Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Tomography ; 9(5): 1949-1964, 2023 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-37888744

RESUMO

Deep learning (DL) reconstruction techniques to improve MR image quality are becoming commercially available with the hope that they will be applicable to multiple imaging application sites and acquisition protocols. However, before clinical implementation, these methods must be validated for specific use cases. In this work, the quality of standard-of-care (SOC) T2w and a high-spatial-resolution (HR) imaging of the breast were assessed both with and without prototype DL reconstruction. Studies were performed using data collected from phantoms, 20 retrospectively collected SOC patient exams, and 56 prospectively acquired SOC and HR patient exams. Image quality was quantitatively assessed via signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and edge sharpness. Qualitatively, all in vivo images were scored by either two or four radiologist readers using 5-point Likert scales in the following categories: artifacts, perceived sharpness, perceived SNR, and overall quality. Differences in reader scores were tested for significance. Reader preference and perception of signal intensity changes were also assessed. Application of the DL resulted in higher average SNR (1.2-2.8 times), CNR (1.0-1.8 times), and image sharpness (1.2-1.7 times). Qualitatively, the SOC acquisition with DL resulted in significantly improved image quality scores in all categories compared to non-DL images. HR acquisition with DL significantly increased SNR, sharpness, and overall quality compared to both the non-DL SOC and the non-DL HR images. The acquisition time for the HR data only required a 20% increase compared to the SOC acquisition and readers typically preferred DL images over non-DL counterparts. Overall, the DL reconstruction demonstrated improved T2w image quality in clinical breast MRI.


Assuntos
Aprendizado Profundo , Humanos , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Mama/diagnóstico por imagem , Razão Sinal-Ruído
2.
Front Physiol ; 14: 1167148, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37228813

RESUMO

BOLD sensitivity to baseline perfusion and blood volume is a well-acknowledged fMRI confound. Vascular correction techniques based on cerebrovascular reactivity (CVR) might reduce variance due to baseline cerebral blood volume, however this is predicated on an invariant linear relationship between CVR and BOLD signal magnitude. Cognitive paradigms have relatively low signal, high variance and involve spatially heterogenous cortical regions; it is therefore unclear whether the BOLD response magnitude to complex paradigms can be predicted by CVR. The feasibility of predicting BOLD signal magnitude from CVR was explored in the present work across two experiments using different CVR approaches. The first utilized a large database containing breath-hold BOLD responses and 3 different cognitive tasks. The second experiment, in an independent sample, calculated CVR using the delivery of a fixed concentration of carbon dioxide and a different cognitive task. An atlas-based regression approach was implemented for both experiments to evaluate the shared variance between task-invoked BOLD responses and CVR across the cerebral cortex. Both experiments found significant relationships between CVR and task-based BOLD magnitude, with activation in the right cuneus (R 2 = 0.64) and paracentral gyrus (R 2 = 0.71), and the left pars opercularis (R 2 = 0.67), superior frontal gyrus (R 2 = 0.62) and inferior parietal cortex (R 2 = 0.63) strongly predicted by CVR. The parietal regions bilaterally were highly consistent, with linear regressions significant in these regions for all four tasks. Group analyses showed that CVR correction increased BOLD sensitivity. Overall, this work suggests that BOLD signal response magnitudes to cognitive tasks are predicted by CVR across different regions of the cerebral cortex, providing support for the use of correction based on baseline vascular physiology.

3.
Eur Radiol ; 32(9): 6167-6177, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35322280

RESUMO

OBJECTIVES: To compare interobserver agreement and image quality of 3D T2-weighted fast spin echo (T2w-FSE) L-spine MRI images processed with a deep learning reconstruction (DLRecon) against standard-of-care (SOC) reconstruction, as well as against 2D T2w-FSE images. The hypothesis was that DLRecon 3D T2w-FSE would afford improved image quality and similar interobserver agreement compared to both SOC 3D and 2D T2w-FSE. METHODS: Under IRB approval, patients who underwent routine 3-T lumbar spine (L-spine) MRI from August 17 to September 17, 2020, with both isotropic 3D and 2D T2w-FSE sequences, were retrospectively included. A DLRecon algorithm, with denoising and sharpening properties was applied to SOC 3D k-space to generate 3D DLRecon images. Four musculoskeletal radiologists blinded to reconstruction status evaluated randomized images for motion artifact, image quality, central/foraminal stenosis, disc degeneration, annular fissure, disc herniation, and presence of facet joint cysts. Inter-rater agreement for each graded variable was evaluated using Conger's kappa (κ). RESULTS: Thirty-five patients (mean age 58 ± 19, 26 female) were evaluated. 3D DLRecon demonstrated statistically significant higher median image quality score (2.0/2) when compared to SOC 3D (1.0/2, p < 0.001), 2D axial (1.0/2, p < 0.001), and 2D sagittal sequences (1.0/2, p value < 0.001). κ ranges (and 95% CI) for foraminal stenosis were 0.55-0.76 (0.32-0.86) for 3D DLRecon, 0.56-0.73 (0.35-0.84) for SOC 3D, and 0.58-0.71 (0.33-0.84) for 2D. Mean κ (and 95% CI) for central stenosis at L4-5 were 0.98 (0.96-0.99), 0.97 (0.95-0.99), and 0.98 (0.96-0.99) for 3D DLRecon, 3D SOC and 2D, respectively. CONCLUSIONS: DLRecon 3D T2w-FSE L-spine MRI demonstrated higher image quality and similar interobserver agreement for graded variables of interest when compared to 3D SOC and 2D imaging. KEY POINTS: • 3D DLRecon T2w-FSE isotropic lumbar spine MRI provides improved image quality when compared to 2D MRI, with similar interobserver agreement for clinical evaluation of pathology. • 3D DLRecon images demonstrated better image quality score (2.0/2) when compared to standard-of-care (SOC) 3D (1.0/2), p value < 0.001; 2D axial (1.0/2), p value < 0.001; and 2D sagittal sequences (1.0/2), p value < 0.001. • Interobserver agreement for major variables of interest was similar among all sequences and reconstruction types. For foraminal stenosis, κ ranged from 0.55 to 0.76 (95% CI 0.32-0.86) for 3D DLRecon, 0.56-0.73 (95% CI 0.35-0.84) for standard-of-care (SOC) 3D, and 0.58-0.71 (95% CI 0.33-0.84) for 2D.


Assuntos
Aprendizado Profundo , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Adulto , Idoso , Constrição Patológica , Feminino , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
4.
Magn Reson Imaging ; 85: 186-192, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34715288

RESUMO

OBJECTIVE: To assess a new deep learning-based MR reconstruction method, "DLRecon," for clinical evaluation of peripheral nerves. METHODS: Sixty peripheral nerves were prospectively evaluated in 29 patients (mean age: 49 ± 16 years, 17 female) undergoing standard-of-care (SOC) MR neurography for clinically suspected neuropathy. SOC-MRIs and DLRecon-MRIs were obtained through conventional and DLRecon reconstruction methods, respectively. Two radiologists randomly evaluated blinded images for outer epineurium conspicuity, fascicular architecture visualization, pulsation artifact, ghosting artifact, and bulk motion. RESULTS: DLRecon-MRIs were likely to score better than SOC-MRIs for outer epineurium conspicuity (OR = 1.9, p = 0.007) and visualization of fascicular architecture (OR = 1.8, p < 0.001) and were likely to score worse for ghosting (OR = 2.8, p = 0.004) and pulsation artifacts (OR = 1.6, p = 0.004). There was substantial to almost-perfect inter-reconstruction method agreement (AC = 0.73-1.00) and fair to almost-perfect interrater agreement (AC = 0.34-0.86) for all features evaluated. DLRecon-MRI had improved interrater agreement for outer epineurium conspicuity (AC = 0.71, substantial agreement) compared to SOC-MRIs (AC = 0.34, fair agreement). In >80% of images, the radiologist correctly identified an image as SOC- or DLRecon-MRI. DISCUSSION: Outer epineurium and fascicular architecture conspicuity, two key morphological features critical to evaluating a nerve injury, were improved in DLRecon-MRIs compared to SOC-MRIs. Although pulsation and ghosting artifacts increased in DLRecon images, image interpretation was unaffected.


Assuntos
Aprendizado Profundo , Adulto , Idoso , Algoritmos , Artefatos , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Nervos Periféricos/diagnóstico por imagem
5.
Magn Reson Med ; 87(3): 1561-1573, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34708417

RESUMO

PURPOSE: To develop a deep-learning model that leverages the spatial and temporal information from dynamic contrast-enhanced magnetic resonance (DCE MR) brain imaging in order to automatically estimate a vascular function (VF) for quantitative pharmacokinetic (PK) modeling. METHODS: Patients with glioblastoma multiforme were scanned post-resection approximately every 2 months using a high spatial and temporal resolution DCE MR imaging sequence ( ≈5 s and ≈2 cm3 ). A region over the transverse sinus was manually drawn in the dynamic T1-weighted images to provide a ground truth VF. The manual regions and their resulting VF curves were used to train a deep-learning model based on a 3D U-net architecture. The model concurrently utilized the spatial and temporal information in DCE MR images to predict the VF. In order to analyze the contribution of the spatial and temporal terms, different weighted combinations were examined. The manual and deep-learning predicted regions and VF curves were compared. RESULTS: Forty-three patients were enrolled in this study and 155 DCE MR scans were processed. The 3D U-net was trained using a loss function that combined the spatial and temporal information with different weightings. The best VF curves were obtained when both spatial and temporal information were considered. The predicted VF curve was similar to the manual ground truth VF curves. CONCLUSION: The use of spatial and temporal information improved VF curve prediction relative to when only the spatial information is used. The method generalized well for unseen data and can be used to automatically estimate a VF curve suitable for quantitative PK modeling. This method allows for a more efficient clinical pipeline and may improve automation of permeability mapping.


Assuntos
Glioblastoma , Imageamento por Ressonância Magnética , Automação , Encéfalo/diagnóstico por imagem , Meios de Contraste , Glioblastoma/diagnóstico por imagem , Humanos , Espectroscopia de Ressonância Magnética
6.
Radiol Artif Intell ; 3(6): e200278, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34870214

RESUMO

PURPOSE: To evaluate two settings (noise reduction of 50% or 75%) of a deep learning (DL) reconstruction model relative to each other and to conventional MR image reconstructions on clinical orthopedic MRI datasets. MATERIALS AND METHODS: This retrospective study included 54 patients who underwent two-dimensional fast spin-echo MRI for hip (n = 22; mean age, 44 years ± 13 [standard deviation]; nine men) or shoulder (n = 32; mean age, 56 years ± 17; 17 men) conditions between March 2019 and June 2020. MR images were reconstructed with conventional methods and the vendor-provided and commercially available DL model applied with 50% and 75% noise reduction settings (DL 50 and DL 75, respectively). Quantitative analytics, including relative anatomic edge sharpness, relative signal-to-noise ratio (rSNR), and relative contrast-to-noise ratio (rCNR) were computed for each dataset. In addition, the image sets were randomized, blinded, and presented to three board-certified musculoskeletal radiologists for ranking based on overall image quality and diagnostic confidence. Statistical analysis was performed with a nonparametric hypothesis comparing derived quantitative metrics from each reconstruction approach. In addition, inter- and intrarater agreement analysis was performed on the radiologists' rankings. RESULTS: Both denoising settings of the DL reconstruction showed improved edge sharpness, rSNR, and rCNR relative to the conventional reconstructions. The reader rankings demonstrated strong agreement, with both DL reconstructions outperforming the conventional approach (Gwet agreement coefficient = 0.98). However, there was lower agreement between the readers on which DL reconstruction denoising setting produced higher-quality images (Gwet agreement coefficient = 0.31 for DL 50 and 0.35 for DL 75). CONCLUSION: The vendor-provided DL MRI reconstruction showed higher edge sharpness, rSNR, and rCNR in comparison with conventional methods; however, optimal levels of denoising may need to be further assessed.Keywords: MRI Reconstruction Method, Deep Learning, Image Analysis, Signal-to-Noise Ratio, MR-Imaging, Neural Networks, Hip, Shoulder, Physics, Observer Performance, Technology Assessment Supplemental material is available for this article. © RSNA, 2021.

7.
Acta Radiol Open ; 10(9): 20584601211044779, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34594576

RESUMO

BACKGROUND: Deep learning-based methods have been used to denoise magnetic resonance imaging. PURPOSE: The purpose of this study was to evaluate a deep learning reconstruction (DL Recon) in cardiovascular black-blood T2-weighted images and compare with intensity filtered images. MATERIAL AND METHODS: Forty-five DL Recon images were compared with intensity filtered and the original images. For quantitative image analysis, the signal to noise ratio (SNR) of the septum, contrast ratio (CR) of the septum to lumen, and sharpness of the endocardial border were calculated in each image. For qualitative image quality assessment, a 4-point subjective scale was assigned to each image (1 = poor, 2 = fair, 3 = good, 4 = excellent). RESULTS: The SNR and CR were significantly higher in the DL Recon images than in the intensity filtered and the original images (p < .05 in each). Sharpness of the endocardial border was significantly higher in the DL Recon and intensity filtered images than in the original images (p < .05 in each). The image quality of the DL Recon images was significantly better than that of intensity filtered and original images (p < .001 in each). CONCLUSIONS: DL Recon reduced image noise while improving image contrast and sharpness in the cardiovascular black-blood T2-weight sequence.

8.
Radiology ; 300(2): 410-420, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34100683

RESUMO

Background Advances in sub-Nyquist-sampled dynamic contrast-enhanced (DCE) MRI enable monitoring of brain tumors with millimeter resolution and whole-brain coverage. Such undersampled quantitative methods need careful characterization regarding achievable test-retest reproducibility. Purpose To demonstrate a fully automated high-resolution whole-brain DCE MRI pipeline with 30-fold sparse undersampling and estimate its reproducibility on the basis of reference regions of stable tissue types during multiple posttreatment time points by using longitudinal clinical images of high-grade glioma. Materials and Methods Two methods for sub-Nyquist-sampled DCE MRI were extended with automatic estimation of vascular input functions. Continuously acquired three-dimensional k-space data with ramped-up flip angles were partitioned to yield high-resolution, whole-brain tracer kinetic parameter maps with matched precontrast-agent T1 and M0 maps. Reproducibility was estimated in a retrospective study in participants with high-grade glioma, who underwent three consecutive standard-of-care examinations between December 2016 and April 2019. Coefficients of variation and reproducibility coefficients were reported for histogram statistics of the tracer kinetic parameters plasma volume fraction and volume transfer constant (Ktrans) on five healthy tissue types. Results The images from 13 participants (mean age ± standard deviation, 61 years ± 10; nine women) with high-grade glioma were evaluated. In healthy tissues, the protocol achieved a coefficient of variation less than 57% for median Ktrans, if Ktrans was estimated consecutively. The maximum reproducibility coefficient for median Ktrans was estimated to be at 0.06 min-1 for large or low-enhancing tissues and to be as high as 0.48 min-1 in smaller or strongly enhancing tissues. Conclusion A fully automated, sparsely sampled DCE MRI reconstruction with patient-specific vascular input function offered high spatial and temporal resolution and whole-brain coverage; in healthy tissues, the protocol estimated median volume transfer constant with maximum reproducibility coefficient of 0.06 min-1 in large, low-enhancing tissue regions and maximum reproducibility coefficient of less than 0.48 min-1 in smaller or more strongly enhancing tissue regions. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Lenkinski in this issue.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Glioma/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neoplasias Encefálicas/patologia , Meios de Contraste , Feminino , Glioma/patologia , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Reprodutibilidade dos Testes
9.
Magn Reson Med ; 86(4): 2234-2249, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34036658

RESUMO

PURPOSE: To develop and evaluate an efficient precontrast T1 mapping technique suitable for quantitative high-resolution whole-brain dynamic contrast-enhanced-magnetic resonance imaging (DCE-MRI). METHODS: Variable flip angle (VFA) T1 mapping was considered that provides 1 × 1 × 2 mm3 resolution to match a recent high-resolution whole-brain DCE-MRI protocol. Seven FAs were logarithmically spaced from 1.5° to 15°. T1 and M0 maps were estimated using model-based reconstruction. This approach was evaluated using an anatomically realistic brain tumor digital reference object (DRO) with noise-mimicking 3T neuroimaging and fully sampled data acquired from one healthy volunteer. Methods were also applied on fourfold prospectively undersampled VFA data from 13 patients with high-grade gliomas. RESULTS: T1 -mapping precision decreased with undersampling factor R, althoughwhereas bias remained small before a critical R. In the noiseless DRO, T1 bias was <25 ms in white matter (WM) and <11 ms in brain tumor (BT). T1 standard deviation (SD) was <119.5 ms in WM (coefficient of variation [COV] ~11.0%) and <253.2 ms in BT (COV ~12.7%). In the noisy DRO, T1 bias was <50 ms in WM and <30 ms in BT. For R ≤ 10, T1 SD was <107.1 ms in WM (COV ~9.9%) and <240.9 ms in BT (COV ~12.1%). In the healthy subject, T1 bias was <30 ms for R ≤ 16. At R = 4, T1 SD was 171.4 ms (COV ~13.0%). In the prospective brain tumor study, T1 values were consistent with literature values in WM and BT. CONCLUSION: High-resolution whole-brain VFA T1 mapping is feasible with sparse sampling, supporting its use for quantitative DCE-MRI.


Assuntos
Neoplasias Encefálicas , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Neoplasias Encefálicas/diagnóstico por imagem , Humanos , Neuroimagem , Estudos Prospectivos , Reprodutibilidade dos Testes
10.
NMR Biomed ; 34(5): e4245, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-31990112

RESUMO

In vivo quantification of glutamate (Glu) and γ-aminobutyric acid (GABA) using MRS is often achieved using two separate sequences: a short-echo point resolved spectroscopy (PRESS) acquisition for Glu and a Mescher-Garwood PRESS (MEGA-PRESS) acquisition for GABA. The purpose of this study was to examine the agreement of Glu and Glx (the combined signal of glutamate + glutamine) quantified from two different GABA-edited MEGA-PRESS acquisitions (GABA plus macromolecules, GABA+, TE = 68 ms, and macromolecule suppressed, MMSup, TE = 80 ms) with Glu and Glx quantified from a short-echo PRESS (PRESS-35, TE = 35 ms) acquisition. Fifteen healthy male volunteers underwent a single scan session, in which data were acquired using the three acquisitions (GABA+, MMSup and PRESS-35) in both the sensorimotor and anterior cingulate cortices using a voxel size of 3 × 3 × 3 cm3 . Glx and Glu were quantified from the MEGA-PRESS data using both the OFF sub-spectra and the difference (DIFF) spectra. Agreement was assessed using correlation analyses, Bland-Altman plots and intraclass correlation coefficients. Glx quantified from the OFF sub-spectra from both the GABA+ and MMSup acquisitions showed poor agreement with PRESS-35 in both brain regions. In the sensorimotor cortex, Glu quantified from the OFF sub-spectra of GABA+ showed moderate agreement with PRESS-35 data, but this finding was not replicated in the anterior cingulate cortex. Glx and Glu quantified using the DIFF spectra of either MEGA-PRESS sequence were in poor agreement with the PRESS-35 data in both brain regions. In conclusion, Glx and Glu measured from MEGA-PRESS data generally showed poor agreement with Glx and Glu measured using PRESS-35.


Assuntos
Ácido Glutâmico/metabolismo , Glutamina/metabolismo , Espectroscopia de Ressonância Magnética , Ácido gama-Aminobutírico/metabolismo , Adolescente , Adulto , Intervalos de Confiança , Giro do Cíngulo/diagnóstico por imagem , Humanos , Masculino , Córtex Sensório-Motor/diagnóstico por imagem , Adulto Jovem
11.
Eur Radiol ; 31(6): 3846-3855, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33219845

RESUMO

OBJECTIVES: The aim of this study was to assess the effect of a deep learning (DL)-based reconstruction algorithm on late gadolinium enhancement (LGE) image quality and to evaluate its influence on scar quantification. METHODS: Sixty patients (46 ± 17 years, 50% male) with suspected or known cardiomyopathy underwent CMR. Short-axis LGE images were reconstructed using the conventional reconstruction and a DL network (DLRecon) with tunable noise reduction (NR) levels from 0 to 100%. Image quality of standard LGE images and DLRecon images with 75% NR was scored using a 5-point scale (poor to excellent). In 30 patients with LGE, scar size was quantified using thresholding techniques with different standard deviations (SD) above remote myocardium, and using full width at half maximum (FWHM) technique in images with varying NR levels. RESULTS: DLRecon images were of higher quality than standard LGE images (subjective quality score 3.3 ± 0.5 vs. 3.6 ± 0.7, p < 0.001). Scar size increased with increasing NR levels using the SD methods. With 100% NR level, scar size increased 36%, 87%, and 138% using 2SD, 4SD, and 6SD quantification method, respectively, compared to standard LGE images (all p values < 0.001). However, with the FWHM method, no differences in scar size were found (p = 0.06). CONCLUSIONS: LGE image quality improved significantly using a DL-based reconstruction algorithm. However, this algorithm has an important impact on scar quantification depending on which quantification technique is used. The FWHM method is preferred because of its independency of NR. Clinicians should be aware of this impact on scar quantification, as DL-based reconstruction algorithms are being used. KEY POINTS: • The image quality based on (subjective) visual assessment and image sharpness of late gadolinium enhancement images improved significantly using a deep learning-based reconstruction algorithm that aims to reconstruct high signal-to-noise images using a denoising technique. • Special care should be taken when scar size is quantified using thresholding techniques with different standard deviations above remote myocardium because of the large impact of these advanced image enhancement algorithms. • The full width at half maximum method is recommended to quantify scar size when deep learning algorithms based on noise reduction are used, as this method is the least sensitive to the level of noise and showed the best agreement with visual late gadolinium enhancement assessment.


Assuntos
Aprendizado Profundo , Gadolínio , Algoritmos , Cicatriz/diagnóstico por imagem , Cicatriz/patologia , Meios de Contraste , Feminino , Humanos , Aumento da Imagem , Imageamento por Ressonância Magnética , Masculino , Miocárdio/patologia
12.
Neuroimage ; 223: 117371, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32931943

RESUMO

BACKGROUND: Arterial Spin Labeling (ASL) MRI can provide quantitative images that are sensitive to both time averaged blood flow and its temporal fluctuations. 3D image acquisitions for ASL are desirable because they are more readily compatible with background suppression to reduce noise, can reduce signal loss and distortion, and provide uniform flow sensitivity across the brain. However, single-shot 3D acquisition for maximal temporal resolution typically involves degradation of image quality through blurring or noise amplification by parallel imaging. Here, we report a new approach to accelerate a common stack of spirals 3D image acquisition by pseudo golden-angle rotation and compressed sensing reconstruction without any degradation of time averaged blood flow images. METHODS: 28 healthy volunteers were imaged at 3T with background-suppressed unbalanced pseudo-continuous ASL combined with a pseudo golden-angle Stack-of-Spirals 3D RARE readout. A fully-sampled perfusion-weighted volume was reconstructed by 3D non-uniform Fast Fourier Transform (nuFFT) followed by sum-of-squares combination of the 32 individual channels. Coil sensitivities were estimated followed by reconstruction of the 39 single-shot volumes using an L1-wavelet Compressed-Sensing reconstruction. Finally, brain connectivity analyses were performed in regions where BOLD signal suffers from low signal-to-noise ratio and susceptibility artifacts. RESULTS: Image quality, assessed with a non-reference 3D blurring metric, of full time averaged blood flow was comparable to a conventional interleaved acquisition. The temporal resolution provided by the acceleration enabled identification and quantification of resting-state networks even in inferior regions such as the amygdala and inferior frontal lobes, where susceptibility artifacts can degrade conventional resting-state fMRI acquisitions. CONCLUSION: This approach can provide measures of blood flow modulations and resting-state networks for free within any research or clinical protocol employing ASL for resting blood flow.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Artefatos , Encéfalo/anatomia & histologia , Feminino , Humanos , Masculino , Razão Sinal-Ruído , Marcadores de Spin , Adulto Jovem
13.
PLoS One ; 15(8): e0233244, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32797080

RESUMO

The role of white matter in reading has been established by diffusion tensor imaging (DTI), but DTI cannot identify specific microstructural features driving these relationships. Neurite orientation dispersion and density imaging (NODDI), inhomogeneous magnetization transfer (ihMT) and multicomponent driven equilibrium single-pulse observation of T1/T2 (mcDESPOT) can be used to link more specific aspects of white matter microstructure and reading due to their sensitivity to axonal packing and fiber coherence (NODDI) and myelin (ihMT and mcDESPOT). We applied principal component analysis (PCA) to combine DTI, NODDI, ihMT and mcDESPOT measures (10 in total), identify major features of white matter structure, and link these features to both reading and age. Analysis was performed for nine reading-related tracts in 46 neurotypical 6-16 year olds. We identified three principal components (PCs) which explained 79.5% of variance in our dataset. PC1 probed tissue complexity, PC2 described myelin and axonal packing, while PC3 was related to axonal diameter. Mixed effects regression models did not identify any significant relationships between principal components and reading skill. Bayes factor analysis revealed that the absence of relationships was not due to low power. Increasing PC1 in the left arcuate fasciculus with age suggest increases in tissue complexity, while increases of PC2 in the bilateral arcuate, inferior longitudinal, inferior fronto-occipital fasciculi, and splenium suggest increases in myelin and axonal packing with age. Multimodal white matter imaging and PCA provide microstructurally informative, powerful principal components which can be used by future studies of development and cognition. Our findings suggest major features of white matter undergo development during childhood and adolescence, but changes are not linked to reading during this period in our typically-developing sample.


Assuntos
Neuroimagem Funcional/métodos , Imageamento por Ressonância Magnética Multiparamétrica/métodos , Leitura , Substância Branca/anatomia & histologia , Adolescente , Desenvolvimento do Adolescente/fisiologia , Axônios/ultraestrutura , Teorema de Bayes , Criança , Desenvolvimento Infantil/fisiologia , Imagem de Tensor de Difusão/estatística & dados numéricos , Feminino , Neuroimagem Funcional/estatística & dados numéricos , Voluntários Saudáveis , Humanos , Imageamento Tridimensional , Masculino , Modelos Anatômicos , Modelos Neurológicos , Imageamento por Ressonância Magnética Multiparamétrica/estatística & dados numéricos , Bainha de Mielina/metabolismo , Análise de Componente Principal/métodos , Análise de Regressão , Substância Branca/crescimento & desenvolvimento , Substância Branca/fisiologia
14.
Magn Reson Med ; 84(6): 2964-2980, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32602958

RESUMO

PURPOSE: To demonstrate the feasibility of integrating the magnetization transfer (MT) preparations required for inhomogeneous MT (ihMT) within an MPRAGE-style acquisition. Such a sequence allows for reduced power deposition and easy inclusion of other modules. METHODS: An ihMT MPRAGE-style sequence (ihMTRAGE) was initially simulated to investigate acquisition of the 3D ihMT data sequentially, or in an interleaved manner. The ihMTRAGE sequence was implemented on a 3T clinical scanner to acquire ihMT data from the brain and spine. RESULTS: Both simulations and in vivo data provided an ihMT signal that was significantly greater using a sequential ihMTRAGE acquisition, compared with an interleaved implementation. Comparison with a steady-state ihMT acquisition (defined as having one MT RF pulse between successive acquisition modules) demonstrated how ihMTRAGE allows for a reduction in average power deposition, or greater ihMT signal at equal average power deposition. Inclusion of a prospective motion-correction module did not significantly affect the ihMT signal obtained from regions of interest in the brain. The ihMTRAGE acquisition allowed combination with a spatial saturation module to reduce phase wrap artifacts in a cervical spinal cord acquisition. CONCLUSIONS: Use of preparations necessary for ihMT experiments within an MPRAGE-style sequence provides a useful alternative for acquiring 3D ihMT data. Compared with our steady-state implementation, ihMTRAGE provided reduced power deposition, while allowing use of the maximum intensity from off-resonance RF pulses. The 3D ihMTRAGE acquisition allowed combination of other modules with the preparation necessary for ihMT experiments, specifically motion compensation and spatial saturation modules.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Artefatos , Encéfalo/diagnóstico por imagem , Imageamento Tridimensional , Estudos Prospectivos
15.
Magn Reson Imaging ; 71: 140-153, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32562744

RESUMO

The U-net is a deep-learning network model that has been used to solve a number of inverse problems. In this work, the concatenation of two-element U-nets, termed the W-net, operating in k-space (K) and image (I) domains, were evaluated for multi-channel magnetic resonance (MR) image reconstruction. The two-element network combinations were evaluated for the four possible image-k-space domain configurations: a) W-net II, b) W-net KK, c) W-net IK, and d) W-net KI. Selected four element (WW-nets) and six element (WWW-nets) networks were also examined. Two configurations of each network were compared: 1) each coil channel was processed independently, and 2) all channels were processed simultaneously. One hundred and eleven volumetric, T1-weighted, 12-channel coil k-space datasets were used in the experiments. Normalized root mean squared error, peak signal-to-noise ratio and visual information fidelity were used to assess the reconstructed images against the fully sampled reference images. Our results indicated that networks that operate solely in the image domain were better when independently processing individual channels of multi-channel data. Dual-domain methods were better when simultaneously reconstructing all channels of multi-channel data. In addition, the best cascade of U-nets performed better (p < 0.01) than the previously published, state-of-the-art Deep Cascade and Hybrid Cascade models in three out of four experiments.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Algoritmos , Humanos , Razão Sinal-Ruído
16.
J Neurosci Res ; 98(8): 1517-1531, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32476173

RESUMO

Arterial spin labeling (ASL) MRI can provide seizure onset zone (SOZ) localizing information in up to 80% of patients. Clinical implementation of this technique is limited by the need to obtain two scans per patient: a postictal scan that is subtracted from an interictal scan. We aimed to determine whether it is possible to limit the number of ASL scans to one per patient by comparing patient postictal ASL scans to baseline scans of 100 healthy controls. Eighteen patients aged 20-55 years underwent ASL MRI <90 min after a seizure and during the interictal period. Each postictal cerebral blood flow (CBF) map was statistically compared to average baseline CBF maps from 100 healthy controls (pvcASL; patient postictal CBF vs. control baseline CBF). The pvcASL maps were compared to subtraction ASL maps (sASL; patient baseline CBF minus patient postictal CBF). Postictal CBF reductions from pvcASL and sASL maps were seen in 17 of 18 (94.4%) and 14 of 18 (77.8%) patients, respectively. Maximal postictal hypoperfusion seen in pvcASL and sASL maps was concordant with the SOZ in 10 of 17 (59%) and 12 of 14 (86%) patients, respectively. In seven patients, both pvcASL and sASL maps showed similar results. In two patients, sASL showed no significant hypoperfusion, while pvcASL showed significant hypoperfusion concordant with the SOZ. We conclude that pvcASL is clinically useful and although it may have a lower overall concordance rate than sASL, pvcASL does provide localizing or lateralizing information for specific cases that would be otherwise missed through sASL.


Assuntos
Encéfalo/fisiologia , Circulação Cerebrovascular/fisiologia , Epilepsia do Lobo Temporal/diagnóstico , Convulsões/diagnóstico , Adulto , Encéfalo/diagnóstico por imagem , Eletroencefalografia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
17.
Brain Inj ; 34(7): 895-904, 2020 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-32396403

RESUMO

PRIMARY OBJECTIVE: The neurophysiological effects of pediatric concussion several years after injury remain inadequately characterized. The objective of this study was to determine if a history of concussion was associated with BOLD response differences during an n-back working memory task in youth. RESEARCH DESIGN: Observational, cross-sectional. METHODS AND PROCEDURES: Participants include 52 children and adolescents (M = 15.1 years, 95%CI = 14.4-15.8, range = 9-19) with past concussion (n = 33) or orthopedic injury (OI; n = 19). Mean time since injury was 2.5 years (95%CI = 2.0-3.0). Measures included postconcussion symptom ratings, neuropsychological testing, and blood-oxygen-dependent-level (BOLD) functional magnetic resonance imaging (fMRI) during an n-back working memory task. MAIN OUTCOMES AND RESULTS: Groups did not differ on accuracy or speed during the three n-back conditions. They also did not differ in BOLD signal change for the 1- vs. 0-back or 2- vs. 0-back contrasts (controlling for task performance). CONCLUSIONS: This study does not support group differences in BOLD response during an n-back working memory task in youth who are on average 2.5 years post-concussion. The findings are encouraging from the perspective of understanding recovery after pediatric concussion.


Assuntos
Concussão Encefálica , Síndrome Pós-Concussão , Adolescente , Concussão Encefálica/diagnóstico por imagem , Criança , Estudos Transversais , Humanos , Imageamento por Ressonância Magnética , Memória de Curto Prazo , Testes Neuropsicológicos
18.
Radiology ; 295(1): 171-180, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32043950

RESUMO

Background The hardware and software differences between MR vendors and individual sites influence the quantification of MR spectroscopy data. An analysis of a large data set may help to better understand sources of the total variance in quantified metabolite levels. Purpose To compare multisite quantitative brain MR spectroscopy data acquired in healthy participants at 26 sites by using the vendor-supplied single-voxel point-resolved spectroscopy (PRESS) sequence. Materials and Methods An MR spectroscopy protocol to acquire short-echo-time PRESS data from the midparietal region of the brain was disseminated to 26 research sites operating 3.0-T MR scanners from three different vendors. In this prospective study, healthy participants were scanned between July 2016 and December 2017. Data were analyzed by using software with simulated basis sets customized for each vendor implementation. The proportion of total variance attributed to vendor-, site-, and participant-related effects was estimated by using a linear mixed-effects model. P values were derived through parametric bootstrapping of the linear mixed-effects models (denoted Pboot). Results In total, 296 participants (mean age, 26 years ± 4.6; 155 women and 141 men) were scanned. Good-quality data were recorded from all sites, as evidenced by a consistent linewidth of N-acetylaspartate (range, 4.4-5.0 Hz), signal-to-noise ratio (range, 174-289), and low Cramér-Rao lower bounds (≤5%) for all of the major metabolites. Among the major metabolites, no vendor effects were found for levels of myo-inositol (Pboot > .90), N-acetylaspartate and N-acetylaspartylglutamate (Pboot = .13), or glutamate and glutamine (Pboot = .11). Among the smaller resonances, no vendor effects were found for ascorbate (Pboot = .08), aspartate (Pboot > .90), glutathione (Pboot > .90), or lactate (Pboot = .28). Conclusion Multisite multivendor single-voxel MR spectroscopy studies performed at 3.0 T can yield results that are coherent across vendors, provided that vendor differences in pulse sequence implementation are accounted for in data analysis. However, the site-related effects on variability were more profound and suggest the need for further standardization of spectroscopic protocols. © RSNA, 2020 Online supplemental material is available for this article.


Assuntos
Encéfalo/metabolismo , Comércio , Espectroscopia de Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Masculino , Estudos Prospectivos , Adulto Jovem
19.
Pediatr Neurol ; 103: 79-83, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31570299

RESUMO

OBJECTIVES: We attempted to demonstrate the clinical applicability and utility of a three-dimensional multidelay arterial spin labeling magnetic resonance imaging technique in pediatric neuroimaging through a series of case studies. METHODS: Whole-brain three-dimensional multidelay arterial spin labeling data were acquired in five pediatric patients with different neurological conditions using 3 mm to 4 mm slices and a scan time of six to seven minutes. RESULTS: Three-dimensional multidelay arterial spin labeling provided complementary diagnostic information via quantitative cerebral blood flow and arterial transit time maps. CONCLUSIONS: Three-dimensional multidelay arterial spin labeling sequence provides simultaneous quantification of cerebral blood flow and arterial transit time and is feasible for pediatric patients.


Assuntos
Encefalopatias/diagnóstico por imagem , Circulação Cerebrovascular , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Adolescente , Neoplasias Encefálicas/diagnóstico por imagem , Circulação Cerebrovascular/fisiologia , Criança , Estudos de Viabilidade , Humanos , Hipóxia-Isquemia Encefálica/diagnóstico por imagem , Lactente , Recém-Nascido , Transtornos de Enxaqueca/diagnóstico por imagem , Doença de Moyamoya/diagnóstico por imagem , Estudos Retrospectivos , Espasmos Infantis/diagnóstico por imagem , Marcadores de Spin
20.
Neuroimage ; 204: 116224, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31561017

RESUMO

Adequate cerebral blood flow (CBF) is essential to proper brain development and function. Detailed characterization of CBF developmental trajectories will lead to better understanding of the development of cognitive, motor, and sensory functions, as well as behaviour in children. Previous studies have shown CBF increases during infancy and decreases during adolescence; however, the trajectories during childhood, and in particular the timing of peak CBF, remain unclear. Here, we used arterial spin labeling to map age-related changes of CBF across a large longitudinal sample that included 279 scans on 96 participants (46 girls and 50 boys) aged 2-7 years. CBF maps were analyzed using hierarchical linear regression for every voxel inside the grey matter mask, controlling for multiple comparisons. The results revealed a significant positive linear association between CBF and age in distributed brain regions including prefrontal, temporal, parietal, and occipital cortex, and in the cerebellum. There were no differences in developmental trajectories between males and females. Our findings show that CBF continues to increase until the age of 7 years, likely supporting ongoing improvements in behaviour, cognition, motor, and sensory functions in early childhood.


Assuntos
Cerebelo/fisiologia , Córtex Cerebral/fisiologia , Circulação Cerebrovascular/fisiologia , Desenvolvimento Infantil/fisiologia , Cerebelo/diagnóstico por imagem , Cerebelo/crescimento & desenvolvimento , Córtex Cerebral/diagnóstico por imagem , Córtex Cerebral/crescimento & desenvolvimento , Criança , Pré-Escolar , Feminino , Humanos , Estudos Longitudinais , Imageamento por Ressonância Magnética , Masculino , Neuroimagem , Marcadores de Spin
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...