Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
MAGMA ; 37(2): 169-183, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38197908

RESUMO

OBJECTIVE: To assess the possible influence of third-order shim coils on the behavior of the gradient field and in gradient-magnet interactions at 7 T and above. MATERIALS AND METHODS: Gradient impulse response function measurements were performed at 5 sites spanning field strengths from 7 to 11.7 T, all of them sharing the same exact whole-body gradient coil design. Mechanical fixation and boundary conditions of the gradient coil were altered in several ways at one site to study the impact of mechanical coupling with the magnet on the field perturbations. Vibrations, power deposition in the He bath, and field dynamics were characterized at 11.7 T with the third-order shim coils connected and disconnected inside the Faraday cage. RESULTS: For the same whole-body gradient coil design, all measurements differed greatly based on the third-order shim coil configuration (connected or not). Vibrations and gradient transfer function peaks could be affected by a factor of 2 or more, depending on the resonances. Disconnecting the third-order shim coils at 11.7 T also suppressed almost completely power deposition peaks at some frequencies. DISCUSSION: Third-order shim coil configurations can have major impact in gradient-magnet interactions with consequences on potential hardware damage, magnet heating, and image quality going beyond EPI acquisitions.


Assuntos
Imageamento por Ressonância Magnética , Imãs , Imageamento por Ressonância Magnética/métodos
2.
Magn Reson Med ; 91(4): 1434-1448, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38156952

RESUMO

PURPOSE: Static and dynamic B 0 $$ {\mathrm{B}}_0 $$ field imperfections are detrimental to functional MRI (fMRI) applications, especially at ultra-high magnetic fields (UHF). In this work, a field camera is used to assess the benefits of retrospectively correcting B 0 $$ {\mathrm{B}}_0 $$ field perturbations on Blood Oxygen Level Dependent (BOLD) sensitivity in non-Cartesian three-dimensional (3D)-SPARKLING fMRI acquisitions. METHODS: fMRI data were acquired at 1 mm 3 $$ {}^3 $$ and for a 2.4s-TR while concurrently monitoring in real-time field perturbations using a Skope Clip-on field camera in a novel experimental setting involving a shorter TR than the required minimal TR of the field probes. Measurements of the dynamic field deviations were used along with a static Δ B 0 $$ \Delta {\mathrm{B}}_0 $$ map to retrospectively correct static and dynamic field imperfections, respectively. In order to evaluate the impact of such a correction on fMRI volumes, a comparative study was conducted on healthy volunteers. RESULTS: Correction of B 0 $$ {\mathrm{B}}_0 $$ deviations improved image quality and yielded between 20% and 30% increase in median temporal signal-to-noise ratio (tSNR).Using fMRI data collected during a retinotopic mapping experiment, we demonstrated a significant increase in sensitivity to the BOLD contrast and improved accuracy of the BOLD phase maps: 44% (resp., 159%) more activated voxels were retrieved when using a significance control level based on a p-value of 0.001 without correcting for multiple comparisons (resp., 0.05 with a false discovery rate correction). CONCLUSION: 3D-SPARKLING fMRI hugely benefits from static and dynamic B 0 $$ {\mathrm{B}}_0 $$ imperfections correction. However, the proposed experimental protocol is flexible enough to be deployed on a large spectrum of encoding schemes, including arbitrary non-Cartesian readouts.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico/métodos , Estudos Retrospectivos , Razão Sinal-Ruído
3.
Magn Reson Med ; 90(2): 699-707, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37036024

RESUMO

PURPOSE: Assess short-term and long-term effects of chronic exposure to an ultrahigh static magnetic (B0 ) field on mice inner ear in the context of MR safety of human scanning at 11.7 T. METHODS: Mice were chronically exposed to a B0 field of 11.7 T or 17.2 T during ten 2-h exposure sessions evenly distributed over a period of 5 weeks, resulting in a total of 20 h of exposure per mouse. During exposure sessions, mice were anesthetized and positioned either parallel or antiparallel to B0 . Before, during, and 2 weeks after the magnetic-field exposure period, mice performed behavioral tests (balance beam, rotarod, and swim tests) to evaluate their short-term and long-term motor coordination and balance. An auditory brainstem response (ABR) test was finally performed to assess the functional integrity of mice cochlea, 2 weeks after the last exposure. RESULTS: After awaking from anesthesia following B0 exposures at 11.7 Tor 17.2 T, mice displayed a transient (<5 min) rotating behavior. The behavioral tests did not show any difference between the exposed and the control mice at any time point. Determination of ABR thresholds did not reveal an impairment of cochlea hair cells resulting from chronic B0 exposure. CONCLUSION: Despite the transient disturbance of mice vestibular system observed immediately after B0 exposure, no short-term nor long-term alteration was detected with behavioral and ABR tests.


Assuntos
Orelha Interna , Potenciais Evocados Auditivos do Tronco Encefálico , Camundongos , Humanos , Animais , Limiar Auditivo/fisiologia , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Orelha Interna/diagnóstico por imagem
4.
Magn Reson Med ; 88(5): 2131-2138, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35849739

RESUMO

PURPOSE: The SNR at the center of a spherical phantom of known electrical properties was measured in quasi-identical experimental conditions as a function of magnetic field strength between 3 T and 11.7 T. METHODS: The SNR was measured at the center of a spherical water saline phantom with a gradient-recalled echo sequence. Measurements were performed at NeuroSpin at 3, 7, and 11.7 T. The phantom was then shipped to Maastricht University and then to the University of Minnesota for additional data points at 7, 9.4, and 10.5 T. Experiments were carried out with the exact same type of birdcage volume coil (except at 3 T, where a similar coil was used) to attempt at isolating the evolution of SNR with field strength alone. Phantom electrical properties were characterized over the corresponding frequency range. RESULTS: Electrical properties were found to barely vary over the frequency range. Removing the influence of the flip-angle excitation inhomogeneity was crucial, as expected. After such correction, measurements revealed a gain of SNR growing as B0 1.94 ± 0.16 compared with B0 2.13 according to ultimate intrinsic SNR theory. CONCLUSIONS: By using quasi-identical experimental setups (RF volume coil, phantom, electrical properties, and protocol), this work reports experimental data between 3 T and 11.7 T, enabling the comparison with SNR theories in which conductivity and permittivity can be assumed to be constant with respect to field strength. According to ultimate SNR theory, these results can be reasonably extrapolated to the performance of receive arrays with greater than about 32 elements for central SNR in the same spherical phantom.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Humanos , Campos Magnéticos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Razão Sinal-Ruído
5.
Magn Reson Med ; 87(6): 2839-2850, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35122302

RESUMO

PURPOSE: In parallel transmission (pTX), subject-tailored RF pulses allow achieving excellent flip angle (FA) accuracy but often require computationally extensive online optimizations, precise characterization of the static field ( ΔB0 ), and the transmit RF field ( B1+ ) distributions. This costs time and requires expertise from the MR user. Universal pulses (UPs) have been proposed to reduce this burden, yet, with a penalty in FA accuracy. This study introduces the concept of standardized universal pulses (SUPs), where pulses are designed offline and adjusted to the subject through a fast online calibration scan. METHODS: A SUP is designed offline using a so-called standardized database, wherein each B1+ map has been normalized to a reference transmit RF field distribution. When scanning a new subject, a 3-slice B1+ acquisition (scan time <10  s) is performed and used to adjust the SUP to the subject through a linear transform. SUP performance was assessed at 7T with simulations by computing the FA-normalized root mean square error (FA-NRMSE) and the FA pattern stability as measured by the average and coefficient of variation of the FA across 15 control subjects, along with in vivo experiments using an MP2RAGE sequence implementing the SUP variant for the FLASH readout. RESULTS: Adjusted SUP improved the FA-NRMSE (8.8 % for UP vs. 7.1 % for adjusted SUP). Experimentally in vivo, this translated in an improved signal homogeneity and more accurate T1 quantification using MP2RAGE. CONCLUSION: The proposed SUP approach improves excitation accuracy (FA-NRMSE) while preserving the same offline pulse design principle as offered by UPs.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Encéfalo , Calibragem , Bases de Dados Factuais , Humanos , Imagens de Fantasmas , Ondas de Rádio
6.
Magn Reson Med ; 87(3): 1390-1400, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34687068

RESUMO

PURPOSE: An MR thermometry (MRT) method with motion and field fluctuation compensation is proposed to measure non-invasively sub-degree brain temperature variations occurring through radiofrequency (RF) power deposition during MR exams. METHODS: MRT at 7T with a multi-slice echo planar imaging (EPI) sequence and concurrent field monitoring was first tested in vitro to assess accuracy in the presence of external field perturbations, an optical probe being used for ground truth. In vivo, this strategy was complemented by a motion compensation scheme based on a dictionary pre-scan, as reported in some previous work, and was adapted to the human brain. Precision reached with this scheme was assessed on eight volunteers with a 5 minute-long low specific absorption rate (SAR) scan. Finally, temperature rise in the brain was measured twice on the same volunteers and with the same strategy, this time by employing a 20-minutes scan at the maximum SAR delivered with a commercial volume head coil. RESULTS: In vitro, the root mean square (RMS) error between optical probe and MRT measurements was 0.02°C with field sensor correction. In vivo, the low SAR scan returned a precision in temperature change measurement with field monitoring and motion compensation of 0.05°C. The 20-minutes maximum SAR scan returned a temperature rise throughout the inner-brain in the range of 0-0.2°C. Brain periphery remained too sensitive with respect to motion to lead to equally conclusive results. CONCLUSION: Sub-degree temperature rise in the inner human brain was characterized experimentally throughout RF exposure. Potential applications include improvement of human thermal models and revision of safety margins.


Assuntos
Termometria , Encéfalo/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Temperatura
7.
PLoS One ; 16(11): e0259592, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34748584

RESUMO

For functional MRI with a multi-channel receiver RF coil, images are often reconstructed channel by channel, resulting into multiple images per time frame. The final image to analyze usually is the result of the covariance Sum-of-Squares (covSoS) combination across these channels. Although this reconstruction is quasi-optimal in SNR, it is not necessarily the case in terms of temporal SNR (tSNR) of the time series, which is yet a more relevant metric for fMRI data quality. In this work, we investigated tSNR optimality through voxel-wise RF coil combination and its effects on BOLD sensitivity. An analytical solution for an optimal RF coil combination is described, which is somewhat tied to the extended Krueger-Glover model involving both thermal and physiological noise covariance matrices. Compared experimentally to covSOS on four volunteers at 7T, the method yielded great improvement of tSNR but, surprisingly, did not result into higher BOLD sensitivity. Solutions to improve the method such as for example the t-score for the mean recently proposed are also explored, but result into similar observations once the statistics are corrected properly. Overall, the work shows that data-driven RF coil combinations based on tSNR considerations alone should be avoided unless additional and unbiased assumptions can be made.


Assuntos
Imageamento por Ressonância Magnética , Humanos , Ondas de Rádio
8.
Magn Reson Med ; 85(3): 1282-1293, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32936510

RESUMO

PURPOSE: A MR thermometry (MRT) method with field monitoring is proposed to improve the measurement of small temperature variations induced in brain MRI exams. METHODS: MR thermometry experiments were performed at 7 Tesla with concurrent field monitoring and RF heating. Images were reconstructed with nominal k-space trajectories and with first-order spherical harmonics correction. Experiments were performed in vitro with deliberate field disturbances and on an anesthetized macaque in 2 different specific absorption rate regimes, that is, at 50% and 100% of the maximal specific absorption rate level allowed in the International Electrotechnical Commission normal mode of operation. Repeatability was assessed by running a second separate session on the same animal. RESULTS: Inclusion of magnetic field fluctuations in the reconstruction improved temperature measurement accuracy in vitro down to 0.02°C. Measurement precision in vivo was on the order of 0.15°C in areas little affected by motion. In the same region, temperature increase reached 0.5 to 0.8°C after 20 min of heating at 100% specific absorption rates and followed a rough factor of 2 with the 50% specific absorption rate scans. A horizontal temperature plateau, as predicted by Pennes bioheat model with thermal constants from the literature and constant blood temperature assumption, was not observed. CONCLUSION: Inclusion of field fluctuations in image reconstruction was beneficial for the measurement of small temperature rises encountered in standard brain exams. More work is needed to correct for motion-induced field disturbances to extract reliable temperature maps.


Assuntos
Calefação , Termometria , Animais , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Temperatura
9.
PLoS One ; 14(11): e0225286, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31751410

RESUMO

The simultaneous multi-slice EPI (SMS-EPI, a.k.a. MB-EPI) sequence has met immense popularity recently in functional neuroimaging. A still less common alternative is the use of 3D-EPI, which offers similar acceleration capabilities. The aim of this work was to compare the SMS-EPI and the 3D-EPI sequences in terms of sampling strategies for the detection of task-evoked activations at 7T using detection theory. To this end, the spatial and temporal resolutions of the sequences were matched (1.6 mm isotropic resolution, TR = 1200 ms) and their excitation profiles were homogenized by means of calibration-free parallel-transmission (Universal Pulses). We used a fast-event "localizer" paradigm of 5:20 min in order to probe sensorimotor functions (visual, auditory and motor tasks) as well as higher level functions (language comprehension, mental calculation), where results from a previous large-scale study at 3T (N = 81) served as ground-truth reference for the brain areas implicated in each cognitive function. In the current study, ten subjects were scanned while their activation maps were generated for each cognitive function with the GLM analysis. The SMS-EPI and 3D-EPI sequences were compared in terms of raw tSNR, t-score testing for the mean signal, activation strength and accuracy of the robust sensorimotor functions. To this end, the sensitivity and specificity of these contrasts were computed by comparing their activation maps to the reference brain areas obtained in the 3T study. Estimated flip angle distributions in the brain reported a normalized root mean square deviation from the target value below 10% for both sequences. The analysis of the t-score testing for the mean signal revealed temporal noise correlations, suggesting the use of this metric instead of the traditional tSNR for testing fMRI sequences. The SMS-EPI and 3D-EPI thereby yielded similar performance from a detection theory perspective.


Assuntos
Encéfalo/fisiologia , Imagem Ecoplanar , Imageamento por Ressonância Magnética , Adulto , Mapeamento Encefálico/métodos , Imagem Ecoplanar/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Masculino , Curva ROC , Sensibilidade e Especificidade , Razão Sinal-Ruído , Adulto Jovem
10.
J Magn Reson Imaging ; 49(3): 768-776, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30194746

RESUMO

BACKGROUND: A limited number of studies have used the intravoxel incoherent motion (IVIM) approach on bone marrow. In none of the previous studies were the effects of fat suppression on the IVIM parameters investigated. PURPOSE: To measure the water diffusion coefficient and the perfusion fraction in vertebral bone marrow using IVIM with multishot, readout-segmented (RESOLVE) echo-planar imaging and to assess the effects of different fat suppression techniques on the measurement of the IVIM parameters. STUDY TYPE: Prospective. POPULATION/SUBJECTS: Six healthy volunteers (24.2 ± 4.3 years). FIELD STRENGTH/SEQUENCE: 1.5T, RESOLVE. ASSESSMENT: Four experiments were performed: 1) RESOLVE imaging without fat suppression, 2) with fat saturation (FS), 3) with spectral attenuated inversion recovery (SPAIR), and 4) with short-tau inversion recovery (STIR). The water diffusion coefficient D, pseudo-diffusion coefficient D*, and the perfusion fraction f were assessed in the vertebral bodies of the lumbar vertebrae. STATISTICAL TESTS: One-way repeated-measures analysis of variance (ANOVA) followed by Bonferroni's multiple comparison test. RESULTS: The RESOLVE IVIM protocol allowed for measurement of D, D*, and f in all volunteers. The signal of lipid protons affected the quantification of the IVIM diffusion coefficient: D = 0.24 ± 0.10 (×10-3 mm2 /s), no FS; D = 0.43 ± 0.07 (×10-3 mm2 /s), FS; D = 0.42 ± 0.07 (×10-3 mm2 /s), SPAIR; D = 0.35 ± 0.10 (×10-3 mm2 /s), STIR; and IVIM perfusion fraction f = 7.5 ± 1.9% no FS, f = 14.5 ± 5.4%, FS; f = 12.5 ± 2.6%, SPAIR; f = 18.1 ± 6.1%, STIR. No significant effect (P = 0.36) was found on the quantification of D*. DATA CONCLUSION: An IVIM-MRI protocol using the RESOLVE sequence was implemented for measurements of vertebral bone marrow diffusion and the perfusion. The comparison between the protocols with and without fat suppression indicates that the lipid signal results in an underestimation of both D and f. LEVEL OF EVIDENCE: Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2019;49:768-776.


Assuntos
Medula Óssea/diagnóstico por imagem , Imagem Ecoplanar , Coluna Vertebral/diagnóstico por imagem , Tecido Adiposo/diagnóstico por imagem , Adulto , Algoritmos , Imagem de Difusão por Ressonância Magnética , Feminino , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Movimento (Física) , Perfusão , Estudos Prospectivos , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Adulto Jovem
11.
Magn Reson Imaging ; 39: 157-161, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28263827

RESUMO

PURPOSE: Bone marrow is found either as red bone marrow, which mainly contains haematopoietic cells, or yellow bone marrow, which mainly contains adipocytes. In adults, red bone marrow is principally located in the axial skeleton. A recent study has introduced a method to simultaneously estimate the fat fraction (FF), the T1 and T2* relaxation times of water (T1w, T2*w) and fat (T1f and T2*f) in the vertebral bone marrow. The aim of the current study was to measure FF, T1w, T1f, T2*w and T2*f in five sites of bone marrow, and to assess the presence of regional variations. METHODS: MRI experiments were performed at 1.5T on five healthy volunteers (31.6±15.6years) using a prototype chemical-shift-encoded 3D multi-gradient-echo sequence (VIBE) acquired with two flip angles. Acquisitions were performed in the shoulders, lumbar spine and pelvis, with acquisition times of <25seconds per sequence. Signal intensities of magnitude images of the individual echoes were used to fit the signal and compute FF, T1w, T1f, T2*w and T2*f in the humerus, sternum, vertebra, ilium and femur. RESULTS: Regional variations of fat fraction and relaxation times were observed in these sites, with higher fat fraction and longer T1w in the epiphyses of long bones. A high correlation between FF and T1w was measured in these bones (R=0.84 in the humerus and R=0.84 in the femur). In most sites, there was a significant difference between water and fat relaxation times, attesting the relevance of measuring these parameters separately. CONCLUSION: The method proposed in the current study allowed for measurements of FF, T1w, T1f, T2*w and T2*f in five sites of bone marrow. Regional variations of these parameters were observed and a strong negative correlation between the T1 of water and the fat fraction in bones with high fat fractions was found.


Assuntos
Medula Óssea/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adipócitos/patologia , Adulto , Feminino , Voluntários Saudáveis , Humanos , Úmero , Masculino , Pessoa de Meia-Idade , Pelve/diagnóstico por imagem , Água/química , Adulto Jovem
12.
J Magn Reson Imaging ; 44(3): 549-55, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-26918280

RESUMO

PURPOSE: To assess the feasibility of measuring the fat fraction, T1 and T2 * relaxation times of water and fat signals in vertebral bone marrow using breath-hold magnetic resonance imaging (MRI) gradient echo images of the spine. MATERIALS AND METHODS: MRI experiments were performed at 1.5T on eight healthy volunteers (35.1 ± 15.7 years, five men and three women) using two sagittal four-echo 3D gradient echo volumetric interpolated breath-hold examination (VIBE Dixon) sequences acquired at two different flip angles (5° and 15°). The water/fat decomposition was performed in the vertebral bodies of L1 to L5 by fitting the signal to a function that depends on the echo time and the flip angle to calculate the fat fraction (FF) and T1 and T2 * relaxation times of water and fat signals. Repeatability was assessed by scanning one volunteer six times. RESULTS: The mean fat fraction over L1 to L5 was 33 ± 8%. The mean T1 and T2 * of water and fat signals were respectively T1w = 701 ± 151 msec, T2 *w = 13.7 ± 2.9 msec, T1f = 334 ± 113 msec, and T2 *f = 11.4 ± 2.7 msec. When considering each vertebra separately, the fat fraction increased from L1 to L5 and the T1w decreased from L1 to L5. The mean coefficients of variation obtained from the repeatability study were 8% (FF), 11% (T1w ), 17% (T1f ), 8% (T2 *w ), and 27% (T2 *f ). CONCLUSION: The method introduced in the current study allows for the measurement of the fat fraction and water and fat relaxation times, with a total acquisition time of less than 40 seconds. J. Magn. Reson. Imaging 2016;44:549-555.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Água Corporal/diagnóstico por imagem , Medula Óssea/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tecido Adiposo/fisiologia , Adiposidade/fisiologia , Adulto , Água Corporal/fisiologia , Medula Óssea/fisiologia , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Vértebras Lombares/fisiologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Mecânica Respiratória , Sensibilidade e Especificidade , Adulto Jovem