis studies proved to be insufficient for determining the regional variations of left ventricular wall stress and for providing normal reference values for the location of abnormal regions in patients.


Assuntos
Contração Miocárdica , Função Ventricular Esquerda/fisiologia , Função Ventricular , Adulto , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Masculino , Radiografia
18.
Magn Reson Imaging ; 17(8): 1111-20, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10499673

RESUMO

Respiratory gating with navigator echo is a recent technique to detect diaphragm position in 3D magnetic resonance (MR) coronary angiography. The purpose of our study was to image proximal coronary arteries and to detect significant stenoses in patients with coronary artery diseases and to compare with contrast enhanced angiography results. Twenty patients with coronary artery diseases who were referred for conventional angiography underwent magnetic resonance angiography (MRA). Three-dimensional gradient echo volumes were acquired using cardiac and respiratory gating and fat suppression. Using reformatted oblique planes and maximum intensity projection technique, visualization coronary segments and detection of significant coronary stenoses were made. Eighty-three coronary segments were analyzed. The sensitivity and specificity were 65% and 93%, respectively. The corresponding positive and negative predictive values were 69% and 91%. This study shows the ability to image correctly coronary arteries and to identify proximal stenoses, but image quality need to be improved for an efficiency detection of coronary artery stenoses in clinical practice.


Assuntos
Angiografia Coronária , Doença das Coronárias/diagnóstico , Vasos Coronários/patologia , Processamento de Imagem Assistida por Computador , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Respiração
19.
Am J Cardiol ; 84(1): 24-30, 1999 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-10404846

RESUMO

This study assesses infarct-related coronary artery blood flow velocity using phase-contrast magnetic resonance imaging (MRI) in patients with reperfused acute myocardial infarction (AMI) and compares these results with flow measurements obtained nonsimultaneously by intracoronary Doppler ultrasound. MRI examination was performed in 17 patients with AMI within 1 to 4 days (mean 2.5 days) after direct or rescue coronary angioplasty using a 0.014-in Doppler guidewire. MRI was performed on a 1.5-T clinical imager. The fast gradient echo segmented k-space phase-contrast pulse sequence was employed during breath-hold. The MRI and Doppler parameters of average peak velocity and maximum peak velocity were measured. Mean phase contrast MRI average peak velocity was 13.3+/-10.7 cm/s, and mean phase-contrast MRI maximum peak velocity was 27+/-16.6 cm/s. Mean Doppler average peak velocity was 17.1+/-5.1 cm/s, and mean Doppler maximum peak velocity was 35.5+/-10.1 cm/s. At the same anatomic levels, phase-contrast MRI average peak velocity correlated significantly to Doppler average peak velocity (r = 0.52; p<0.006) and Doppler maximum peak velocity (r = 0.42; p<0.03). Phase-contrast MRI velocity measurements were correlated with the same heterogeneity of Thrombolysis In Myocardial Infarction 3 flow velocity observed during Doppler examination. Thus, by comparing phase-contrast MRI with invasive intracoronary Doppler flow measurements, the measured MRI values showed significant correlation with Doppler data. Phase-contrast MRI has the potential to noninvasively quantify coronary flow velocity and to evaluate quality of reperfusion in patients with AMI after reperfused therapy.


Assuntos
Angioplastia Coronária com Balão , Circulação Coronária/fisiologia , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/terapia , Velocidade do Fluxo Sanguíneo/fisiologia , Angiografia Coronária , Vasos Coronários/patologia , Humanos , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Reperfusão Miocárdica , Estudos Prospectivos , Ultrassonografia Doppler , Ultrassonografia de Intervenção
20.
Eur J Nucl Med ; 26(6): 640-6, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10369950

RESUMO

The aim of this study was to correlate lung thallium-201 uptake on exercise with 201Tl single-photon emission tomography (SPET) myocardial perfusion imaging, rest and exercise equilibrium radionuclide angiographic and coronary angiographic findings in patients with coronary artery disease (CAD) using a simple, reproducible lung/heart (L/H) ratio that would be easy to use in clinical practice. L/H ratio was defined on the anterior planar image obtained during exercise 201Tl SPET acquisition as the mean counts per pixel in an entire right lung field region of interest divided by the mean counts per pixel in the hottest myocardial wall region of interest. We studied 103 patients. Fifty-nine patients (group I) with <5% likelihood of CAD were used as a reference group. In 44 CAD patients (group II), L/H ratio was compared with 201Tl SPET, radionuclide angiographic and coronary angiographic variables. The group I L/H ratio of 0.35+/-0.05 (mean +/-1 SD) was significantly lower (P<0.001) than the group II L/H ratio of 0. 45+/-0.10. An L/H ratio >0.45 (mean + 2 SD in group I) was considered abnormal. In group II, L/H ratio showed a significant correlation with stress and rest 201Tl perfusion defect size (r = 0. 39 and r = 0.42, P<0.01, respectively), but not with extent of ischaemic myocardium. The mean L/H ratio was 0.41+/-0.10 in patients with one-vessel disease (n = 15), 0.46+/-0.08 in those with two-vessel disease (n = 17) and 0.47+/-0.12 in those with three-vessel disease (n = 12), but no significant difference was found between the three subgroups. L/H ratio showed a significant inverse relation with rest and exercise left ventricular ejection fraction (r = -0.37 and r = -0.50, P<0.05 and P<0.001, respectively). Using stepwise multiple regression analysis, exercise left ventricular ejection fraction and previous history of hypertension were the sole two variables independently predictive of the L/H ratio. In conclusion, although lung thallium uptake is usually found to correlate with extent and severity of CAD, increased L/H ratio should primarily be considered as a marker of exercise-induced left ventricular systolic and perhaps diastolic dysfunction, probably independent of the underlying cardiac disease.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único , Disfunção Ventricular Esquerda/diagnóstico por imagem , Estudos de Casos e Controles , Angiografia Coronária , Exercício Físico/fisiologia , Feminino , Imagem do Acúmulo Cardíaco de Comporta , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Regressão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...