Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
J Visc Surg ; 155(6): 483-492, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30448206

RESUMO

The management of patients with sporadic pancreatic neuroendocrine tumors (PNET) is multi-disciplinary and often, multimodal. Surgery has a large part in treatment because it is the only potentially curative therapeutic modality if resection can be complete. The update reviews the operative indications and the different surgical techniques available (including parenchymal-sparing surgery) to treat the primary lesion according to patient status, preoperative work-up and whether the tumor is functioning or not. The place of observation for "small" non-functional sporadic PNET is also discussed.


Assuntos
Tumores Neuroendócrinos/cirurgia , Neoplasias Pancreáticas/cirurgia , Gastrinoma/cirurgia , Humanos , Achados Incidentais , Insulinoma/cirurgia , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/cirurgia , Terapia Neoadjuvante , Tumores Neuroendócrinos/diagnóstico por imagem , Tratamentos com Preservação do Órgão , Neoplasias Pancreáticas/diagnóstico por imagem , Pancreaticoduodenectomia/métodos , Tomografia Computadorizada por Raios X
2.
J Visc Surg ; 155(2): 117-125, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29397338

RESUMO

The management of patients with pancreatic neuroendocrine tumor (PNET), whether hormonally secretory or not, is multidisciplinary and often multimodal. Surgical treatment plays a central role because complete resection is the only potentially curative treatment. The choice of the therapeutic plan for a PNET requires precise localization of the primary tumor (which may sometimes be multiple in case of genetic predisposition), confirmation of the diagnosis of PNET, a search for metastases (mainly hepatic), and identification of the main histoprognostic factors. This update focuses on the WHO 2017 histological classification and recent innovations in the preoperative assessment of PNET using conventional and isotopic imaging. The aim is to not only allow the mapping of primary and metastatic lesions but also to predict tumor aggressiveness.


Assuntos
Imagem Multimodal/métodos , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/patologia , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Biópsia por Agulha Fina , Diagnóstico por Imagem/métodos , Feminino , Humanos , Imuno-Histoquímica , Imageamento por Ressonância Magnética/métodos , Masculino , Tumores Neuroendócrinos/cirurgia , Pancreatectomia/métodos , Neoplasias Pancreáticas/cirurgia , Tomografia por Emissão de Pósitrons/métodos , Cuidados Pré-Operatórios/métodos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia Doppler/métodos
4.
Endocr Relat Cancer ; 16(3): 977-90, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19470616

RESUMO

Liver metastases are common in gastroenteropancreatic neuroendocrine tumors and significantly impair survival. Hepatic resection is the only potential curative treatment. The records of 41 consecutive patients undergoing exhaustive resection of liver-only endocrine metastases and followed between 1992 and 2006 were reviewed. Patient's outcome and diagnostic accuracy of somatostatin receptor scintigraphy (SRS) and morphological imaging (MI) for detection of recurrences during post-operative follow-up were assessed. All identified primary had been resected. MI studies including abdominal computed tomography (CT) and/or liver magnetic resonance imaging and thoracic CT if indicated were performed every 6 months; SRS timing was decided by referring clinician. Tumor recurrences were confirmed by pathology or subsequent imaging studies. The results of 136 MI and SRS examinations performed within a 30-day interval from each other were retrospectively compared. Median post-operative follow-up was 51 months (7-165). Recurrences developed in 32 patients (78%), mainly in the liver (n=24) after a median of 19 months (2-79). Five-year overall and disease-free survival rates were 79 and 3% respectively. For recurrence detection, sensitivity, specificity, and accuracy were 89, 94, and 91% for SRS, 68, 91, and 74% for MI respectively. In 11 out of 32 patients (34%), abdominal or extra-abdominal metastases were detected 15.5 months earlier by SRS than MI. In conclusion, despite exhaustive liver surgery for endocrine metastases, hepatic or extra-hepatic recurrences are frequent and develop early. SRS is highly accurate for the detection of recurrences during post-operative follow-up and permitted early diagnosis in one third of patients; therapeutic implications of this early diagnosis remain to be determined.


Assuntos
Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/cirurgia , Tumores Neuroendócrinos/diagnóstico , Tumores Neuroendócrinos/secundário , Tumores Neuroendócrinos/cirurgia , Adulto , Idoso , Diagnóstico por Imagem/métodos , Feminino , Seguimentos , Neoplasias Gastrointestinais/diagnóstico , Neoplasias Gastrointestinais/mortalidade , Neoplasias Gastrointestinais/patologia , Hepatectomia/métodos , Humanos , Neoplasias Hepáticas/mortalidade , Masculino , Pessoa de Meia-Idade , Tumores Neuroendócrinos/mortalidade , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/mortalidade , Neoplasias Pancreáticas/patologia , Período Pós-Operatório , Valor Preditivo dos Testes , Prognóstico , Receptores de Somatostatina/metabolismo , Estudos Retrospectivos , Tomografia Computadorizada de Emissão/métodos , Adulto Jovem
5.
Br J Cancer ; 98(5): 875-80, 2008 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-18301402

RESUMO

We assessed the potential benefits of including systematic 18fluorodeoxyglucose positron emission tomography (FDG-PET) for detecting tumour recurrence in a prospective randomised trial. Patients (N=130) who had undergone curative therapy were randomised to undergo either conventional (Con) or FDG-PET procedures during follow-up. The two groups were matched at baseline. Recurrence was confirmed histologically. 'Intention-to-treat' analysis revealed a recurrence in 46 patients (25 in the FDG-PET group, and 21 in the Con group; P=0.50), whereas per protocol analysis revealed a recurrence in 44 out of 125 patients (23 and 21, respectively; P=0.60). In another three cases, PET revealed unexpected tumours (one gastric GIST, two primary pulmonary cancers). Three false-positive cases of FDG-PET led to no beneficial procedures (two laparoscopies and one liver MRI that were normal). We failed to identify peritoneal carcinomatosis in two of the patients undergoing FDG-PET. The overall time in detecting a recurrence from the baseline was not significantly different in the two groups. However, recurrences were detected after a shorter time (12.1 vs 15.4 months; P=0.01) in the PET group, in which recurrences were also more frequently (10 vs two patients) cured by surgery (R0). Regular FDG-PET monitoring in the follow up of colorectal cancer patients may permit the earlier detection of recurrence, and influence therapy strategies.


Assuntos
Neoplasias Colorretais/diagnóstico por imagem , Fluordesoxiglucose F18 , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Adulto , Idoso , Seguimentos , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
6.
Thorax ; 63(3): 251-8, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17951277

RESUMO

BACKGROUND AND AIM: Somatostatin analogues may have antifibrotic properties in the lung. The aim of this study was to evaluate the expression of the five somatostatin receptors sst1 to sst5 in normal and fibrotic mouse lung and the action of SOM230 (pasireotide), a new somatostatin analogue with a long half-life, in bleomycin induced lung fibrosis and in human lung fibroblasts in vitro. METHODS: After intratracheal injection of bleomycin, C57Bl6 male mice received one daily subcutaneous injection of SOM230 or saline. The lungs were evaluated on days 3, 7 and 14 after administration of bleomycin. RESULTS: We found that all somatostatin receptors were expressed in the normal mouse lung. The sst2 receptor mRNA expression was increased after bleomycin. SOM230 improved mice survival (69% vs 44%; p = 0.024), reduced lung collagen content at day 14 and decreased lung collagen-1 mRNA at day 7. SOM230 reduced bronchoalveolar lavage inflammatory cell influx at day 3, decreased lung connective tissue growth factor mRNA and transforming growth factor (TGF) beta mRNA and increased lung hepatocyte growth factor and keratinocyte growth factor mRNA. The sst2 receptor was strongly expressed in the human lung (normal or fibrotic), particularly by fibroblasts. In vitro, SOM230 reduced BrdU incorporation by control human lung fibroblasts cultured under basal conditions or with TGFbeta, and reduced alpha-1 collagen-1 mRNA expression in TGFbeta stimulated fibroblasts. CONCLUSION: We conclude that SOM230 attenuates bleomycin induced pulmonary fibrosis in mice and human lung fibroblasts activation. This study points to a potential new approach for treating pulmonary fibrotic disorders.


Assuntos
Fibrose Pulmonar/tratamento farmacológico , Receptores de Somatostatina/metabolismo , Somatostatina/análogos & derivados , Animais , Antibióticos Antineoplásicos/farmacologia , Bleomicina/farmacologia , Imuno-Histoquímica , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Fibrose Pulmonar/metabolismo , RNA Mensageiro/metabolismo , Somatostatina/farmacologia , Fator de Crescimento Transformador alfa/farmacologia
8.
Nucl Med Commun ; 24(12): 1215-24, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14627847

RESUMO

We prospectively compared the impact of the standard approach, of fluorodeoxyglucose positron emission tomography (FDG PET) and of FDG dual-head coincidence gamma camera imaging (DHC) in preoperative staging of patients with non-small-cell lung cancer (NSCLC). In addition to traditional staging, 42 patients were studied with a PET system and a DHC system. The number of lesions detected on DHC and on PET were compared independently of the proof of a tumoural invasion. Then, for the sub-group of lesions with the proof of a tumoural invasion, the sensitivity of the different imaging modalities was compared. Finally, stagings were compared with final staging established by histopathological findings (n=28), additional imaging modalities (n=4), clinical and traditional imaging follow-up over at least 4 months. DHC detected 105 of the 145 lesions considered as pathological on PET (73%, P=0.01), with a concurrence of 89% (NS) in lesions larger than 1.5 cm, and only 17% (P=0.03) in those smaller or equal to 1 cm. Traditional staging detected 87 of the 114 verified tumoural lesions (76%), PET 110/114 (96%, P=0.01 vs traditional staging), DHC 88/114 (77%, NS vs traditional staging, P=0.01 vs PET). PET correctly predicted the N stage in 39/42 (93%) patients, DHC in 38/42 (90%), and computed tomography in 32/42 (76%). PET correctly predicted the M stage in 42/42 (100%) patients, DHC in 41/42 (98%), and traditional staging in 38/42 (90%). Identical NM staging was obtained with DHC and PET in 38/42 (90%) patients. Compared to traditional NM staging, PET correctly up-staged 9/42 (21%) patients and down-staged 3/42 (7%), with one additional false N up-staging. DHC correctly up-staged 7/42 (17%) patients and down-staged 3/42 (7%), with one additional false N down-staging. PET correctly reclassified 4/42 (9.5%) patients from resectable to unresectable and incorrectly reclassified one. DHC correctly reclassified 3/42 (7%) patients without false therapeutic reclassification. Although DHC detected fewer lesions than PET, DHC is a possible alternative to PET since the impact on staging was high as compared with traditional staging and was very similar to that of PET.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Fluordesoxiglucose F18 , Câmaras gama , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada de Emissão/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/patologia , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias/métodos , Cuidados Pré-Operatórios/métodos , Cintilografia/métodos , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão/instrumentação
9.
Br J Radiol ; 74(887): 1065-70, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11709476

RESUMO

Endocrine tumours of the pancreas (ETPs) are rare neoplasms that are frequently malignant. Despite their usual slow growth, metastases do occur and have a major impact on prognosis. Metastases may be the first manifestation of disease, and recognition of particular radiological features of these hypervascular metastases should suggest their possible neuroendocrine origin. Although somatostatin receptor scintigraphy has changed the imaging strategy for these tumours and has become their principal imaging modality, radiological techniques are still required for precise localization of scintigraphic hot spots and monitoring of response to therapy. This pictorial review shows the typical radiological features of ETP metastases and emphasizes the role of different imaging modalities.


Assuntos
Tumores Neuroendócrinos/diagnóstico , Tumores Neuroendócrinos/secundário , Neoplasias Pancreáticas/diagnóstico , Neoplasias Ósseas/diagnóstico , Neoplasias Ósseas/secundário , Gastrinoma/diagnóstico , Gastrinoma/secundário , Humanos , Insulinoma/diagnóstico , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/secundário , Imageamento por Ressonância Magnética , Neoplasias Peritoneais/diagnóstico , Neoplasias Peritoneais/secundário , Cintilografia , Receptores de Somatostatina/metabolismo , Neoplasias da Coluna Vertebral/diagnóstico , Neoplasias da Coluna Vertebral/secundário , Tomografia Computadorizada por Raios X , Vipoma/diagnóstico , Vipoma/secundário
10.
J Am Coll Cardiol ; 37(3): 786-92, 2001 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-11693753

RESUMO

OBJECTIVES: The aim of this study was to assess the diagnosis of myocarditis in patients presenting with acute myocardial infarction (MI) and normal coronary angiograms. BACKGROUND: Most often in these patients, the etiologic diagnosis remains unclear once they are found to have normal coronary arteries. The diagnosis of myocarditis mimicking MI is clinically relevant, because numerous arguments suggest a relation between myocarditis and dilated cardiomyopathy. Myocardial indium-111 (111In)-antimyosin antibody (AMA)/rest thallium-201 (201Tl) imaging allows noninvasive detection of myocarditis. METHODS: Forty-five patients admitted to three intensive care units for suspicion of acute MI, with normal coronary angiograms, were investigated. Indium-111-AMA planar images and then a dual-isotope rest AMA/201Tl tomographic study were performed. Six-month echocardiographic follow-up was obtained in 80% of the patients with initial left ventricular (LV) wall motion abnormalities. RESULTS: In eight patients, AMA and 201Tl scintigraphy were negative. In two patients, a matched 201Tl defect and focal AMA uptake suggested acute MI (due to prolonged vasospasm or spontaneously reperfused coronary occlusion). In 17 patients, diffuse AMA uptake over the whole LV suggested diffuse myocarditis. In 18 patients, focal AMA uptake with a normal 201Tl scan suggested diffuse but heterogeneous, or focal myocarditis. Complete functional recovery was observed in 81% of the patients with a pattern of myocarditis. CONCLUSIONS: Among 45 patients presenting with acute MI and normal coronary angiograms, 38% had diffuse myocarditis and 40% had a scintigraphic pattern of heterogeneous or focal myocarditis. Short-term follow-up showed complete LV functional recovery in 81% of these patients.


Assuntos
Infarto do Miocárdio/diagnóstico , Miocardite/diagnóstico , Adulto , Anticorpos Monoclonais/imunologia , Angiografia Coronária , Eletrocardiografia , Feminino , Humanos , Radioisótopos de Índio , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Miocardite/diagnóstico por imagem , Miocardite/fisiopatologia , Compostos Organometálicos/imunologia , Estudos Prospectivos , Cintilografia , Ultrassonografia , Função Ventricular Esquerda
11.
J Nucl Med ; 42(10): 1451-6, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11585856

RESUMO

UNLABELLED: A lack of specificity for myocardial perfusion imaging has been widely reported, mostly related to false-positive defects on the inferior wall. The application of depth-dependent resolution recovery (RR), attenuation correction (AC) using external source devices, and scatter correction has been proposed to resolve this pitfall. METHODS: We studied the clinical benefit of depth-dependent RR, nonuniform AC using a scanning line source, and scatter correction (photon energy recovery [PER]) compared with filtered backprojection alone. Eighty-two patients were included: 40 healthy volunteers with a low likelihood of coronary artery disease (control group) and 42 patients with proven right or circumflex coronary artery disease but without involvement of the left anterior descending artery. Among these 82 patients, the images of 33 were also processed with PER. RESULTS: RR did not alter the performance of filtered backprojection alone. AC + RR greatly improved specificity and the rate of normal (201)Tl SPECT findings in the control population (from 56% to 95% and from 53% to 100%, respectively) but significantly decreased sensitivity (from 92% to 54%). AC + RR generated a false anteroapical defect in 21% of patients and reverse redistribution of the apex in 23%. AC + RR significantly decreased the extent of the stress defect (from 4.09 to 3.21 segments, P < 0.003) and increased the perfusion score of the stress defect (from 0.78 +/- 0.72 to 1.47 +/- 1.11, P < 0.00061). Moreover, AC + RR generated overcorrection on the inferior wall, leading to false estimation of viability for 11 of 15 patients with an old inferior myocardial scar without evidence of residual viability. PER decreased overcorrection on the inferior wall, but without improving sensitivity. PER did not significantly reduce the number of anteroapical false-positives or the number of apical reverse distribution cases. CONCLUSION: AC + RR improved the specificity and normalcy rate of (201)Tl SPECT myocardial perfusion imaging but generated overcorrection on the inferior wall, leading to low sensitivity and to false evaluation of myocardial viability in 73% of the patients with inferior infarction. AC + RR also generated anteroapical artifacts. The addition of scatter correction did not significantly reduce these drawbacks.


Assuntos
Circulação Coronária , Doença das Coronárias/diagnóstico por imagem , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único , Dipiridamol , Teste de Esforço , Humanos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Sensibilidade e Especificidade
12.
J Nucl Med ; 42(7): 1043-9, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11438625

RESUMO

UNLABELLED: The current major limitation to development of electrocardiographically (ECG) gated blood-pool SPECT (GBPS) for measurement of the left ventricular (LV) ejection fraction (LVEF) and volumes is the lack of availability of clinically validated automatic processing software. Recently, 2 processing software methods for quantification of the LV function have been described. Their LVEFs have been validated separately, but no validation of the LV volume measurement has been reported. METHODS: We compared 3 processing methods for evaluation of the LVEF (n = 29) and volumes (n = 58) in 29 patients: automatic geometric method (GBPS(G)), semiautomatic activity method (GBPS(M)), and 35% maximal activity manual method (GBPS(35%)). The LVEF provided by the ECG gated equilibrium planar left anterior oblique view (planar(LAO)) and the LV volumes provided by LV digital angiography (Rx) were used as gold standards. RESULTS: Whereas the GBPS(G) and GBPS(M) methods present similar low percentage variabilities, the GBPS(35%) method provided the lowest percentage variabilities for the LVEF and volume measurements (P < 0.04 and P < 0.02, respectively). The LVEF and volume provided by the 3 methods were highly correlated with the gold standard methods (r > 0.98 and r > 0.83, respectively). The LVEFs provided by the GBPS(35%) and GBPS(M) methods are similar and higher than those of the GBPS(G) method and planar(LAO) method, respectively (P < 0.0001). For the LVEF, there is no correlation between the average and paired absolute difference for the 3 GBPS methods against the planar(LAO) method, and the limits of agreement are relatively large. LV volumes are lower when calculated with the GBPS(M), GBPS(G), and Rx methods (P < 0.0001). However, the GBPS(35%) and Rx methods provide LV volumes that are similar. There is no linear correlation between the average and the paired absolute difference of volumes calculated with the GBPS(G) and GBPS(35%) methods against Rx LV volumes. However, a moderate linear correlation was found with the GBPS(M) method (r = 0.6; P = 0.0001). The 95% limits of agreement between the Rx LV volumes and the 3 GBPS methods are relatively large. CONCLUSION: GBPS is a simple, highly reproducible, and accurate technique for the LVEF and volume measurement. The reported findings should be considered when comparing results of different methods (GBPS vs. planar(LAO) LVEF; GBPS vs. Rx volume) and results of different GBPS processing methods.


Assuntos
Eletrocardiografia , Imagem do Acúmulo Cardíaco de Comporta , Processamento de Imagem Assistida por Computador/métodos , Volume Sistólico , Tomografia Computadorizada de Emissão de Fóton Único , Função Ventricular Esquerda , Humanos , Masculino , Pessoa de Meia-Idade , Angiografia Cintilográfica , Processamento de Sinais Assistido por Computador , Software , Tomografia Computadorizada de Emissão de Fóton Único/métodos
13.
Nucl Med Commun ; 22(2): 189-96, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11258406

RESUMO

BACKGROUND: 201Tl myocardial scintigraphy (201Tl SPECT) is of strong prognostic value in various populations with suspected or known coronary artery disease. However, its value in patients with coronary artery bypass grafting (CABG) is not fully assessed. METHODS: We examined 115 consecutive patients to determine the relation between clinical data/stress 201Tl SPECT performed 5+/-3 years after CABG, and subsequent cardiac events. RESULTS: Thirteen patients (11%) had stress-induced angina, 22 (19%) had electrical positivity, and 97 (84%) had abnormal scintigraphy, including 62 (54%) with reversible defects. During follow-up (35+/-22 months), there were nine cardiac deaths, seven myocardial infarctions, and 20 revascularization procedures. Multivariate Cox analysis identified the delay between CABG and scintigraphy (P<0.01, relative risk (RR) = 1.01), the extent of stress 201Tl defects (P = 0.04, RR = 1.18), and increased stress 201Tl lung uptake (P = 0.03, RR = 3.56) as significant predictors of cardiac deaths/infarctions. Delay between CABG and scintigraphy (P < 0.001, RR = 1.01), the extent of stress 201Tl defects (P = 0.03, RR = 1.15), and that of reversible defects (P = 0.05, RR = 1.13) were the only significant predictors of total events. CONCLUSIONS: Besides the delay between CABG and scintigraphy, the scintigraphic parameters were the only significant and additive predictors of cardiac events in 115 patients with CABG.


Assuntos
Ponte de Artéria Coronária , Coração/diagnóstico por imagem , Tálio , Adulto , Idoso , Intervalo Livre de Doença , Teste de Esforço , Feminino , Seguimentos , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único
14.
J Nucl Med ; 42(1): 21-6, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11197973

RESUMO

UNLABELLED: Somatostatin receptor scintigraphy (SRS) has been shown to reveal sarcoidosis sites. The aim of this study was to prospectively compare SRS and gallium scintigraphy in the evaluation of pulmonary and extrapulmonary involvement in patients with proven sarcoidosis. METHODS: Eighteen patients with biopsy-proven sarcoidosis were included. Nine were or recently had been receiving steroid therapy at the time of the examination. Planar gallium scintigraphy (head, chest, abdomen, and pelvis) and thoracic SPECT were performed at 48-72 h after injection of a mean dose of 138 +/- 21 MBq 67Ga. Planar SRS and thoracic SPECT were performed at 4 and 24 h after injection of a mean dose of 148 +/- 17 MBq 111n-pentetreotide. RESULTS: Gallium scintigraphy found abnormalities in 16 of 18 patients (89%) and detected 64 of 99 clinically involved sites (65%). SRS found abnormalities in 18 of 18 patients and detected 82 of 99 clinically involved sites (83%). Of the 9 treated patients, gallium scintigraphy found abnormalities in 7 (78%), detecting 23 of 39 clinically involved sites (59%), whereas SRS found abnormalities in 9, detecting 32 of 39 clinically involved sites (82%). CONCLUSION: This study suggests that, compared with gallium scintigraphy, SRS appears to be accurate and contributes to a better evaluation of organ involvement in sarcoidosis patients, especially those treated with corticosteroids.


Assuntos
Radioisótopos de Gálio , Radioisótopos de Índio , Receptores de Somatostatina/análise , Sarcoidose Pulmonar/diagnóstico por imagem , Sarcoidose/diagnóstico por imagem , Somatostatina/análogos & derivados , Tomografia Computadorizada de Emissão de Fóton Único , Corticosteroides/uso terapêutico , Adulto , Feminino , Humanos , Masculino , Estudos Prospectivos , Sarcoidose/tratamento farmacológico , Sarcoidose/metabolismo , Sarcoidose Pulmonar/tratamento farmacológico , Sarcoidose Pulmonar/metabolismo
15.
J Nucl Med ; 41(11): 1808-12, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11079487

RESUMO

UNLABELLED: Langerhans' cell histiocytosis is a granulomatous disease that may involve multiple organs and the prognosis of which is highly variable. Because the prognosis depends particularly on the number of tissues involved, the accurate identification of the organs involved by granulomatous lesions is of critical importance. We hypothesized that 111In-pentetreotide scintigraphy would be useful for evaluation of patients with Langerhans' cells histiocytosis. METHODS: Thirteen patients (38.3+/-10.4 y) with Langerhans' cell histiocytosis (8 patients with unifocal lung disease, 5 with multifocal disease) received intravenous 111In-pentetreotide (111-222 MBq), and planar images were obtained at 24 h after injection. Pulmonary uptake was quantified using a lung-to-background ratio (L/B) and compared with a population of 10 normal scintigrams. For the other sites, uptake of radioactivity in disease-related areas was visually assessed. RESULTS: Ten of 12 patients with lung involvement had increased lung uptake (UB, 2.23+/-0.49 versus 1.34+/-0.07; P < 0.001). In the patients with multifocal disease, increased 111In-pentetreotide uptake was found in disease-related areas such as the salivary glands, the skin, the soft tissues, and the bones. However, somatostatin receptor imaging was insensitive for detecting central nervous system and liver involvement and most skin lesions. CONCLUSION: 111In-pentetreotide imaging may be useful in Langerhans' cell histiocytosis. Further study will indicate whether 111In-pentetreotide is a relevant tracer in the management of histiocytosis.


Assuntos
Histiocitose de Células de Langerhans/diagnóstico por imagem , Radioisótopos de Índio , Somatostatina/análogos & derivados , Adulto , Osso e Ossos/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Fígado/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Cintilografia , Glândulas Salivares/diagnóstico por imagem , Pele/diagnóstico por imagem
16.
J Nucl Med ; 41(4): 567-74, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10768554

RESUMO

UNLABELLED: Exercise lung 201 TI uptake calculated with planar imaging has an important diagnostic and prognostic value in patients with coronary artery disease (CAD). However, its value with SPECT imaging raises methodological concerns and is controversial. We studied its value for the discrimination between extensive (E) and limited (L) angiographic CAD with exercise SPECT. METHODS: Four methods of lung-to-heart ratio quantification were calculated in patients with a low likelihood (< 5%) of CAD (n = 62). Their dependent variables were defined, and corresponding correction equations were derived. Receiver operating characteristic (ROC) analysis was performed in a pilot group (L-CAD, n = 49; E-CAD, n = 126) to define the optimal method of calculation of the lung-to-heart ratio. Its best threshold providing the best sensitivity for a specificity of 90% was defined. After correction for dependent variables, the 4 methods were also compared by ROC analysis and the optimal corrected method was compared with the optimal uncorrected method using ROC analysis and the best threshold. The consistency of these results in the validation group (L-CAD, n = 41; E-CAD, n = 122) and of the results of visual analysis of lung 201TI uptake were then verified. RESULTS: On ROC analysis in the pilot group, the optimal method of calculation of the lung-to-heart ratio was the mean activity in a region of interest drawn at the base of the lungs to the mean activity over the heart (Lb/H). For the best threshold, Lb/H presented a sensitivity of 34%. Corrected Lb/H still remained the best method of calculation on ROC analysis compared with the other corrected methods. On ROC analysis, there was no difference between corrected and uncorrected Lb/H. For the best threshold, corrected Lb/H presented a similar sensitivity of 37% compared with uncorrected Lb/H. When applied to the validation group (L-CAD, n = 41; E-CAD, n = 122), the best-defined threshold in the pilot group for corrected Lb/H presented a diagnostic value similar to that in the pilot group (sensitivity, 41%; specificity, 90%), but uncorrected Lb/H presented a higher sensitivity (47%; P < 0.04) and a slightly lower specificity (80%). Results of lung 201TI uptake visual analysis were inconsistent between pilot and validation groups (42% versus 58% sensitivity, P = 0.012; 86% versus 66% specificity, P = 0.023). CONCLUSIONS: For evaluation of E-CAD versus L-CAD, quantification of the exercise lung-to-heart 201TI uptake ratio with SPECT is feasible, reproducible, more discriminate than simple visual analysis, and best calculated as Lb/H. It presents an intrinsic diagnostic value even after correction for other clinically valuable dependent variables.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único , Estudos de Casos e Controles , Angiografia Coronária , Doença das Coronárias/epidemiologia , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
J Nucl Med ; 41(3): 393-9, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10716308

RESUMO

UNLABELLED: 201TI reverse redistribution is a common finding early after reperfusion therapy for myocardial infarction. Its mechanism and clinical implications remain unclear. The aim of this study was to clarify the relationships between reverse redistribution, microvascular perfusion, and myocardial viability. METHODS: Resting, 10-min-postinjection, and redistribution 201TI data obtained for 33 patients 8 and 42 d after the onset of acute myocardial infarction were compared with echocardiographic wall motion measured acutely and on day 42. Microvascular perfusion was assessed by myocardial contrast echocardiography performed 10 min after restoration of complete patency of the infarct artery. RESULTS: Marked significant reverse redistribution was found on day 8 (absolute change, 7.5%+/-7.9% of the 10-min-postinjection defect size; P<5x0.000001) and significantly decreased on day 42 (2.7%+/-6.8%; P = 0.004 between days 8 and 42). The 10-min-postinjection defect size best predicted the final infarct size on day 42 and was closely related to microvascular perfusion. Patients with adequate reperfusion had a smaller postinjection defect on day 8 (21.1%+/-14.6%) and a larger reverse redistribution (10.2%+/-6.1%) than did patients with no reflow (35.3%+/-13% and 3.2%+/-9.2%, respectively; P<0.04 for both). CONCLUSION: Reverse redistribution was marked early after myocardial infarction in patients with complete patency of the infarct artery and decreased in subsequent weeks. Reverse redistribution was associated with restoration of adequate microvascular reperfusion and with myocardial salvage and viability. The early postinjection scans on day 8 were the relevant images for assessing myocardial salvage and predicting wall motion recovery.


Assuntos
Infarto do Miocárdio/diagnóstico por imagem , Radioisótopos de Tálio , Circulação Coronária/fisiologia , Ecocardiografia , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Reperfusão Miocárdica , Compostos Radiofarmacêuticos , Fatores de Tempo , Tomografia Computadorizada de Emissão de Fóton Único
18.
J Nucl Med ; 40(10): 1602-8, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10520698

RESUMO

UNLABELLED: Scintigraphy with somatostatin analogs is a sensitive method for the staging and therapeutic management of patients with endocrine gastroenteropancreatic (GEP) tumors. The aim of this study was to compare prospectively somatostatin receptor scintigraphy (SRS) using 111n-pentetreotide with bone scintigraphy using 99mTc-hydroxymethylene diphosphonate for the detection of bone metastases. METHODS: One-hundred-forty-five patients with proven endocrine GEP tumors were investigated. Patients were classified according to the presence of bone metastases as indicated by CT, MRI or histologic data. Group I included 19 patients with confirmed bone metastases, and group II included 126 patients without bone metastases. RESULTS: In group I, SRS was positive in all 19 patients with bone metastases, and bone scintigraphy was positive in 17 patients. Bone metastases were found to occur predominantly in patients with liver metastases. In group 11, 5 patients had recent bone surgery for fracture or arthritis. SRS showed bone uptake in 4 of these patients, and bone scanning showed abnormal uptake in 5. In 7 of the remaining 121 group II patients, SRS was negative and bone scanning showed abnormal bone uptake suggesting bone metastases. The detection of bone metastases was of major prognostic value, because 42% of group 1 patients died during a 2-y follow-up. CONCLUSION: In patients with GEP tumors, the accuracy of SRS appears to be similar to that of bone scintigraphy for the detection of bone metastases.


Assuntos
Neoplasias Ósseas/secundário , Neoplasias do Sistema Digestório/diagnóstico por imagem , Ácido Pentético/análogos & derivados , Receptores de Somatostatina/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Ósseas/diagnóstico por imagem , Tumor Carcinoide/diagnóstico por imagem , Neoplasias do Sistema Digestório/metabolismo , Feminino , Humanos , Radioisótopos de Índio , Masculino , Pessoa de Meia-Idade , Octreotida/análogos & derivados , Estudos Prospectivos , Cintilografia , Compostos Radiofarmacêuticos , Somatostatina/análogos & derivados , Medronato de Tecnécio Tc 99m/análogos & derivados , Síndrome de Zollinger-Ellison/diagnóstico por imagem
19.
J Nucl Cardiol ; 6(4): 429-37, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10461610

RESUMO

BACKGROUND: Multiharmonic Fourier phase analysis of radionuclide angiography is a well-established method for the diagnosis of arrhythmogenic right ventricular cardiomyopathy. We sought to determine the optimal acquisition parameters: number of frames per cycle and number of counts per frame, with all other acquisition and processing parameters being fixed. METHODS AND RESULTS: Radionuclide angiography with list mode acquisition was performed in 10 normal subjects (pilot group) and 11 patients with arrhythmogenic right ventricular cardiomyopathy (validation group), allowing the reconstruction of electrocardiography-gated constant phase studies with different parameters: 16, 24, and 32 frames per cycle and 200, 400, 600, and 800 kcounts per frame. Three harmonics Fourier phase analysis was applied, and optimal acquisition parameters (defined as those providing best homogeneous phase distribution histogram in the pilot group) were defined as judged by the H3 right ventricular phase SD and delta 95%. These were 16 frames per cycle and 600 kcounts per frame. Then we verified in the validation group that these optimal acquisition parameters did not induce any significant relative loss of information compared with other acquisition parameters with more temporal resolution (24 and 32 frames per cycle) or more statistics (800 kcounts per frame). This result was realized by the calculation of normalized H3 right ventricular SD, right ventricular delta 95%, and (SD[left ventricle] - SD[right ventricle]). CONCLUSIONS: In practice, 16 frames per cycle and 600 kcounts per frame are optimal for multiharmonic Fourier phase analysis, with all other acquisition and processing variables being fixed as specified.


Assuntos
Displasia Arritmogênica Ventricular Direita/diagnóstico por imagem , Imagem do Acúmulo Cardíaco de Comporta , Adulto , Feminino , Análise de Fourier , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Projetos Piloto , Estudos Prospectivos , Processamento de Sinais Assistido por Computador
20.
J Nucl Med ; 40(5): 805-9, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-10319754

RESUMO

UNLABELLED: Left ventricular ejection fraction (LVEF) is a major prognostic factor in coronary artery disease and may be computed by 99mTc-methoxyisobutyl isonitrile (MIBI) gated SPECT. However, 201Tl remains widely used for assessing myocardial perfusion and viability. Therefore, we evaluated the feasibility and accuracy of both 99mTc-MIBI and 201Tl gated SPECT in assessing LVEF in patients with myocardial infarction, large perfusion defects and left ventricular (LV) dysfunction. METHODS: Fifty consecutive patients (43 men, 7 women; mean age 61 +/- 17 y) with a history of myocardial infarction (anterior, 26; inferior, 18; lateral, 6) were studied. All patients underwent equilibnum radionuclide angiography (ERNA) and rest myocardial gated SPECT, either 1 h after the injection of 1110 MBq 99mTc-MIBI (n = 19, group 1) or 4 h after the injection of 185-203 MBq 201Tl (n = 31, group 2) using a 90 degrees dual-head camera. After filtered backprojection (Butterworth filter: order 5, cutoff 0.25 99mTc or 0.20 201Tl), LVEF was calculated from reconstructed gated SPECT with a previously validated semiautomatic commercially available software quantitative gated SPECT (QGS). Perfusion defects were expressed as a percentage of the whole myocardium planimetered by bull's-eye polar map of composite nongated SPECT. RESULTS: Gated SPECT image quality was considered suitable for LVEF measurement in all patients. Mean perfusion defects were 36% +/- 18% (group 1), 33% +/- 17% (group 2), 34% +/- 17% (group 1 + group 2). LVEF was underestimated using gated SPECT compared with ERNA (34% +/- 12% and 39% +/- 12%, respectively; P = 0.0001). Correlations were high (group 1, r= 0.88; group 2, r = 0.76; group 1 + group 2, r = 0.82), and Bland-Altman plots showed a fair agreement between gated SPECT and ERNA. The difference between the two methods did not vary as LVEF, perfusion defect size or seventy increased or when the mitral valve plane was involved in the defect. CONCLUSION: LVEF measurement is feasible using myocardial gated SPECT with the QGS method in patients with large perfusion defects and LV dysfunction. However, both 201Tl and 99mTc-MIBI gated SPECT similarly and significantly underestimated LVEF in patients with LV dysfunction and large perfusion defects.


Assuntos
Imagem do Acúmulo Cardíaco de Comporta , Infarto do Miocárdio/diagnóstico por imagem , Tecnécio Tc 99m Sestamibi , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Eletrocardiografia , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Volume Sistólico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...